Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Card Anaesth ; 24(3): 362-364, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34269269

RESUMO

The diagnosis of paradoxical emboli remains elusive in many cases. The causal association between the thrombotic source, the intracardiac shunt, and the final emboli location is seldom demonstrated. We present the case of a 42-year-old woman admitted to the hospital with a third stroke. The presence of a thrombus in transit through a patent foramen ovale (PFO), a deep vein thrombosis (DVT), bilateral pulmonary emboli, and an acute cerebral infarct were concurrently documented.


Assuntos
Forame Oval Patente , Embolia Pulmonar , Acidente Vascular Cerebral , Trombose , Trombose Venosa , Adulto , Feminino , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , Humanos , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Trombose Venosa/complicações , Trombose Venosa/diagnóstico por imagem
2.
Curr Treat Options Cardiovasc Med ; 6(5): 385-395, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15324614

RESUMO

The vast majority of pacemakers implanted in the United States for the treatment of symptomatic bradycardia are dual-chamber systems with a complex array of functions, such as rate responsiveness, dynamic atrioventricular delay, and automatic mode switching. Basic hemodynamic studies have convincingly demonstrated the superiority of maintaining atrioventricular synchrony. However, clinical trials have failed to demonstrate the impressive results expected based on physiologic data. The most recent randomized clinical trials have demonstrated that dual-chamber devices, when compared with single-chamber ventricular pacing, do not prevent mortality or stroke, and lead to an unexpectedly small reduction in heart failure hospitalizations. Although improvements in quality of life have not been consistently found when comparing ventricular-based versus atrial-based pacing, a reduction in the incidence of newly diagnosed atrial fibrillation in dual chamber-paced patients has been reported by most trials. Dual-chamber pacing has been reported to reduce pacemaker syndrome in US trials. The addition of rate modulation, in spite of attempting to replicate the normal response to exercise, has not shown a consistently positive impact on quality of life or treadmill time. The use of pacemakers for the treatment of vasovagal syncope is controversial. Adding dual-chamber sensing ability to current implanted defibrillators considerably reduces the number of inappropriate shocks but may increase mortality if not programmed to minimize ventricular stimulation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...