Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 206
Filtrar
1.
Sci Total Environ ; 944: 173832, 2024 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-38879042

RESUMO

Rodenticides are a key component of rodent management strategies, but birds of prey are susceptible to non-target exposure. New rules on sale and use of rodenticide products were introduced across the UK in 2016 in an industry-led stewardship scheme, with the aim of reducing this risk. To determine if this intervention has achieved its aim, exposure to second generation anticoagulant rodenticides (SGARs) was measured in buzzards. Liver samples from 790 buzzards collected between 2005 and 2022 (excluding 2016 and 2017 samples) were analyzed and the percentage presence and concentrations of SGARs from pre-stewardship and post-stewardship samples were compared. There was no statistically significant decrease in the percentage of buzzards exposed to bromadiolone, difenacoum or combined SGAR residues after the introduction of stewardship. The percentage of buzzards exposed to brodifacoum increased significantly post-stewardship, from 8 % to 27 %. There were no significant decreases in the concentrations of individual SGARs post-stewardship but concentration of combined SGARs increased significantly post-stewardship. Individual buzzards were significantly more likely to be exposed to multiple SGARs post-stewardship. Rodenticide poisoning was recorded as the cause of death for 5 % of pre- and post-stewardship buzzards with detectable levels of SGARs, and 90 % of these had combined SGAR residues >0.1 mg/kg. These findings suggest that the industry-led stewardship scheme has not yet had the intended impact of reducing SGAR exposure in non-target wildlife. The study highlights a substantial increase in exposure of buzzards to brodifacoum and to multiple SGARs post-stewardship, indicating that further changes to the stewardship scheme may be necessary.


Assuntos
Anticoagulantes , Rodenticidas , Animais , Falconiformes , Exposição Ambiental , Monitoramento Ambiental , Reino Unido , 4-Hidroxicumarinas
2.
Acta Neurol Belg ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762698

RESUMO

We present a single case of a 47 year old male with a relapsing progressive neurological disease characterised by an infiltrative inflammation of the brain and leptomeninges. Investigations revealed the presence of systemic sarcoidosis which was confirmed histologically following a mediastinal lymph node biopsy. The imaging appearances of the brain and spinal canal lesions were compatible with neurological involvement by the same disease. Despite treatment, the patient deteriorated and died. We present the neuropathological findings, correlate these with the imaging features, and find that neuropathological evidence for disease was in this case strikingly more widespread than predicted by imaging ante-mortem.

3.
Phys Rev Lett ; 131(4): 041003, 2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37566859

RESUMO

We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment, which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of 5.9 ton. During the (1.09±0.03) ton yr exposure used for this search, the intrinsic ^{85}Kr and ^{222}Rn concentrations in the liquid target are reduced to unprecedentedly low levels, giving an electronic recoil background rate of (15.8±1.3) events/ton yr keV in the region of interest. A blind analysis of nuclear recoil events with energies between 3.3 and 60.5 keV finds no significant excess. This leads to a minimum upper limit on the spin-independent WIMP-nucleon cross section of 2.58×10^{-47} cm^{2} for a WIMP mass of 28 GeV/c^{2} at 90% confidence level. Limits for spin-dependent interactions are also provided. Both the limit and the sensitivity for the full range of WIMP masses analyzed here improve on previous results obtained with the XENON1T experiment for the same exposure.

4.
Eur Phys J C Part Fields ; 83(8): 717, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37576939

RESUMO

The DARWIN observatory is a proposed next-generation experiment with 40 tonnes of liquid xenon as an active target in a time projection chamber. To study challenges related to the construction and operation of a multi-tonne scale detector, we have designed and constructed a vertical, full-scale demonstrator for the DARWIN experiment at the University of Zurich. Here, we present the first results from a several-months run with 343kg of xenon and electron drift lifetime and transport measurements with a 53cm tall purity monitor immersed in the cryogenic liquid. After 88days of continuous purification, the electron lifetime reached a value of (664±23)µs. We measured the drift velocity of electrons for electric fields in the range (25-75) V/cm, and found values consistent with previous measurements. We also calculated the longitudinal diffusion constant of the electron cloud in the same field range, and compared with previous data, as well as with predictions from an empirical model.

5.
Phys Rev Lett ; 130(26): 261002, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37450817

RESUMO

Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from multiply interacting massive particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.05 expected background events from muons. Following unblinding, we observe no signal candidate events. This Letter places strong constraints on spin-independent interactions of dark matter particles with a mass between 1×10^{12} and 2×10^{17} GeV/c^{2}. In addition, we present the first exclusion limits on spin-dependent MIMP-neutron and MIMP-proton cross sections for dark matter particles with masses close to the Planck scale.

6.
Phys Rev Lett ; 129(16): 161805, 2022 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-36306777

RESUMO

We report on a blinded analysis of low-energy electronic recoil data from the first science run of the XENONnT dark matter experiment. Novel subsystems and the increased 5.9 ton liquid xenon target reduced the background in the (1, 30) keV search region to (15.8±1.3) events/(ton×year×keV), the lowest ever achieved in a dark matter detector and ∼5 times lower than in XENON1T. With an exposure of 1.16 ton-years, we observe no excess above background and set stringent new limits on solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter.

7.
Eur Phys J C Part Fields ; 82(7): 599, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35821975

RESUMO

The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and 222 Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background ( ∼ 17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected 222 Rn activity concentration in XENONnT is determined to be 4.2 ( - 0.7 + 0.5 )  µ Bq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.

8.
Eur Phys J C Part Fields ; 81(4): 337, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34720714

RESUMO

The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from material surfaces attains increasing relevance in the effort to further reduce the background of such experiments. In this work, we present the 222 Rn emanation measurements performed for the XENON1T dark matter experiment. Together with the bulk impurity screening campaign, the results enabled us to select the radio-purest construction materials, targeting a 222 Rn activity concentration of 10 µ Bq / kg in 3.2 t of xenon. The knowledge of the distribution of the 222 Rn sources allowed us to selectively eliminate problematic components in the course of the experiment. The predictions from the emanation measurements were compared to data of the 222 Rn activity concentration in XENON1T. The final 222 Rn activity concentration of ( 4.5 ± 0.1 ) µ Bq / kg in the target of XENON1T is the lowest ever achieved in a xenon dark matter experiment.

9.
Phys Rev Lett ; 126(9): 091301, 2021 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-33750173

RESUMO

We report on a search for nuclear recoil signals from solar ^{8}B neutrinos elastically scattering off xenon nuclei in XENON1T data, lowering the energy threshold from 2.6 to 1.6 keV. We develop a variety of novel techniques to limit the resulting increase in backgrounds near the threshold. No significant ^{8}B neutrinolike excess is found in an exposure of 0.6 t×y. For the first time, we use the nondetection of solar neutrinos to constrain the light yield from 1-2 keV nuclear recoils in liquid xenon, as well as nonstandard neutrino-quark interactions. Finally, we improve upon world-leading constraints on dark matter-nucleus interactions for dark matter masses between 3 and 11 GeV c^{-2} by as much as an order of magnitude.

10.
Eur Phys J C Part Fields ; 80(5): 477, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32508522

RESUMO

For the first time, a small dual-phase (liquid/gas) xenon time projection chamber was equipped with a top array of silicon photomultipliers for light and charge readout. Here we describe the instrument in detail, as well as the data processing and the event position reconstruction algorithms. We obtain a spatial resolution of ∼ 1.5 mm in the horizontal plane. To characterise the detector performance, we show calibration data with internal 83 m Kr and 37 Ar sources, and we detail the production of the latter as well as its introduction into the system. We finally compare the observed light and charge yields down to electronic recoil energies of 2.82 keV to predictions based on NEST v2.0.

11.
Phys Rev Lett ; 122(14): 141301, 2019 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-31050482

RESUMO

We report the first experimental results on spin-dependent elastic weakly interacting massive particle (WIMP) nucleon scattering from the XENON1T dark matter search experiment. The analysis uses the full ton year exposure of XENON1T to constrain the spin-dependent proton-only and neutron-only cases. No significant signal excess is observed, and a profile likelihood ratio analysis is used to set exclusion limits on the WIMP-nucleon interactions. This includes the most stringent constraint to date on the WIMP-neutron cross section, with a minimum of 6.3×10^{-42} cm^{2} at 30 GeV/c^{2} and 90% confidence level. The results are compared with those from collider searches and used to exclude new parameter space in an isoscalar theory with an axial-vector mediator.

12.
Phys Rev Lett ; 122(7): 071301, 2019 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-30848617

RESUMO

We present first results on the scalar coupling of weakly interacting massive particles (WIMPs) to pions from 1 t yr of exposure with the XENON1T experiment. This interaction is generated when the WIMP couples to a virtual pion exchanged between the nucleons in a nucleus. In contrast to most nonrelativistic operators, these pion-exchange currents can be coherently enhanced by the total number of nucleons and therefore may dominate in scenarios where spin-independent WIMP-nucleon interactions are suppressed. Moreover, for natural values of the couplings, they dominate over the spin-dependent channel due to their coherence in the nucleus. Using the signal model of this new WIMP-pion channel, no significant excess is found, leading to an upper limit cross section of 6.4×10^{-46} cm^{2} (90% confidence level) at 30 GeV/c^{2} WIMP mass.

13.
Phys Rev Lett ; 123(25): 251801, 2019 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-31922764

RESUMO

We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of (22±3) tonne day. Above ∼0.4 keV_{ee}, we observe <1 event/(tonne day keV_{ee}), which is more than 1000 times lower than in similar searches with other detectors. Despite observing a higher rate at lower energies, no DM or CEvNS detection may be claimed because we cannot model all of our backgrounds. We thus exclude new regions in the parameter spaces for DM-nucleus scattering for DM masses m_{χ} within 3-6 GeV/c^{2}, DM-electron scattering for m_{χ}>30 MeV/c^{2}, and absorption of dark photons and axionlike particles for m_{χ} within 0.186-1 keV/c^{2}.

14.
Phys Rev Lett ; 123(24): 241803, 2019 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-31922867

RESUMO

Direct dark matter detection experiments based on a liquid xenon target are leading the search for dark matter particles with masses above ∼5 GeV/c^{2}, but have limited sensitivity to lighter masses because of the small momentum transfer in dark matter-nucleus elastic scattering. However, there is an irreducible contribution from inelastic processes accompanying the elastic scattering, which leads to the excitation and ionization of the recoiling atom (the Migdal effect) or the emission of a bremsstrahlung photon. In this Letter, we report on a probe of low-mass dark matter with masses down to about 85 MeV/c^{2} by looking for electronic recoils induced by the Migdal effect and bremsstrahlung using data from the XENON1T experiment. Besides the approach of detecting both scintillation and ionization signals, we exploit an approach that uses ionization signals only, which allows for a lower detection threshold. This analysis significantly enhances the sensitivity of XENON1T to light dark matter previously beyond its reach.

15.
Phys Rev Lett ; 121(11): 111302, 2018 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-30265108

RESUMO

We report on a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of (1.30±0.01) ton, resulting in a 1.0 ton yr exposure. The energy region of interest, [1.4,10.6] keV_{ee} ([4.9,40.9] keV_{nr}), exhibits an ultralow electron recoil background rate of [82_{-3}^{+5}(syst)±3(stat)] events/(ton yr keV_{ee}). No significant excess over background is found, and a profile likelihood analysis parametrized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross section for WIMP masses above 6 GeV/c^{2}, with a minimum of 4.1×10^{-47} cm^{2} at 30 GeV/c^{2} and a 90% confidence level.

16.
Clin Neurol Neurosurg ; 169: 103-106, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29653415

RESUMO

OBJECTIVE: To present and review the vascular consequences of arteritis in neurosarcoidosis. PATIENT AND METHODS: neurosarcoidosis is typically an inflammatory disorder of the meninges surrounding the brain and spinal cord. Although inflammation of small and medium sized vessels is seen pathologically and vasculitis is occasionally described, a large intracerebral arteritis has not previously been reported. A few case reports exist, however, which describe the vascular consequences of large vessel compromise in the disorder. We review the literature and present a new case with novel MRI features which imply carotid arteritis. RESULTS: The case presented with a disorder of the carotid artery on one side leading to a series of TIAs. Inflammation of the wall of the carotid artery was seen adjacent to a granulomatous leptomeningitis. The disorder responded to immunosuppressive therapy without recurrence. CONCLUSIONS: The imaging features suggest a granulomatous infiltration of the carotid artery wall leading to arteritis followed by disorganisation of the internal elastic lamina and fibrosis. The data provide further insight into the pathogenesis of neurological impairments in neurosarcoidosis. The MRI features of carotid arteritis in neurosarcoidosis have not previously been demonstrated.


Assuntos
Amaurose Fugaz/diagnóstico por imagem , Arterite/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Doenças do Sistema Nervoso Central/diagnóstico por imagem , Ataque Isquêmico Transitório/diagnóstico por imagem , Sarcoidose/diagnóstico por imagem , Amaurose Fugaz/etiologia , Arterite/complicações , Doenças do Sistema Nervoso Central/complicações , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Pessoa de Meia-Idade , Sarcoidose/complicações
17.
Phys Rev Lett ; 119(18): 181301, 2017 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-29219593

RESUMO

We report the first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind. The blinded search used 34.2 live days of data acquired between November 2016 and January 2017. Inside the (1042±12)-kg fiducial mass and in the [5,40] keV_{nr} energy range of interest for weakly interacting massive particle (WIMP) dark matter searches, the electronic recoil background was (1.93±0.25)×10^{-4} events/(kg×day×keV_{ee}), the lowest ever achieved in such a dark matter detector. A profile likelihood analysis shows that the data are consistent with the background-only hypothesis. We derive the most stringent exclusion limits on the spin-independent WIMP-nucleon interaction cross section for WIMP masses above 10 GeV/c^{2}, with a minimum of 7.7×10^{-47} cm^{2} for 35-GeV/c^{2} WIMPs at 90% C.L.

18.
Phys Rev Lett ; 118(10): 101101, 2017 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-28339273

RESUMO

We report on a search for electronic recoil event rate modulation signatures in the XENON100 data accumulated over a period of 4 yr, from January 2010 to January 2014. A profile likelihood method, which incorporates the stability of the XENON100 detector and the known electronic recoil background model, is used to quantify the significance of periodicity in the time distribution of events. There is a weak modulation signature at a period of 431_{-14}^{+16} day in the low energy region of (2.0-5.8) keV in the single scatter event sample, with a global significance of 1.9σ; however, no other more significant modulation is observed. The significance of an annual modulation signature drops from 2.8σ, from a previous analysis of a subset of this data, to 1.8σ with all data combined. Single scatter events in the low energy region are thus used to exclude the DAMA/LIBRA annual modulation as being due to dark matter electron interactions via axial vector coupling at 5.7σ.

19.
Curr Pharm Des ; 23(4): 558-564, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27897120

RESUMO

Risk reduction and the attainment of good outcomes in contemporary cataract surgery depend in part on patient compliance with a postoperative regimen of topical eye drops. Topical drops are expensive and challenging to instill properly for patients. The consequences of noncompliance or poor compliance can be significant for the patient (in the case of a complication) and for society (in the case of development of antibiotic resistance). For all of these reasons, new approaches that reduce the need for topical therapy are beginning to emerge, including intracameral injection, sustained or slow-release drug delivery mechanisms, and the recently introduced "Dropless cataract surgery," which involves intravitreal injection of single-use, compounded combination of antibiotics and corticosteroids. This paper is a review of the rationale for reducing topical therapy in cataract surgery prophylaxis, and what is known to date about the efficacy and safety of the dropless approach.


Assuntos
Corticosteroides/uso terapêutico , Antibacterianos/uso terapêutico , Antibioticoprofilaxia , Extração de Catarata/efeitos adversos , Soluções Oftálmicas/efeitos adversos , Complicações Pós-Operatórias/tratamento farmacológico , Corticosteroides/administração & dosagem , Antibacterianos/administração & dosagem , Preparações de Ação Retardada , Sistemas de Liberação de Medicamentos , Humanos , Injeções Intravítreas , Soluções Oftálmicas/uso terapêutico , Complicações Pós-Operatórias/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...