Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Heart ; 110(4): 263-270, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37607813

RESUMO

OBJECTIVES: To develop a tool including exercise electrocardiography (ExECG) for patient-specific clinical likelihood estimation of patients with suspected obstructive coronary artery disease (CAD). METHODS: An ExECG-weighted clinical likelihood (ExECG-CL) model was developed in a training cohort of patients with suspected obstructive CAD undergoing ExECG. Next, the ExECG-CL model was applied in a CAD validation cohort undergoing ExECG and clinically driven invasive coronary angiography and a prognosis validation cohort and compared with the risk factor-weighted clinical likelihood (RF-CL) model for obstructive CAD discrimination and prognostication, respectively.In the CAD validation cohort, obstructive CAD was defined as >50% diameter stenosis on invasive coronary angiography. For prognosis, the endpoint was non-fatal myocardial infarction and death. RESULTS: The training cohort consisted of 1214 patients (mean age 57 years, 57% males). In the CAD (N=408; mean age 55 years, 53% males) and prognosis validation (N=3283; mean age 57 years, 57% males) cohorts, 11.8% patients had obstructive CAD and 4.4% met the endpoint. In the CAD validation cohort, discrimination of obstructive CAD was similar between the ExECG-CL and RF-CL models: area under the receiver-operating characteristic curves 83.1% (95% CIs 77.5% to 88.7%) versus 80.7% (95% CI 74.6% to 86.8%), p=0.14. In the ExECG-CL model, more patients had very low (≤5%) clinical likelihood of obstructive CAD compared with the RF-CL (42.2% vs 36.0%, p<0.01) where obstructive CAD prevalence and event risk remained low. CONCLUSIONS: ExECG incorporated into a clinical likelihood model improves reclassification of patients to a very low clinical likelihood group with very low prevalence of obstructive CAD and favourable prognosis.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Teste de Esforço , Eletrocardiografia , Angiografia Coronária , Fatores de Risco , Medição de Risco , Valor Preditivo dos Testes
2.
Am J Cardiol ; 171: 84-90, 2022 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-35277254

RESUMO

This study sought to investigate gender differences in clinical presentation, presence, and extent of coronary artery disease (CAD), and all-cause mortality in patients with stable chest pain who underwent coronary computed tomography angiography (CCTA). Patients who visited the fast-track outpatient clinic of the Erasmus Medical Center and underwent CCTA were analyzed. Clinical characteristics of chest pain, CAD on CCTA, coronary artery calcium scores, and survival were collected retrospectively and compared between men and women. Logistic regression was used to identify independent risk factors for the presence of CAD and Cox regression for all-cause mortality. In 1,835 included patients, 966 (52.6%) were female. Men and women were similar in age (55 vs 56 years). Compared with men, women had a lower frequency of typical pain (22.8% vs 31.1%, p <0.001), lower prevalence of significant CAD (22.2% vs 38.1%, p <0.001), and lower coronary artery calcium scores (p <0.001). CAD was more prevalent in men than in women with typical pain (67.4% vs 35.9%, p <0.001) and also with nontypical pain (24.9% vs 18.1%, p = 0.002). After adjustment for baseline characteristic, male sex was associated with all-cause mortality (adjusted hazard ratio 1.87, 95% confidence interval 1.25 to 2.80, p = 0.002). The additional risk of mortality because of CAD was similar between men and women. Stratifying by typical and nontypical pain, women again had a better prognosis. Our study identifies gender-related differences in characteristics, CCTA-findings, and outcomes for women compared with men presenting for CCTA with chest pain. Women have less CAD and a better prognosis than men, the clinical implications of which require further study.


Assuntos
Cálcio , Doença da Artéria Coronariana , Dor no Peito/epidemiologia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais
3.
Acta Cardiol ; 76(2): 185-193, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31920151

RESUMO

BACKGROUND: Elevated pulmonary artery pressure (PAP) in patients with severe aortic stenosis (AS) is a strong predictor of adverse prognosis. This study sought to assess the relation between PAP and clinical and echocardiographic parameters in elderly patients with severe AS, as well as to identify the determinants of the change in PAP after transcatheter aortic valve implantation (TAVI). METHODS: The study included 170 subjects (age 81 ± 7 years, 45% men) with symptomatic severe AS who were treated by TAVI. They underwent a clinical evaluation and a transthoracic echocardiography before the TAVI procedure and 6 months after. RESULTS: In a multivariable analysis, the independent predictors for baseline PAP were the body mass index (BMI) (ß = 0.21, p = .006), COPD GOLD class (ß = 0.20; p = .009), the E/e' ratio (ß = 0.20; p = .02) and the degree of aortic regurgitation (ß = 0.20; p = .01). After TAVI, there was significantly less (51% vs. 29%, p<.0001) pulmonary hypertension, defined as a tricuspid regurgitation velocity ≥2.8 m/s. The baseline variables related to an improvement in PAP were the tricuspid regurgitation velocity (p = .0001) and the E/e' (p = .005). From the parameters potentially modified with TAVI, the only independent predictor of PAP variation was the change in the E/e' ratio (ß = 0.23; p = .01). CONCLUSIONS: Independent predictors for baseline PAP in elderly patients with symptomatic AS were the BMI, GOLD class, the aortic regurgitation and the E/e' ratio. The baseline predictors for a change in PAP 6 months after TAVI were the baseline PAP and E/e', with only the change in the E/e' ratio being correlated to the change in PAP.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Pressão Arterial , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Artéria Pulmonar/diagnóstico por imagem
4.
Am J Cardiol ; 126: 16-22, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32345472

RESUMO

Identifying coronary artery disease (CAD) in atrial fibrillation (AF) patients improves risk stratification and defines clinical management. However, the value of screening for subclinical CAD with cardiac CT in AF patients is unknown. Between 2011 and 2015, 94 consecutive patients without known or suspected CAD (66 (57-73) years, 68% male), who were referred for AF evaluation, underwent a noncontrast-enhanced coronary calcium scan and a coronary computed tomography angiography (CCTA) at our center. We retrospectively evaluated the coronary calcium score, the prevalence of obstructive CAD (≥50% stenosis) determined by CCTA, compared clinical management and 5-year outcome in patients with and without obstructive CAD on CCTA, and examined the potential impact of a coronary calcium score and obstructive CAD on CCTA as a manifestation of vascular disease on the CHA2Ds2VASc score and for the cardiovascular risk stratification of AF patients. The median coronary calcium score was 57 (0-275) and 24 patients (26%) had obstructive CAD on CCTA. At baseline, patients with obstructive CAD more often used statins than those without obstructive CAD (54% vs 26%, p = 0.011). After a median clinical follow-up of 2.4 (0.5-4.5) years, patients with obstructive CAD more frequently used oral anticoagulant and/or antiplatelet drugs, statins, angiotensin-II-receptor blockers and/or angiotensin-converting-enzyme inhibitors, and less often used class I antiarrhythmic drugs than patients without obstructive CAD (all p <0.050). After a median follow-up of 5.7 (4.8-6.8) years, mortality was higher in patients with obstructive CAD than in those without obstructive CAD (29% vs 11%, log-rank test: p = 0.034). Implementation of a coronary calcium score and/or obstructive CAD on CCTA elevated the CHA2Ds2VASc score and cardiovascular risk stratification in 42 patients (p <0.001) and 47 patients (p = 0.006), respectively. In conclusion, we observed a high prevalence of obstructive CAD on CCTA in AF patients without known or suspected CAD. AF patients with obstructive CAD were managed differently and had a worse prognosis than those without obstructive CAD. Cardiac CT could enhance cardiovascular risk stratification of AF patients.


Assuntos
Fibrilação Atrial/epidemiologia , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/mortalidade , Estenose Coronária/mortalidade , Medição de Risco , Calcificação Vascular/diagnóstico por imagem , Idoso , Antagonistas de Receptores de Angiotensina/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Anticoagulantes/uso terapêutico , Fibrilação Atrial/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Feminino , Seguimentos , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Prognóstico , Estudos Retrospectivos , Calcificação Vascular/mortalidade , Calcificação Vascular/terapia
5.
Am J Cardiol ; 125(9): 1404-1412, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32111340

RESUMO

The etiology of chest pain in hypertrophic cardiomyopathy (HC) is diverse and includes coronary artery disease (CAD) as well as HC-specific causes. Myocardial bridging (MB) has been associated with HC, chest pain, and accelerated atherosclerosis. We compared HC patients with age-, gender- and CAD pre-test probability-matched outpatients presenting with chest pain to investigate differences in the presence of MB and CAD using coronary computed tomography angiography (CCTA). We studied 84 HC patients who underwent CCTA and compared these with 168 matched controls (age 54 ± 11 years, 70% men, pre-test probability 12% [5% to 32%]). MB, calcium score, plaque morphology and presence and extent of CAD were assessed for each patient. Linear mixed models were used to assess differences between cases and controls. MB was more often seen in HC patients (50% vs 25%, p <0.001). Calcium score and the presence of obstructive CAD were similar in both groups (9 [0 to 225] vs 4 [0 to 82] and 18% vs 19%; p = 0.22 and p = 0.82). In the HC group, MB was associated with pathogenic DNA variants (p = 0.04), but not with the presence of chest pain (74% vs 76%, p = 0.8), nor with worse outcome (log-rank p = 0.30). In conclusion, the prevalence and extent of CAD was equal among patients with and without HC, demonstrating that pre-test risk prediction using the CAD Consortium clinical risk score performs well in HC patients. MB was twice as prevalent in the HC group compared with matched controls, but was not associated with chest pain or decreased event-free survival in these patients.


Assuntos
Cardiomiopatia Hipertrófica/complicações , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/etiologia , Ponte Miocárdica/epidemiologia , Ponte Miocárdica/etiologia , Adulto , Idoso , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Dor no Peito/etiologia , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ponte Miocárdica/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
6.
Eur Radiol ; 30(7): 3692-3701, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32166492

RESUMO

OBJECTIVE: To determine the potential impact of on-site CT-derived fractional flow reserve (CT-FFR) on the diagnostic efficiency and effectiveness of coronary CT angiography (CCTA) in patients with obstructive coronary artery disease (CAD) on CCTA. METHODS: This observational cohort study included patients with suspected CAD who had been randomized to cardiac CT in the CRESCENT I and II trials. On-site CT-FFR was blindly performed in all patients with at least one ≥ 50% stenosis on CCTA and no exclusion criteria for CT-FFR. We retrospectively assessed the effect of adding CT-FFR to the CT protocol in patients with a stenosis ≥ 50% on CCTA in terms of diagnostic effectiveness, i.e., the number of additional tests required to determine the final diagnosis, reclassification of the initial management strategy, and invasive coronary angiography (ICA) efficiency, i.e., ICA rate without ≥ 50% CAD. RESULTS: Fifty-three patients out of the 372 patients (14%) had at least one ≥ 50% stenosis on CCTA of whom 42/53 patients (79%) had no exclusion criteria for CT-FFR. CT-FFR showed a hemodynamically significant stenosis (≤ 0.80) in 27/53 patients (51%). The availability of CT-FFR would have reduced the number of patients requiring additional testing by 57%-points compared with CCTA alone (37/53 vs. 7/53, p < 0.001). The initial management strategy would have changed for 30 patients (57%, p < 0.001). Reserving ICA for patients with a CT-FFR ≤ 0.80 would have reduced the number of ICA following CCTA by 13%-points (p = 0.016). CONCLUSION: Implementation of on-site CT-FFR may change management and improve diagnostic efficiency and effectiveness in patients with obstructive CAD on CCTA. KEY POINTS: • The availability of on-site CT-FFR in the diagnostic evaluation of patients with obstructive CAD on CCTA would have significantly reduced the number of patients requiring additional testing compared with CCTA alone. • The implementation of on-site CT-FFR would have changed the initial management strategy significantly in the patients with obstructive CAD on CCTA. • Restricting ICA to patients with a positive CT-FFR would have significantly reduced the ICA rate in patients with obstructive CAD on CCTA.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Aprendizado de Máquina , Idoso , Cateterismo Cardíaco , Estudos de Coortes , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Gerenciamento Clínico , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
7.
Radiology ; 286(1): 71-80, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28809582

RESUMO

Purpose To show that equal coronary lumen opacification can be achieved with iso- and low-osmolar contrast media when it is injected at the same iodine delivery rate with contemporary cardiac computed tomographic (CT) protocols and to investigate the cardiovascular effect of iso-osmolar contrast media and the image quality achieved. Materials and Methods Institutional review board approval and written informed consent were obtained for the Effect of Iso-osmolar Contrast Medium on Coronary Opacification and Heart Rhythm in Coronary CT Angiography, or IsoCOR, trial. Between November 2015 and August 2016, 306 patients (167 [55%] women) at least 18 years old (weight range, 50-125 kg), were prospectively randomized to receive iso-osmolar iodixanol 270 or low-osmolar iopromide 300 contrast media. All coronary segments were assessed for intraluminal opacification and image quality and were compared by using the Student t test. Heart rate, arrhythmia, patient discomfort, and adverse events also were monitored. Results Mean measured coronary attenuation values ± standard deviation were comparable between the iodixanol 270 and iopromide 300 contrast media groups (469 HU ± 167 vs 447 HU ± 166, respectively [P = .241]; 95% confidence interval: -15.1, 60.0), including those from subanalyses. Adjusted for the lower iodine concentration, the mean iodixanol 270 bolus was larger compared with that of iopromide 300 (76.8 mL ± 11.6 vs 69.7 mL ± 10.8, respectively; P < .001). The higher injection rate was associated with higher pressure (777 kPa ± 308 vs 630 kPa ± 252, respectively; P < .001). Although in the iodixanol 270 group patients experienced less heat discomfort (72% vs 86%, respectively; P < .001), no differences in heart rate or rhythm were observed. Conclusion If injected at comparable iodine delivery rates, the iso-osmolar contrast medium iodixanol 270 is not inferior to low-osmolar contrast medium iopromide 300 for assessment of coronary opacification. Iodixanol 270 was associated with less heat discomfort, but did not affect heart rate differently compared with iopromide 300. © RSNA, 2017 Online supplemental material is available for this article.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste/uso terapêutico , Angiografia Coronária , Iohexol/análogos & derivados , Ácidos Tri-Iodobenzoicos/uso terapêutico , Adulto , Pressão Sanguínea/efeitos dos fármacos , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Meios de Contraste/efeitos adversos , Angiografia Coronária/métodos , Angiografia Coronária/estatística & dados numéricos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Iohexol/efeitos adversos , Iohexol/uso terapêutico , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Ácidos Tri-Iodobenzoicos/efeitos adversos
8.
JACC Cardiovasc Imaging ; 11(11): 1625-1636, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29248657

RESUMO

OBJECTIVES: This study sought to assess the effectiveness, efficiency, and safety of a tiered, comprehensive cardiac computed tomography (CT) protocol in comparison with functional testing. BACKGROUND: Although CT angiography accurately rules out coronary artery disease (CAD), incorporation of CT myocardial perfusion imaging as part of a tiered diagnostic approach could improve the clinical value and efficiency of cardiac CT in the diagnostic work-up of patients with angina pectoris. METHODS: Between July 2013 and November 2015, 268 patients (mean age 58 years; 49% female) with stable angina (mean pre-test probability 54%) were prospectively randomized between cardiac CT and standard guideline-directed functional testing (95% exercise electrocardiography). The tiered cardiac CT protocol included a calcium scan, followed by CT angiography if calcium was detected. Patients with ≥50% stenosis on CT angiography underwent CT myocardial perfusion imaging. RESULTS: By 6 months, the primary endpoint, the rate of invasive coronary angiograms without a European Society of Cardiology class I indication for revascularization, was lower in the CT group than in the functional testing group (2 of 130 [1.5%] vs. 10 of 138 [7.2%]; p = 0.035), whereas the proportion of invasive angiograms with a revascularization indication was higher (88% vs. 50%; p = 0.017). The median duration until the final diagnosis was 0 (0 of 0) days in the CT group and 0 (0 of 17) in the functional testing group (p < 0.001). Overall, 13% of patients randomized to CT required further testing, compared with 37% in the functional testing group (p < 0.001). The adverse event rate was similar (3% vs. 3%; p = 1.000), although the median cumulative radiation dose was higher for the CT group (3.1 mSv [interquartile range: 1.6 to 7.8] vs. 0 mSv [interquartile range: 0.0 to 7.1]; p < 0.001). CONCLUSIONS: In patients with suspected stable CAD, a tiered cardiac CT protocol with dynamic perfusion imaging offers a fast and efficient alternative to functional testing. (Comprehensive Cardiac CT Versus Exercise Testing in Suspected Coronary Artery Disease 2 [CRESCENT2]; NCT02291484).


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X , Idoso , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Estenose Coronária/fisiopatologia , Estenose Coronária/terapia , Vasos Coronários/fisiopatologia , Eletrocardiografia , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica , Países Baixos , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Índice de Gravidade de Doença
9.
Eur Heart J Cardiovasc Imaging ; 18(6): 648-653, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28369281

RESUMO

AIMS: Paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) is a complication with potentially severe consequences. The relation between native aortic root calcium burden, stent frame eccentricity and PVL was not studied before. METHODS AND RESULTS: Two-hundred-and-twenty-three consecutive patients with severe aortic stenosis who underwent TAVI with a Medtronic CoreValve System© and who had available pre-discharge transthoracic echocardiography were studied. Echocardiographic stent inflow frame eccentricity was defined as major-minor diameter in a short-axis view >2 mm. PVL was scored according to the updated Valve Academic Research Consortium (VARC-2) recommendations. In a subgroup of 162 (73%) patients, the calcium Agatston score was available. Stent frame eccentricity was seen in 77 (35%) of patients. The correlation between the Agatston score and stent frame eccentricity was significant (ρ = 0.241, P = 0.003). Paravalvular leakage was absent in 91 cases (41%), mild in 67 (30%), moderate in 51 (23%), and severe in 14 (6%) cases. The correlation between stent frame eccentricity and PVL severity was significant (ρ = 0.525, P < 0.0001). There was a relation between particular eccentric stent frame shapes and the site of PVL. CONCLUSION: Calcification of the aortic annulus is associated with a subsequent eccentric shape of the CoreValve prosthesis. This eccentric shape results in more PVL, with the localization of PVL related to the shape of stent frame eccentricity.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Ecocardiografia Doppler em Cores/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/terapia , Estenose da Valva Aórtica/mortalidade , Calcinose/cirurgia , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Stents , Taxa de Sobrevida , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos
10.
Circ Cardiovasc Imaging ; 10(2)2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28174196

RESUMO

BACKGROUND: Cardiac computed tomography (CT) represents an alternative diagnostic strategy for women with suspected coronary artery disease, with potential benefits in terms of effectiveness and cost-efficiency. METHODS AND RESULTS: The CRESCENT trial (Calcium Imaging and Selective CT Angiography in Comparison to Functional Testing for Suspected Coronary Artery Disease) prospectively randomized 350 patients with stable angina (55% women; aged 55±10 years), mostly with an intermediate coronary artery disease probability, between cardiac CT and functional testing. The tiered cardiac CT protocol included a calcium scan followed by CT angiography if the Agatston calcium score was between 1 and 400. Patients with test-specific contraindications were not excluded from study participation. Sex differences were studied as a prespecified subanalysis. Enrolled women presented more frequently with atypical chest pain and had a lower pretest probability of coronary artery disease compared with men. Independently of these differences, cardiac CT led in both sexes to a fast final diagnosis when compared with functional testing, although the effect was larger in women (P interaction=0.01). The reduced need for further testing after CT, compared with functional testing, was most evident in women (P interaction=0.009). However, no sex interaction was observed with respect to changes in angina and quality of life, cumulative diagnostic costs, and applied radiation dose (all P interactions≥0.097). CONCLUSIONS: Cardiac CT is more efficient in women than in men in terms of time to reach the final diagnosis and downstream testing. However, overall clinical outcome showed no significant difference between women and men after 1 year. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01393028.


Assuntos
Angina Estável/etiologia , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Angiografia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Disparidades em Assistência à Saúde , Calcificação Vascular/diagnóstico por imagem , Idoso , Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Intervalo Livre de Doença , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Países Baixos , Valor Preditivo dos Testes , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Fatores Sexuais , Fatores de Tempo , Calcificação Vascular/complicações
11.
J Heart Valve Dis ; 25(3): 289-295, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27989038

RESUMO

BACKGROUND: The echocardiographic grading of paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) severity is challenging. The study aim was to assess the value of quantitative Doppler echocardiography to monitor PVL severity. METHODS: A total of 100 subjects was enrolled in the study, including 65 consecutive patients who had undergone TAVI with a CoreValve prosthesis and without valvular aortic regurgitation, and 35 normal controls. The PVL volume was calculated using the quantitative Doppler method as the difference of left and right ventricular stroke volume (SV). PVL severity was assessed both visually and quantitatively as the circumferential extent on a short-axis view (SAX). RESULTS: The inter-observer variabilities for SVs in TAVI patients were disappointing: 14 ± 11% for the left ventricular SV and 18 ± 14% for right ventricular SV. The correlation (r2) between the averaged regurgitant PVL volume and circumferential SAX extent of PVL was 0.02 (p = NS). The relationship between PVL volumes and categories, defined quantitatively by the circumferential SAX extent of PVL and qualitatively by visual assessment of severity of PVL were poor. The results improved when only patients with optimal quality images were included but were still statistically non-significant. CONCLUSIONS: The relationship between calculated PVL volume in TAVI patients and other estimates of PVL severity was poor, most likely due to intrinsic errors made in the quantitative Doppler method. Therefore, one should be prudent to include the quantitative Doppler method in TAVI patients in clinical trials and clinical decision-making, in particular in patients with reduced image quality.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia Doppler , Substituição da Valva Aórtica Transcateter/efeitos adversos , Adulto , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estudos de Casos e Controles , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Função Ventricular Esquerda , Função Ventricular Direita
12.
Cardiovasc Ultrasound ; 14(1): 37, 2016 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-27600600

RESUMO

To make assessment of paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) more uniform the second Valve Academic Research Consortium (VARC) recently updated the echocardiographic criteria for mild, moderate and severe PVL. In the VARC recommendation the assessment of the circumferential extent of PVL in the short-axis view is considered critical. In this paper we will discuss our observational data on the limitations and difficulties of this particular view, that may potentially result in overestimation or underestimation of PVL severity.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Humanos , Desenho de Prótese , Falha de Prótese , Fatores de Risco
14.
Int J Cardiol ; 216: 9-15, 2016 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27135150

RESUMO

BACKGROUND: The interaction of left ventricular outflow tract (LVOT) and transcatheter heart valve (THV) is complex and may be device design specific. We sought to study LVOT characteristics and its relation with permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR). METHODS: We studied 302 patients with a median age of 81years [75-84]. Computed tomography was used to assess LVOT in terms of amount of calcium, perimeter and device size relative to LVOT. RESULTS: We implanted a Medtronic CoreValve (MCS) in 203 patients, Edwards-Sapien XT (ESV-XT) in 38, Edwards-Sapien S3 (ESV-S3) in 26 and Lotus in 35 patients. Sixty-eight patients (22.5%) received a new PPI within 30days after the index procedure. The incidence of PPI was 22.7% with MCS, 10.5% with ESV-XT, 26.9% with ESV-S3 and 31.4% with Lotus. By multivariate analysis RBBB at baseline (OR 2.9 [1.2-6.9, p=0.014), second generation valves (OR 2.1 [1.0-4.5], p=0.048), DOI (OR 1.20 per 1mm increment, [1.09-1.31], p<0.001) and LVOT sizing (OR per 1% increment 1.03 [1.01-1.07], p=0.022) were associated with need for PPI. Sensitivity analyses suggest that a lesser degree of LVOT oversizing triggers PPI with second generation THVs vs. first generation THVs. CONCLUSIONS: More LVOT oversizing is associated with a higher need for permanent pacemaker implantation after TAVR, even more so with deeper THV implants and next generation devices (ESV-S3 and Lotus). Sizing algorithms should focus more on LVOT dimensions to reduce PPI.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Incidência , Masculino , Marca-Passo Artificial , Desenho de Prótese , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Resultado do Tratamento
15.
J Card Surg ; 31(7): 429-31, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27212634

RESUMO

Surgical aortic valve replacement may be complicated by severe dynamic left ventricular outflow tract obstruction and cardiogenic shock in the postoperative period. We present a patient who developed severe anterior motion following aortic valve and Cox MAZE surgery which necessitated a mitral valve replacement. doi: 10.1111/jocs.12763 (J Card Surg 2016;31:429-431).


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Idoso , Estenose da Valva Aórtica/complicações , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ecocardiografia , Humanos , Masculino , Índice de Gravidade de Doença , Choque Cardiogênico/diagnóstico por imagem
16.
Eur Heart J ; 37(15): 1232-43, 2016 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-26746631

RESUMO

AIMS: To compare the effectiveness and safety of a cardiac computed tomography (CT) algorithm with functional testing in patients with symptoms suggestive of coronary artery disease (CAD). METHODS AND RESULTS: Between April 2011 and July 2013, 350 patients with stable angina, referred to the outpatient clinic of four Dutch hospitals, were prospectively randomized between cardiac CT and functional testing (2 : 1 ratio). The tiered cardiac CT protocol included a calcium scan followed by CT angiography if the Agatston calcium score was between 1 and 400. Patients with test-specific contraindications were not excluded from study participation. By 1 year, fewer patients randomized to cardiac CT reported anginal complaints (P = 0.012). The cumulative radiation dose was slightly higher in the CT group (6.6 ± 8.7 vs. 6.1 ± 9.3 mSv; P < 0.0001). After 1.2 years, event-free survival was 96.7% for patients randomized to CT and 89.8% for patients randomized to functional testing (P = 0.011). After CT, the final diagnosis was established sooner (P < 0.0001), and additional downstream testing was required less frequently (25 vs. 53%, P < 0.0001), resulting in lower cumulative diagnostic costs (€369 vs. €440; P < 0.0001). CONCLUSION: For patients with suspected stable CAD, a tiered cardiac CT protocol offers an effective and safe alternative to functional testing. Incorporating the calcium scan into the diagnostic workup was safe and lowered diagnostic expenses and radiation exposure.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Calcificação Vascular/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Eletrocardiografia , Teste de Esforço/métodos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica/estatística & dados numéricos , Doses de Radiação , Fatores de Risco , Inquéritos e Questionários , Resultado do Tratamento , Calcificação Vascular/fisiopatologia , Calcificação Vascular/terapia
17.
EuroIntervention ; 12(4): 519-25, 2016 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-26342470

RESUMO

AIMS: Aortic regurgitation (AR) after Medtronic CoreValve System (MCS) implantation may be explained by patient-, operator- and procedure-related factors. We sought to explore if frame geometry, as a result of a specific device-host interaction, contributes to AR. METHODS AND RESULTS: Using rotational angiography with dedicated motion compensation, we assessed valve frame geometry in 84 patients who underwent TAVI with the MCS. Aortic regurgitation was assessed by angiography (n=84, Sellers) and echocardiography at discharge (n=72, VARC-2). Twenty-two patients (26%) had AR grade ≥2 using contrast angiography, and 17 (24%) by echocardiography. Balloon predilatation and sizing and depth of implantation did not differ between the two groups. Despite more frequent balloon post-dilatation in patients with AR (40.9 vs. 9.7%, p=0.001), the frame was more elliptical at its nadir relative to the patient's annulus (6±13 vs. -1±11%, p=0.046) and occurred in a larger proportion of patients (61.9 vs. 26.8%, p=0.004). Although the Agatston score and the eccentricity of the MCS frame relative to the annulus were independent determinants of AR (odds ratio: 1.635 [1.151-2.324], p=0.006, and 4.204 [1.237-14.290], p=0.021), there was a weak association between the Agatston score and the adjusted eccentricity (Spearman's rank correlation coefficient =-0.24, p=0.046). CONCLUSIONS: These findings indicate that AR can be explained by a specific device-host interaction which can only partially be explained by the calcium load of the aortic root.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
18.
Cardiovasc Ultrasound ; 13: 29, 2015 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-26113031

RESUMO

BACKGROUND: Symptoms in the elderly patients with severe aortic stenosis (AS) and co-morbidities seem to lack in specificity. Therefore, objective parameters for increased left ventricular(LV) filling pressures are needed. The aim of this study was to investigate the correlation between the septal, lateral and average E/e' ratio and the value of the N-terminal pro-hormone of brain natriuretic peptide (NT-proBNP). METHODS: Two-hundred-fifty consecutive symptomatic patients (mean age 80 ± 8 years, 52% men) with severe AS underwent transthoracic echocardiography and NT-proBNP measurement. RESULTS: In the overall population the septal E/e' (r = 0,459, r(2) = 0,21, P <0,0001), lateral E/e' (r = 0,322, r(2) = 0,10, P <0,0001), and the average E/e' (r = 0,432, r(2) = 0,18, P <0,0001) were all significantly correlated to NT-proBNP. After the exclusion of patients with confounders (more than mild aortic or mitral regurgitation, severe renal dysfunction, obesity or severe COPD) the septal E/e' (r = 0,584, r(2) = 0,34, P <0,0001), lateral E/e' (r = 0,377, r(2) = 0,14, P <0,0001), and the average E/e' (r = 0,487, r(2) = 0,24, P <0,0001) were all significantly better correlated to NT-proBNP. In obese patients no significant correlations were seen. Previous bypass surgery did not alter the correlations. CONCLUSIONS: In elderly patients with severe symptomatic AS there is a significant correlation between the E/e' ratio and NT-proBNP, in particular after exclusion of confounders. The correlation was best for the septal E/e' ratio and was preserved in patients with a history of bypass surgery.


Assuntos
Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/diagnóstico por imagem , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Volume Sistólico , Disfunção Ventricular Esquerda/sangue , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Biomarcadores/sangue , Ecocardiografia/métodos , Feminino , Avaliação Geriátrica/métodos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Disfunção Ventricular Esquerda/etiologia
19.
JACC Cardiovasc Interv ; 8(5): 718-24, 2015 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-25946445

RESUMO

OBJECTIVES: The aim of this study was to identify variables associated with tissue fragment embolization during transcatheter aortic valve replacement (TAVR). BACKGROUND: Brain magnetic resonance imaging and transcranial Doppler studies have revealed that cerebrovascular embolization occurs frequently during TAVR. Embolized material may be r thrombotic, tissue derived, or catheter (foreign material) fragments. METHODS: A total of 81 patients underwent TAVR with a dual filter-based embolic protection device (Montage Dual Filter System, Claret Medical, Inc., Santa Rosa, California) deployed in the brachiocephalic trunk and left common carotid artery. Both balloon-expandable and self-expanding transcatheter heart valves (THVs) were used. Filters were retrieved after TAVR and sent for histopathological analysis. RESULTS: Overall, debris was captured in 86% of patients. Captured material varied in size from 0.1 to 9.0 mm. Thrombotic material was found in 74% of patients and tissue-derived debris in 63%. Tissue fragments were found more often with balloon-expandable THVs (79% vs. 56%; p = 0.05). The embolized tissue originated from the native aortic valve leaflets, aortic wall, or left ventricular myocardium. On multivariable logistic regression analysis, balloon-expandable THVs (odds ratio: 7.315; 95% confidence interval: 1.398 to 38.289; p = 0.018) and cover index (odds ratio: 1.141; 95% confidence interval: 1.014 to 1.283; p = 0.028) were independent predictors of tissue embolization. CONCLUSIONS: Debris is captured with filter-based embolic protection in the vast majority of patients undergoing TAVR. Tissue-derived material is found in 63% of cases and is more frequent with the use of balloon-expandable systems and more oversizing.


Assuntos
Valva Aórtica , Cateterismo Cardíaco/efeitos adversos , Migração de Corpo Estranho/epidemiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Embolia Intracraniana/epidemiologia , Trombose/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Valvuloplastia com Balão/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Distribuição de Qui-Quadrado , Dispositivos de Proteção Embólica , Feminino , Migração de Corpo Estranho/diagnóstico , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Incidência , Embolia Intracraniana/diagnóstico , Modelos Logísticos , Imageamento por Ressonância Magnética , Masculino , Análise Multivariada , Países Baixos/epidemiologia , Razão de Chances , Desenho de Prótese , Fatores de Risco , Trombose/diagnóstico , Ultrassonografia Doppler Transcraniana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...