1.
Cancers (Basel) ; 16(4)2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38398081

RESUMO

Hodgkin lymphomas are radiosensitive and curable tumors that often involve the mediastinum. However, the application of radiation therapy to the mediastinum is associated with late effects including cardiac and pulmonary toxicities and secondary cancers. The adoption of conformal IMRT and deep inspiration breath- hold (DIBH) can reduce the dose to healthy normal tissues (lungs, heart and breast). We compared the dosimetry of organs at risk (OARs) using different IMRT techniques for two breathing conditions, i.e., deep inspiration breath hold (DIBH) and free breathing. Twenty-three patients with early-stage mediastinal Hodgkin lymphomas were accrued in the prospective study. The patients were given treatment plans which utilized full arc volumetric modulated arc therapy (F-VMAT), Butterfly VMAT (B-VMAT), and fixed field IMRT (FF-IMRT) techniques for both DIBH and free breathing methods, respectively. All the plans were optimized to deliver 95% of the prescription dose which was 25.2 Gy to 95% of the PTV volume. The mean dose and standard error of the mean for each OAR, conformity index (CI), and homogeneity index (HI) for the target using the three planning techniques were calculated and compared using Student's t-test for parametric data and Wilcoxon signed-rank test for non-parametric data. The HI and CI of the target was not compromised using the DIBH technique for mediastinal lymphomas. The mean values of CI and HI for both DIBH and FB were comparable. The mean heart doses were reduced by 2.1 Gy, 2.54 Gy, and 2.38 Gy in DIBH compared to FB for the F-VMAT, B-VMAT, and IMRT techniques, respectively. There was a significant reduction in V5Gy, V10Gy, and V15Gy to the heart (p < 0.005) with DIBH. DIBH reduced the mean dose to the total lung by 1.19 Gy, 1.47 Gy, and 1.3 Gy, respectively. Among the 14 female patients, there was a reduction in the mean right breast dose with DIBH compared to FB (4.47 Gy vs. 3.63 Gy, p = 0.004). DIBH results in lower heart, lung, and breast doses than free breathing in mediastinal Hodgkin Lymphoma. Among the different IMRT techniques, FF-IMRT, B-VMAT, and F-VMAT showed similar PTV coverage, with similar conformity and homogeneity indices. However, the time taken for FF-IMRT was much longer than for the F-VMAT and B-VMAT techniques for both breathing methods. B-VMAT and F-VMAT emerged as the optimal planning techniques able to achieve the best target coverage and lower doses to the OARs, with less time required to deliver the prescribed dose.

2.
Pract Radiat Oncol ; 8(2): e41-e47, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29122556

RESUMO

BACKGROUND: The relationship between frequency of imaging during image guided radiation therapy (IGRT) and planning target volume (PTV) margin remains unclear. This issue is of practical significance given resource and time intensive nature of IGRT. The purpose of this study was to evaluate PTV margins with predefined and commonly used less-than-daily IGRT schedules using data obtained from patients treated with daily IGRT for prostate cancer. METHODS AND MATERIALS: Daily setup error and 3-dimensional daily alignment data for a total of 108 consecutive patients with prostate cancer treated with 2700 fractions of daily image guidance on tomotherapy were retrospectively analyzed. Five IGRT scenarios were simulated: alternate day, twice weekly, once weekly, first 3 days only, and no image guidance. The daily alignment data were modeled to simulate the 5 predefined scenarios by applying appropriate corrections to determine the PTV margin for each image guidance scenario. The data were also analyzed to predict possible geographical miss in any direction using 2 frequently used PTV margins of 7 and 5 mm for all the scenarios. RESULTS: Decreasing the frequency of image guidance increased the mean systematic error and the standard deviation of the systematic error. With decreased image guidance frequency, an increase in PTV margins was required to achieve adequate coverage of the clinical target volume. With reduction in image guidance from 50% to 12%, a gradual increase in percentage of fractions with predicted geographical miss using an isotropic PTV margin of 7 or 5 mm was seen. With every 15% decrease in imaging, a 5% increased risk of geographical miss was estimated. CONCLUSIONS: The use of less-than-daily IGRT requires larger PTV margins for patients treated with intensity modulated radiation therapy for prostate cancer. With every 15% reduction, a 5% increased risk of geographical miss was estimated.


Assuntos
Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem/métodos , Humanos , Masculino , Neoplasias da Próstata/patologia
3.
J Med Phys ; 38(1): 4-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23531765

RESUMO

The objective of this paper was to measure the peripheral dose (PD) with diode and thermoluminescence dosimeter (TLD) for intensity modulated radiotherapy (IMRT) with linear accelerator (conventional LINAC), and tomotherapy (novel LINAC). Ten patients each were selected from Trilogy dual-energy and from Hi-Art II tomotherapy. Two diodes were kept at 20 and 25 cm from treatment field edge. TLDs (LiF:MgTi) were also kept at same distance. TLDs were also kept at 5, 10, and 15 cm from field edge. The TLDs were read with REXON reader. The readings at the respective distance were recorded for both diode and TLD. The PD was estimated by taking the ratio of measured dose at the particular distance to the prescription dose. PD was then compared with diode and TLD for LINAC and tomotherapy. Mean PD for LINAC with TLD and diode was 2.52 cGy (SD 0.69), 2.07 cGy (SD 0.88) at 20 cm, respectively, while at 25 cm, it was 1.94 cGy (SD 0.58) and 1.5 cGy (SD 0.75), respectively. Mean PD for tomotherapy with TLD and diode was 1.681 cGy SD 0.53) and 1.58 (SD 0.44) at 20 cm, respectively. The PD was 1.24 cGy (SD 0.42) and 1.088 cGy (SD 0.35) at 25 cm, respectively, for tomotherapy. Overall, PD from tomotherapy was found lower than LINAC by the factor of 1.2-1.5. PD measurement is essential to find out the potential of secondary cancer. PD for both (conventional LINAC) and novel LINACs (tomotherapy) were measured and compared with each other. The comparison of the values for PD presented in this work and those published in the literature is difficult because of the different experimental conditions. The diode and TLD readings were reproducible and both the detector readings were comparable.