1.
Rep Pract Oncol Radiother ; 26(6): 899-905, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34992861

RESUMO

BACKGROUND: The present paper reports on analysis of 184 patients who were diagnosed with endometrial cancer. The main objective of this study was to address parameter Vrec(30Gy) which determines a volume of the rectum irradiated with a dose of 30 Gy during radiotherapy. MATERIALS AND METHODS: All patients were irradiated with an IMRT technique on linear accelerators. The planning target volume (PTV) contour was determined by a radiation oncologist. The clinical target volume (CTV) was drawn on CT images obtained in a prone position. For statistical analysis, appropriate tests (e.g. the Shapiro-Wilk, Wilcoxon) were used. RESULTS AND DISCUSSION: The performed analysis showed that the recommended condition for Vrec(30Gy) is met only in 3% of patients and the observed median value exceeds 90%. The obtained results were compared with the studies in which the Vrec(30Gy) values were related to various radiotherapy techniques. CONCLUSIONS: The analysis showed that the condition for Vrec(30Gy) is satisfied in the case of only 3% of patients. Due to the difficulty with meeting the condition, it should be reconsidered based on real results.