Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Orthop Res ; 41(4): 779-786, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35822352

RESUMO

Our current understanding of knee mechanics and anterior cruciate ligament (ACL) function is predominately based on data recorded during simulations of clinical examinations or the application of nonphysiologic loads and motions. These methodologies provide little information on knee and ACL mechanics during activities of daily living (ADLs). Additionally, researchers have not directly measured knee kinetics, knee contact pressures, and ACL forces, and it is unknown how these parameters change with different activities. This study quantified the effects of activity level on vertical ground reaction forces, knee kinematics, and joint and ligament forces during in vivo motions. Five female Suffolk sheep were walked twice weekly on a treadmill during level (0°), inclined (+6°), and declined (-6°) gait for 12 weeks. Electromagnetic (EM) trackers were surgically implanted onto the left distal femur and the left proximal tibia, and in vivo motions were recorded for all activities. Following sacrifice, the in vivo motions were applied to their respective knees using a serial robot with a multi-axis load cell. In vitro simulations were repeated to measure (a) total knee forces, (b) contact pressure maps, and (c) ACL-only forces. Declining the gait surface led to increased posterior translation during the swing phase and decreased flexion at hoof-strike, decreased medial contact pressure at push-off, decreased ACL force at hoof-strike and increased ACL force at push-off. This study established a system that can be used to examine knee mechanics and ACL forces during ADLs for different knee states to define design requirements for ACL reconstruction techniques.


Assuntos
Atividades Cotidianas , Lesões do Ligamento Cruzado Anterior , Humanos , Feminino , Animais , Ovinos , Articulação do Joelho/fisiologia , Ligamento Cruzado Anterior/cirurgia , Joelho , Marcha , Tíbia/fisiologia , Fenômenos Biomecânicos , Amplitude de Movimento Articular
2.
J Athl Train ; 54(5): 472-482, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31009238

RESUMO

OBJECTIVE: To evaluate sex differences in incidence rates (IRs) of anterior cruciate ligament (ACL) injury by sport type (collision, contact, limited contact, and noncontact). DATA SOURCES: A systematic review was performed using the electronic databases PubMed (1969-January 20, 2017) and EBSCOhost (CINAHL, SPORTDiscus; 1969-January 20, 2017) and the search terms anterior cruciate ligament AND injury AND (incidence OR prevalence OR epidemiology). STUDY SELECTION: Studies were included if they provided the number of ACL injuries and the number of athlete-exposures (AEs) by sex or enough information to allow the number of ACL injuries by sex to be calculated. Studies were excluded if they were analyses of previously reported data or were not written in English. DATA EXTRACTION: Data on sport classification, number of ACL injuries by sex, person-time in AEs for each sex, year of publication, sport, sport type, and level of play were extracted for analysis. DATA SYNTHESIS: We conducted IR and IR ratio (IRR) meta-analyses, weighted for study size and calculated. Female and male athletes had similar ACL injury IRs for the following sport types: collision (2.10/10 000 versus 1.12/10 000 AEs, IRR = 1.14, P = .63), limited contact (0.71/10 000 versus 0.29/10 000 AEs, IRR = 1.21, P = .77), and noncontact (0.36/10 000 versus 0.21/10 000 AEs, IRR = 1.49, P = .22) sports. For contact sports, female athletes had a greater risk of injury than male athletes did (1.88/10 000 versus 0.87/10 000 AEs, IRR = 3.00, P < .001). Gymnastics and obstacle-course races were outliers with respect to IR, so we created a sport category of fixed-object, high-impact rotational landing (HIRL). For this sport type, female athletes had a greater risk of ACL injury than male athletes did (4.80/10 000 versus 1.75/10 000 AEs, IRR = 5.51, P < .001), and the overall IRs of ACL injury were greater than all IRs in all other sport categories. CONCLUSIONS: Fixed-object HIRL sports had the highest IRs of ACL injury for both sexes. Female athletes were at greater risk of ACL injury than male athletes in contact and fixed-object HIRL sports.


Assuntos
Lesões do Ligamento Cruzado Anterior , Traumatismos em Atletas , Adolescente , Lesões do Ligamento Cruzado Anterior/epidemiologia , Lesões do Ligamento Cruzado Anterior/prevenção & controle , Traumatismos em Atletas/epidemiologia , Traumatismos em Atletas/prevenção & controle , Feminino , Humanos , Incidência , Masculino , Medição de Risco , Fatores de Risco
3.
J Biomech ; 47(9): 2022-7, 2014 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-24326097

RESUMO

Knee soft tissue structures are frequently injured, leading to the development of osteoarthritis even with treatment. Understanding how these structures contribute to knee function during activities of daily living (ADLs) is crucial in creating more effective treatments. This study was designed to determine the role of different knee structures during a simulated ADL in both human knees and ovine stifle joints. A six degree-of-freedom robot was used to reproduce each species' in vivo gait while measuring three-dimensional joint forces and torques. Using a semi-randomized selective cutting method, we determined the primary and secondary structures contributing to the forces and torques along and about each anatomical axis. In both species, the bony interaction, ACL, and medial meniscus provided most of the force contributions during stance, whereas the ovine MCL, human bone, and ACLs of both species were the key contributors during swing. This study contributes to our overarching goal of establishing functional tissue engineering parameters for knee structures by further validating biomechanical similarities between the ovine model and the human to provide a platform for measuring biomechanics during an in vivo ADL. These parameters will be used to develop more effective treatments for knee injuries to reduce or eliminate the incidence of osteoarthritis.


Assuntos
Marcha/fisiologia , Joelho/fisiologia , Joelho de Quadrúpedes/fisiologia , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Animais , Ligamento Cruzado Anterior/fisiologia , Fenômenos Biomecânicos , Humanos , Articulação do Joelho/fisiologia , Masculino , Ligamento Colateral Médio do Joelho/fisiologia , Meniscos Tibiais/fisiologia , Modelos Animais , Ovinos
4.
J Bone Joint Surg Am ; 95(17): 1620-8, 2013 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-24005204

RESUMO

Tendon injuries often result from excessive or insufficient mechanical loading, impairing the ability of the local tendon cell population to maintain normal tendon function. The resident cell population composing tendon tissue is mechanosensitive, given that the cells are able to alter the extracellular matrix in response to modifications of the local loading environment. Natural tendon healing is insufficient, characterized by improper collagen fibril diameter formation, collagen fibril distribution, and overall fibril misalignment. Current tendon repair rehabilitation protocols focus on implementing early, well-controlled eccentric loading exercises to improve repair outcome. Tissue engineers look toward incorporating mechanical loading regimens to precondition cell populations for the creation of improved biological augmentations for tendon repair.


Assuntos
Exercício Físico/fisiologia , Traumatismos dos Tendões/fisiopatologia , Tendões/fisiologia , Suporte de Carga/fisiologia , Cicatrização/fisiologia , Humanos , Estresse Mecânico
5.
J Orthop Res ; 31(4): 638-44, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23138453

RESUMO

Investigators do not yet understand the role of intrinsic tendon cells in healing at the tendon-to-bone enthesis. Therefore, our first objective was to understand how the native cell population influences tendon autograft incorporation in the central-third patellar tendon (PT) defect site. To do this, we contrasted the histochemical and biomechanical properties of de-cellularized patellar tendon autograft (dcPTA) and patellar tendon autograft (PTA) repairs in the skeletally mature New Zealand white rabbit. Recognizing that soft tissues in many animal models require up to 26 weeks to incorporate into bone, our second objective was to investigate how recovery time affects enthesis formation and graft tissue biomechanical properties. Thus, we examined graft structure and mechanics at 6, 12, and 26 weeks post-surgery. Our results showed that maintaining the native cell population produced no histochemical or biomechanical benefit at 6, 12, or 26 weeks. These findings suggest that PTA healing is mediated more by extrinsic rather than intrinsic cellular mechanisms. Moreover, while repair tissue biomechanical properties generally increased from 6 to 12 weeks after surgery, no further improvements were noted up to 26 weeks.


Assuntos
Ligamento Patelar/citologia , Ligamento Patelar/transplante , Cicatrização , Animais , Fenômenos Biomecânicos , Rejeição de Enxerto , Ligamento Patelar/cirurgia , Coelhos , Transplante Autólogo/patologia , Cicatrização/fisiologia
6.
J Biomech Eng ; 133(9): 091002, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22010737

RESUMO

Previous studies by our laboratory have demonstrated that implanting a stiffer tissue engineered construct at surgery is positively correlated with repair tissue stiffness at 12 weeks. The objective of this study was to test this correlation by implanting a construct that matches normal tissue biomechanical properties. To do this, we utilized a soft tissue patellar tendon autograft to repair a central-third patellar tendon defect. Patellar tendon autograft repairs were contrasted against an unfilled defect repaired by natural healing (NH). We hypothesized that after 12 weeks, patellar tendon autograft repairs would have biomechanical properties superior to NH. Bilateral defects were established in the central-third patellar tendon of skeletally mature (one year old), female New Zealand White rabbits (n = 10). In one limb, the excised tissue, the patellar tendon autograft, was sutured into the defect site. In the contralateral limb, the defect was left empty (natural healing). After 12 weeks of recovery, the animals were euthanized and their limbs were dedicated to biomechanical (n = 7) or histological (n = 3) evaluations. Only stiffness was improved by treatment with patellar tendon autograft relative to natural healing (p = 0.009). Additionally, neither the patellar tendon autograft nor natural healing repairs regenerated a normal zonal insertion site between the tendon and bone. Immunohistochemical staining for collagen type II demonstrated that fibrocartilage-like tissue was regenerated at the tendon-bone interface for both repairs. However, the tissue was disorganized. Insufficient tissue integration at the tendon-to-bone junction led to repair tissue failure at the insertion site during testing. It is important to re-establish the tendon-to-bone insertion site because it provides joint stability and enables force transmission from muscle to tendon and subsequent loading of the tendon. Without loading, tendon mechanical properties deteriorate. Future studies by our laboratory will investigate potential strategies to improve patellar tendon autograft integration into bone using this model.


Assuntos
Fenômenos Mecânicos , Ligamento Patelar/patologia , Ligamento Patelar/cirurgia , Próteses e Implantes , Animais , Fenômenos Biomecânicos , Feminino , Ligamento Patelar/anormalidades , Falha de Prótese , Coelhos , Tíbia/citologia , Transplante Autólogo
7.
Instr Course Lect ; 60: 485-97, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21553793

RESUMO

Anterior cruciate ligament reconstruction is the sixth most common procedure performed by orthopaedic surgeons. The goals of the procedure are to restore knee stability and patient function. These goals are dependent on proper graft positioning and incorporation. Anterior cruciate ligament reconstruction involves a technically complicated series of steps, all of which affect graft healing and clinical outcome. A wide variety of graft choices and surgical techniques are currently available for use. It is important for orthopaedic surgeons performing anterior cruciate ligament reconstructions to be aware of the indications for graft selection, techniques for correct graft placement, and the biologic implications related to these factors.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Competência Clínica , Enxerto Osso-Tendão Patelar-Osso , Contraindicações , Fêmur/cirurgia , Humanos , Cuidados Pós-Operatórios , Tíbia/cirurgia , Coleta de Tecidos e Órgãos , Torniquetes , Transplante Homólogo , Resultado do Tratamento , Cicatrização
8.
J Biomech Eng ; 133(2): 021010, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21280882

RESUMO

Activities of daily living (ADLs) generate complex, multidirectional forces in the anterior cruciate ligament (ACL). While calibration problems preclude direct measurement in patients, ACL forces can conceivably be measured in animals after technical challenges are overcome. For example, motion and force sensors can be implanted in the animal but investigators must determine the extent to which these sensors and surgery affect normal gait. Our objectives in this study were to determine (1) if surgically implanting knee motion sensors and an ACL force sensor significantly alter normal ovine gait and (2) how increasing gait speed and grade on a treadmill affect ovine gait before and after surgery. Ten skeletally mature, female sheep were used to test four hypotheses: (1) surgical implantation of sensors would significantly decrease average and peak vertical ground reaction forces (VGRFs) in the operated limb, (2) surgical implantation would significantly decrease single limb stance duration for the operated limb, (3) increasing treadmill speed would increase VGRFs pre- and post operatively, and (4) increasing treadmill grade would increase the hind limb VGRFs pre- and post operatively. An instrumented treadmill with two force plates was used to record fore and hind limb VGRFs during four combinations of two speeds (1.0 m/s and 1.3 m/s) and two grades (0 deg and 6 deg). Sensor implantation decreased average and peak VGRFs less than 10% and 20%, respectively, across all combinations of speed and grade. Sensor implantation significantly decreased the single limb stance duration in the operated hind limb during inclined walking at 1.3 m/s but had no effect on single limb stance duration in the operated limb during other activities. Increasing treadmill speed increased hind limb peak (but not average) VGRFs before surgery and peak VGRF only in the unoperated hind limb during level walking after surgery. Increasing treadmill grade (at 1 m/s) significantly increased hind limb average and peak VGRFs before surgery but increasing treadmill grade post op did not significantly affect any response measure. Since VGRF values exceeded 80% of presurgery levels, we conclude that animal gait post op is near normal. Thus, we can assume normal gait when conducting experiments following sensor implantation. Ultimately, we seek to measure ACL forces for ADLs to provide design criteria and evaluation benchmarks for traditional and tissue engineered ACL repairs and reconstructions.


Assuntos
Fenômenos Mecânicos , Modelos Animais , Movimento , Próteses e Implantes , Ovinos/fisiologia , Ovinos/cirurgia , Animais , Ligamento Cruzado Anterior/fisiologia , Fenômenos Biomecânicos , Feminino , Membro Anterior/fisiologia , Membro Anterior/cirurgia , Membro Posterior/fisiologia , Membro Posterior/cirurgia , Condicionamento Físico Animal
9.
Sports Health ; 3(2): 175-8, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23016005

RESUMO

Partial triceps tendon disruptions are a rare injury that can lead to debilitating outcomes if misdiagnosed or managed inappropriately. The clinician should have a high index of suspicion when the mechanism involves a fall onto an outstretched arm and there is resultant elbow extension weakness along with pain and swelling. The most common location of rupture is at the tendon-osseous junction. This case report illustrates a partial triceps tendon disruption with involvement of, primarily, the medial head and the superficial expansion. Physical examination displayed weakness with resisted elbow extension in a flexed position over 90°. Radiographs revealed a tiny fleck of bone proximal to the olecranon, but this drastically underestimated the extent of injury upon surgical exploration. Magnetic resonance imaging is essential to ascertain the percentage involvement of the tendon; it can be used for patient education and subsequently to determine treatment recommendations. Although excellent at finding associated pathology, it may misjudge the size of the tear. As such, physicians must consider associated comorbidities and patient characteristics when formulating treatment plans.

10.
Nat Protoc ; 5(5): 849-63, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20431531

RESUMO

Tendon and ligament injuries are significant contributors to musculoskeletal injuries. Unfortunately, traditional methods of repair are not uniformly successful and can require revision surgery. Our research is focused on identifying appropriate animal injury models and using tissue-engineered constructs (TECs) from bone-marrow-derived mesenchymal stem cells and collagen scaffolds. Critical to this effort has been the development of functional tissue engineering (FTE). We first determine the in vivo mechanical environment acting on the tissue and then precondition the TECs in culture with aspects of these mechanical signals to improve repair outcome significantly. We describe here a detailed protocol for conducting several complete iterations around our FTE 'road map.' The in vitro portion, from bone marrow harvest to TEC collection, takes 54 d. The in vivo portion, from TEC implantation to limb harvest, takes 84 d. One complete loop around the tissue engineering road map, as presented here, takes 138 d to complete.


Assuntos
Colágeno/fisiologia , Transplante de Células-Tronco Mesenquimais/métodos , Células-Tronco Mesenquimais/fisiologia , Traumatismos dos Tendões/terapia , Engenharia Tecidual/métodos , Animais , Materiais Biocompatíveis , Fenômenos Biomecânicos , Bioprótese , Feminino , Implantes Experimentais , Células-Tronco Mesenquimais/citologia , Coelhos , Alicerces Teciduais
11.
Tissue Eng Part A ; 15(8): 2103-2111, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19191501

RESUMO

Our group has previously reported that in vitro mechanical stimulation of tissue-engineered tendon constructs significantly increases both construct stiffness and the biomechanical properties of the repair tissue after surgery. When optimized using response surface methodology, our results indicate that a mechanical stimulus with three components (2.4% strain, 3000 cycles/day, and one cycle repetition) produced the highest in vitro linear stiffness. Such positive correlations between construct and repair stiffness after surgery suggest that enhancing structural stiffness before surgery could not only accelerate repair stiffness but also prevent premature failures in culture due to poor mechanical integrity. In this study, we examined the combined effects of scaffold crosslinking and subsequent mechanical stimulation on construct mechanics and biology. Autologous tissue-engineered constructs were created by seeding mesenchymal stem cells (MSCs) from 15 New Zealand white rabbits on type I collagen sponges that had undergone additional dehydrothermal crosslinking (termed ADHT in this manuscript). Both constructs from each rabbit were mechanically stimulated for 8h/day for 12 consecutive days with half receiving 100 cycles/day and the other half receiving 3000 cycles/day. These paired MSC-collagen autologous constructs were then implanted in bilateral full-thickness, full-length defects in the central third of rabbit patellar tendons. Increasing the number of in vitro cycles/day delivered to the ADHT constructs in culture produced no differences in stiffness or gene expression and no changes in biomechanical properties or histology 12 weeks after surgery. Compared to MSC-based repairs from a previous study that received no additional treatment in culture, ADHT crosslinking of the scaffolds actually lowered the 12-week repair stiffness. Thus, while ADHT crosslinking may initially stiffen a construct in culture, this specific treatment also appears to mask any benefits of stimulation among repairs postsurgery. Our findings emphasize the importance of properly preconditioning a scaffold to better control/modulate MSC differentiation in vitro and to further enhance repair outcome in vivo.


Assuntos
Regulação da Expressão Gênica , Tendões/patologia , Alicerces Teciduais , Cicatrização , Animais , Fenômenos Biomecânicos , Imuno-Histoquímica , Coelhos , Engenharia Tecidual
12.
J Orthop Res ; 26(1): 1-9, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17676628

RESUMO

Over the past 8 years, our group has been continuously improving tendon repair using a functional tissue engineering (FTE) paradigm. This paradigm was motivated by inconsistent clinical results after tendon repair and reconstruction, and the modest biomechanical improvements we observed after repair of rabbit central patellar tendon defects using mesenchymal stem cell-gel-suture constructs. Although possessing a significantly higher stiffness and failure force than for natural healing, these first generation constructs were quite weak compared to normal tendon. Fundamental to the new FTE paradigm was the need to determine in vivo forces to which the repair tissue might be exposed. We first recorded these force patterns in two normal tendon models and then compared these peak forces to those for repairs of central defects in the rabbit patellar tendon model (PT). Replacing the suture with end-posts in culture and lowering the mesenchymal stem cell (MSC) concentration of these constructs resulted in failure forces greater than peak in vivo forces that were measured for all the studied activities. Augmenting the gel with a type I collagen sponge further increased repair stiffness and maximum force, and resulted in the repair tangent stiffness matching normal stiffness up to peak in vivo forces. Mechanically stimulating these constructs in bioreactors further enhanced repair biomechanics compared to normal. We are now optimizing components of the mechanical signal that is delivered in culture to further improve construct and repair outcome. Our contributions in the area of tendon functional tissue engineering have the potential to create functional load-bearing repairs that will revolutionize surgical reconstruction after tendon and ligament injury.


Assuntos
Transplante de Células-Tronco Mesenquimais , Traumatismos dos Tendões/cirurgia , Traumatismos dos Tendões/terapia , Engenharia Tecidual/métodos , Alicerces Teciduais , Animais , Distinções e Prêmios , Fenômenos Biomecânicos , Reatores Biológicos , Terapia Combinada , Estimulação Física/métodos , Estresse Mecânico , Traumatismos dos Tendões/fisiopatologia
13.
J Biomech Eng ; 129(6): 848-54, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18067388

RESUMO

The objective of this study was to determine how in vitro mechanical stimulation of tissue engineered constructs affects their stiffness and modulus in culture and tendon repair biomechanics 12 weeks after surgical implantation. Using six female adult New Zealand White rabbits, autogenous tissue engineered constructs were created by seeding mesenchymal stem cells (0.1 x 10(6) cells/ml) in collagen gel (2.6 mg/ml) and combining both with a collagen sponge. Employing a novel experimental design strategy, four constructs from each animal were mechanically stimulated (one 1 Hz cycle every 5 min to 2.4% peak strain for 8 h/day for 2 weeks) while the other four remained unstretched during the 2 week culture period. At the end of incubation, three of the mechanically stimulated (S) and three of the nonstimulated (NS) constructs from each animal were assigned for in vitro mechanical testing while the other two autogenous constructs were implanted into bilateral full-thickness, full-length defects created in the central third of rabbit patellar tendons (PTs). No significant differences were found in the in vitro linear stiffnesses between the S (0.15+/-0.1 N/mm) and NS constructs (0.08+/-0.02 N/mm; mean+/-SD). However, in vitro mechanical stimulation significantly increased the structural and material properties of the repair tissue, including a 14% increase in maximum force (p=0.01), a 50% increase in linear stiffness (p=0.001), and 23-41% increases in maximum stress and modulus (p=0.01). The S repairs achieved 65%, 80%, 60%, and 40% of normal central PT maximum force, linear stiffness, maximum stress, and linear modulus, respectively. The results for the S constructs exceed values obtained previously by our group using the same animal and defect model, and to our knowledge, this is the first study to show the benefits of in vitro mechanical stimulation on tendon repair biomechanics. In addition, the linear stiffnesses for the construct and repair were positively correlated (r=0.56) as were their linear moduli (r=0.68). Such in vitro predictors of in vivo outcome hold the potential to speed the development of tissue engineered products by reducing the time and costs of in vivo studies.


Assuntos
Bioprótese , Traumatismos dos Tendões/reabilitação , Resistência à Tração , Engenharia Tecidual/métodos , Cicatrização , Animais , Materiais Biocompatíveis/metabolismo , Materiais Biocompatíveis/uso terapêutico , Técnicas de Cultura de Células , Modelos Animais de Doenças , Elasticidade , Feminino , Implantes Experimentais , Teste de Materiais , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais , Ligamento Patelar/lesões , Ligamento Patelar/cirurgia , Coelhos , Traumatismos dos Tendões/cirurgia , Alicerces Teciduais
14.
Tissue Eng ; 12(8): 2291-300, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16968169

RESUMO

The objective of this study was to determine how mechanical stimulation affects the biomechanics and histology of stem cell-collagen sponge constructs used to repair central rabbit patellar tendon defects. Autogenous tissue-engineered constructs were created for both in vitro and in vivo analyses by seeding mesenchymal stem cells from 10 adult rabbits at 0.14x10(6) cells/construct in type I collagen sponges. Half of these constructs were mechanically stimulated once every 5 min for 8 h/day to a peak strain of 4% for 2 weeks. The other half remained in an incubator without mechanical stimulation for 2 weeks. Samples allocated for in vitro testing revealed that mechanically stimulated constructs had 2.5 times the linear stiffness of nonstimulated constructs. The remaining paired constructs for in vivo studies were implanted in bilateral full-thickness, full-length defects in the central third of rabbit patellar tendons. Twelve weeks after surgery, repair tissues were assigned for biomechanical (7 pairs) and histologic (3 pairs) analyses. Maximum force, linear stiffness, maximum stress, and linear modulus for the stimulated (vs. nonstimulated) repairs averaged 70% (vs. 55%), 85% (vs. 55%), 70% (vs. 50%), and 50% (vs. 40%) of corresponding values for the normal central third of the patellar tendons. The average force-elongation curve for the mechanically stimulated repairs also matched the corresponding curve for the normal patellar tendons, up to 150% of the peak in vivo force values recorded in a previous study. Construct and repair linear stiffness and linear modulus were also positively correlated (r = 0.6 and 0.7, respectively). Histologically both repairs showed excellent cellular alignment and mild staining for decorin and collagen type V, and moderate staining for fibronectin and collagen type III. This study shows that mechanical stimulation of stem cell-collagen sponge constructs can significantly improve tendon repair biomechanics up to and well beyond the functional limits of in vivo loading.


Assuntos
Materiais Biocompatíveis , Colágeno , Transplante de Células-Tronco , Células-Tronco/citologia , Traumatismos dos Tendões/cirurgia , Animais , Fenômenos Biomecânicos , Feminino , Coelhos , Engenharia Tecidual
15.
Tissue Eng ; 12(4): 681-9, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16674283

RESUMO

The objective of the present study was to test the hypotheses that implantation of cell-seeded constructs in a rabbit Achilles tendon defect model would 1) improve repair biomechanics and matrix organization and 2) result in higher failure forces than measured in vivo forces in normal rabbit Achilles tendon (AT) during an inclined hopping activity. Autogenous tissue-engineered constructs were fabricated in culture between posts in the wells of silicone dishes at four cell-to-collagen ratios by seeding mesenchymal stem cells (MSC) from 18 adult rabbits at each of two seeding densities (0.1 x 10(6) and 1 x 10(6) cell/mL) in each of two collagen concentrations (1.3 and 2.6 mg/mL). After 5 days of contraction, constructs having the two highest ratios (0.4 and 0.8 M/mg) were damaged by excessive cell traction forces and could not be used in subsequent in vivo studies. Constructs at the lower ratios (0.04 and 0.08 M/mg) were implanted in bilateral, 2 cm long gap defects in the rabbit's lateral Achilles tendon. At 12 weeks after surgery, both repair tissues were isolated and either failed in tension (n = 13) to determine their biomechanical properties or submitted for histological analysis (n = 5). No significant differences were observed in any structural or mechanical properties or in histological appearance between the two repair conditions. However, the average maximum force and maximum stress of these repairs achieved 50 and 85% of corresponding values for the normal AT and exceeded the largest peak in vivo forces (19% of failure) previously recorded in the rabbit AT. Average stiffness and modulus were 60 and 85% of normal values, respectively. New constructs with lower cell densities and higher scaffold stiffness that do not excessively contract and tear in culture and that further improve the repair stiffness needed to withstand various levels of expected in vivo loading are currently being investigated.


Assuntos
Tendão do Calcâneo/crescimento & desenvolvimento , Colágeno/química , Transplante de Células-Tronco Mesenquimais/métodos , Recuperação de Função Fisiológica/fisiologia , Traumatismos dos Tendões/fisiopatologia , Engenharia Tecidual/métodos , Tendão do Calcâneo/patologia , Tendão do Calcâneo/cirurgia , Animais , Fenômenos Biomecânicos/métodos , Contagem de Células , Feminino , Implantes Experimentais , Modelos Anatômicos , Coelhos , Traumatismos dos Tendões/etiologia , Traumatismos dos Tendões/patologia , Traumatismos dos Tendões/cirurgia , Resultado do Tratamento
16.
Tissue Eng ; 12(2): 369-79, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16548695

RESUMO

The objective of this study was to introduce mesenchymal stem cells (MSCs) into a gel-sponge composite and examine the effect the cells have on repair biomechanics and histology 12 weeks postsurgery. We tested two related hypotheses-adding MSCs would significantly improve repair biomechanics and cellular organization, and would result in higher failure forces than peak in vivo patellar tendon (PT) forces recorded for an inclined hopping activity. Autogenous tissue-engineered constructs were created by seeding MSCs from 15 adult rabbits at 0.1 x 10(6) cells/mL in 2.6 mg/mL of collagen gel in collagen sponges. Acellular constructs were created using the same concentration of collagen gel in matching collagen sponges. These cellular and acellular constructs were implanted in bilateral full-thickness, full-length defects in the central third of patellar tendons. At 12 weeks after surgery, repair tissues were assigned for biomechanical (n = 12 pairs) and histological (n = 3 pairs) analyses. Maximum force and maximum stress for the cellular repairs were about 60 and 50% of corresponding values for the normal central third of the PT, respectively. Likewise, linear stiffness and linear modulus for these cellular repairs averaged 75 and 30% of normal PT values, respectively. By contrast, the acellular repairs exhibited lower percentages of normal PT values for maximum force (40%), maximum stress (25%), linear stiffness (30%), and linear modulus (20%). Histologically, both repairs showed strong staining for collagen types III and V, fibronectin, and decorin. The cellular repairs also showed cellular alignment comparable to that of normal tendon. This study shows that introducing autogenous mesenchymal stem cells into a gel-collagen sponge composite significantly improves tendon repair compared to the use of a gel-sponge composite alone in the range of in vivo loading.


Assuntos
Colágeno/química , Transplante de Células-Tronco Mesenquimais , Patela/lesões , Recuperação de Função Fisiológica/fisiologia , Traumatismos dos Tendões/fisiopatologia , Traumatismos dos Tendões/cirurgia , Animais , Fenômenos Biomecânicos , Colágeno Tipo I/química , Colágeno Tipo III/química , Feminino , Géis , Ílio/citologia , Imuno-Histoquímica , Implantes Experimentais , Células-Tronco Mesenquimais/citologia , Coelhos , Traumatismos dos Tendões/patologia , Tendões/crescimento & desenvolvimento , Tendões/patologia , Tendões/cirurgia , Fatores de Tempo , Engenharia Tecidual/métodos , Resultado do Tratamento
17.
Tissue Eng ; 11(3-4): 448-57, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15869423

RESUMO

Autogenous tissue-engineered constructs were fabricated at four cell-to-collagen ratios (0.08, 0.04, 0.8, and 0.4 M/mg) by seeding mesenchymal stem cells (MSCs) from 16 adult rabbits at one of two seeding densities (0.1 x 10(6) and 1 x 10(6) cells/mL) in one of two collagen concentrations (1.3 and 2.6 mg/mL). The highest two ratios (0.4 and 0.8 M/mg) were damaged by excessive cell contraction and could not be used in subsequent in vivo studies. The remaining two sets of constructs were implanted into bilateral full-thickness, full-length defects created in the central third of the patellar tendon (PT). At 12 weeks after surgery, repair tissues were assigned for biomechanical (n = 13) and histological (n = 3) analyses. A second group of rabbits (n = 6) received bilateral acellular implants with the same two collagen concentrations. At 12 weeks, repair tissues were also assigned for biomechanical (n = 4) and histological (n = 2) analyses. No significant differences were observed in any structural or material properties or in histological appearance among the two cell-seeded and two acellular repair groups. Average maximum force and maximum stress of the repairs were approximately 30% of corresponding values for the central one-third of normal PT and higher than peak in vivo forces measured in rabbit PT from one of our previous publications. However, average repair stiffness and modulus were only 30 and 20% of normal PT values, respectively. Current repairs achieved higher maximum forces than in previous studies and without ectopic bone, but will need to achieve sufficient stiffness as well to be effective in the in vivo range of loading.


Assuntos
Técnicas de Cultura de Células/métodos , Colágeno/química , Transplante de Células-Tronco Mesenquimais/métodos , Recuperação de Função Fisiológica/fisiologia , Traumatismos dos Tendões/fisiopatologia , Traumatismos dos Tendões/cirurgia , Engenharia Tecidual/métodos , Animais , Fenômenos Biomecânicos/métodos , Bioprótese , Células Cultivadas , Elasticidade , Feminino , Implantes Experimentais , Coelhos , Estresse Mecânico , Traumatismos dos Tendões/patologia , Tendões/crescimento & desenvolvimento , Tendões/patologia , Tendões/cirurgia , Resistência à Tração , Resultado do Tratamento
18.
J Biomech ; 37(11): 1647-53, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15388306

RESUMO

The objective of this study was to test the hypothesis that increasing the speed and inclination of the treadmill increases the peak Achilles tendon forces and their rates of rise and fall in force. Implantable force transducers (IFT) were inserted in the confluence of the medial and lateral heads of the left gastrocnemius tendon in 11 rabbits. IFT voltages were successfully recorded in 8 animals as the animals hopped on a treadmill at each of two speeds (0.1 and 0.3 mph) and inclinations (0 degrees and 12 degrees). Instrumented tendons were isolated shortly after sacrifice and calibrated. Contralateral unoperated tendons were failed in uniaxial tension to determine maximum or failure force, from which safety factor (ratio of maximum force to peak in vivo force) was calculated for each activity. Peak force and the rates of rise and fall in force significantly increased with increasing treadmill inclination (p<0.001). Safety factors averaged 30.8+/-7.5 for quiet standing, 7.0+/-2.9 for level hopping, and 5.2+/-0.7 for inclined hopping (mean+/-SEM). These in vivo force parameters will help tissue engineers better design functional tissue engineered constructs for rabbit Achilles tendon and other tendon repairs. Force patterns can also serve as input data for mechanical stimulation of tissue-engineered constructs in culture. Such approaches are expected to help accelerate tendon repair after injury.


Assuntos
Tendão do Calcâneo/fisiologia , Locomoção , Animais , Fenômenos Biomecânicos , Feminino , Condicionamento Físico Animal , Coelhos , Engenharia Tecidual
19.
J Biomech ; 36(4): 483-8, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12600338

RESUMO

Previous studies in tissue engineering have shown that suspending undifferentiated mesenchymal stem cells in collagen gels and wrapping them about a suture causes alignment of cells and contraction of constructs in culture in a form that is suitable for implantation for tendon repair. Little is known about the patterns of these in vivo signals that might improve tendon repair biomechanics. Three hypotheses were tested in this study using the rabbit patellar tendon (PT) model: (1) peak in vivo forces and the rates of rise and fall in these forces will increase significantly with increasing levels of activity; (2) the PTs safety factor for all activities will be in the range of values found for tendons (2.5-3); (3) rabbits will not "favor" the operated limb at the time of evaluation but maintain similar vertical ground reaction forces in both limbs during quiet standing (QS). In vivo rabbit PT forces were measured during QS and while the animal hopped on a treadmill whose speed (0.04 and 0.13 m/s) and inclination (0 degrees and 12 degrees) were controlled. Implantable force transducers were surgically placed in one PT and data collected three days post surgery in each of eight New Zealand White rabbits. Peak tensile forces increased significantly with inclination of the treadmill and the rates of rise and fall in tendon force increased significantly with both speed and inclination (p<0.001). Such design criteria should be useful in mechanically stimulating cell-gel constructs for tendon repair.


Assuntos
Locomoção/fisiologia , Desenho de Prótese/métodos , Tendões/fisiologia , Engenharia Tecidual/métodos , Animais , Feminino , Traumatismos do Joelho/cirurgia , Patela/fisiologia , Esforço Físico/fisiologia , Próteses e Implantes , Desenho de Prótese/normas , Coelhos , Estresse Mecânico , Traumatismos dos Tendões/cirurgia , Tendões/cirurgia , Resistência à Tração , Engenharia Tecidual/normas , Transdutores
20.
J Orthop Sports Phys Ther ; 32(11): 568-75, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12449256

RESUMO

STUDY DESIGN: Observational case control design. OBJECTIVES: To examine muscle response to sudden trunk loading in athletes with and without a recent history of acute low back injury (LBI). BACKGROUND: Impaired neuromuscular function is associated with chronic low back pain. This study examined whether such impairment persists after recovery from an acute LBI. METHODS AND MEASURES: Seventeen athletes who had a recent history of acute LBI and 17 matched healthy controls were tested. At the time of testing (mean = 56 days postinjury, range = 7-120 days postinjury), all athletes were symptom free and had returned to regular competition. Subjects performed isometric exertions in trunk flexion, extension, and left and right lateral bending against a trunk restraining cable. Upon reaching the target isometric force, the cable was released to impose sudden loading on the lumbar spine. Surface EMG signals from 12 major trunk muscles were recorded. The shut-off and switch-on latencies and number of muscles responding to sudden loading were compared between the 2 groups. RESULTS: In all 4 testing directions, the athletes with a recent history of acute LBI shut off significantly fewer muscles and did so with delayed latency. On average, the injured subjects shut off 4.0 out of 6.0 (SD = 1.3) muscles compared to 4.6 out of 6.0 (SD = 1.3) muscles in the control group. The average muscle shut-off latency was 71 (SD = 31) milliseconds for the injured and 50 (SD = 21) milliseconds for the control subjects. No differences were found in number or latency of muscles switching on. CONCLUSIONS: These objective measures of neuromuscular function indicated an altered muscle response pattern to sudden trunk loading in athletes following their clinical recovery from a recent acute LBI.


Assuntos
Lesões nas Costas/fisiopatologia , Dor Lombar/fisiopatologia , Vértebras Lombares/fisiopatologia , Músculo Esquelético/fisiopatologia , Doença Aguda , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Dor Lombar/etiologia , Masculino , Movimento , Contração Muscular , Tempo de Reação , Valores de Referência , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...