Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
MAGMA ; 36(2): 309-315, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36752933

RESUMO

PURPOSE: In this study, we aimed to measure the apparent diffusion coefficients (ADCs) of major phosphorous metabolites in the human calf muscle at 7 T with a diffusion-weighted (DW)-STEAM sequence. METHODS: A DW-STEAM sequence with bipolar gradients was implemented at 7 T, and DW MR spectra were acquired in three orthogonal directions in the human calf muscle of six healthy volunteers (TE/TM/TR = 15 ms/750 ms/5 s) at three b-values (0, 800, and 1200 s/mm2). Frequency and phase alignments were applied prior to spectral averaging. Averaged DW MR spectra were analyzed with LCModel, and ADCs of 31P metabolites were estimated. RESULTS: Four metabolites (phosphocreatine (PCr), adenosine triphosphate (ATP), inorganic phosphate (Pi) and glycerol phosphorylcholine (GPC)) were quantified at all b-values with mean CRLBs below 10%. The ADC values of PCr, ATP, Pi, and GPC were (0.24 ± 0.02, 0.15 ± 0.04, 0.43 ± 0.14, 0.40 ± 0.09) × 10-3 mm2/s, respectively. CONCLUSION: The ADCs of four 31P metabolites were successfully measured in the human calf muscle at 7 T, among which those of ATP, Pi and GPC were reported for the first time in humans. This study paves the way to investigate 31P metabolite diffusion properties in health and disease on the clinical MR scanner.


Assuntos
Imagem de Difusão por Ressonância Magnética , Músculo Esquelético , Humanos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/metabolismo , Fósforo , Trifosfato de Adenosina/metabolismo , Fosfatos
2.
MAGMA ; 36(5): 823-836, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36847989

RESUMO

OBJECTIVE: The Fluid And White matter Suppression (FLAWS) MRI sequence provides multiple T1-weighted contrasts of the brain in a single acquisition. However, the FLAWS acquisition time is approximately 8 min with a standard GRAPPA 3 acceleration factor at 3 T. This study aims at reducing the FLAWS acquisition time by providing a new sequence optimization based on a Cartesian phyllotaxis k-space undersampling and a compressed sensing (CS) reconstruction. This study also aims at showing that T1 mapping can be performed with FLAWS at 3 T. MATERIALS AND METHODS: The CS FLAWS parameters were determined using a method based on a profit function maximization under constraints. The FLAWS optimization and T1 mapping were assessed with in-silico, in-vitro and in-vivo (10 healthy volunteers) experiments conducted at 3 T. RESULTS: In-silico, in-vitro and in-vivo experiments showed that the proposed CS FLAWS optimization allows the acquisition time of a 1 mm-isotropic full-brain scan to be reduced from [Formula: see text] to [Formula: see text] without decreasing image quality. In addition, these experiments demonstrate that T1 mapping can be performed with FLAWS at 3 T. DISCUSSION: The results obtained in this study suggest that the recent advances in FLAWS imaging allow to perform multiple T1-weighted contrast imaging and T1 mapping in a single [Formula: see text] sequence acquisition.


Assuntos
Substância Branca , Humanos , Substância Branca/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Neuroimagem , Cabeça , Processamento de Imagem Assistida por Computador
3.
Magn Reson Imaging ; 99: 73-80, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36669596

RESUMO

BACKGROUND AND PURPOSE: The DKI-IVIM model that incorporates DKI (diffusional kurtosis imaging) into the IVIM (Intravoxel Incoherent Motion) concept was investigated to assess its utility for both enhanced diffusion characterization and perfusion measurements in ischemic stroke at 3 T. METHODS: Fifteen stroke patients (71 ± 11 years old) were enrolled and DKI-IVIM analysis was performed using 9 b-values from 0 to 1500 s/mm2 chosen with the Cramer-Rao-Lower-Bound optimization approach. Pseudo-diffusion coefficient D*, perfusion fraction f, blood flow-related parameter fD*, the diffusion coefficient D and an additional parameter, the kurtosis, K were determined in the ischemic lesion and controlateral normal tissue based on a region of interest approach. The apparent diffusion coefficient (ADC) and arterial spin labelling (ASL) cerebral blood flow (CBF) parameters were also assessed and parametric maps were obtained for all parameters. RESULTS: Significant differences were observed for all diffusion parameters with a significant decrease for D (p < 0.0001), ADC (p < 0.0001), and a significant increase for K (p < 0.0001) in the ischemic lesions of all patients. f decreased significantly in these regions (p = 0.0002). The fD* increase was not significant (p = 0.56). The same significant differences were found with a motion correction except for fD* (p = 0.47). CBF significantly decreased in the lesions. ADC was significantly positively correlated with D (p < 0.0001) and negatively with K (p = 0.0002); K was also negatively significantly correlated with D (p = 0.01). CONCLUSIONS: DKI-IVIM model enables for simultaneous cerebral perfusion and enhanced diffusion characterization in an acceptable clinically acquisition time for the ischemic stroke diagnosis with the additional kurtosis factor estimation, that may better reflect the microstructure heterogeneity.


Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Imageamento por Ressonância Magnética , Imagem de Tensor de Difusão/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Movimento (Física)
4.
MAGMA ; 36(5): 837-847, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36715885

RESUMO

OBJECTIVES: To access the performances of different algorithms for quantification of Intravoxel incoherent motion (IVIM) parameters D, f, [Formula: see text] in Vertebral Bone Marrow (VBM). MATERIALS AND METHODS: Five algorithms were studied: four deterministic algorithms (the One-Step and three segmented methods: Two-Step, Three-Step, and Fixed-[Formula: see text] algorithm) based on the least-squares (LSQ) method and a Bayesian probabilistic algorithm. Numerical simulations and quantification of IVIM parameters D, f, [Formula: see text] in vivo in vertebral bone marrow, were done on six healthy volunteers. The One-way repeated-measures analysis of variance (ANOVA) followed by Bonferroni's multiple comparison test (p value = 0.05) was applied. RESULTS: In numerical simulations, the Bayesian algorithm provided the best estimation of D, f, [Formula: see text] compared to the deterministic algorithms. In vivo VBM-IVIM, the values of D and f estimated by the Bayesian algorithm were close to those of the One-Step method, in contrast to the three segmented methods. DISCUSSION: The comparison of the five algorithms indicates that the Bayesian algorithm provides the best estimation of VBM-IVIM parameters, in both numerical simulations and in vivo data.


Assuntos
Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Medula Óssea/diagnóstico por imagem , Teorema de Bayes , Algoritmos , Movimento (Física)
5.
Invest Radiol ; 57(9): 592-600, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35510874

RESUMO

OBJECTIVE: Cortical lesions are common in multiple sclerosis (MS), but their visualization is challenging on conventional magnetic resonance imaging. The uniform image derived from magnetization prepared 2 rapid acquisition gradient echoes (MP2RAGE uni ) detects cortical lesions with a similar rate as the criterion standard sequence, double inversion recovery. Fluid and white matter suppression (FLAWS) provides multiple reconstructed contrasts acquired during a single acquisition. These contrasts include FLAWS minimum image (FLAWS min ), which provides an exquisite sensitivity to the gray matter signal and therefore may facilitate cortical lesion identification, as well as high contrast FLAWS (FLAWS hco ), which gives a contrast that is similar to one of MP2RAGE uni . In this study, we compared the manual detection rate of cortical lesions on MP2RAGE uni , FLAWS min , and FLAWS hco in MS patients. Furthermore, we assessed whether the combined detection rate on FLAWS min and FLAWS hco was superior to MP2RAGE uni for cortical lesions identification. Last, we compared quantitative T1 maps (qT1) provided by both MP2RAGE and FLAWS in MS lesions. MATERIALS AND METHODS: We included 30 relapsing-remitting MS patients who underwent MP2RAGE and FLAWS magnetic resonance imaging with isotropic spatial resolution of 1 mm at 3 T. Cortical lesions were manually segmented by consensus of 3 trained raters and classified as intracortical or leukocortical lesions on (1) MP2RAGE uniform/flat images, (2) FLAWS min , and (3) FLAWS hco . In addition, segmented lesions on FLAWS min and FLAWS hco were merged to produce a union lesion map (FLAWS min + hco ). Number and volume of all cortical, intracortical, and leukocortical lesions were compared among MP2RAGE uni , FLAWS min , and FLAWS hco using Friedman test and between MP2RAGE uni and FLAWS min + hco using Wilcoxon signed rank test. The FLAWS T1 maps were then compared with the reference MP2RAGE T1 maps using relative differences in percentage. In an exploratory analysis, individual cortical lesion counts of the 3 raters were compared, and interrater variability was quantified using Fleiss Ï°. RESULTS: In total, 633 segmentations were made on the 3 contrasts, corresponding to 355 cortical lesions. The median number and volume of single cortical, intracortical, and leukocortical lesions were comparable among MP2RAGE uni , FLAWS min , and FLAWS hco . In patients with cortical lesions (22/30), median cumulative lesion volume was larger on FLAWS min (587 µL; IQR, 1405 µL) than on MP2RAGE uni (490 µL; IQR, 990 µL; P = 0.04), whereas there was no difference between FLAWS min and FLAWS hco , or FLAWS hco and MP2RAGE uni . FLAWS min + hco showed significantly greater numbers of cortical (median, 4.5; IQR, 15) and leukocortical (median, 3.5; IQR, 12) lesions than MP2RAGE uni (median, 3; IQR, 10; median, 2.5; IQR, 7; both P < 0.001). Interrater agreement was moderate on MP2RAGE uni (Ï° = 0.582) and FLAWS hco (Ï° = 0.584), but substantial on FLAWS min (Ï° = 0.614). qT1 in lesions was similar between MP2RAGE and FLAWS. CONCLUSIONS: Cortical lesions identification in FLAWS min and FLAWS hco was comparable to MP2RAGE uni . The combination of FLAWS min and FLAWS hco allowed to identify a higher number of cortical lesions than MP2RAGE uni , whereas qT1 maps did not differ between the 2 acquisition schemes.


Assuntos
Esclerose Múltipla Recidivante-Remitente , Esclerose Múltipla , Substância Branca , Encéfalo/patologia , Substância Cinzenta/diagnóstico por imagem , Substância Cinzenta/patologia , Humanos , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Esclerose Múltipla Recidivante-Remitente/diagnóstico por imagem , Esclerose Múltipla Recidivante-Remitente/patologia , Substância Branca/diagnóstico por imagem , Substância Branca/patologia
6.
PLoS One ; 17(2): e0247343, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35180211

RESUMO

Magnetic Resonance Imaging (MRI) motion artefacts frequently complicate structural and diffusion MRI analyses. While diffusion imaging is easily 'scrubbed' of motion affected volumes, the same is not true for T1w or T2w 'structural' images. Structural images are critical to most diffusion-imaging pipelines thus their corruption can lead to disproportionate data loss. To enable diffusion-image processing when structural images are missing or have been corrupted, we propose a means by which synthetic structural images can be generated from diffusion MRI. This technique combines multi-tissue constrained spherical deconvolution, which is central to many existing diffusion analyses, with the Bloch equations that allow simulation of MRI intensities for given scanner parameters and magnetic resonance (MR) tissue properties. We applied this technique to 32 scans, including those acquired on different scanners, with different protocols and with pathology present. The resulting synthetic T1w and T2w images were visually convincing and exhibited similar tissue contrast to acquired structural images. These were also of sufficient quality to drive a Freesurfer-based tractographic analysis. In this analysis, probabilistic tractography connecting the thalamus to the primary sensorimotor cortex was delineated with Freesurfer, using either real or synthetic structural images. Tractography for real and synthetic conditions was largely identical in terms of both voxels encountered (Dice 0.88-0.95) and mean fractional anisotropy (intrasubject absolute difference 0.00-0.02). We provide executables for the proposed technique in the hope that these may aid the community in analysing datasets where structural image corruption is common, such as studies of children or cognitively impaired persons.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Líquido Cefalorraquidiano/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Epilepsia/diagnóstico por imagem , Glioma/diagnóstico por imagem , Substância Cinzenta/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Anisotropia , Artefatos , Estudos de Casos e Controles , Simulação por Computador , Conectoma/métodos , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos
7.
J Comput Assist Tomogr ; 46(1): 110-115, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35099142

RESUMO

OBJECTIVE: This initial study aimed to investigate the feasibility of simultaneously measuring perfusion and diffusion including kurtosis features in acute ischemic stroke with the combined intravoxel incoherent motion and non-Gaussian diffusional kurtosis imaging (DKI-IVIM). MATERIAL AND METHODS: Five ischemic stroke patients underwent a 4-minute diffusion weighted imaging (DWI) protocol, using 8 b values chosen with the Cramer-Rao-Lower-Bound optimization approach, in addition to conventional DWI and arterial spin labeling sequences. Regions of interest in pathological and control regions were analyzed with DKI-IVIM, and parametric maps were reconstructed. RESULTS: The IVIM diffusion coefficient (D) decreased (P < 0.0001) in the infarcted areas, whereas higher kurtosis coefficient values were found (P = 0.0002). Regarding the perfusion, the individual IVIM perfusion fraction f decreased in 3 matching cases with the cerebral blood flow estimated through arterial spin labeling and the fD* decreased only in 2 patients of those. CONCLUSIONS: When compared with conventional stroke imaging protocol, DKI-IVIM 4-minute 2-in-1 acquisition can provide diffusion results comparable with conventional DWI with complementary kurtosis estimations but a limited robustness regarding perfusion estimations for clinical purpose.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , Idoso , Idoso de 80 Anos ou mais , Encéfalo/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
MAGMA ; 34(5): 729-740, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33709226

RESUMO

OBJECTIVE: MRI is a reliable and accurate technique to characterize rheumatoid arthritis. The aim of this study was to provide voxel-by-voxel 3D maps of the proton density fat fraction (PDFF), the T1 of water (T1W), the T1 of fat (T1F), the T2* of water (T2*W), the T2* of fat (T2*F) in the wrist bone marrow. MATERIALS AND METHODS: The experiments were conducted on 14 healthy volunteers (mean age: 24 ± 4). The data were acquired at 1.5 T using two optimized four-echo 3D 1.2 × 1.2 × 1.2 mm3-isotropic spoiled gradient sequences. A repeatability study was carried out. The measurements were done using a homemade parametric viewer software. RESULTS: The inter-volunteer results were, on average: PDFF = 86 ± 3%, T1W = 441 ± 113 ms, T1F = 245 ± 19 ms, T2*W = 6 ± 1 ms and T2*F = 16 ± 3 ms. The coefficients of variation were for fat based biomarkers CVPDFF < 5%, CVT1F < 15% and CVT2*F < 10% in the repeatability study. DISCUSSION: The protocol and quantification tool proposed in this study provide high-resolution voxel-by-voxel 3D maps of five biomarkers in the wrist in less than 4 min of acquisition.


Assuntos
Medula Óssea , Punho , Adulto , Biomarcadores , Medula Óssea/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Água , Adulto Jovem
9.
Magn Reson Med ; 85(3): 1364-1378, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32989788

RESUMO

PURPOSE: To demonstrate that fluid and white matter suppression (FLAWS) imaging can be used for high-resolution T1 mapping with low transmitted bias field ( B1+ ) sensitivity at 7T. METHODS: The FLAWS sequence was optimized for 0.8-mm isotropic resolution imaging. The theoretical accuracy and precision of the FLAWS T1 mapping was compared with the one of the magnetization-prepared two rapid gradient echoes (MP2RAGE) sequence optimized for low B1+ sensitivity. FLAWS images were acquired at 7T on six healthy volunteers (21 to 48 years old; two women). MP2RAGE and saturation-prepared with two rapid gradient echoes (SA2RAGE) datasets were also acquired to obtain T1 mapping references and B1+ maps. The contrast-to-noise ratio (CNR) between brain tissues was measured in the FLAWS-hco and MP2RAGE-uni images. The Pearson correlation was measured between the MP2RAGE and FLAWS T1 maps. The effect of B1+ on FLAWS T1 mapping was assessed using the Pearson correlation. RESULTS: The FLAWS-hco images were characterized by a higher brain tissue CNR ( CNRWM/GM=5.5 , CNRWM/CSF=14.7 , CNRGM/CSF=10.3 ) than the MP2RAGE-uni images ( CNRWM/GM=4.9 , CNRWM/CSF=6.6 , CNRGM/CSF=3.7 ). The theoretical accuracy and precision of the FLAWS T1 mapping ( acc=91.9%;prec=90.2% ) were in agreement with those provided by the MP2RAGE T1 mapping ( acc=90.0%;prec=86.8% ). A good agreement was found between in vivo T1 values measured with the MP2RAGE and FLAWS sequences (r = 0.91). A weak correlation was found between the FLAWS T1 map and the B1+ map within cortical gray matter and white matter segmentations ( rWM=-0.026 ; rGM=0.081 ). CONCLUSION: The results from this study suggest that FLAWS is a good candidate for high-resolution T1 -weighted imaging and T1 mapping at the field strength of 7T.


Assuntos
Substância Branca , Adulto , Encéfalo/diagnóstico por imagem , Feminino , Substância Cinzenta/diagnóstico por imagem , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Substância Branca/diagnóstico por imagem , Adulto Jovem
10.
Magn Reson Imaging ; 74: 96-104, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32858181

RESUMO

OBJECT: The MRI tissue characterization of vertebral bone marrow includes the measurement of proton density fat fraction (PDFF), T1 and T2* relaxation times of the water and fat components (T1W, T1F, T2*W, T2*F), IVIM diffusion D, perfusion fraction f and pseudo-diffusion coefficient D*. However, the measurement of these vertebral bone marrow biomarkers (VBMBs) is affected with several confounding factors. In the current study, we investigated these confounding factors including the regional variation taking the example of variation between the anterior and posterior area in lumbar vertebrae, B1 inhomogeneity and the effect of fat suppression on f. MATERIALS AND METHODS: A fat suppressed diffusion-weighted sequence and two 3D gradient multi-echo sequences were used for the measurements of the seven VBMBs. A turbo flash B1 map sequence was used to estimate B1 inhomogeneities and thus, to correct flip angle for T1 quantification. We introduced a correction to perfusion fraction f measured with fat suppression, namely fPDFF. RESULTS: A significant difference in the values of PDFF, f and fPDFF, T1F, T2*W and D was observed between the anterior and posterior region. Although, little variations of flip angle were observed in this anterior-posterior direction in one vertebra but larger variations were observed in head-feet direction from L1 to L5 vertebrae. DISCUSSION: The regional difference in PDFF, fPDFF and T2*W can be ascribed to differences in the trabecular bone density and vascular network within vertebrae. The regional variation of VBMBs shows that care should be taken in reproducing the same region-of-interest location along a longitudinal study. The same attention should be taken while measuring f in fatty environment, and measuring T1. Furthermore, the MRI-protocol presented here allows for measurements of seven VBMBs in less than 6 min and is of interest for longitudinal studies of bone marrow diseases.


Assuntos
Medula Óssea/diagnóstico por imagem , Medula Óssea/metabolismo , Imageamento por Ressonância Magnética , Tecido Adiposo/diagnóstico por imagem , Adulto , Biomarcadores/metabolismo , Feminino , Humanos , Estudos Longitudinais , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade
11.
Med Image Anal ; 61: 101637, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32014805

RESUMO

IntraVoxel Incoherent Motion (IVIM) Diffusion-Weighted Magnetic Resonance Imaging (DW-MRI) is of great interest for evaluating tissue diffusion and perfusion and producing parametric maps in clinical applications for liver pathologies. However, the presence of macroscopic blood vessels (not capillaries) in a given Region of Interest (ROI) results in a confounding effect that bias the quantification of tissue perfusion. Therefore, it is necessary to identify those voxels affected by blood vessels. In this paper, an efficient algorithm for an automatic identification of blood vessels in a given ROI is proposed. It relies on the sparsity of the spatial distribution of blood vessels. This sparsity prior can be easily incorporated using the all-voxel IVIM-MRI model introduced in this paper. In addition to the identification of blood vessels, the proposed algorithm provides a quantification of blood vessels, tissue diffusion and tissue perfusion of all voxels in a given ROI, in one single step. Besides, two strategies are proposed in this paper to deal with the nonnegativity of the model parameters. The efficiency of the proposed algorithm compared to the Non-Negative Least Square (NNLS)-based method, recently introduced to deal with the confounding blood vessel effect in the IVIM-MRI model, is confirmed using both realistic and real DW-MR images.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Fígado/irrigação sanguínea , Humanos , Método de Monte Carlo , Movimento (Física)
12.
Front Behav Neurosci ; 13: 161, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31379533

RESUMO

Psychological chronic stress is an important risk factor for major depressive disorder, of which consequences have been widely studied in rodent models. This work aimed at describing a pig model of chronic stress based on social isolation, environmental impoverishment and unpredictability. Three groups of animals of both sexes were constituted. Two were exposed to the psychosocial stressors while receiving (SF, n = 12) or not (SC, n = 22) the antidepressant fluoxetine, and a third group (NSC, n = 22) remained unstressed. Animals were observed in home pens and during dedicated tests to assess resignation and anxiety-like behaviors. Brain structure and function were evaluated via proton MRS and fMRI. Hippocampal molecular biology and immunodetection of cellular proliferation (Ki67+) and neuron maturation (DCX+) in the dentate gyrus were also performed. Salivary cortisol, fecal short-chain fatty acids (SCFAs), and various plasmatic and intestinal biomarkers were analyzed. Compared to NSC, SC animals showed more resignation (p = 0.019) and had a higher level of salivary cortisol (p = 0.020). SC brain responses to stimulation by a novel odor were lower, similarly to their hippocampal neuronal density (p = 0.015), cellular proliferation (p = 0.030), and hippocampal levels of BDNF and 5-HT1AR (p = 0.056 and p = 0.007, respectively). However, the number of DCX+ cells was higher in the ventral dentate gyrus in this group (p = 0.025). In addition, HOMA-IR was also higher (p < 0.001) and microbiota fermentation activity was lower (SCFAs, SC/NSC: p < 0.01) in SC animals. Fluoxetine partially or totally reversed several of these effects. Exposure to psychosocial stressors in the pig model induced effects consistent with the human and rodent literature, including resignation behavior and alterations of the HPA axis and hippocampus. This model opens the way to innovative translational research exploring the mechanisms of chronic stress and testing intervention strategies with good face validity related to human.

13.
Ann Nucl Med ; 33(1): 47-54, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30219990

RESUMO

AIM: 18F-Choline (FCH) uptake parameters are strong indicators of aggressive disease in prostate cancer. Functional parameters derived by magnetic resonance imaging (MRI) are also correlated to aggressive disease. The aim of this work was to evaluate the relationship between metabolic parameters derived by FCH PET/CT and functional parameters derived by MRI. MATERIALS AND METHODS: Fourteen patients with proven prostate cancer who underwent FCH PET/CT and multiparametric MRI were enrolled. FCH PET/CT consisted in a dual phase: early pelvic list-mode acquisition and late whole-body acquisition. FCH PET/CT and multiparametric MRI examinations were registered and tumoral volume-of-interest were drawn on the largest lesion visualized on the apparent diffusion coefficient (ADC) map and projected onto the different multiparametric MR images and FCH PET/CT images. Concerning the FCH uptake, kinetic parameters were extracted with the best model selected using the Akaike information criterion between the one- and two-tissue compartment models with an imaging-derived plasma input function. Other FCH uptake parameters (early SUVmean and late SUVmean) were extracted. Concerning functional parameters derived by MRI scan, cell density (ADC from diffusion weighting imaging) and vessel permeability (Ktrans and Ve using the Tofts pharmakinetic model from dynamic contrast-enhanced imaging) parameters were extracted. Spearman's correlation coefficients were calculated to compare parameters. RESULTS: The one-tissue compartment model for kinetic analysis of PET images was selected. Concerning correlation analysis between PET parameters, K1 was highly correlated with early SUVmean (r = 0.83, p < 0.001) and moderately correlated with late SUVmean (r = 0.66, p = 0.010) and early SUVmean was highly correlated with late SUVmean (r = 0.90, p < 0.001). No significant correlation was found between functional MRI parameters. Concerning correlation analysis between PET and functional MRI parameters, K1 (from FCH PET/CT imaging) was moderately correlated with Ktrans (from perfusion MR imaging) (r = 0.55, p = 0.041). CONCLUSIONS: No significant correlation was found between FCH PET/CT and multiparametric MRI metrics except FCH influx which is moderately linked to the vessel permeability in prostate cancer.


Assuntos
Colina , Radioisótopos de Flúor , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Humanos , Processamento de Imagem Assistida por Computador , Cinética , Masculino , Pessoa de Meia-Idade
14.
J Magn Reson Imaging ; 49(3): 768-776, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30194746

RESUMO

BACKGROUND: A limited number of studies have used the intravoxel incoherent motion (IVIM) approach on bone marrow. In none of the previous studies were the effects of fat suppression on the IVIM parameters investigated. PURPOSE: To measure the water diffusion coefficient and the perfusion fraction in vertebral bone marrow using IVIM with multishot, readout-segmented (RESOLVE) echo-planar imaging and to assess the effects of different fat suppression techniques on the measurement of the IVIM parameters. STUDY TYPE: Prospective. POPULATION/SUBJECTS: Six healthy volunteers (24.2 ± 4.3 years). FIELD STRENGTH/SEQUENCE: 1.5T, RESOLVE. ASSESSMENT: Four experiments were performed: 1) RESOLVE imaging without fat suppression, 2) with fat saturation (FS), 3) with spectral attenuated inversion recovery (SPAIR), and 4) with short-tau inversion recovery (STIR). The water diffusion coefficient D, pseudo-diffusion coefficient D*, and the perfusion fraction f were assessed in the vertebral bodies of the lumbar vertebrae. STATISTICAL TESTS: One-way repeated-measures analysis of variance (ANOVA) followed by Bonferroni's multiple comparison test. RESULTS: The RESOLVE IVIM protocol allowed for measurement of D, D*, and f in all volunteers. The signal of lipid protons affected the quantification of the IVIM diffusion coefficient: D = 0.24 ± 0.10 (×10-3 mm2 /s), no FS; D = 0.43 ± 0.07 (×10-3 mm2 /s), FS; D = 0.42 ± 0.07 (×10-3 mm2 /s), SPAIR; D = 0.35 ± 0.10 (×10-3 mm2 /s), STIR; and IVIM perfusion fraction f = 7.5 ± 1.9% no FS, f = 14.5 ± 5.4%, FS; f = 12.5 ± 2.6%, SPAIR; f = 18.1 ± 6.1%, STIR. No significant effect (P = 0.36) was found on the quantification of D*. DATA CONCLUSION: An IVIM-MRI protocol using the RESOLVE sequence was implemented for measurements of vertebral bone marrow diffusion and the perfusion. The comparison between the protocols with and without fat suppression indicates that the lipid signal results in an underestimation of both D and f. LEVEL OF EVIDENCE: Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2019;49:768-776.


Assuntos
Medula Óssea/diagnóstico por imagem , Imagem Ecoplanar , Coluna Vertebral/diagnóstico por imagem , Tecido Adiposo/diagnóstico por imagem , Adulto , Algoritmos , Imagem de Difusão por Ressonância Magnética , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Movimento (Física) , Perfusão , Estudos Prospectivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Adulto Jovem
15.
NMR Biomed ; 31(9): e3991, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30040156

RESUMO

INTRODUCTION: The composition of fatty acids in the body is gaining increasing interest, and can be followed up noninvasively by quantitative magnetic resonance spectroscopy (MRS). However, current MRS quantification methods have been shown to provide different quantitative results in terms of lipid signals, with possible varying outcomes for a given biological examination. Quantitative magnetic resonance imaging using multigradient echo sequence (MGE-MRI) has recently been added to MRS approaches. In contrast, these methods fit the undersampled magnetic resonance temporal signal with a simplified model function (expressing the triglyceride [TG] spectrum with only three TG parameters), specific implementations and prior knowledge. In this study, an adaptation of an MGE-MRI method to MRS lipid quantification is proposed. METHODS: Several versions of the method - with time data fully or undersampled, including or excluding the spectral peak T2 knowledge in the fitting - were compared theoretically and on Monte Carlo studies with a time-domain, peak-fitting approach. Robustness, repeatability and accuracy were also inspected on in vitro oil acquisitions and test-retest in vivo subcutaneous adipose tissue acquisitions, adding results from the reference LCModel method. RESULTS: On simulations, the proposed method provided TG parameter estimates with the smallest variability, but with a possible bias, which was mitigated by fitting on undersampled data and considering peak T2 values. For in vitro measurements, estimates for all approaches were correlated with theoretical values and the best concordance was found for the usual MRS method (LCModel and peak fitting). Limited in vivo test-retest variability was found (4.1% for PUFAindx, 0.6% for MUFAindx and 3.6% for SFAindx), as for LCModel (7.6% for PUFAindx, 7.8% for MUFAindx and 3.0% for SFAindx). CONCLUSION: This study shows that fitting the three TG parameters directly on MRS data is one valuable solution to circumvent the poor conditioning of the MRS quantification problem.


Assuntos
Ácidos Graxos/análise , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Processamento de Sinais Assistido por Computador , Tecido Adiposo/metabolismo , Adulto , Simulação por Computador , Humanos , Masculino , Método de Monte Carlo
16.
EJNMMI Res ; 8(1): 49, 2018 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-29904817

RESUMO

BACKGROUND: Suboptimal temporal sampling of time-activity curves (TAC) from dynamic 18F-fluoromethylcholine (FCH) PET images may introduce bias in quantification of FCH uptake in prostate cancer assessment. We sought to define an optimal temporal sampling protocol for dynamic FCH PET imaging. Seven different time samplings were tested: 5 × 60″, 10 × 30″, 15 × 15″-1 × 75″, 6 × 10″-8 × 30″, 12 × 5″-8 × 30″; 10 × 5″-4 × 10″-3 × 20″-5 × 30″, and 8 × 3″-8 × 12″-6 × 30″. First, the irreversible and reversible one-tissue compartment model with blood volume parameter (VB) (respectively, 1T1K+VB and 1T2k+VB, with K1 = transfer coefficient from the arterial blood to the tissue compartment and k2 = transfer coefficient from the tissue compartment to the arterial blood) were compared for 37 lesions from 32 patients who underwent FCH PET imaging for initial or recurrence assessment of prostate cancer, and the model was selected using the Akaike information criterion. To determine the optimal time sampling, K1 values extracted from 1000 noisy-simulated TAC using Monte Carlo method from the seven different time samplings were compared to a target K1 value which is the average of the K1 values extracted from the 37 lesions using an imaging-derived input function for each patient. K1 values extracted with the optimal time sampling for each tumoral lesion were compared to K1 values extracted from each of the other time samplings for the 37 lesions. RESULTS: The 1T2k + VB model was selected. The target K1 value as the objective was 0.506 mL/ccm/min (range 0.216-1.246). Results showed a significant difference between K1 values from the simulated TAC with the seven different time samplings analyzed. The closest K1 value from the simulated TAC to the target K1 value was obtained by the 12 × 5″-8 × 30″ time sampling. Concerning the clinical validation, K1 values extracted from the optimal time sampling (12 × 5″-8 × 30″) were significantly different with K1 values extracted from the other time samplings, except for the comparison with K1 values extracted from the 10 × 5″-4 × 10″-3 × 20″-5 × 30″ time sampling. CONCLUSIONS: A two-phase framing of dynamic PET reconstruction with frame durations of 5 s (blood phase) and 30 s (tissue phase) could be used to sample the TAC for uptake quantification in prostate cancer assessment.

17.
Med Phys ; 45(1): 250-257, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29121397

RESUMO

PURPOSE: The purpose of this study was to implement Virtual Phantom Magnetic Resonance Imaging (ViP MRI), a technique that allows for generating reference signals in MR images using radiofrequency (RF) signals, on a clinical MR system and to test newly designed virtual phantoms. METHODS: MRI experiments were conducted on a 1.5 T MRI scanner. Electromagnetic modelling of the ViP system was done using the principle of reciprocity. The ViP RF signals were generated using a compact waveform generator (dimensions of 26 cm × 18 cm × 16 cm), connected to a homebuilt 25 mm-diameter RF coil. The ViP RF signals were transmitted to the MRI scanner bore, simultaneously with the acquisition of the signal from the object of interest. Different types of MRI data acquisition (2D and 3D gradient-echo) as well as different phantoms, including the Shepp-Logan phantom, were tested. Furthermore, a uniquely designed virtual phantom - in the shape of a grid - was generated; this newly proposed phantom allows for the investigations of the vendor distortion correction field. RESULTS: High quality MR images of virtual phantoms were obtained. An excellent agreement was found between the experimental data and the inverse cube law, which was the expected functional dependence obtained from the electromagnetic modelling of the ViP system. Short-term time stability measurements yielded a coefficient of variation in the signal intensity over time equal to 0.23% and 0.13% for virtual and physical phantom, respectively. MR images of the virtual grid-shaped phantom were reconstructed with the vendor distortion correction; this allowed for a direct visualization of the vendor distortion correction field. Furthermore, as expected from the electromagnetic modelling of the ViP system, a very compact coil (diameter ~ cm) and very small currents (intensity ~ mA) were sufficient to generate a signal comparable to that of physical phantoms in MRI experiments. CONCLUSIONS: The ViP MRI technique was successfully implemented on a clinical MR system. One of the major advantages of ViP MRI over previous approaches is that the generation and transmission of RF signals can be achieved with a self-contained apparatus. As such, the ViP MRI technique is transposable to different platforms (preclinical and clinical) of different vendors. It is also shown here that ViP MRI could be used to generate signals whose characteristics cannot be reproduced by physical objects. This could be exploited to assess MRI system properties, such as the vendor distortion correction field.


Assuntos
Simulação por Computador , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Fenômenos Eletromagnéticos , Imageamento Tridimensional , Ondas de Rádio , Software
18.
J Magn Reson Imaging ; 47(6): 1646-1653, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29135073

RESUMO

BACKGROUND: T2 -weighted imaging (T2 -WI) information has been used in a qualitative manner in the assessment of prostate cancer. Quantitative derivatives (T2 relaxation time) can be generated from T2 -WI. These outputs may be useful in helping to discriminate clinically significant prostate cancer from background signal. PURPOSE/HYPOTHESIS: To investigate changes in quantitative T2 parameters in lesions and noncancerous tissue of men on active surveillance for prostate cancer taking dutasteride 0.5 mg or placebo daily for 6 months. STUDY TYPE: Retrospective. POPULATION/SUBJECTS: Forty men randomized to 6 months of daily dutasteride (n = 20) or placebo (n = 20). FIELD STRENGTH/SEQUENCE: Multiparametric 3T MRI at baseline and 6 months. This included a multiecho MR sequence for quantification of the T2 relaxation times, in three regions of interest (index lesion, noncancerous peripheral [PZ] and transitional [TZ] zones). A synthetic signal contrast (T2 Q contrast) between lesion and noncancerous tissue was assessed using quantitative T2 values. Signal contrast was calculated using the T2 -weighted sequence (T2 W contrast). ASSESSMENT: Two radiologists reviewed the scans in consensus according to Prostate Imaging Reporting and Data System (PI-RADS v. 2) guidelines. STATISTICAL TESTS: Wilcoxon and Mann-Whitney U-tests, Spearman's correlation. RESULTS: When compared to noncancerous tissue, shorter T2 values were observed within lesions at baseline (83.5 and 80.5 msec) and 6 months (81.5 and 81.9 msec) in the placebo and dutasteride arm, respectively. No significant differences for T2 W contrast at baseline and after 6 months were observed, both in the placebo (0.40 [0.29-0.49] vs. 0.43 [0.25-0.49]; P = 0.881) and dutasteride arm (0.35 [0.24-0.47] vs. 0.37 [0.22-0.44]; P = 0.668). There was a significant, positive correlation between the T2 Q contrast and the T2 W contrast values (r = 0.786; P < 0.001). DATA CONCLUSION: The exposure to antiandrogen therapy did not significantly influence the T2 contrast or the T2 relaxation values in men on active surveillance for prostate cancer. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1646-1653.


Assuntos
Inibidores de 5-alfa Redutase/uso terapêutico , Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Antagonistas de Androgênios/uso terapêutico , Biomarcadores Tumorais , Método Duplo-Cego , Dutasterida/uso terapêutico , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Próstata/diagnóstico por imagem , Estudos Retrospectivos
19.
J Comput Assist Tomogr ; 42(1): 85-91, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28708726

RESUMO

OBJECTIVES: The aim of this study was to demonstrate the feasibility to assess cerebral hypoperfusion with a hyperventilation (HV) challenge protocol using intravoxel incoherent motion (IVIM) magnetic resonance imaging. MATERIALS AND METHODS: Magnetic resonance imaging experiments were performed on 10 healthy volunteers at 1.5 T, with a diffusion IVIM magnetic resonance imaging protocol using a set of b-values optimized by Cramer-Rao Lower Bound analysis. Hypoperfusion was induced by an HV maneuver. Measurements were performed in normoventilation and HV conditions. Biexponential curve fitting was used to obtain the perfusion fraction (f), pseudodiffusion coefficient (D*), and the product fD* in gray matter (GM) regions of interest (ROIs). Regional cerebral blood flow in the same ROIs was also assessed with arterial spin labeling. RESULTS: The HV challenge led to a diminution of IVIM perfusion-related parameters, with a decrease of f and fD* in the cerebellum (P = 0.03 for f; P = 0.01 for fD*), thalamus GM (P = 0.09 for f; P = 0.01 for fD*), and lenticular nuclei (P = 0.03 for f; P = 0.02 for fD*). Mean GM cerebral blood flow (in mL/100 g tissue/min) measured with arterial spin labeling averaged over all ROIs also decreased (normoventilation: 42.7 ± 4.1 vs HV: 33.2 ± 2.2, P = 0.004) during the HV challenge. CONCLUSIONS: The optimized IVIM protocol proposed in the current study allows for measurements of cerebral hypoperfusion that might be of great interest for pathologies diagnosis such as ischemic stroke.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/fisiopatologia , Imagem de Difusão por Ressonância Magnética/métodos , Hiperventilação/fisiopatologia , Adulto , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Masculino
20.
MAGMA ; 30(6): 545-554, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28608327

RESUMO

OBJECTIVES: The objectives were to investigate the diffusional kurtosis imaging (DKI) incorporation into the intravoxel incoherent motion (IVIM) model for measurements of cerebral hypoperfusion in healthy subjects. MATERIALS AND METHODS: Eight healthy subjects underwent a hyperventilation challenge with a 4-min diffusion weighted imaging protocol, using 8 b values chosen with the Cramer-Rao Lower Bound optimization approach. Four regions of interest in gray matter (GM) were analyzed with the DKI-IVIM model and the bi-exponential IVIM model, for normoventilation and hyperventilation conditions. RESULTS: A significant reduction in the perfusion fraction (f) and in the product fD* of the perfusion fraction with the pseudodiffusion coefficient (D*) was found with the DKI-IVIM model, during the hyperventilation challenge. In the cerebellum GM, the percentage changes were f: -43.7 ± 40.1, p = 0.011 and fD*: -50.6 ± 32.1, p = 0.011; in thalamus GM, f: -47.7 ± 34.7, p = 0.012 and fD*: -47.2 ± 48.7, p = 0.040. In comparison, using the bi-exponential IVIM model, only a significant decrease in the parameter fD* was observed for the same regions of interest. In frontal-GM and posterior-GM, the reduction in f and fD* did not reach statistical significance, either with DKI-IVIM or the bi-exponential IVIM model. CONCLUSION: When compared to the bi-exponential IVIM model, the DKI-IVIM model displays a higher sensitivity to detect changes in perfusion induced by the hyperventilation condition.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Hiperventilação/diagnóstico por imagem , Adulto , Volume Sanguíneo Cerebral , Circulação Cerebrovascular , Imagem de Difusão por Ressonância Magnética/estatística & dados numéricos , Imagem Ecoplanar/métodos , Imagem Ecoplanar/estatística & dados numéricos , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Masculino , Movimento (Física) , Imagem de Perfusão/métodos , Imagem de Perfusão/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...