Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Adv Healthc Mater ; : e2401213, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38856313

RESUMO

The recent decade has witnessed a remarkable surge in the field of nanoparticles, from their synthesis, characterization, and functionalization to diverse applications. At the nanoscale, these particles exhibit distinct physicochemical properties compared to their bulk counterparts, enabling a multitude of applications spanning energy, catalysis, environmental remediation, biomedicine, and beyond. This review focuses on specific nanoparticle categories, including magnetic, gold, silver, and quantum dots (QDs), as well as hybrid variants, specifically tailored for biomedical applications. A comprehensive review and comparison of prevalent chemical, physical, and biological synthesis methods are presented. To enhance biocompatibility and colloidal stability, and facilitate surface modification and cargo/agent loading, nanoparticle surfaces are coated with different synthetic polymers and very recently, cell membrane coatings. The utilization of polymer- or cell membrane-coated nanoparticles opens a wide variety of biomedical applications such as magnetic resonance imaging (MRI), hyperthermia, photothermia, sample enrichment, bioassays, drug delivery, etc. With this review, the goal is to provide a comprehensive toolbox of insights into polymer or cell membrane-coated nanoparticles and their biomedical applications, while also addressing the challenges involved in translating such nanoparticles from laboratory benchtops to in vitro and in vivo applications. Furthermore, perspectives on future trends and developments in this rapidly evolving domain are provided.

2.
ACS Omega ; 9(23): 24181-24202, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38882113

RESUMO

Optical biosensors exhibit immense potential, offering extraordinary possibilities for biosensing due to their high sensitivity, reusability, and ultrafast sensing capabilities. This review provides a concise overview of optical biosensors, encompassing various platforms, operational mechanisms, and underlying physics, and it summarizes recent advancements in the field. Special attention is given to plasmonic biosensors and metasurface-based biosensors, emphasizing their significant performance in bioassays and, thus, their increasing attraction in biosensing research, positioning them as excellent candidates for lab-on-chip and point-of-care devices. For plasmonic biosensors, we emphasize surface plasmon resonance (SPR) and its subcategories, along with localized surface plasmon resonance (LSPR) devices and surface enhance Raman spectroscopy (SERS), highlighting their ability to perform diverse bioassays. Additionally, we discuss recently emerged metasurface-based biosensors. Toward the conclusion of this review, we address current challenges, opportunities, and prospects in optical biosensing. Considering the advancements and advantages presented by optical biosensors, it is foreseeable that they will become a robust and widespread platform for early disease diagnostics.

3.
Nanoscale ; 16(25): 11802-11824, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38809214

RESUMO

Recent advancements in medical imaging have brought forth various techniques such as magnetic resonance imaging (MRI), computed tomography (CT), positron emission tomography (PET), and ultrasound, each contributing to improved diagnostic capabilities. Most recently, magnetic particle imaging (MPI) has become a rapidly advancing imaging modality with profound implications for medical diagnostics and therapeutics. By directly detecting the magnetization response of magnetic tracers, MPI surpasses conventional imaging modalities in sensitivity and quantifiability, particularly in stem cell tracking applications. Herein, this comprehensive review explores the fundamental principles, instrumentation, magnetic nanoparticle tracer design, and applications of MPI, offering insights into recent advancements and future directions. Novel tracer designs, such as zinc-doped iron oxide nanoparticles (Zn-IONPs), exhibit enhanced performance, broadening MPI's utility. Spatial encoding strategies, scanning trajectories, and instrumentation innovations are elucidated, illuminating the technical underpinnings of MPI's evolution. Moreover, integrating machine learning and deep learning methods enhances MPI's image processing capabilities, paving the way for more efficient segmentation, quantification, and reconstruction. The potential of superferromagnetic iron oxide nanoparticle chains (SFMIOs) as new MPI tracers further advanced the imaging quality and expanded clinical applications, underscoring the promising future of this emerging imaging modality.


Assuntos
Nanopartículas de Magnetita , Humanos , Nanopartículas de Magnetita/química , Imageamento por Ressonância Magnética/métodos , Animais , Nanopartículas Magnéticas de Óxido de Ferro/química , Tomografia por Emissão de Pósitrons , Meios de Contraste/química
4.
Nanoscale ; 16(14): 7041-7057, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38444246

RESUMO

Magnetic nanoparticles (MNPs) have recently gained significant attention in various fields, including chemical and biomedical applications, due to their exceptional properties. However, separating MNPs from solution via magnetophoresis is challenging when MNPs are smaller than 50 nm as Brownian forces become on the order of the magnetic forces. In this study, we successfully separated small MNPs (5-30 nm) by utilizing high magnetic fields and gradients generated by economical permanent magnets. In situ small angle X-ray scattering (SAXS) was used to investigate the time-dependent concentration changes in the ferrofluid, and the results validated that only the 30 nm particles experienced particle aggregation or agglomeration, indicating that dipole-dipole interactions did not play a discernable role in the separation process for particles smaller than ∼15 nm. However, numerical simulations have provided further validation that in the absence of particle-particle interactions, even MNPs with diameters less than 15 nm exhibited magnetophoresis that effectively counteracted the effects of Brownian motion.

5.
Small ; 20(5): e2304848, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37732364

RESUMO

Nowadays, magnetic nanoparticles (MNPs) are applied in numerous fields, especially in biomedical applications. Since biofluidic samples and biological tissues are nonmagnetic, negligible background signals can interfere with the magnetic signals from MNPs in magnetic biosensing and imaging applications. In addition, the MNPs can be remotely controlled by magnetic fields, which make it possible for magnetic separation and targeted drug delivery. Furthermore, due to the unique dynamic magnetizations of MNPs when subjected to alternating magnetic fields, MNPs are also proposed as a key tool in cancer treatment, an example is magnetic hyperthermia therapy. Due to their distinct surface chemistry, good biocompatibility, and inducible magnetic moments, the material and morphological structure design of MNPs has attracted enormous interest from a variety of scientific domains. Herein, a thorough review of the chemical synthesis strategies of MNPs, the methodologies to modify the MNPs surface for better biocompatibility, the physicochemical characterization techniques for MNPs, as well as some representative applications of MNPs in disease diagnosis and treatment are provided. Further portions of the review go into the diagnostic and therapeutic uses of composite MNPs with core/shell structures as well as a deeper analysis of MNP properties to learn about potential biomedical applications.


Assuntos
Hipertermia Induzida , Nanopartículas de Magnetita , Nanopartículas de Magnetita/uso terapêutico , Nanopartículas de Magnetita/química , Sistemas de Liberação de Medicamentos/métodos , Magnetismo/métodos , Hipertermia Induzida/métodos , Campos Magnéticos
6.
Electrophoresis ; 2023 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-38041407

RESUMO

Precisely and accurately determining the magnetic force and its spatial distribution in microfluidic devices is challenging. Typically, magnetic microfluidic devices are designed in a way to both maximize the force within the separation region and to minimize the necessity for knowing such details-such as designing magnetic geometries that create regions of nearly constant magnetic force or that dictate the behavior of the magnetic force to be highly predictable in a specified region. In this work, we present a method to determine the spatial distribution of the magnetic force field in a magnetic microfluidic device by particle tracking magnetophoresis. Polystyrene microparticles were suspended in a paramagnetic fluid, gadolinium, and this suspension was exposed to various magnetic field geometries. Polystyrene particle motion was tracked using a microscope and images processed using Fiji (ImageJ). From a sample with a large spatial distribution of particle tracks, the magnetic force field distribution was calculated. The force field distribution was fitted to nonlinear spatial distribution models. These experimental models are compared to and supported by 3D simulations of the magnetic force field in COMSOL.

7.
Micromachines (Basel) ; 14(11)2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-38004965

RESUMO

Superparamagnetic iron oxide nanoparticles (SPIONs) have gathered tremendous scientific interest, especially in the biomedical field, for multiple applications, including bioseparation, drug delivery, etc. Nevertheless, their manipulation and separation with magnetic fields are challenging due to their small size. We recently reported the coupling of cooperative magnetophoresis and sedimentation using quadrupole magnets as a promising strategy to successfully promote SPION recovery from media. However, previous studies involved SPIONs dispersed in organic solvents (non-biocompatible) at high concentrations, which is detrimental to the process economy. In this work, we investigate, for the first time, the magnetic separation of 20 nm and 30 nm SPIONs dispersed in an aqueous medium at relatively low concentrations (as low as 0.5 g·L-1) using our custom, permanent magnet-based quadrupole magnetic sorter (QMS). By monitoring the SPION concentrations along the vessel within the QMS, we estimated the influence of several variables in the separation and analyzed the kinetics of the process. The results obtained can be used to shed light on the dynamics and interplay of variables that govern the fast separation of SPIONs using inexpensive permanent magnets.

9.
ACS Appl Bio Mater ; 6(10): 4042-4059, 2023 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-37725557

RESUMO

Early-stage screening of cancer is critical in preventing its development and therefore can improve the prognosis of the disease. One accurate and effective method of cancer screening is using high sensitivity biosensors to detect optically, chemically, or magnetically labeled cancer biomarkers. Among a wide range of biosensors, giant magnetoresistance (GMR) based devices offer high sensitivity, low background noise, robustness, and low cost. With state-of-the-art micro- and nanofabrication techniques, tens to hundreds of independently working GMR biosensors can be integrated into fingernail-sized chips for the simultaneous detection of multiple cancer biomarkers (i.e., multiplexed assay). Meanwhile, the miniaturization of GMR chips makes them able to be integrated into point-of-care (POC) devices. In this review, we first introduce three types of GMR biosensors in terms of their structures and physics, followed by a discussion on fabrication techniques for those sensors. In order to achieve target cancer biomarker detection, the GMR biosensor surface needs to be subjected to biological decoration. Thus, commonly used methods for surface functionalization are also reviewed. The robustness of GMR-based biosensors in cancer detection has been demonstrated by multiple research groups worldwide and we review some representative examples. At the end of this review, the challenges and future development prospects of GMR biosensor platforms are commented on. With all their benefits and opportunities, it can be foreseen that GMR biosensor platforms will transition from a promising candidate to a robust product for cancer screening in the near future.

10.
Sci Total Environ ; 878: 162953, 2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-36948304

RESUMO

On March 11, 2020, the World Health Organization declared the coronavirus disease 2019 (COVID-19), whose causative agent is the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), a pandemic. This virus is predominantly transmitted via respiratory droplets and shed via sputum, saliva, urine, and stool. Wastewater-based epidemiology (WBE) has been able to monitor the circulation of viral pathogens in the population. This tool demands both in-lab and computational work to be meaningful for, among other purposes, the prediction of outbreaks. In this context, we present a systematic review that organizes and discusses laboratory procedures for SARS-CoV-2 RNA quantification from a wastewater matrix, along with modeling techniques applied to the development of WBE for COVID-19 surveillance. The goal of this review is to present the current panorama of WBE operational aspects as well as to identify current challenges related to it. Our review was conducted in a reproducible manner by following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for systematic reviews. We identified a lack of standardization in wastewater analytical procedures. Regardless, the reverse transcription-quantitative polymerase chain reaction (RT-qPCR) approach was the most reported technique employed to detect and quantify viral RNA in wastewater samples. As a more convenient sample matrix, we suggest the solid portion of wastewater to be considered in future investigations due to its higher viral load compared to the liquid fraction. Regarding the epidemiological modeling, the data-driven approach was consistently used for the prediction of variables associated with outbreaks. Future efforts should also be directed toward the development of rapid, more economical, portable, and accurate detection devices.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , SARS-CoV-2 , Vigilância Epidemiológica Baseada em Águas Residuárias , Águas Residuárias , RNA Viral
11.
Biotechnol Bioeng ; 120(7): 1707-1724, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36999568

RESUMO

Iron in blood cells has several physiological functions like transporting oxygen to cells and maintaining iron homeostasis. Iron is primarily contained in red blood cells (RBCs), but monocytes also store iron as these cells are responsible for the recycling of senescent RBCs. Iron also serves an important role related to the function of different leukocytes. In inflammation, iron homeostasis is dependent on cytokines derived from T cells and macrophages. Fluctuations of iron content in the body lead to different diseases. Iron deficiency, which is also known as anemia, hampers different physiological processes in the human body. On the other hand, genetic or acquired hemochromatosis ultimately results in iron overload and leads to the failure of different vital organs. Different diagnoses and treatments are developed for these kinds of disorders, but the majority are costly and suffer from side effects. To address this issue, magnetophoresis could be an attractive technology for the diagnosis (and in some cases treatment) of these pathologies due to the paramagnetic character of the cells containing iron. In this review, we discuss the main functions of iron in blood cells and iron-related diseases in humans and highlight the potential of magnetophoresis for diagnosing and treating some of these disorders.


Assuntos
Sobrecarga de Ferro , Ferro , Humanos , Sobrecarga de Ferro/patologia , Sobrecarga de Ferro/terapia , Eritrócitos , Macrófagos/patologia , Fenômenos Magnéticos
12.
IEEE Trans Biomed Eng ; 69(12): 3582-3590, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35544484

RESUMO

Sickle cell disease (SCD) is an inherited blood disorder that affects millions of people worldwide, especially in low-resource regions of the world, where a rapid and affordable test to properly diagnose the disease would be highly valued. Magnetophoresis is a technique that could simultaneously analyze, quantify, and potentially separate the patient's sickle red blood cells (RBCs) from healthy RBCs, but the magnetic characteristics of sickle RBCs have yet to be reported. In this work, we present the single cell magnetic characterization of RBCs obtained from SCD patients. Sufficient single cells are analyzed from patient samples undergoing transfusion therapy and not yet having transfusion therapy (TP and NTP, respectively), such that means and distributions of these single RBC mobilities are created in the form of histograms which facilitated comparison to RBCs from healthy donors (HD). The magnetic characterization is obtained using a technique known as Cell Tracking Velocimetry (CTV) that quantitatively characterizes the RBC response to magnetic and gravitational fields. The magnetic properties of RBCs containing oxygenated, deoxygenated hemoglobin (Hb) and methemoglobin (oxyHb-RBCs, deoxyHb-RBCs, and metHb-RBCs) are further determined. The NTP samples reported the highest magnetic character, especially when compared to oxyHb-RBCs from HD, which implies impaired oxygen binding capabilities. Also, the oxygen-Hb equilibrium curves are obtained to estimate the magnetic character of the cells under intermediate oxygen levels. Our results confirm higher magnetic moment of SCD blood (NTP) under intermediate oxygen levels. These data demonstrate the potential feasibility of magnetophoresis to identify, quantify and separate sickle RBCs from healthy RBCs.


Assuntos
Anemia Falciforme , Eritrócitos , Humanos , Anemia Falciforme/terapia , Anemia Falciforme/metabolismo , Oxigênio/metabolismo , Fenômenos Magnéticos
13.
Sci Rep ; 12(1): 1692, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35105914

RESUMO

Anemia and iron deficiency continue to be the most prevalent nutritional disorders in the world, affecting billions of people in both developed and developing countries. The initial diagnosis of anemia is typically based on several markers, including red blood cell (RBC) count, hematocrit and total hemoglobin. Using modern hematology analyzers, erythrocyte parameters such as mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), etc. are also being used. However, most of these commercially available analyzers pose several disadvantages: they are expensive instruments that require significant bench space and are heavy enough to limit their use to a specific lab and lead to a delay in results, making them less practical as a point-of-care instrument that can be used for swift clinical evaluation. Thus, there is a need for a portable and economical hematology analyzer that can be used at the point of need. In this work, we evaluated the performance of a system referred to as the cell tracking velocimetry (CTV) to measure several hematological parameters from fresh human blood obtained from healthy donors and from sickle cell disease subjects. Our system, based on the paramagnetic behavior that deoxyhemoglobin or methemoglobin containing RBCs experience when suspended in water after applying a magnetic field, uses a combination of magnets and microfluidics and has the ability to track the movement of thousands of red cells in a short period of time. This allows us to measure not only traditional RBC indices but also novel parameters that are only available for analyzers that assess erythrocytes on a cell by cell basis. As such, we report, for the first time, the use of our CTV as a hematology analyzer that is able to measure MCV, MCH, mean corpuscular hemoglobin concentration (MCHC), red cell distribution width (RDW), the percentage of hypochromic cells (which is an indicator of insufficient marrow iron supply that reflects recent iron reduction), and the correlation coefficients between these metrics. Our initial results indicate that most of the parameters measured with CTV are within the normal range for healthy adults. Only the parameters related to the red cell volume (primarily MCV and RDW) were outside the normal range. We observed significant discrepancies between the MCV measured by our technology (and also by an automated cell counter) and the manual method that calculates MCV through the hematocrit obtained by packed cell volume, which are attributed to the artifacts of plasma trapping and cell shrinkage. While there may be limitations for measuring MCV, this device offers a novel point of care instrument to provide rapid RBC parameters such as iron stores that are otherwise not rapidly available to the clinician. Thus, our CTV is a promising technology with the potential to be employed as an accurate, economical, portable and fast hematology analyzer after applying instrument-specific reference ranges or correction factors.


Assuntos
Anemia Falciforme/sangue , Rastreamento de Células/instrumentação , Índices de Eritrócitos , Citometria de Fluxo/instrumentação , Microfluídica/instrumentação , Adulto , Estudos de Casos e Controles , Confiabilidade dos Dados , Contagem de Eritrócitos , Eritrócitos , Feminino , Hematócrito , Hemoglobinas/análise , Humanos , Campos Magnéticos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
14.
Sep Purif Technol ; 2802022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35035269

RESUMO

Superparamagnetic iron oxide nanoparticles (SPIONs) are currently popular materials experiencing rapid development with potential application value, especially in biomedical and chemical engineering fields. Examples include wastewater management, bio-detection, biological imaging, targeted drug delivery and biosensing. While not exclusive, magnetically driven isolation methods are typically required to separate the desired entity from the media in specific applications and in their manufacture and/or quality control. However, due to the nano-size of SPIONs, their magnetic manipulation is affected by Brownian motion, adding considerable complexities. The two most common methods for SPION magnetic separation are high and low gradient magnetic separation (HGMS and LGMS, respectively). Nevertheless, the effect of specific magnetic energy fields on SPIONs, such as horizontal (perpendicular to gravity), high fields and gradients (higher than LGMS) on the horizontal magnetophoresis and vertical sedimentation of SPIONs has only recently been suggested as a way to separate very small particles (5 nm). In this work, we continue those studies on the magnetic separation of 5-30 nm SPIONs by applying fields and gradients perpendicular to gravity. The magnetic field was generated by permanent magnets arranged in quadrupolar configurations (QMS). Different conditions were studied, and multiple variables were evaluated, including the particle size, the initial SPIONs concentration, the temperature, the magnetic field gradient and the magnetic exposure time. Our experimental data show that particles are subjected to horizontal magnetic forces, to particle agglomeration due to dipole-dipole interactions, and to vertical sedimentation due to gravity. The particle size and the type of separator employed (i.e. different gradient and field distribution acting on the particle suspension) have significant effects on the phenomena involved in the separation, whereas the temperature and particle concentration affect the separation to a lesser extent. Finally, the separation process was observed to occur in less than 3 mins for our experimental conditions, which is encouraging considering the long operation time (up to days) necessary to separate particles of similar sizes in LGMS columns that also employ permanent magnets.

15.
Ind Eng Chem Res ; 60(46): 16780-16790, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34866775

RESUMO

The design of microdevices in which components with magnetic character must be separated and recovered from reactive media benefits from the advantages of microfluidics and meets the criteria for process intensification; however, there are open questions, such as the design of the most appropriate magnet arrangement, that need further research in order to increase the magnetic gradient exerted on the particles. Herein, we focus on the continuous recovery of magnetic microparticles, that can be used as support to facilitate the recovery of biocatalysts (magnetic microcatalysts, MMCs) from biological fluids. We analyze and compare the performance of two typical magnetophoretic microdevices for addressing bead recovery: (i) annular channels with a quadrupole orientation of the permanent magnets (quadrupole magnetic sorter, QMS) and (ii) the standard design, which consists of rectangular channels with a single permanent magnet to generate the magnetic field. To this end, an experimentally validated computational fluid dynamics (CFD) numerical model has been employed. Our results reveal that for devices with the same width and length, the micro-QMS, in comparison to a rectangular channel, could accomplish the complete particle retrieval while (i) processing more than 4 times higher fluid velocities, treating more than 360 times higher flow rates or (ii) working with smaller particles, thus reducing by 55% the particle mass. Additionally, the parallel performance of ≈300 micro-QMSs fulfills the processing of flow rates as high as 200 L·h-1 while entirely capturing the magnetic beads. Thereby, this work shows the potential of the QMS advanced design in the intensification of the recovery of catalysts supports of magnetic character.

16.
PLoS One ; 16(9): e0257061, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34478473

RESUMO

A new method for hemoglobin (Hb) deoxygenation, in suspension or within red blood cells (RBCs) is described using the commercial enzyme product, EC-Oxyrase®. The enzymatic deoxygenation method has several advantages over established deoxygenation methodologies, such as avoiding side reactions that produce methemoglobin (metHb), thus eliminating the need for an inert deoxygenation gas and airtight vessel, and facilitates easy re-oxygenation of Hb/RBCs by washing with a buffer that contains dissolved oxygen (DO). The UV-visible spectra of deoxyHb and metHb purified from human RBCs using three different preparation methods (sodium dithionite [to produce deoxyHb], sodium nitrite [to produce metHb], and EC-Oxyrase® [to produce deoxyHb]) show the high purity of deoxyHb prepared using EC-Oxyrase® (with little to no metHb or hemichrome production from side reactions). The oxyHb deoxygenation time course of EC-Oxyrase® follows first order reaction kinetics. The paramagnetic characteristics of intracellular Hb in RBCs were compared using Cell Tracking Velocimetry (CTV) for healthy and sickle cell disease (SCD) donors and oxygen equilibrium curves show that the function of healthy RBCs is unchanged after EC-Oxyrase® treatment. The results confirm that this enzymatic approach to deoxygenation produces pure deoxyHb, can be re-oxygenated easily, prepared aerobically and has similar paramagnetic mobility to existing methods of producing deoxyHb and metHb.


Assuntos
Hemoglobinas/análise , Magnetismo , Oxiemoglobinas/análise , Anemia Falciforme , Feminino , Humanos , Masculino , Metemoglobina/análise , Oxigênio/análise , Doadores de Tecidos
17.
Exp Hematol ; 99: 21-31.e5, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34015390

RESUMO

The presence of iron in circulating monocytes is well known as they play an essential role in iron recycling. It has been demonstrated that the iron content of blood cells can be measured through their magnetic behavior; however, the magnetic properties of different monocyte subtypes remain unknown. In this study we report, for the first time, the magnetic behavior of classical, intermediate and non-classical monocytes, which may be related to their iron storage capacity. The magnetic properties of monocytes were compared with those of other blood cells, such as lymphocytes and red blood cells in the oxyhemoglobin and methemoglobin states, and a cancer cell type. For this analysis, we used an instrument referred to as a Cell Tracking Velocimetry (CTV), which quantitatively characterizes the magnetic behavior of biological entities. Our results revealed that significant fractions of the intermediate and non-classical monocytes (up to 59% and 65% depending on the sample, respectively) have paramagnetic properties, suggesting their higher iron storage capacities. Moreover, our findings have implications for the immunomagnetic separation industry; we propose that negative magnetic isolation techniques for recovering monocytes from blood should be used with caution, as it is possible to lose magnetic monocytes when using this technique.


Assuntos
Eritrócitos/citologia , Citometria de Fluxo , Campos Magnéticos , Monócitos/citologia , Eritrócitos/metabolismo , Humanos , Monócitos/metabolismo
18.
Soft Matter ; 16(41): 9506-9518, 2020 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-32966533

RESUMO

We present a numerical model that describes the microfluidic generation and manipulation of ferrofluid droplets under an external magnetic field. We developed a numerical Computational Fluid Dynamics (CFD) analysis for predicting and optimizing continuous flow generation and processing of ferrofluid droplets with and without the presence of a permanent magnet. More specifically, we explore the dynamics of oil-based ferrofluid droplets within an aqueous continuous phase under an external inhomogeneous magnetic field. The developed model determines the effect of the magnetic field on the droplet generation, which is carried out in a flow-focusing geometry, and its sorting in T-junction channels. Three-channel depths (25 µm, 30 µm, and 40 µm) were investigated to study droplet deformation under magnetic forces. Among the three, the 30 µm channel depth showed the most consistent droplet production for the studied range of flow rates. Ferrofluids with different loadings of magnetic nanoparticles were used to observe the behavior for different ratios of magnetic and hydrodynamic forces. Our results show that the effect of these factors on droplet size and generation rate can be tuned and optimized to produce consistent droplet generation and sorting. This approach involves fully coupled magnetic-fluid mechanics models and can predict critical details of the process including droplet size, shape, trajectory, dispensing rate, and the perturbation of the fluid co-flow for different flow rates. The model enables better understanding of the physical phenomena involved in continuous droplet processing and allows efficient parametric analysis and optimization.

19.
Sep Purif Technol ; 2482020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32655283

RESUMO

Superparamagnetic iron oxide nanoparticles (SPIONs) are employed in multiple applications, especially within medical and chemical engineering fields. However, their magnetic separation is very challenging as the magnetophoretic motion is hindered by thermal energy and viscous drag. Recent studies have addressed the recovery of SPIONs by a combination of cooperative magnetophoresis and sedimentation. Nevertheless, the effect of horizontal, high fields and gradients on the vertical sedimentation of SPIONs has not been described. In this work, we report, for the first time, the magnetically facilitated sedimentation of 5 nm particles by applying fields and gradients perpendicular to gravity. The magnetic field was generated by quadrupole magnetic sorters and the process was measured with time by tracking the concentration along the length of a channel contacting the 5 nm SPIONs within the quadrupole field. Our experimental data suggest that aggregates of 60-90 particles are formed in the system; thus, particle agglomeration by dipole-dipole interactions was promoted, and these clusters settled down as a result of gravitational forces. Multiple variables and parameters were evaluated, including the initial SPION concentration, the temperature, the magnetic field and gradient and operation time. It was found that the process was improved by decreasing the initial concentration and the temperature, but the magnitude of the magnetic field and gradient did not significantly affect the sedimentation. Finally, the separation process was rapid, with the systems reaching the equilibrium in approximately 20 minutes, which is a significant advantage in comparison to other systems that require longer times and larger particle sizes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...