Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Oral Health ; 23(1): 752, 2023 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-37833773

RESUMO

OBJECTIVE: Accurate quantification of the root surface area (RSA) plays a decisive role in the advancement of periodontal, orthodontic, and restorative treatment modalities. In this study, we aimed to develop a dynamic threshold-based computer-aided system for segmentation and calculation of the RSA of isolated teeth on cone-beam computed tomography (CBCT) and to assess the accuracy of the measured data. METHOD: We selected 24 teeth to be extracted, including single-rooted and multi-rooted teeth, from 22 patients who required tooth extraction. In the experimental group, we scanned 24 isolated teeth using CBCT with a voxel size of 0.3 mm. We designed a computer-aided system based on a personalized dynamic threshold algorithm to automatically segment the roots of 24 isolated teeth in CBCT images and calculate the RSA. In the control group, we employed digital intraoral scanner devices to perform optical scanning on 24 isolated teeth and subsequently manually segmented the roots using 3-matic software to calculate the RSA. We used the paired t-test (P < 0.05) and Bland-Altman plots to analyze the consistency of the two measurement methods. RESULTS: The results of the paired t-test showed that there was no significant difference in the RSAs obtained using the dynamic threshold method and the optical scanning image reconstruction (t = 1.005, P = 0.325 > 0.05). As per the Bland-Altman plot, the results were evenly distributed within the region of ± 1.96 standard deviations of the mean, with no increasing or decreasing trends and good consistency. CONCLUSION: In this study, we designed a computer-aided root segmentation system based on a personalized dynamic threshold algorithm to automatically segment the roots of isolated teeth in CBCT images with a voxel size of 0.3 mm. We found that the RSA calculated using this approach was highly accurate, and a voxel of 0.3 mm in size could accurately display the surface area data in CBCT images. Overall, our findings in this study provide a foundation for future work on accurate automatic segmentation of tooth roots in full-mouth CBCT images and the computation of RSA.


Assuntos
Dente , Humanos , Raiz Dentária/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Software
2.
Contrast Media Mol Imaging ; 2018: 8439162, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30670934

RESUMO

Purposes: Chlorotoxin can specifically bind to matrix metalloproteinase 2 (MMP-2), which are overexpressed in the glioma. In this work, radiosynthesis of [18F]-fluoropropionyl-chlorotoxin ([18F]-FP-chlorotoxin) as a novel PET tracer was investigated, and biodistribution in vivo and PET imaging were performed in the C6 glioma model. Procedures: [18F]-FP-chlorotoxin was prepared from the reaction of chlorotoxin with [18F]-NFB (4-nitrophenyl 2-[18F]-fluoropropionate), which was synthesized from multistep reactions. Biodistribution was determined in 20 normal Kunming mice. Small-animal PET imaging with [18F]-FP-chlorotoxin was performed on the same rats bearing orthotopic C6 glioma at different time points (60 min, 90 min, and 120 min) after injection and compared with 2-deoxy-2-[18F] fluoro-D-glucose ([18F]-FDG). Results: [18F]-FP-Chlorotoxin was successfully synthesized in the radiochemical yield of 41% and the radiochemical purity of more than 98%. Among all the organs, the brain had the lowest and stable uptake of [18F]-FP-chlorotoxin, while the kidney showed the highest uptake. Compared with [18F]-FDG, a low uptake of [18F]-FP-chlorotoxin was detected in normal brain parenchyma and a high accumulation of [18F]-FP-chlorotoxin was found in the gliomas tissue. The glioma to normal brain uptake ratio of [18F]-FP-chlorotoxin was higher than that of [18F]-FDG. Furthermore, the uptake of [18F]-FP-chlorotoxin at 90 min after injection was better than that at 60 min after injection. Conclusions: Compared with [18F]-FDG, [18F]-FP-chlorotoxin has a low and stable uptake in normal brain parenchyma. [18F]-FP-Chlorotoxin seems to be a potential PET tracer with a good performance in diagnosis of the glioma.


Assuntos
Radioisótopos de Flúor/química , Glioma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/síntese química , Venenos de Escorpião/química , Animais , Linhagem Celular Tumoral , Fluordesoxiglucose F18 , Camundongos , Compostos Radiofarmacêuticos/farmacologia , Ratos , Venenos de Escorpião/farmacocinética , Distribuição Tecidual , Transplante Heterólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...