Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 85(11): 11E827, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430392

RESUMO

Four-array system of soft X-ray diagnostics was installed on KSTAR tokamak. Each array has 32 viewing chords of two photo-diode array detectors with spatial resolution of 2 cm. To estimate signals from the soft X-ray radiation power, typical ne, Te, and argon impurity line radiation profiles in KSTAR are chosen. The photo-diodes were absolutely calibrated as a function of the incident photon energy in 2-40 keV range with a portable X-ray tube. Two-dimensional Te image properties by multi-energy method were simulated and visualized with six combinations of beryllium filter sets within the dynamic range of signal ratio.

2.
Rev Sci Instrum ; 81(10): 10E523, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034051

RESUMO

A gas detector with a 2D pixel readout is proposed for a future soft x-ray (SXR) tomography with discrimination in energy bands separately per pixel. The detector has three gas electron multiplier foils for the electron amplification and it offers the advantage, compared with the single stage, to be less sensitive to neutrons and gammas. The energy resolution and the detection efficiency of the detector have been accurately studied in the laboratory with continuous SXR spectra produced by an electronic tube and line emissions produced by fluorescence (K, Fe, and Mo) in the range of 3-17 keV. The front-end electronics, working in photon counting mode with a selectable threshold for pulse discrimination, is optimized for high rates. The distribution of the pulse amplitude has been indirectly derived by means of scans of the threshold. Scans in detector gain have also been performed to assess the capability of selecting different energy ranges.

3.
Phys Rev Lett ; 100(4): 045006, 2008 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-18352292

RESUMO

Disruption avoidance by stabilization of MHD modes through injection of ECRH at different radial locations is reported. Disruptions have been induced in the FTU (Frascati Tokamak Upgrade) deuterium plasmas by Mo injection or by exceeding the density limit (D gas puffing). ECRH is triggered when the V(loop) exceeds a preset threshold value. Coupling between MHD modes (m/n=3/2, 2/1, 3/1) occurs before disruption. Direct heating of one coupled mode is sufficient to avoid disruptions, while heating close to the mode leads to disruption delay. These results could be relevant for the International Thermonuclear Experimental Reactor tokamak operation.

4.
Phys Rev E Stat Nonlin Soft Matter Phys ; 64(3 Pt 2): 036406, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11580453

RESUMO

The spatial brightness profiles of emission lines for the K-like through He-like ionization states of Fe, Ge, and Ni have been measured during a set of experiments in which Fe and Ge were introduced into FTU tokamak plasmas by using the laser blowoff technique. Nickel was an intrinsic impurity observed during these experiments that was sputtered from the inconel limiter. The brightness profiles were measured by spatially scanable, photometrically calibrated vaccum ultraviolet and x-ray spectrometers that covered the 1 to 1700 A region. Simulations of these profiles and the time evolution of the laser blowoffs were performed with the MIST transport code using several sets of atomic physics compilations [ADPAK (originally in MIST), Arnaud and Raymond (AR92), Arnaud and Rothenflug (AR85), Mazzotta et al., and Mattioli (an extension to Mazzotta)]. The goal was to determine which set of available rates could best simulate the measured spatial brightness profiles and the charge state balance in the plasma. The Mazzotta et al. (for Fe and Ni), the Mattioli (for Ge), and the AR92 (for Fe only) rates adequately simulated the He-, Li-, Be-, Na-, Mg-like ionization states. The F- to B-like charge states could not be simulated by these compilations unless the relevant dielectronic rates were multiplied by a factor of 2. The ADPAK rates could not adequately predict any of the charge states of Fe, Ge, or Ni.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...