Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 41(4): 383-388, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29435997

RESUMO

BACKGROUND: Barriers to successful left ventricular lead placement within the coronary venous anatomy may include focal stenoses, thromboses, phrenic nerve stimulation, vessel tortuosity, small vessel caliber, nonexcitable tissue, and valve presence. A large series describing the utilization of coronary venous angioplasty (CVAP) for relief of these issues is absent in the literature. OBJECTIVE: We report our experience on all patients treated with CVAP in a single-center 13-year experience. METHODS: Forty-seven patients with CVAP (64% male, mean age 67 ± 12 years) were treated by five different implanting physicians for approved cardiac resynchronization therapy indications. The reason for CVAP was categorized by obstacle (focal occlusion, valve presence, small caliber vessel) and location. The number, type, and size of balloon used, inflation characteristics, complications, and success of lead deployment crossing the point of intervention were all tabulated. RESULTS: Seventy-seven percent of patients (36/47) had successful CVAP. The most common reason for intervention was a focal occlusion (24/47; 51%), followed by valve presence (13/47; 28%), and small vessel caliber (10/47; 21%). Focal occlusions were most successfully managed with CVAP (23/24; 96%), followed by small vessel caliber (7/10; 70%) and valve presence (6/13; 46%). The reason for failure was most commonly due to failure to relieve the obstruction (5/11; 45%), thrombosis (3/11; 27.3%), dissection (2/11; 18.2%), and inability to pass the balloon through the occlusion (1/11; 9.0%). There were no significant complications developed from CVAP utilization. CONCLUSION: In a large analysis, CVAP can be safely and successfully performed in the majority of instances required.


Assuntos
Angioplastia Coronária com Balão/métodos , Cateterismo Cardíaco/métodos , Vasos Coronários/patologia , Eletrodos Implantados , Insuficiência Cardíaca/terapia , Marca-Passo Artificial , Disfunção Ventricular Esquerda/terapia , Idoso , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
2.
J Cardiovasc Electrophysiol ; 22(9): 1034-41, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21457384

RESUMO

INTRODUCTION: Intraoperative modality for "real-time" left ventricular (LV) dyssynchrony quantification and optimal resynchronization is not established. This study determined the feasibility, safety, and efficacy of intracardiac echocardiography (ICE), coupled with vector velocity imaging (VVI), to evaluate LV dyssynchrony and to guide LV lead placement at the time of cardiac resynchronization therapy (CRT) implant. METHODS: One hundred and four consecutive heart failure patients undergoing ICE-guided (Group 1, N = 50) or conventional (Group 2, N = 54) CRT implant were included in the study. For Group 1 patients, LV dyssynchrony and resynchronization were evaluated by VVI including visual algorithms and the maximum differences in time-to-peak (MD-TTP) radial strain. Based on the findings, the final LV lead site was determined and optimal resynchronization was achieved. CRT responders were defined using standard criteria 6 months after implantation. RESULTS: Both groups underwent CRT implant with no complications. In Group 1, intraprocedural optimal resynchronization by VVI including visual algorithms and MD-TTP was a predictor discriminating CRT response with a sensitivity of 95% and specificity of 89%. Use of ICE/VVI increased number of and predicted CRT responders (82% in Group 1 vs 63% in Group 2; OR = 2.68, 95% CI 1.08-6.65, P = 0.03). CONCLUSION: ICE can be safely performed during CRT implantation. "Real-time" VVI appears to be helpful in determining the final LV lead position and pacing mode that allow better intraprocedural resynchronization. VVI-optimized acute resynchronization predicts CRT response and this approach is associated with higher number of CRT responders.


Assuntos
Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Monitorização Intraoperatória/métodos , Vetorcardiografia/instrumentação , Vetorcardiografia/métodos , Idoso , Bloqueio de Ramo/fisiopatologia , Ecocardiografia/instrumentação , Ecocardiografia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação , Estudos Prospectivos , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...