Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Farmaco ; 54(10): 700-4, 1999 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-10575740

RESUMO

A highly sensitive and simple voltammetric method is proposed for the determination of N-nitrosoatenolol (NA) and N-nitrosopropranolol (NP) in simulated gastric juice. The method is based on measuring the differential-pulse polarographic peak produced by NA and NP in Britton-Robinson buffers of pH 3 and 4 for NA and NP, respectively. Both compounds yielded diffusion-controlled current with diffusion-current constants of 7.23 +/- 0.03 and 9.46 +/- 0.06 for NA and NP, respectively. The current-concentration plots were rectilinear over the range 0.16-9.6 micrograms ml-1 with minimum detectability (S/N = 2) of 0.015 microgram ml-1 (5 x 10(-8) M) for NA; for NP the range was 0.08-8.0 micrograms ml-1 with minimum detectability (S/N = 2) of 0.009 microgram ml-1 (3 x 10(-8) M). The proposed method was successfully applied to study the possible in vivo production of the nitroso-derivatives under the standard nitrosation reaction conditions recommended by WHO. The method is characterized by simplicity and higher sensitivity as compared with the reported HPLC method.


Assuntos
Atenolol/metabolismo , Nitrosaminas/análise , Propranolol/análogos & derivados , Cromatografia Líquida de Alta Pressão , Concentração de Íons de Hidrogênio , Nitrosaminas/metabolismo , Polarografia , Propranolol/análise
2.
Farmaco ; 45(4): 465-72, 1990 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-2400519

RESUMO

High performance liquid chromatographic methods for the individual determination of khellin, phenobarbitone and dipyrone in tablets are presented. The methods specify a reverse phase column: methanol + water (68 + 32) as mobile phase at a flow rate of 0.7 ml/min with detection at 254 nm for khellin, visgnagin and dipyrone; water + ammonia + methanol (94.5 + 0.5 + 5) as a mobile phase at a flow rate of 0.7 ml/min with detection at 240 nm for phenobarbitone. At sensitivity of 0.01 AUFS, linearity ranges were found to be 0.5-4 micrograms/ml for khellin, 2.5-12.5 micrograms/ml for dipyrone and 1-7 micrograms/ml for phenobarbitone and with relative standard deviations less than 2%. The mean percentage recoveries +/- SD of khellin, dipyrone and phenobarbitone added to tablets were found to be 101.0 +/- 0.65, 100.0 +/- 0.74 and 99.9 +/- 0.74, respectively. The system can detect 2% w/w visnagin in khellin.


Assuntos
Aminopirina/análogos & derivados , Dipirona/análise , Quelina/análise , Fenobarbital/análise , Cromatografia Líquida de Alta Pressão , Combinação de Medicamentos , Indicadores e Reagentes , Espectrofotometria Ultravioleta , Comprimidos
4.
Talanta ; 33(2): 179-81, 1986 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18964059

RESUMO

Piperazine and its salts are reacted with aqueous alcoholic p-benzoquinone, buffered at pH 5.4, to give a coloured product with maximum absorption at 516nm. The piperazine base has a molar absorptivity of 0.96 x 10(4)l.mole(-1).cm(-1) and Beer's law is obeyed over the range 2-10 mug ml . When applied to three commercial preparations, the proposed method gave mean recoveries within 1% of those obtained by the official gravimetric method. The relative standard deviation was less than 1%.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...