Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 104(1): 125-133, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38769727

RESUMO

BACKGROUND: The Evolut self-expanding valve (SEV) systems (Medtronic), were designed to accommodate varying valve sizes and reduce paravalvular leak (PVL) while maintaining a low delivery profile. These systems have evolved between product generations, alongside valve deployment techniques changing over time. AIMS: This study aimed to examine whether these changes impacted clinical outcomes. METHODS: EPROMPT is a prospective, investigator-initiated, postmarketing registry of consecutive patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) using the Evolut PRO/PRO+ SEV system. A total of 300 patients were divided into three consecutive cohorts of 100 patients according to implantation date (January to October 2018, November 2018 to July 2020, and August 2020 to November 2021). Procedural and clinical outcomes over these time periods were compared. RESULTS: Valve Academic Research Consortium (VARC)-2 device implantation success improved over time (70.0% vs. 78.0% vs. 88.8%, p = 0.01), with a similar trend for VARC-3 device success (94.7% vs. 81.7% vs. 96.8%, p < 0.001). PVL (all degrees) frequency was likewise reduced over time (31.0% vs. 17.0% vs. 19.2%, p = 0.04). Furthermore, a trend was noticed toward shorter procedure times and shorter length of stay. However, postprocedural pacemaker implantation rates did not significantly differ (15.2% vs. 21.1% vs. 14.0%, p = 0.43). CONCLUSION: During a 3-year period, we demonstrated better TAVR outcomes with newer SEV iterations, alongside changes in implantation techniques, which might result in better procedural and clinical outcomes. However, we did not see a significant change in peri-procedural pacemaker rates for SEV.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Tempo , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Estudos Prospectivos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Fatores de Risco , Recuperação de Função Fisiológica , Vigilância de Produtos Comercializados , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Hemodinâmica
2.
JACC Cardiovasc Interv ; 14(11): 1209-1215, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-34112456

RESUMO

OBJECTIVES: The aim of this study was to investigate whether the degree of aortic angulation (AA) affects outcomes after transcatheter aortic valve replacement (TAVR) using newer-generation transcatheter heart valves (THVs). BACKGROUND: AA ≥48° has been reported to adversely influence accurate THV deployment, procedural success, fluoroscopy time, and paravalvular leak (PVL) in patients undergoing TAVR with early generation self-expanding (SE) THVs. METHODS: A retrospective observational study was conducted among 841 patients across all risk strata who underwent transfemoral TAVR using the balloon-expandable (BE) SAPIEN 3 or the SE CoreValve Evolut PRO from 2015 to 2020. The previously published cutoff of 48° was used to analyze procedural success and in-hospital outcomes according to THV type. Receiver-operating characteristic analysis was performed to investigate the impact of AA on an in-hospital composite outcome (need for >1 THV, more than mild PVL, new permanent pacemaker implantation, stroke, and death). RESULTS: AA ≥48° did not influence outcomes in patients with BE THVs. Additionally, AA ≥48° did not influence procedural success (99.1% vs. 99.1%; p = 0.980), number of THVs used (1.02 vs. 1.04; p = 0.484), rates of more than mild PVL (0.4% vs. 0%; p = 0.486), new permanent pacemaker implantation (11.8% vs. 17.1%; p = 0.178), in-hospital stroke (3.9% vs. 1.8%; p = 0.298), or in-hospital death (0.4% vs. 0.9%; p = 0.980) in patients with SE THVs. Receiver-operating characteristic analysis demonstrated similar outcomes irrespective of AA, with areas under the curve of 0.5525 for SE THVs and 0.5115 for BE THVs. CONCLUSIONS: AA no longer plays a role with new-generation BE or SE THVs in contemporary TAVR practice. AA ≥48° did not affect procedural success or in-hospital outcomes and should no longer be a consideration when determining THV selection.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fluoroscopia , Mortalidade Hospitalar , Humanos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...