1.
J Environ Monit ; 7(12): 1162-8, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16307067

RESUMO

Vehicular traffic is one of the main sources of antimony in highly populated urban areas like Buenos Aires where an overall traffic density of 1 500 000 vehicles per day (corresponding to 7500 vehicles km(-2)) is estimated. In this context, a study was undertaken to ascertain the levels of Sb and other traffic-related elements (TRE) in the atmosphere of this city. To this end, sixty-seven samples of PM-10 particulate matter were collected during eight days in nine representative sampling sites located downtown Buenos Aires and spread over an area of about 30 km2. The collection of particulate matter was performed on ash-free glass-fibre filters using high volume samplers with PM-10 sampling heads. A combination of aqua regia and perchloric acid was used for leaching metals from filters. The resulting solutions were evaporated and then diluted with 0.1 mol l(-1) HCl. Antimony was determined by inductively coupled plasma-quadrupole mass spectrometry (ICP-QMS) at ng g(-1) levels. Concentrations of Sb varied from 12.9 +/- 0.9 to 375 +/- 23 microg g(-1)(equivalent to 0.87 +/- 0.06 to 15.3 +/- 0.8 ng m(-3)). Statistical analysis was performed on the data set including the measured PM-10 mass and Sb concentrations for the monitored period. Correlations of Sb with other TRE namely, Cu and Mo were also assessed. The highest concentrations of Sb were detected at two sites (Hospital Alemán and Casa Rapallini) located in streets with traffic consisting mostly of passenger cars and showing a "stop-and-go" pattern in peak hours. Antimony levels in the Buenos Aires PM-10 are by far below the level of 0.5 mg m(-3)(for an 8 hour workday, 40 hour work week) set by the US Occupational Safety and Health Administration (OSHA) for occupational exposure. However, monitoring of Sb and other TRE should be carried out in a systematic fashion to detect the possibility of increases in from the present levels.


Assuntos
Poluentes Atmosféricos/análise , Antimônio/análise , Poeira/análise , Argentina , Cidades , Monitoramento Ambiental , Veículos Automotores , Tamanho da Partícula , Emissões de Veículos
2.
J Environ Monit ; 7(1): 52-9, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15614402

RESUMO

A two step procedure that combines an air dispersion model with a receptor model was used to identify the key sources that contribute to air levels of suspended particulate matter. The contribution to PM(10) concentrations measured at four monitoring sites in San Nicolas, Argentina, of the following sources, a thermal power plant, an integrated steel mill, motor vehicle exhaust fumes, and finally dust from paved and unpaved roads, have been analysed. Moreover, an air dispersion model was used to estimate the contribution of the thermal power plant, emissions of which have been described in depth by means of hourly fuel consumption and specific emission factors. The ratio "apportionment coefficient" was introduced to relate the contribution of this source to the measured 24 h PM(10) concentrations by analysing the frequency of occurrence of connecting winds between the power plant and each monitoring site. In San Nicolas 70% of the PM(10) sampled at three of the four monitoring sites could be attributed to the power plant in those scenarios where winds connected the facility's tall point sources with the sampling locations. The contribution to the measured PM(10) levels of the rest of the sources that are present in the analysed area was confirmed by way of receptor models. For this purpose, the multielemental composition of 41 samples was determined by Wavelength Dispersive X-ray Fluorescence analysis. In order to ascertain the underlying correlations between PM(10) samples and potential sources, Principal Component Analysis was performed on the standard matrix of composition profiles, which comprises the measured PM(10) samples being enlarged with the composition profiles of the potential contributing sources. The diagonalization of the covariance matrix was used as a screening procedure to differentiate the most likely contributing sources from those that were not significant.


Assuntos
Poluição do Ar/análise , Monitoramento Ambiental , Emissões de Veículos/análise , Movimentos do Ar , Argentina , Análise de Componente Principal , Saúde da População Urbana
3.
J Environ Monit ; 6(4): 286-94, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15054536

RESUMO

A study was undertaken, within the framework of a 3 years national project, to assess the content of 13 elements in airborne particulate matter collected in representative zones of the metropolitan area of Buenos Aires. The sampling strategy followed consisted in collecting simultaneously 67 samples of PM10 particulate matter in 9 sampling sites covering an area of about 30 km2 during one week. The collection was performed on ash-free fibre-glass filters using high volume samplers. A combination of aqua regia and perchloric acid was used for leaching metals from filters. Key elements, namely Al, Ca, Cu, Fe, Mn, Mo, Ni, Pb, S, Sb, Sn, Zn and Zr, were determined by inductively coupled plasma-optical emission spectrometry (ICP-OES) and inductively coupled plasma-mass spectrometry (ICP-MS) at micro g g(-1) and ng g(-1) levels. Analyte concentration varied from 130 ng g(-1)(Mo) to over 30%(Ca). Multivariate statistical analysis was performed on the data set including the measured elemental compositions for the monitored period. The atmospheric concentration found for Pb confirms the decreasing levels of this element since the introduction of unleaded gasoline in 1995: 88 ng m(-3)(2001) < 220 ng m(-3)(1997) < 3900 ng m(-3)(1994). The average S concentration above 3 microg m(-3) is somehow unexpectedly high for Buenos Aires since the relatively low S content of liquid fuels and the massive usage of natural gas imply low emissions of this element from combustion activities. To the best of our knowledge, S concentrations are reported for the first time for this city.


Assuntos
Aerossóis/análise , Poluentes Atmosféricos/análise , Metais Pesados/análise , Oligoelementos/análise , Argentina , Cidades , Monitoramento Ambiental
4.
J Air Waste Manag Assoc ; 52(2): 140-6, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15143788

RESUMO

A statistical analysis of a series of ambient air concentrations of suspended particulate matter (SPM) and NO2 is presented. Measurements were taken at four sites that belong to an Argentinean steel mill and in another site located in its vicinity. The air pollutants were measured during a three-week exploratory sampling. The monitoring sites were selected on the basis of relevant characteristics of the emission sources and the corresponding climatological statistics of the last decade. Suspended particulate matter with aerodynamic diameter of less than 10 microm (PM10) and NO2 were continuously measured at only one site, while 1-hr samples of NO2 and 24-hr samples of total SPM and SO2 were collected at the other sites. The registered concentrations show that SPM was the pollutant of major concern. A first estimate about the nature of the contribution of the different sources of particles and NO2 present in the area was obtained through the statistical analysis of measured concentration data coupled with prevalent meteorological variables.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poluição do Ar/análise , Metalurgia , Aço , Poluição do Ar/estatística & dados numéricos , Argentina , Monitoramento Ambiental , Análise de Componente Principal
5.
In. AIDIS. Trabajos presentados. Rosario, AIDIS, 1998. , ilus. (64566).
Monografia em Espanhol | BINACIS | ID: bin-64566

RESUMO

A partir de 1994, mediante un acuerdo de cooperación entre la Secretaría de Energía, la Comisión Nacional de Energía Atómica y el Ente Nacional Regulador de la Electricidad, el Grupo Monitoreo Ambiental realiza mediciones de los principales contaminantes provenientes de la combustión fósil tanto en las chimeneas de centrales termoeléctricas como en el aire ambiente en la vecindad de las mismas. Aquí se presentan resultados de factores de emisión de óxidos de nitrógeno, diagnósticos del vínculo fuente-receptor a través de redes neuronales y una revisión del desarrollo de la Guía Metodológica para la Evaluación del Impacto Ambiental Atmosférico


Assuntos
Poluição do Ar , Centrais Elétricas , Congresso
SELEÇÃO DE REFERÊNCIAS