Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Dent ; 149: 105273, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39084548

RESUMO

OBJECTIVES: The present study aimed to synthesize toothpastes containing Beta- TriCalcium Phosphate (ß-TCP) nanoparticles, functionalized with fluoride and tin, and test their ability to reduce erosive tooth wear (ETW). METHODS: Toothpastes were synthesized with the following active ingredients: 1100 ppm of fluoride (as sodium fluoride, F-), 3500 ppm of tin (as stannous chloride, Sn2+), and 800 ppm of ß-TCP (Sizes a - 20 nm; and b - 100 nm). Enamel specimens were randomly assigned into the following groups (n = 10): 1. Commercial toothpaste; 2. Placebo; 3 F-; 4. F- + ß-TCPa; 5. F- + ß-TCPb; 6. F- + Sn2+; 7. F- + Sn2+ + ß-TCPa and 8. F- + Sn2+ + ß-TCPb. Specimens were subjected to erosion-abrasion cycling. Surface loss (in µm) was measured by optical profilometry. Toothpastes pH and available F- were also assessed. RESULTS: Brushing with placebo toothpaste resulted in higher surface loss than brushing with F- (p = 0.005) and F- + ß-TCPb (p = 0.007); however, there was no difference between F- and F- + ß-TCPb (p = 1.00). Commercial toothpaste showed no difference from Placebo (p = 0.279). The groups F-, F- + ß-TCPa, F- + ß-TCPb, F- + Sn2+, F- + Sn2+ + ß-TCPa and F- + Sn2+ + ß-TCPb were not different from the commercial toothpaste (p > 0.05). Overall, the addition of ß-TCP reduced the amount of available fluoride in the experimental toothpastes. The pH of toothpastes ranged from 4.97 to 6.49. CONCLUSIONS: Although toothpaste containing ß-TCP nanoparticles protected enamel against dental erosion-abrasion, this effect was not superior to the standard fluoride toothpaste (commercial). In addition, the functionalization of ß-TCP nanoparticles with fluoride and tin did not enhance their protective effect. CLINICAL SIGNIFICANCE: Although ß-TCP nanoparticles have some potential to control Erosive Tooth Wear, their incorporation into an experimental toothpaste appears to have a protective effect that is similar to a commercial fluoride toothpaste.


Assuntos
Fosfatos de Cálcio , Esmalte Dentário , Nanopartículas , Erosão Dentária , Cremes Dentais , Fosfatos de Cálcio/química , Fosfatos de Cálcio/uso terapêutico , Cremes Dentais/química , Cremes Dentais/uso terapêutico , Erosão Dentária/prevenção & controle , Nanopartículas/química , Esmalte Dentário/efeitos dos fármacos , Concentração de Íons de Hidrogênio , Compostos de Estanho/uso terapêutico , Compostos de Estanho/química , Fluoreto de Sódio/uso terapêutico , Fluoreto de Sódio/química , Animais , Fluoretos/uso terapêutico , Estanho/química , Abrasão Dentária/prevenção & controle , Bovinos , Teste de Materiais , Propriedades de Superfície , Distribuição Aleatória , Escovação Dentária , Humanos
2.
J Appl Oral Sci ; 31: e20220428, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37194790

RESUMO

To characterize activated charcoal and 2% hydrogen peroxide-based toothpastes and investigate their effects on roughness, color change, and gloss of bulk-fill composite resin. Composite resin specimens (Aura Bulk Fill, SDI) were subjected to 5,000 brushing cycles with regular toothpaste (Colgate Total 12, [RT]), activated charcoal toothpaste (Bianco Dental Carbon, [AC]), or hydrogen peroxide-containing toothpaste (Colgate Luminous White Advanced, [HP]), with or without coffee exposure. The pH, particle characterization by scanning electron microscopy (SEM), and weight% of solid particles in the toothpaste were assessed. Roughness (Ra) was evaluated using a surface profile-measuring device, color change (∆Eab/∆E00) by reflectance spectrophotometer, and gloss unit (GU) by glossmeter. Kruskal-Wallis, Dunn, Friedman, and Nemenyi tests were used, and the correlation coefficient test was performed between Ra and GU (α=0.05). RT presented a higher Ra after brushing and did not change after staining with coffee; moreover, the ∆Eab/∆E00 values were higher for RT than HP. Regarding gloss, AC and HP obtained higher values compared to RT. A significant negative correlation between gloss and Ra was found for RT exposed to coffee. All toothpastes had a neutral pH; however, RT had the largest percentage of solids by weight. SEM images showed particles of many sizes: irregular shape (RT), more regular particles (AC), and spherical clusters (HP). Although surface roughness, color change, and gloss may compromise the longevity of restorations, the whitening toothpastes tested did not promote more morphology changes than regular toothpastes.


Assuntos
Peróxido de Hidrogênio , Cremes Dentais , Cremes Dentais/química , Carvão Vegetal , Café , Propriedades de Superfície , Escovação Dentária/métodos , Resinas Compostas , Cor
3.
J Dent ; 132: 104498, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36963626

RESUMO

OBJECTIVES: To compare the effect of whitening toothpastes with different mechanisms of action on discolored teeth subjected to additional staining/or not. METHODS: One hundred twenty tooth specimens were stained for 14 days (staining broth under constant agitation and pH=7) and then allocated into the groups of toothpastes with different whitening ingredients (n=10): 1. Regular - Colgate Total 12 Clean Mint; 2. CLWI - Colgate Luminous White Instant (blue pigment); 3. CLWA - Colgate Luminous White Advanced Expert (hydrogen peroxide); 4. CLWAC - Colgate Luminous White Activated Charcoal (activated charcoal); 5. OB3D - Oral-B 3D WHITE Brilliant Fresh (abrasive); 6. TW - Teeth Whitening (charcoal powder). Specimens were submitted to two experimental models: A. Daily staining-toothbrush cycling: staining solution (5min), toothbrushing (45 strokes) and artificial saliva (3h), 2x/day, for 5 days; B. Only toothbrushing (30.000 brushing strokes). Color change was determined with a spectrophotometer (CIEDE2000 and Whiteness Index for Dentistry - WID) and statistically analyzed (α=0.05). RESULTS: For both models, ΔE00 and Δa did not differ significantly between the whitening toothpastes and the regular. All groups showed a decrease in tooth yellowness (-Δb) and an increase in WID. Group Teeth Whitening exhibited a decrease in luminosity (-ΔL). In model A, Groups did not differ significantly from the Regular in terms of ΔL (p=0.35) and Δb (p=0.74). Groups CLWI and OB3D exhibited a decrease in luminosity. Reduced redness (-Δa) occurred only in Group CLWI. In Model B, Groups OB3D (p=0.021) and CLWA (p=0.001) exhibited higher change in luminosity than in Group Teeth Whitening. All exhibited increased redness (+Δa) and lightness (+ΔL), except the Regular, CLWAC, and Teeth Whitening. Group OB3D had a significantly higher change in Δb than the Regular (p=0.021). CONCLUSIONS: Irrespective of the mechanism of action, all toothpastes reduced tooth yellowness and promoted similar overall color change. Exposure of the teeth to additional staining during the toothbrushing cycles did not influence the effect of the whitening toothpastes. CLINICAL SIGNIFICANCE: Whitening toothpastes should be tested in conditions that more closely simulate their use in a clinical scenario, in which alternate cycles of staining and brushing occur on a daily basis. However, even in such conditions, they were unable to promote a color change that differed from that of a regular toothpaste.


Assuntos
Clareamento Dental , Descoloração de Dente , Dente , Humanos , Cremes Dentais/farmacologia , Escovação Dentária , Carvão Vegetal/farmacologia , Coloração e Rotulagem , Fluoreto de Sódio/farmacologia , Cor
4.
J. appl. oral sci ; J. appl. oral sci;31: e20220428, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1440412

RESUMO

Abstract Objective To characterize activated charcoal and 2% hydrogen peroxide-based toothpastes and investigate their effects on roughness, color change, and gloss of bulk-fill composite resin. Methodology Composite resin specimens (Aura Bulk Fill, SDI) were subjected to 5,000 brushing cycles with regular toothpaste (Colgate Total 12, [RT]), activated charcoal toothpaste (Bianco Dental Carbon, [AC]), or hydrogen peroxide-containing toothpaste (Colgate Luminous White Advanced, [HP]), with or without coffee exposure. The pH, particle characterization by scanning electron microscopy (SEM), and weight% of solid particles in the toothpaste were assessed. Roughness (Ra) was evaluated using a surface profile-measuring device, color change (∆Eab/∆E00) by reflectance spectrophotometer, and gloss unit (GU) by glossmeter. Kruskal-Wallis, Dunn, Friedman, and Nemenyi tests were used, and the correlation coefficient test was performed between Ra and GU (α=0.05). Results RT presented a higher Ra after brushing and did not change after staining with coffee; moreover, the ∆Eab/∆E00 values were higher for RT than HP. Regarding gloss, AC and HP obtained higher values compared to RT. A significant negative correlation between gloss and Ra was found for RT exposed to coffee. All toothpastes had a neutral pH; however, RT had the largest percentage of solids by weight. SEM images showed particles of many sizes: irregular shape (RT), more regular particles (AC), and spherical clusters (HP). Although surface roughness, color change, and gloss may compromise the longevity of restorations, the whitening toothpastes tested did not promote more morphology changes than regular toothpastes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA