Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Comput Tomogr ; 10(2): 162-72, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26732861

RESUMO

BACKGROUND: Transcatheter interventions are currently undertaken using "generic" fluoroscopic viewing angles. However, the position and orientation of heart structures may vary across patients and disease-specific remodeling processes. OBJECTIVE: This study uses multislice computed tomography to determine optimal fluoroscopic viewing angles of the aortic and mitral annuli, the left atrial appendage and the atrial septum. We explored differences between patients with severe aortic stenosis (AS) and severe mitral regurgitation (MR). METHODS AND RESULTS: The multislice computed tomographies of 28 patients with severe aortic stenosis (AS) and 32 patients with severe functional mitral regurgitation (MR) were analyzed. For each patient, we evaluated the optimal fluoroscopic viewing angles of the aortic and mitral annuli (en face, maximal and minimal diameters, aortic root with right, left and non coronary sinus in center), left atrial appendage orifice (en face, maximal and minimal diameters), and atrial septum (fossa ovalis) en face. The TAVR implantation view with right coronary sinus in center was LAO 9 - CRA 0 in the AS group and LAO 6 - CAU 5 in the MR group (p = NS). AS and MR patients differed significantly with respect to the fluoroscopic angulation of the aortic annulus en face (8.3°), the aortic annulus maximal (17.7°) and minimal (18.5°) diameters, the mitral annulus aorto-mural diameter (11.3°), and the left atrial appendage orifice en face (11.1°) (all p-values<0.05). CONCLUSION: Optimal fluoroscopic viewing angles of left-sided structures vary considerably between patients. Multislice computed tomography is a valuable tool to determine the most procedurally relevant angulations, with the potential to optimize procedural safety, efficacy and duration.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Apêndice Atrial/diagnóstico por imagem , Septo Interatrial/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Diagnóstico Diferencial , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/terapia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...