Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1172: 338673, 2021 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-34119025

RESUMO

In this work, a new gas chromatography-high-resolution mass spectrometry (GC-HRMS) method based on atmospheric pressure photoionisation (APPI) has been developed for the accurate determination of short-chain chlorinated paraffins (SCCPs) as a reliable alternative to the established methods. To the best of our knowledge, this is the first time these compounds has been analysed by GC-MS using atmospheric pressure photoionisation (APPI). Efficient ionisation of SCCPs was achieved using the new GC-APPI source by the formation of [M+Cl]- adduct ions in negative ion mode using dopant-assisted APPI with a mixture of acetone/CCl4 (3:1, v/v). Operating at a resolution of 70,000 FWHM (full width at half maximum) and monitoring the [M+Cl]- adduct ions for each congener group, a selective determination of the SCCPs was achieved, avoiding isobaric interferences between homologue groups with different carbon chain length and chlorination degree. Moreover, the GC-APPI-HRMS response of each congener group was mainly influenced by its concentration and did not depend on the number of chlorine atoms in the molecule as occurs with the GC-MS methods based on the electron-capture negative ionisation (ECNI). Thus, the contribution of the different carbon and chlorine homologue groups in the SCCP mixtures was determined by the internal normalization method, and the quantification was performed independently of the chlorine content of the SCCP standard mixture employed. The developed GC-APPI-HRMS method offers some interesting advantages over the existing methods, particularly the possibility to quantify individual SCCP congener groups, the use of a simple calibration method for quantification, and an important time-saving in the data processing, especially over ECNI-based traditional methods. The GC-APPI-HRMS method allowed the determination of SCCPs at low concentration levels in fish samples with low method limits of detection (17-34 pg g-1 wet weight for total SCCPs), good precision (RSD < 7%) and trueness (relative error < 8%) and can be proposed as a reliable alternative of the established methods for the determination of these pollutants in environmental samples.

2.
Talanta ; 194: 350-356, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30609542

RESUMO

In this work, we tested the potential of desorption electrospray ionization-high resolution mass spectrometry (DESI-HRMS) for the analysis of unknown materials. To this end, our study focused on analyzing an unknown complex sample suspected of being an adulterated phytosanitary product or a fraud. A simple and fast sample manipulation procedure (filter paper impregnated with the sample) was used for the chemical characterization of the phytosanitary product by DESI-HRMS(/MS). Kendrick Mass Defect (KMD) analysis was used to process the DESI high-resolution mass spectral data, allowing the identification of a low molecular weight polymer (polyethylene glycol) and the detection of other ions, which did not follow polymer distributions. The characteristic isotope patterns of these ions suggested the presence of organometallic compounds. Accurate mass measurements, isotope pattern fits and the structural information obtained by DESI-MS/HRMS (wide isolation window) allowed identifying the presence of triphenyltin, a biocide extensively used for agricultural purposes and restricted by the European Commission, in the phytosanitary product. The concentration of triphenyltin in the sample was 35%, which corresponds to ∼12% expressed as weight of tin, 120 times higher than the maximum legislated level.

3.
Hum Reprod ; 30(5): 1059-68, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25743783

RESUMO

STUDY QUESTION: Are the levels of biologically active and the most toxic dioxin-like substances in adipose tissue of patients with deep infiltrating endometriosis (DIE) higher than in a control group without endometriosis? SUMMARY ANSWER: DIE patients have higher levels of dioxins and polychlorinated biphenyls (PCBs) in adipose tissue compared with controls without endometriosis. WHAT IS KNOWN ALREADY: Some studies have investigated the levels of dioxin-like substances, in serum samples, in patients with endometriosis, with inconsistent results. STUDY DESIGN, SIZE, DURATION: Case-control study including two groups of patients. The study group (DIE group) consisted of 30 patients undergoing laparoscopic surgery because of DIE. In all patients, an extensive preoperative work-up was performed including clinical exploration, magnetic resonance imaging (MRI) and transvaginal sonography. All patients with DIE underwent a confirmatory histological study for DIE after surgery. The non-endometriosis control group (control group), included the next consecutive patient undergoing laparoscopic surgery in our center due to adnexal benign gynecological disease (ovarian or tubal procedures other than endometriosis) after each DIE patient, and who did not present any type of endometriosis. PARTICIPANTS/MATERIALS, SETTING, METHODS: During the surgical procedure 1-2 g of adipose tissue from the omentum were obtained. Dioxin-like substances were analyzed in adipose tissue in DIE patients and controls without endometriosis. MAIN RESULTS AND THE ROLE OF CHANCE: The total toxic equivalence and concentrations of both dioxins and PCBs were significantly higher in patients with DIE in comparison with the control group (P < 0.05), mainly due to the significantly higher values of the two most toxic dioxins (2,3,7,8-tetrachlorodibenzo-p-dioxin [2,3,7,8-TCDD] and 1,2,3,7,8-pentachlorodibenzo-p-dioxin [1,2,3,7,8-PeCDD]) (P < 0.01 for each compound). The levels of furan 2,3,4,7,8-PeCDF were statistically higher in the DIE group compared with controls. Only four congeners of PCBs had toxic equivalence values and concentrations that were statistically higher in patients with DIE, but these included the most toxic and carcinogenic PCB-126 (PCB-114 P < 0.05; PCB-156 P < 0.05; PCB-189 P = 0.04; PCB-126 P < 0.01). LIMITATIONS, REASONS FOR CAUTION: Since few patients were recruited, the study is only exploratory. Our results need to be confirmed in larger and more heterogeneous population studies since environmental and even genetic factors involved in determining dioxins and PCBs widely vary in different countries. Furthermore, the strict eligibility criteria used may preclude generalization of the results to other populations and the surgery-based sampling frame may induce a selection bias. Finally, adipose tissue was obtained only from the omentum, and not from other adipose tissue of the body. WIDER IMPLICATIONS OF THE FINDINGS: Our results suggest a potential role of dioxin-like substances in the pathogenesis of DIE. Further studies are warranted to confirm our findings. STUDY FUNDING/COMPETING INTERESTS: None. TRIAL REGISTRATION NUMBER: Not applicable.


Assuntos
Tecido Adiposo/química , Dioxinas/análise , Endometriose/fisiopatologia , Bifenilos Policlorados/análise , Adolescente , Adulto , Benzofuranos/análise , Índice de Massa Corporal , Estudos de Casos e Controles , Endometriose/metabolismo , Feminino , Humanos , Laparoscopia , Limite de Detecção , Imageamento por Ressonância Magnética , Ultrassonografia , Vagina/diagnóstico por imagem , Adulto Jovem
4.
Talanta ; 118: 245-52, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24274295

RESUMO

In the present work, a simple and fast method for the analysis of linear and cyclic methylsiloxanes in ambient air based on active sampling combined with gas chromatography - mass spectrometry (GC-MS) was developed. The retention efficiency of five sampling sorbents (activated coconut charcoal, Carbopack B, Cromosorb 102, Cromosorb 106 and Isolute ENV+) was evaluated and Isolute ENV+ was found to be the most effective. A volume of 2700 L of air can be sampled without significant losses of the most volatile methylsiloxanes. To improve the sensitivity of the GC-MS method, concurrent solvent recondensation - large volume injection (CSR-LVI), using volumes up to 30 µl of sample extract, is proposed and limits of quantification down to 0.03-0.45 ng m(-3), good linearity (r>0.999) and precision (RSD %<9%) were obtained. The developed method was applied to the analysis of ambient air. Concentrations of linear and cyclic methylsiloxanes in indoor air ranging from 3.9 to 319 ng m(-3) and between 48 and 292668 ng m(-3), were obtained, respectively, while levels from 6 to 22 ng m(-3) for linear and between 2.2 and 439 ng m(-3) for cyclic methylsiloxanes in outdoor air from Barcelona (Spain), were found.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental , Análise de Injeção de Fluxo/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Siloxanas/análise , Solventes/química , Humanos , Limite de Detecção , Espanha
5.
Chemosphere ; 93(3): 499-505, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23859426

RESUMO

The results of a surveillance programme on the determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and short chain chlorinated paraffins (SCCPs) in marine fish and shellfish species which are fished, commercialised and consumed in the Ebro River Delta area (NE, Spain) are presented. The study included the analysis of five marine fish species (sardine, gilthead sea bream, conger, eel and flounder) and three shellfish species (murex, carpet shell and mussel) collected in 2012 in five fishing harbours near to this area. WHO-TEQ concentrations for PCDD/Fs and dioxin like PCBs (dl-PCBs) ranged from 0.03 to 0.31 pg WHO-TEQ2005PCDD/Fg(-1)wetweight (ww) and from 0.02 to 3.15 pg WHO-TEQ2005PCBg(-1)ww, respectively. All levels were below the maximum concentrations established by the EU Regulation. The PCBs and PCDD/Fs accumulation pattern found in the samples analysed showed a distribution typically reported for marine samples. For marker PCBs and PBDEs, concentration levels ranging from 929 to 57494 pg g(-1)ww and from 36.2 to 827 pg g(-1)ww were obtained, respectively, meanwhile for SCCPs levels were between 3.1 and 141 ng g(-1)ww. Finally, the trends in the levels of PCDD/F and dl-PCBs found from 2006 to 2012 in fish and shellfish species were studied. A slight decrease of PCDD/F and dl-PCB concentrations was found since 2006.


Assuntos
Exposição Ambiental , Peixes/metabolismo , Moluscos/metabolismo , Alimentos Marinhos/análise , Poluentes Químicos da Água/metabolismo , Animais , Benzofuranos/metabolismo , Dibenzofuranos Policlorados , Monitoramento Ambiental , Estuários , Produtos Pesqueiros/análise , Cromatografia Gasosa-Espectrometria de Massas , Éteres Difenil Halogenados/metabolismo , Hidrocarbonetos Clorados/metabolismo , Estações do Ano , Espanha
6.
Anal Chim Acta ; 782: 28-36, 2013 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-23708281

RESUMO

Naphthylacetic acid, naphthyloxy acetic acid and naphthylacetamide belong to a group of synthetic substances known as "auxin-like" compounds which are used as growth regulators in vegetables and fruits due to their structure similarities with the indoleacetic acid, the most important plant auxin. This paper reports a selective, sensitive and fast ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for the determination of naphthylacetamide (NAD) and the isomers (α and ß) of naphthylacetic acid (NAA) and naphthyloxy acetic (NOA) acid in apple samples. A baseline separation between the respective isomers was achieved using an RP-Amide column with gradient elution. The UHPLC-MS/MS method developed, using electrospray and selected reaction monitoring (SRM) acquisition mode led to a reliable determination of these family of compounds in apple samples at low quantitation levels, down to 1.0 µg kg(-1) and 0.25 µg kg(-1) respectively. For confirmation of NAA accurate mass measurement is proposed giving at these conditions quantitation limits of 10 µg kg(-1) for this compound. The UHPLC-MS/MS method developed was used for the analysis of apple samples harvested in three different apple fields from Lleida (Spain) during the blooming period. NAD and NAA were found in samples collected during 4-5 weeks after application at concentrations between the quantification limits and 43 µg kg(-1) and 24 µg kg(-1), respectively.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Análise de Alimentos/métodos , Malus/química , Naftalenos/análise , Espectrometria de Massas em Tandem/métodos , Fracionamento Químico , Cromatografia Líquida de Alta Pressão/instrumentação , Glicolatos/análise , Limite de Detecção , Ácidos Naftalenoacéticos/análise , Reguladores de Crescimento de Plantas/análise , Sensibilidade e Especificidade , Solventes/química , Espanha
7.
J Proteomics ; 78: 159-71, 2013 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-23178873

RESUMO

Pentachlorophenol (PCP) represents a critical concern worldwide due to its toxicity and recalcitrance to degradation. The capacity of Mucor plumbeus to transform PCP into several detoxification metabolites, including tetrachlorohydroquinone and several phase II conjugates, was observed by LC-HRMS. The data obtained support the degradation pathway proposed previously. PCP effects in M. plumbeus, an unsequenced species, were investigated using a proteomics approach (bidimensional gel electrophoresis followed by MALDI TOF/TOF analyses). The mycelial proteins identified in the differentially accumulated spots allowed the identification of PCP responsive proteins. The presence of PCP increased the energy demand, altered the cell wall architecture and cytoskeleton and induced a significant stress response. The latter was emphasised by the up-accumulation of protein species associated with defence mechanisms (e.g. HSP70 and cytochrome c peroxidase). Overall the data produced corroborate the capability of PCP to uncouple oxidative-phosphorylation in mitochondria. Importantly, one of the identified mycelial protein species, a NAD- and Zn-dependent ADH, is likely to be involved in PCP degradation. Amongst the fungal secretome analysed, no putative PCP degradative enzymes were detected. This work constitutes the first toxicoproteomic study involving a Zygomycota fungus and the very first concerning the effect of PCP in a fungal proteome.


Assuntos
Poluentes Ambientais/farmacologia , Proteínas Fúngicas/metabolismo , Mucor/metabolismo , Pentaclorofenol/farmacologia , Proteômica , Biotransformação/efeitos dos fármacos , Biotransformação/fisiologia , Poluentes Ambientais/metabolismo , Pentaclorofenol/metabolismo , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
8.
J Chromatogr A ; 1268: 150-6, 2012 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-23141621

RESUMO

Concurrent solvent recondensation-large volume injection (CSR-LVI) is a gas chromatography injection technique that is particularly suitable for determining volatile compounds. In the present work, we evaluated the applicability of this technique for the analysis of linear and cyclic methylsiloxanes in sewage sludges and soils after solvent extraction to prevent losses of low-molecular-weight compounds. The CSR-LVI injection method was optimised to achieve maximum sensitivity and good chromatographic peak shapes. A liner packed with deactivated glass wool and a 5 m × 0.32 mm I.D. uncoated fused-silica precolumn was used. This made it possible to inject extract volumes of up to 30 µl. Good linearity (r>0.9993) and precision (RSD <15%), with recoveries ranging from 80 to 100% and method limits of quantification from 0.03 to 0.4 ng g(-1) wet weight (0.04-1.5 ng g(-1) dry weight for sewage sludges and 0.01-0.5 ng g(-1) dry weight for soils) were obtained. The developed method was applied to the analysis of linear and cyclic methylsiloxanes in sewage sludges collected from several wastewater treatment plants in Catalonia (NE Spain) and urban soils from the city of Barcelona.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Esgotos/análise , Siloxanas/química , Poluentes do Solo/química , Poluentes Químicos da Água/química , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Estrutura Molecular
9.
Talanta ; 89: 63-9, 2012 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-22284460

RESUMO

This paper proposes a new method for the analysis of linear and cyclic methylsiloxanes in water samples based on headspace-solid phase microextraction (HS-SPME) coupled to gas chromatography-mass spectrometry (GC-MS). The extraction efficiency of four commercially available SPME-fibres was evaluated and it was found that a 65 µm polydimethylsiloxane/divinylbenzene (PDMS/DVB) coating was the most suitable for the extraction of siloxanes. The method provided good linearity (r>0.999) and precision (RSD % <17%), and low limits of quantification ranging from 0.01 to 0.74 ng L(-1) for linear siloxanes and between 18 and 34 ng L(-1) for cyclic siloxanes. The HS-SPME-GC-MS method was applied to the analysis of linear and cyclic siloxanes in river waters from Catalonia (NE, Spain) and the results showed concentrations of linear and cyclic siloxanes ranging from 0.09 to 3.94 ng L(-1) and 22.2 to 58.5 ng L(-1), respectively.


Assuntos
Dimetilpolisiloxanos/química , Água Doce/química , Polivinil/química , Siloxanas/análise , Poluentes Químicos da Água/análise , Cromatografia Gasosa-Espectrometria de Massas , Rios , Sensibilidade e Especificidade , Microextração em Fase Sólida/métodos , Espanha
10.
Talanta ; 86: 329-36, 2011 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-22063548

RESUMO

Residues of perfluorinated phosphonic acids (PFPAs) and perfluorooctane sulfonic acid (PFOS) were investigated in various Dutch surface waters, sludge and sediments. For this purpose, a liquid chromatographic (LC) method was optimized by testing several columns with different mobile phases. Atmospheric pressure chemical ionization (APCI) was chosen for the LC tandem mass spectrometry (MS/MS) analysis. An ion-pair reagent was added to the injection solvent to improve peak shape. Different solvents were studied for the extraction from solid samples. For clean-up and pre-concentration, weak anion-exchange solid-phase extraction cartridges were used. Water samples were extracted using the same cartridges. The method was used for screening PFPAs in the Dutch aquatic environment. PFPAs were not observed in sediment or sludge samples. PFOPA was found at 1 ng L(-1) in one surface water sample. PFOS was found at levels between 0.07 ng g(-1) and 48 ng g(-1) (dry weight) in sediments and sewage sludge samples. PFOS concentrations in surface water ranged from 3.3 ng L(-1) to 25.4 ng L(-1).


Assuntos
Ácidos Alcanossulfônicos/análise , Fluorocarbonos/análise , Sedimentos Geológicos/análise , Organofosfonatos/análise , Esgotos/análise , Espectrometria de Massas em Tandem/métodos , Água/análise , Cromatografia Líquida/métodos
11.
Rapid Commun Mass Spectrom ; 25(20): 3161-6, 2011 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-21953972

RESUMO

Benzophenone (BP) is one of the many contaminants reported as present in foodstuffs due to its migration from food packaging materials. Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is acknowledged in the literature as the method of choice for this analysis. However, cases have been reported where the use of this methodology was insufficient to unambiguously confirm the presence of a contaminant. In previous work performed by the authors, the unequivocal identification of BP in packaged foods was not possible even when monitoring two m/z transitions (precursor ion - product ion), since ion ratio errors higher than 20% were obtained. In order to overcome this analytical problem a fast, sensitive and selective liquid chromatography/high-resolution mass spectrometry (LC/HRMS) methodology has been developed and applied to the analysis of BP in packaged foods. A direct comparison between LC/HRMS and LC/MS/MS data indicated better selectivity when working with LC/HRMS at a resolving power of 50,000 FWHM (full width at half maximum) than when monitoring two m/z transitions by LC/MS/MS. The resolving power used enabled the detection and identification of Harman as the compound impeding the confirmation of BP by LC-MS/MS. Similar quantitative results were obtained by an Orbitrap mass analyser (Exactive™) and a triple quadrupole mass analyser (TSQ Quantum Ultra AM™).


Assuntos
Benzofenonas/análise , Análise de Alimentos/métodos , Análise de Alimentos/normas , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Animais , Bebidas/análise , Bovinos , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Embalagem de Alimentos , Alimentos Infantis/análise , Leite/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Leite de Soja/química
12.
Talanta ; 84(4): 1155-62, 2011 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-21530792

RESUMO

This paper describes a fast and simple pressurized liquid extraction (PLE) method combined with gas chromatography coupled to ion trap tandem mass spectrometry (GC-ITMS-MS) for the determination of polybrominated biphenyls (PBBs) in fish samples. The method is based on a simultaneous extraction/clean-up step to reduce analysis time and solvent consumption. The effect of several PLE operating conditions, such as solvent type, extraction temperature and time, number of cycles, and lipid retainer, was optimized to obtain maximum recovery of the analytes with the minimum presence of matrix-interfering compounds. The best conditions were obtained at 100°C with n-hexane using 15 g of silica modified with sulphuric acid (44%, w/w) as sorbent for lipid removal. Quality parameters of the GC-ITMS-MS method were established, achieving good linearity (r>0.998), between 1 and 500 ng ml(-1), and low instrumental limits of detection (0.14-0.76 pg injected). For the whole method, limits of detection ranging from 0.03 to 0.16 ng g(-1) wet weight and good precision (RSD<16%) were obtained.


Assuntos
Fracionamento Químico/métodos , Recuperação e Remediação Ambiental/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Bifenil Polibromatos/análise , Bifenil Polibromatos/isolamento & purificação , Pressão , Espectrometria de Massas em Tandem/métodos , Animais , Poluentes Ambientais/análise , Poluentes Ambientais/isolamento & purificação , Peixes , Fatores de Tempo
13.
J Chromatogr A ; 1218(30): 4828-33, 2011 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-21356538

RESUMO

A method is proposed for the clean-up and preconcentration of natural and synthetic estrogens from aqueous samples employing molecularly imprinted polymer (MIP) as selective sorbent for solid-phase extraction (SPE). The selectivity of the MIP was checked toward several selected natural and synthetic estrogens such as estrone (E1), 17ß-estradiol (ß-E2), 17α-estradiol (α-E2), estriol (E3), 17α-ethinylestradiol (EE2), dienestrol (DIES) and diethylstilbestrol (DES). Ultrahigh pressure liquid chromatography (UHPLC) coupled to a TSQ triple quadrupole mass spectrometry (QqQ) was used for analysis of target analytes. The chromatographic separation of the selected compounds was performed in less than 2 min under isocratic conditions. The method was applied to the analysis of estrogens in spiked river and tap water samples. High recoveries (>82%) for estrone, 17ß-estradiol, 17α-estradiol, estriol and 17α-ethinylestradiol were obtained. Lower but still satisfactory recoveries (>48%) were achieved for dienestrol and diethylstilbestrol. The method was validated and found to be linear in the range 50-500 ng L(-1) with correlation coefficients (R(2)) greater than 0.995 and repeatability relative standard deviation (RSD) below 8% in all cases. For analysis of 100-mL sample, the method detection limits (LOD) ranged from 4.5 to 9.8 ng L(-1) and the limit of quantitation (LOQ) from 14.9 to 32.6 ng L(-1). To demonstrate the potential of the MIP obtained, a comparison with commercially available C(18) SPE was performed. Molecularly imprinted SPE showed higher recoveries than commercially available C(18) SPE for most of the compounds. These results showed the suitability of the MIP-SPE method for the selective extraction of a class of structurally related compounds such as natural and synthetic estrogens.


Assuntos
Congêneres do Estradiol/isolamento & purificação , Estrogênios/isolamento & purificação , Impressão Molecular/métodos , Extração em Fase Sólida/métodos , Poluentes Químicos da Água/isolamento & purificação , Cromatografia Líquida de Alta Pressão , Congêneres do Estradiol/análise , Congêneres do Estradiol/química , Estrogênios/análise , Estrogênios/química , Modelos Lineares , Espectrometria de Massas , Reprodutibilidade dos Testes , Rios/química , Sensibilidade e Especificidade , Água/química , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/química
14.
J Chromatogr A ; 1218(12): 1603-10, 2011 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-21333297

RESUMO

In this work a fast liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method using a C18 Fused Core™ column, was developed for the simultaneous analysis of bisphenol A diglycidyl ether (BADGE), bisphenol A (2,3-dihydroxypropyl) glycidyl ether (BADGE·H(2)O), bisphenol A bis(2,3-dihydroxypropyl) ether (BADGE·2H(2)O), bisphenol A (3-chloro-2-hydroxypropyl) glycidyl ether (BADGE·HCl), bisphenol A bis(3-chloro-2-hydroxypropyl) ether (BADGE·2HCl) and bisphenol A (3-chloro-2-hydroxypropyl)(2,3-dihydroxypropyl ether) (BADGE·HCl·H(2)O) and bisphenol F diglycidyl ether (BFDGE), bisphenol F bis(2,3-dihydroxypropyl) ether (BFDGE·2H(2)O), bisphenol F bis(3-chloro-2-hydroxypropyl) ether (BFDGE·2HCl). The LC method was coupled with a triple quadrupole mass spectrometer, using an ESI source in positive mode and using the [M+NH(4)](+) adduct as precursor ion for tandem mass spectrometry experiments. The method developed was applied to the determination of these compounds in canned soft drinks and canned food. OASIS HLB solid phase extraction (SPE) cartridges were used for the analysis of soft drinks, while solid canned food was extracted with ethyl acetate. Method limits of quantitation ranged from 0.13 µgL(-1) to 1.6 µgL(-1) in soft drinks and 1.0 µgkg(-1) to 4.0 µgkg(-1) in food samples. BADGE·2H(2)O was detected in all the analyzed samples, while other BADGEs such as BADGE·H(2)O, BADGE·HCl·H(2)O, BADGE·HCl and BADGE·2HCl were also detected in canned foods.


Assuntos
Bebidas Gaseificadas/análise , Cromatografia Líquida/métodos , Compostos de Epóxi/análise , Alimentos em Conserva/análise , Espectrometria de Massas em Tandem/métodos , Compostos Benzidrílicos , Análise de Alimentos/métodos , Extração em Fase Sólida
15.
Food Chem ; 126(4): 1527-32, 2011 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-25213922

RESUMO

In this work, we evaluated the occurrence of furan in brews obtained from regular, decaffeinated, and instant coffee and commercial packed capsules. For this purpose, a previously developed automated headspace solid-phase microextraction method coupled to gas chromatography-mass spectrometry (HS-SPME-GC-MS) was used. Initially, the influence of HS-SPME conditions on furan formation was evaluated. In addition, the effect of roasting conditions (temperature and time) used for coffee beans on furan formation was also studied. We found that low temperature and long roasting time (140°C and 20min) decreases the final furan content. Furan concentrations in regular ground coffee brews from an espresso coffee machine were higher (43-146ng/ml) than those obtained from a home drip coffee maker (20 and 78ng/ml), while decaffeinated coffee brews from a home drip coffee maker (14-65ng/ml) showed a furan concentration similar to that obtained from regular coffee. Relatively low concentrations of this compound (12-35ng/ml) were found in instant coffee brews, while commercial packed coffee capsules showed the highest concentrations (117-244ng/ml). Finally, the daily intake of furan through coffee consumption in Barcelona (Spain) (0.03-0.38µg/kg of body weight) was estimated.

16.
Anal Chim Acta ; 683(2): 227-33, 2011 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-21167975

RESUMO

In this study, an automated on-line solid-phase extraction coupled to fast liquid chromatography-tandem mass spectrometry (on-line SPE fast LC-MS/MS) method was developed for the simultaneous analysis of bisphenol A (BPA), bisphenol F (BPF), bisphenol E (BPE), bisphenol B (BPB) and bisphenol S (BPS) in canned soft drinks without any previous sample treatment. A C18 (12 µm particle size) loading column was used for the SPE on-line preconcentration before the liquid chromatography baseline separation of bisphenol compounds using a C18 Fused-Core™ (50 mm × 2.1 mm i.d.) column, which took less than 3 min. Gradient elution and heated electrospray were used to reduce matrix effect and improve ionization efficiency. To select the most intense and selective transitions, fragmentation studies were performed by multiple-stage mass spectrometry in an ion trap mass analyzer and tandem mass spectrometry in a triple quadrupole instrument, this latter instrument being used for quantitation in SRM mode. Quality parameters of the method were established and we obtained a simple, fast, reproducible (RSD values lower than 10%) and accurate (precision higher than 93%) method for the analysis of bisphenols in canned soft drinks at the ng L(-1) level using matrix-matched calibration.

17.
Rapid Commun Mass Spectrom ; 25(2): 379-86, 2011 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-21192033

RESUMO

We report a selective, sensitive and fast liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of diallyldimethylammonium chloride (DADMAC) in water. Hydrophilic interaction liquid chromatography (HILIC) was used to avoid ion-pairing reagents, which are generally employed to retain cationic compounds. The complementary information obtained in a triple quadrupole mass spectrometer and in an ion trap Orbitrap has been used to study the fragmentation of the DADMAC cation [M](+) and for the correct assignment of the products ions. The HILIC/MS/MS method developed, using electrospray ionization in positive ion mode and selected reaction monitoring (SRM) acquisition mode, led to a reliable determination and confirmation of the DADMAC cation in water samples down to 50 ng L(-1). The low detection limit achieved, in combination with the absence of matrix effects, allowed the direct analysis of samples without any pretreatment, preconcentration or clean-up step. DADMAC was determined in samples collected in a drinking water treatment plant (DWTP) in Barcelona (Spain) and it was found in the influent at the µg L(-1) level.

18.
J Chromatogr A ; 1218(1): 74-82, 2011 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-21122868

RESUMO

An analytical HPLC-MS screening methodology has been developed to improve preparative RP-HPLC-MS purifications in medicinal chemistry laboratories. Although several approaches have been previously described to optimize analytical separations, none of them met our needs for the optimization of preparative conditions. Our screening protocol is based on searching among several orthogonal conditions to find the optimum preparative separation. Five different buffer conditions, from low to high pH, two organic solvents, acetonitrile and methanol, and five stationary phases of different polarities and characteristics were used. The orthogonality of the system was demonstrated using both, a standard mixture and mixtures from synthesis. To carry out the screening one of the analytical "open access" HPLC-MS systems was modified to perform the analytical screening while maintaining the open-access functionality for synthesis reaction monitoring. A software tool for automated sample programming and data reporting was also developed.


Assuntos
Química Farmacêutica/métodos , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Acetonitrilas/química , Acetonitrilas/isolamento & purificação , Soluções Tampão , Cromatografia Líquida de Alta Pressão/instrumentação , Concentração de Íons de Hidrogênio , Espectrometria de Massas/instrumentação , Metanol/química , Metanol/isolamento & purificação , Modelos Químicos , Compostos Orgânicos/química , Compostos Orgânicos/isolamento & purificação , Preparações Farmacêuticas/química , Preparações Farmacêuticas/isolamento & purificação , Reprodutibilidade dos Testes , Software
19.
Rapid Commun Mass Spectrom ; 24(23): 3469-77, 2010 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-21072804

RESUMO

The fragmentation of bisphenol A diglycidyl ether (BADGE), bisphenol F diglycidyl ether (BFDGE) and their derivatives was studied by electrospray ionization tandem mass spectrometry. Multiple-stage mass spectrometry and accurate mass measurements were combined to establish the fragmentation pathways. BADGEs and BFDGEs tend to form ammonium adducts under electrospray conditions which fragmented easily. The fragmentation of [M+NH(4)](+) for BADGEs started with the cleavage of the phenyl-alkyl bond, which was followed by the α-cleavage of the ether group to generate the characteristic product ions at m/z 135, [C(9)H(11)O](+), and m/z 107, [C(7)H(7)O](+). The fragmentation of the BFDGE isomer mixtures was studied by on-line reversed-phase liquid chromatography coupled to multiple-stage mass spectrometry (LC/MS(n)). Information obtained from product ion spectra for each BFDGE isomer and its comparison with the fragmentation pathway of BADGE allowed each isomer and the chromatographic elution order to be identified.

20.
Anal Chim Acta ; 678(1): 73-81, 2010 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-20869507

RESUMO

A one-step extraction and clean-up method using pressurized liquid extraction (PLE) (selective PLE) combined with gas chromatography-ion-trap tandem mass spectrometry (GC-ITMS-MS) was evaluated for the analysis of polybrominated diphenyl ethers (from tri- to hepta-PBDEs) at low concentrations in fish and shellfish samples. To this end, the performance of an on-line PLE extraction/clean-up method and of a classical Soxhlet extraction and clean-up method using a multi-layer modified silica column were compared. The two sample treatment methods provided similar results, although an important reduction in the sample treatment time (40 min per sample) was achieved using the selective PLE method. In addition, the suitability of the PLE combined with GC-ITMS-MS method was evaluated by comparing the results obtained in the analysis of fish samples with those obtained by gas chromatography-high resolution mass spectrometry (GC-HRMS). Good agreement between both techniques was obtained with differences between the mean values of less than 16%. The selective PLE method coupled to GC-ITMS-MS produced accurate results for PBDE determination with low limits of detection (1.0-16.8 pg g(-1) wet weight) and quantification (3.1-51 pg g(-1) wet weight) as well as good precision (RSD<16%). This method has been applied to the analysis of PBDEs in fish and shellfish samples collected at fish markets in Catalonia (NE Spain).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...