Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Eur J Echocardiogr ; 11(9): 778-85, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20488814

RESUMO

AIMS: The aim of this study, undertaken in patients who underwent mitral valve (MV) repair surgery, was to evaluate the accuracy of pre-operative three-dimensional (3D) transthoracic echocardiography (TTE) in the evaluation of MV pathology in cases with simple or complex lesions. METHODS AND RESULTS: Two hundred consecutive patients with severe mitral regurgitation due to degenerative MV prolapse underwent a complete 3DTTE the day before surgery. Three-dimensional TTE data were compared with MV surgical inspection. Three-dimensional echocardiography was feasible in a relatively short time (5 ± 3 min) with good (67%) and optimal (21%) imaging quality in the majority of cases. Three-dimensional TTE allowed an accurate identification (95% accuracy) of all MV lesions. Seventy-three (36.5%) patients had simple lesions at 3DTTE and 71 of them (97.2%) underwent a simple surgical procedure; 127 (63.5%) had complex lesions at 3DTTE and, in these cases, surgeons performed either simple procedures (48%) or complex procedures (47.2%) or valve replacement in 4.7% (after a first attempt for repair). CONCLUSION: Three-dimensional TTE is feasible, not time-consuming, and accurate in identifying cases with simple vs. complex MV lesions.


Assuntos
Ecocardiografia Tridimensional/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/fisiopatologia , Cuidados Pré-Operatórios , Sensibilidade e Especificidade , Resultado do Tratamento
3.
Am J Cardiol ; 102(4): 499-505, 2008 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-18678314

RESUMO

Right ventricular (RV) dimensions and function are of diagnostic and prognostic importance in cardiac disease. Because of the peculiar morphology of the right ventricle, 2-dimensional echocardiography has several limitations in RV evaluation. Recently, new 3-dimensional transthoracic echocardiographic software adapted for RV morphology was introduced. The aims of this study were to evaluate the feasibility of 3-dimensional RV analysis in a large population and to compare and correlate 3-dimensional RV data with classic 2-dimensional and Doppler parameters, including tricuspid annular plane systolic excursion and peak systolic velocity on Doppler tissue imaging, RV fractional shortening area, RV stroke volume (by the Doppler method), and pulmonary arterial systolic pressure. Two hundred subjects were studied: 48 normal controls and 152 patients with valvular heart disease (104 patients), idiopathic dilated cardiomyopathy (20 patients), or pulmonary hypertension (28 patients). The mean times for 3-dimensional acquisition and 3-dimensional reconstruction were 3 +/- 1 and 4 +/- 2 minutes, respectively. Imaging quality was good in most cases (85%). The mean RV diastolic and systolic volumes were 103 +/- 38 and 46 +/- 28 ml, respectively. The RV ejection fraction (RVEF) was correlated negatively with pulmonary arterial systolic pressure and positively with tricuspid annular plane systolic excursion, peak systolic velocity, and fractional shortening area. The pathologic group was characterized by larger RV volumes and lower RVEFs. Three-dimensional echocardiography clearly showed that in the pathologic group, patients with pulmonary hypertension had the largest RV volumes and the lowest RVEFs and that those with idiopathic dilated cardiomyopathy were characterized by RVEFs lower than those of patients with valvular disease. In conclusion, this new quantitative 3-dimensional method to assess RV volumes and function is feasible, relatively simple, and not time consuming. Data obtained with 3-dimensional analysis are well correlated with those obtained by 2-dimensional and Doppler methods and can differentiate normal and pathologic subjects.


Assuntos
Ecocardiografia Tridimensional , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita , Estudos de Casos e Controles , Diástole , Ecocardiografia Tridimensional/instrumentação , Ecocardiografia Tridimensional/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Volume Sistólico , Sístole
4.
J Am Soc Echocardiogr ; 20(11): 1315.e5-8, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17600679

RESUMO

We describe a rare case of intermittent dysfunction of a bileaflet mechanical aortic valve prosthesis. Subvalvular pannus overgrowth on the inflow aspect of the prosthesis impeded normal closure of one leaflet causing severe aortic regurgitation, which occurred intermittently. The complementary role of transthoracic and transesophageal echocardiography and cine-fluoroscopy in the diagnosis of this case is described.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Análise de Falha de Equipamento , Feminino , Humanos , Pessoa de Meia-Idade , Ultrassonografia
5.
Int J Cardiol ; 115(1): 86-9, 2007 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-16750277

RESUMO

The evaluation of right ventricular (RV) systolic function is important for its clinical and prognostic value but difficult to obtain due to RV complex anatomy. Aims of this study were to evaluate the feasibility of a routine use of RV fractional shortening area (FSA), systolic excursion (TAPSE) and peak systolic velocity (PSV) of tricuspidal annular motion in a large series of cases (900 pts), to determine the values in normal subjects (150) and in patients (750) with different pathologies and to correlate these indexes to clinical and echo-Doppler variables. FSA (50.3+/-10% vs 54.6+/-9% p<0.01), TAPSE (20.2+/-5 vs 24.7+/-4 mm, p<0.01) and PSV (16.2+/-4 vs 20+/-4 cm/s, p<0.01) were lower in patients than in normals, correlated positively to left ventricular ejection fraction and negatively to the pulmonary pressure. The values of 17 mm for TAPSE, 12 cm/s for PSV and 37% for FSA identified patients with high specificity. The values in subgroups of pathological patients were evaluated and compared.


Assuntos
Ecocardiografia Doppler , Valva Tricúspide/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita/fisiologia , Estudos de Viabilidade , Humanos , Reprodutibilidade dos Testes , Sístole , Disfunção Ventricular Direita/etiologia
6.
J Am Coll Cardiol ; 48(12): 2524-30, 2006 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-17174193

RESUMO

OBJECTIVES: The aim of this study, undertaken in patients who underwent mitral valve (MV) repair surgery, was to evaluate the feasibility and accuracy of 3-dimensional (3D) transthoracic (TTE) and transesophageal (TEE) echocardiography in the evaluation of MV pathology. BACKGROUND: A pre-operative assessment of MV anatomy is essential to surgical design in patients undergoing MV repair. Although 2-dimensional (2D) echocardiography provides precise information regarding MV anatomy, 3D TTE and 3D TEE could increase the understanding of MV apparatus and individual scallop identification. METHODS: One-hundred-twelve consecutive patients with severe mitral regurgitation due to MV prolapse underwent a complete 2D and 3D TTE the day before surgery and a complete 2D and 3D TEE in the operating room. Echocardiographic data obtained by the different techniques were compared with surgical inspection. RESULTS: Three-dimensional techniques were feasible in a relatively short time (3D TTE: 7 +/- 4 min; 3D TEE: 8 +/- 3 min), with good (3D TTE 55%; 3D TEE 35%) and optimal (3D TTE 21%; 3D TEE 45%) imaging quality in the majority of cases. Three-dimensional TEE allowed more accurate identification (95.6% accuracy) of all MV lesions in comparison with other techniques. Three-dimensional TTE and 2D TEE had similar accuracies (90% and 87%, respectively), whereas the accuracy of 2D TTE (77%) was significantly lower. CONCLUSIONS: Three-dimensional TTE and TEE are feasible and useful methods in identifying the location of MV prolapse. They were superior in the description of pathology in comparison with the corresponding 2D techniques and should be regarded as an important adjunct to standard 2D examinations in decisions regarding MV repair.


Assuntos
Ecocardiografia , Insuficiência da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/diagnóstico por imagem , Idoso , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/cirurgia , Estudos Prospectivos
7.
Am J Cardiol ; 98(7): 966-9, 2006 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-16996884

RESUMO

Aortic valve diseases, hypertension, and connective tissue disorders may be causes of ascending aortic aneurysms. Aortic enlargement monitoring is essential for surgical timing and for operative design. In this regard, several imaging techniques may have limitations: magnetic resonance is not widespread and is expensive, computed tomography uses radiation, and transesophageal echocardiography is a semi-invasive method. The aim of this study was to analyze the feasibility of transthoracic echocardiography in the evaluation of aortic dimensions and its accuracy in comparison with multidetector computed tomography. In 44 patients with known ascending aortic aneurysms, transthoracic echocardiographic and computed tomographic measurements were obtained and compared at different levels: the annulus, sinuses of Valsalva, sinotubular junction, ascending aorta, and aortic arch. Transthoracic echocardiographic diameters were obtained in all patients, apart from the aortic arch, which was measured in 40 cases. Transthoracic echocardiographic and computed tomographic diameters correlated significantly (p <0.001), with very small SEEs: for the annulus, r = 0.846 (SEE 0.37); for the sinuses of Valsalva, r = 0.967 (SEE 0.35); for the sinotubular junction, r = 0.965 (SEE 0.33); for the ascending aorta, r = 0.976 (SEE 0.41); and for the aortic arch, r = 0.87 (SEE 0.50). In conclusion, transthoracic echocardiography is a feasible and accurate technique for the assessment and follow-up of thoracic aortic diameters in patients with ascending aortic aneurysms.


Assuntos
Aorta/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Aortografia , Idoso , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...