Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 85(12): 123503, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25554289

RESUMO

The operation of next-generation fusion reactors will be significantly affected by impurity transport in the scrape-off layer (SOL). Current modelling efforts are restricted by a lack of detailed data on impurity transport in the SOL. In order to address this, a carbon injector has been designed and installed on the Mega Amp Spherical Tokamak (MAST). The injector creates short lived carbon plumes originating at the MAST divertor lasting less than 50 µs. High voltage capacitor banks are used to create a discharge across concentric carbon electrodes located in a probe mounted on the Divertor Science Facility in the MAST lower divertor. This results in a very short plume duration allowing observation of the evolution of the plume and precise localisation of the plume relative to the X-point on MAST. The emission from the carbon plume was imaged using fast visible cameras filtered in order to isolate the carbon II and carbon III emission lines centered around 514 nm and 465 nm.

2.
Rev Sci Instrum ; 83(1): 013508, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22299952

RESUMO

A new beam emission spectroscopy turbulence imaging system has recently been installed onto the MAST spherical tokamak. The system utilises a high-throughput, direct coupled imaging optics, and a single large interference filter for collection of the Doppler shifted D(α) emission from the ~2 MW heating beam of ~70 keV injection energy. The collected light is imaged onto a 2D array detector with 8 × 4 avalanche photodiode sensors which is incorporated into a custom camera unit to perform simultaneous 14-bit digitization at 2 MHz of all 32 channels. The array is imaged at the beam to achieve a spatial resolution of ~2 cm in the radial (horizontal) and poloidal (vertical) directions, which is sufficient for detection of the ion-scale plasma turbulence. At the typical photon fluxes of ~10(11) s(-1) the achieved signal-to-noise ratio of ~300 at the 0.5 MHz analogue bandwidth is sufficient for detection of relative density fluctuations at the level of a few 0.1%. The system is to be utilised for the study of the characteristics of the broadband, ion-scale turbulence, in particular its interaction with flow shear, as well as coherent fluctuations due to various types of MHD activity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...