Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Br J Radiol ; 96(1150): 20220583, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37660366

RESUMO

OBJECTIVE: To investigate the incidence of air embolism (AE) related to CT-guided localization of pulmonary ground-glass nodules (GGNs) prior to video-assisted thoracoscopic surgery (VATS). METHODS: The data of all patients who received CT-guided localization of GGNs before VATS from May 2020 to October 2021 were retrospectively analyzed. RESULTS: A total of 1395 consecutive patients with 1553 GGNs were enrolled. AEs occurred in seven patients (0.5%). In four of the seven patients with AE, the embolism was detected before the patients left the CT table and emergency treatments were carried out. Among them, one patient had chest tightness and unilateral limb dyskinesia, one patient had convulsions and transient loss of consciousness, and two patients had no definite clinical symptoms. After a short-term high-flow oxygen inhalation, the clinical symptoms of two patients with symptomatic AE disappeared and two patients with asymptomatic AE did not show any symptoms. In the remaining three patients with AE, the embolism were detected retrospectively when evaluating the images in the PACS for this study. Fortunately, these three patients never developed clinical symptoms related to AE. All seven patients with AE underwent VATS on the day of localization and all GGNs were successfully removed under the guidance of markers. CONCLUSION: The incidence of AE related to CT-guided localization of GGNs was 0.5%, which was significantly higher than expected. Post-localization whole thoracic CT should be performed and observed carefully so as to avoid missed AE and delayed treatment. ADVANCES IN KNOWLEDGE: The incidence of AE related to CT-guided localization of GGNs was 0.5%. In order to timely detect AE, whole thoracic CT scan rather than local CT in the lesion area should be performed after localization. A small amount of AE may be missed if the post- localization CT images are not carefully observed.


Assuntos
Embolia Aérea , Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Nódulo Pulmonar Solitário , Humanos , Neoplasias Pulmonares/patologia , Embolia Aérea/diagnóstico por imagem , Embolia Aérea/etiologia , Estudos Retrospectivos , Nódulo Pulmonar Solitário/cirurgia , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/cirurgia , Tomografia Computadorizada por Raios X/métodos
2.
RSC Adv ; 12(24): 15215-15221, 2022 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-35693227

RESUMO

Traditional matrices for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) are usually crystalline small molecules. The heterogeneous co-crystallization of the analyte and the matrix creates a sweet spot effect and reduces point-to-point reproducibility. In this study, an amorphous poly-N-vinylcarbazole polymer (PVK) was studied as a novel matrix for MALDI-TOF MS to detect various low molecular weight compounds (LMWCs) in the negative ion mode. The PVK achieved excellent matrix action and showed high sensitivity, good salt tolerance, and reproducibility. These results significantly broaden the design rules for new and efficient polymeric MALDI matrices.

3.
Eur Radiol ; 32(7): 4699-4706, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35267089

RESUMO

OBJECTIVES: To evaluate the efficacy and safety of marking ground glass nodules (GGNs) with pulmonary nodules localization needle (PNLN) prior to video-assisted thoracoscopic surgery (VATS). MATERIALS AND METHODS: From June 2020 to February 2021, all patients with GGNs who received CT-guided localization using PNLN before VATS were enrolled. Clinical and imaging data were retrospectively analyzed. RESULTS: A total of 352 consecutive patients with 395 GGNs were included in the study. The mean diameter of GGNs was 0.95 ± 0.48 cm, and the shortest distance from nodules to the pleura was 1.73 ± 0.96 cm. All 395 GGNs were marked using PNLNs. The time required for marking was 7.8 ± 2.2 min. The marking success rate was 99.0% (391/395). The marking failure of four nodules was all due to the unsatisfactory position of PNLNs. No marker dislocation occurred. Marking-related complications included pneumothorax in 63 cases (17.9%), hemorrhage in 34 cases (9.7%), and hemoptysis in 6 cases (1.7%). All the complications were minor and did not need special treatment. Localization and VATS were performed on the same day in 95 cases and on different days in 257 cases. All GGNs were successfully removed by VATS. No patient converted to thoracotomy. Histopathological examination revealed 74 (18.7%) benign nodules and 321 (81.3%) malignant nodules. CONCLUSIONS: It is safe and reliable to perform preoperative localization of GGNs using PNLNs, which can effectively guide VATS to remove GGNs. KEY POINTS: • Preoperative localization of GGNs could effectively guide VATS to remove GGNs. • PNLN was based on the marking principle of hook-wire, through the improvement of its material, specially designed to mark pulmonary nodules. • The application of PNLN to mark GGNs had high success rate, good patient tolerance, and no dislocation. Meanwhile, VATS could be performed 2 to 3 days after marking GGNs with PNLN.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Nódulo Pulmonar Solitário , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/cirurgia , Estudos Retrospectivos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/cirurgia , Cirurgia Torácica Vídeoassistida/métodos
4.
Br J Radiol ; 95(1129): 20200381, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34672681

RESUMO

OBJECTIVES: To evaluate the effect of the position of microcoil proximal end on the incidence of microcoil dislocation during CT-guided microcoil localization of pulmonary nodules (PNs). METHODS: This retrospective study included all patients with PNs who received CT-guided microcoil localization before video-assisted thoracoscopic urgery (VATS) resection from June 2016 to December 2019 in our institution. The microcoil distal end was less than 1 cm away from the nodule, and the microcoil proximal end was in the pleural cavity (the pleural cavity group) or chest wall (the chest wall group). The length of microcoil outside the pleura was measured and divided into less than 0.5 cm (group A), 0.5 to 2 cm (group B) and more than 2 cm (group C). Microcoil dislocation was defined as complete retraction into the lung (type I) or complete withdrawal from the lung (type II). The rate of microcoil dislocation between different groups was compared. RESULTS: A total of 519 consecutive patients with 571 PNs were included in this study. According to the position of microcoils proximal end on post-marking CT, there were 95 microcoils in the pleural cavity group and 476 in the chest wall group. The number of microcoils in group A, B, and C were 67, 448 and 56, respectively. VATS showed dislocation of 42 microcoils, of which 30 were type II and 12 were type I. There was no statistical difference in the rate of microcoil dislocation between the pleural cavity group and the chest wall group (6.3% vs 7.6%, x2 = 0.18, p = 0.433). The difference in the rate of microcoil dislocation among group A, B, and C was statistically significant (11.9%, 5.8%, and 14.3% for group A, B, and C, respectively, x2 = 7.60, p = 0.008). In group A, 75% (6/8) of dislocations were type I, while all eight dislocations were type II in group C. CONCLUSIONS: During CT-guided microcoil localization of PNs, placing the microcoil proximal end in the pleura cavity or chest wall had no significant effect on the incidence of microcoil dislocation. The length of microcoil outside the pleura should be 0.5 to 2 cm to reduce the rate of microcoil dislocation. ADVANCES IN KNOWLEDGE:: CT-guided microcoil localization can effectively guide VATS to resect invisible and impalpable PNs. Microcoil dislocation is the main cause of localization failure. The length of microcoil outside the pleura is significantly correlated with the rate and type of microcoil dislocation. Placing the microcoil proximal end in the pleura cavity or chest wall has no significant effect on the rate of microcoil dislocation.


Assuntos
Marcadores Fiduciais , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Radiografia Intervencionista/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Feminino , Marcadores Fiduciais/efeitos adversos , Marcadores Fiduciais/estatística & dados numéricos , Migração de Corpo Estranho/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Masculino , Nódulos Pulmonares Múltiplos/cirurgia , Cavidade Pleural/diagnóstico por imagem , Estudos Retrospectivos , Nódulo Pulmonar Solitário/cirurgia , Cirurgia Torácica Vídeoassistida , Parede Torácica/diagnóstico por imagem
5.
Korean J Radiol ; 22(7): 1124-1131, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33856129

RESUMO

OBJECTIVE: To evaluate the feasibility, safety, and effectiveness of CT-guided microcoil localization of solitary pulmonary nodules (SPNs) for guiding video-assisted thoracoscopic surgery (VATS). MATERIALS AND METHODS: Between June 2016 and October 2019, 454 consecutive patients with 501 SPNs who received CT-guided microcoil localization before VATS in our institution were enrolled. The diameter of the nodules was 0.93 ± 0.49 cm, and the shortest distance from the nodules to the pleura was 1.41 ± 0.95 cm. The distal end of the microcoil was placed less than 1 cm away from the nodule, and the proximal end was placed outside the visceral pleura. VATS was performed under the guidance of implanted microcoils without the aid of intraoperative fluoroscopy. RESULTS: All 501 nodules were marked with microcoils. The time required for microcoil localization was 12.8 ± 5.2 minutes. Microcoil localization-related complications occurred in 179 cases (39.4%). None of the complications required treatment. A total of 463 nodules were successfully resected under the guidance of implanted microcoils. VATS revealed 38 patients with dislocated microcoils, of which 28 underwent wedge resection (21 cases under the guidance of the bleeding points of pleural puncture, 7 cases through palpation), 5 underwent direct lobectomy, and the remaining 5 underwent a conversion to thoracotomy. In 4 cases, a portion of the microcoil remained in the lung parenchyma. CONCLUSION: CT-guided microcoil localization of SPNs is safe and reliable. Marking the nodule and pleura simultaneously with microcoils can effectively guide the resection of SPNs using VATS without the aid of intraoperative fluoroscopy.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Nódulo Pulmonar Solitário , Fluoroscopia , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/cirurgia , Cuidados Pré-Operatórios , Radiografia Intervencionista , Estudos Retrospectivos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/cirurgia , Cirurgia Torácica Vídeoassistida , Tomografia Computadorizada por Raios X
6.
Br J Radiol ; 94(1118): 20190930, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33245675

RESUMO

OBJECTIVES: To compare CT-guided transthoracic cutting needle biopsy (TCNB) with transthoracic aspiration needle biopsy (TANB) for pulmonary lesions with respect to the diagnostic accuracy and complication rate. METHODS: Of the 859 cases that underwent consecutive CT-guided biopsy of pulmonary lesions, 713 cases confirmed by surgical pathology or clinical follow-up were enrolled. Of these, the first consecutive 275 cases underwent TANB, and the remaining 438 received TCNB. The final diagnosis determined the accuracy of biopsy. Based on the post-biopsy CT and clinical medical records, the presence or absence of biopsy-related complications was determined. The χ2 test was used to compare the differences between TCNB and TANB in terms of diagnostic accuracy and complication rate. RESULTS: Among the 713 biopsy lesions, the final diagnosis was malignant in 411 cases and benign in 302 cases. As compared to TANB, the diagnostic accuracy of TCNB (98.9% vs 93.8%, χ2 = 14.35, p < 0.01), sensitivity to malignant lesions (97.8% vs 90.6%, χ2 = 10.58, p < 0.01), negative predictive value (97.6% vs 84.8%, χ2 = 19.03, p < 0.01), and specific diagnostic rate for benign lesions (73.4% vs 57.9%, χ2 = 7.29, p < 0.01) were improved. On the other hand, a statistical difference was detected between TCNB and TANB with respect to the incidence of pneumothorax (20.6% vs 13.1%, χ2 = 6.46, p = 0.01), hemorrhage (32.2% vs 13.1%, χ2 = 33.03, p < 0.01), and hemoptysis (8.2% vs 3.3%, χ2 = 6.87, p < 0.01). One patient died just several minutes after TCNB due to severe hemorrhage with hemoptysis. CONCLUSIONS: Compared to TANB, CT-guided TCNB improves the diagnostic accuracy of pulmonary lesions, but complication rate increases significantly. ADVANCES IN KNOWLEDGE: In general, TCNB should be recommended, especially for highly suspicious benign lesions. For patients with small lesions adjacent to vessels or vessels within the lesion, TANB should be considered.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Biópsia por Agulha , Desenho de Equipamento , Feminino , Humanos , Biópsia Guiada por Imagem/instrumentação , Biópsia Guiada por Imagem/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Agulhas , Sensibilidade e Especificidade
7.
PLoS One ; 12(7): e0181069, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28715432

RESUMO

OBJECTIVES: To evaluate the value of whole-body magnetic resonance imaging (WBMRI) in diagnosing muscular and extra muscular lesions in patients with polymyositis (PM) and dermatomyositis (DM). METHODS: A retrospective analysis of WBMRI data from PM/DM patients who met the Bohan and Peter diagnostic criteria was performed. X2 test was used to compare the rate of positive diagnosis of newly diagnosed patients using WBMRI, serum creatine kinase test, and EMG. McNemar test was used to compare the performance of WBMRI and chest CT in detecting interstitial lung disease (ILD). RESULTS: The study included 129 patients (30 PM cases and 99 DM cases). Of them, 81.4% (105/129) showed a visible inflammatory muscular edema on their WBMRI; 29.5% (38/129) had varying degrees of fatty infiltration (9 cases with clear muscular atrophy). Of the 66 newly diagnosed patients, the positive rates of WBMRI, muscle biopsy, serum creatine kinase test and EMG were 86.4% (57/66), 92.4% (61/66), 71.2% (47/66) and 71.1% (32/45), respectively. There was no significant difference in the positive rates between WBMRI and muscle biopsy (X2 = 1.28, P = 0.258). The WBMRI had a higher positive rate than both serum creatine kinase test (X2 = 4.53, P = 0.033) and EMG (X2 = 3.92, P = 0.047). In addition to muscular changes, WBMRI also detected interstitial lung disease (ILD) in 38 cases (29.5%), osteonecrosis in 15 cases (11.6%), and neoplastic lesions (5 malignant; 7 benign) in 12 cases (9.3%). Of the 61 patients who underwent routine chest CT examinations, the WBMRI and CT revealed ILD in 29 cases and 35 cases respectively. There was no significant difference in the sensitivity between WBMRI and CT (p = 0.146). CONCLUSIONS: WBMRI is a sensitive, non-invasive and efficient imaging method. It comprehensively displays the extent of muscular involvement in PM/DM patients, and it has the ability to diagnose other associated extra muscular diseases, such as ILD and systemic malignancy. WBMRI can also help screen steroid-induced osteonecrosis.


Assuntos
Dermatomiosite/diagnóstico por imagem , Imageamento por Ressonância Magnética , Polimiosite/diagnóstico por imagem , Imagem Corporal Total , Adolescente , Adulto , Idoso , Criança , Creatina Quinase/sangue , Dermatomiosite/complicações , Feminino , Seguimentos , Humanos , Doenças Pulmonares Intersticiais/complicações , Doenças Pulmonares Intersticiais/diagnóstico , Masculino , Pessoa de Meia-Idade , Músculos/patologia , Neoplasias Nasofaríngeas/diagnóstico , Neoplasias Nasofaríngeas/diagnóstico por imagem , Osteonecrose/complicações , Osteonecrose/diagnóstico , Osteonecrose/diagnóstico por imagem , Polimiosite/complicações , Estudos Retrospectivos , Tórax/diagnóstico por imagem , Adulto Jovem
8.
Br J Radiol ; 89(1068): 20160566, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27662536

RESUMO

OBJECTIVE: To investigate the feasibility and accuracy of T2 weighted spectral pre-saturation inversion recovery combined with fluid-attenuated inversion recovery (T2W SPIR-FLAIR) in the diagnosis of hip synovitis in patients with spondyloarthritis (SpA). METHODS: 10 volunteers underwent a T2W SPIR and 4 T2W SPIR-FLAIR sequence scans with different inversion times (TIs) to determine the optimum TI that could effectively suppress the intra-articular fluid signals. Hip MRI including T2W SPIR-FLAIR and enhanced T1 weighted (T1W) SPIR sequences was performed in 45 patients with SpA and totally 90 hips were evaluated. McNemar's test and Kappa test were used to compare the diagnostic results of synovitis between T2W SPIR-FLAIR and enhanced T1W SPIR. RESULTS: A TI of 2100 ms was selected as the optimum TI. 32 hips from 17 patients exhibited high signal intensity within the articular cavity on both T2W SPIR-FLAIR and enhanced T1W SPIR sequences, while only 3 hips showed high signals within the articular cavity on T2W SPIR-FLAIR. The remaining 55 hips did not show high signals within the articular cavity on both sequences. The T2W SPIR-FLAIR and enhanced T1W SPIR sequences had similar values in the diagnosis of hip synovitis (p = 0.25) and a high degree of diagnostic consistency (Kappa = 0.929). CONCLUSION: T2W SPIR-FLAIR can effectively suppress the intra-articular fluid signals, while retaining the signals of thickened synovial membranes and can be used for the diagnosis of hip synovitis in patients with SpA. Advances in knowledge: The enhanced T1W SPIR is a classic sequence for synovitis diagnosis, but it requires the injection of contrast agents. The T2W SPIR-FLAIR and enhanced T1W SPIR sequences had similar values in the diagnosis of hip synovitis (p = 0.25) and a high degree of diagnostic consistency (Kappa = 0.929).


Assuntos
Articulação do Quadril/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Espondilartrite/complicações , Sinovite/complicações , Sinovite/diagnóstico por imagem , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...