Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Omega ; 7(48): 43582-43588, 2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36506146

RESUMO

To make ionic liquids (ILs) accessible and economical, ethylene glycol was mixed in 1-ethyl-3-methylimidazolium-dicyanamide ([EMIm]DCA) to obtain droplets that could experimentally collide white fuming nitric acid. To investigate the ignition delay (ID) time theoretically in terms of hydrodynamics, alcohol fuels and kerosene were used as combustibles, while the intermiscibility between them and nitric acid (HNO3) was calculated using the ternary phase-field method alongside finite element analysis. The specific impulses of blend fuels were calculated by a thermodynamic method and compared to ILs. When the droplet was ethylene glycol/[EMIm]DCA with a 2.1 mm diameter and a 1.69 m/s colliding velocity, the ID time was the shortest. Kerosene was not an applicable additive for [EMIm]DCA owing to its lower intermiscibility with ILs and HNO3 than alcohol fuels; alcohol fuels, however, were appropriate. The concentration of ethylene glycol in the oxidizer pool increased faster than the concentration of propylene glycol, triggering more rapid hypergolic ignition in the first 50 ms. The protocols regarding the hypergolic ignition conditions were verified, i.e., the size of the droplet had to be minute when the colliding velocity was as fast as possible; this was carefully calculated using ethylene glycol. According to thermodynamic calculations, the addition of alcohol fuels can improve the specific impulse of fuels, with ethylene glycol performing the best. The feasibility of adding alcohol fuels to ILs was confirmed via experiments and thermodynamic computations, with the simulation results providing some guidance on selecting the experimental or engineering conditions or both.

2.
Int J Hyperthermia ; 39(1): 1017-1025, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35912525

RESUMO

INTRODUCTION: This study aims to investigate the feasibility of a noninvasive handheld electroporation pulses delivery device (EPDD) for electroporation-based treatment (EBT) of skin superficial lesions through numerical analysis and animal study. METHODS: Finite element analysis was performed to investigate the performance of the EPDD. The electric field, temperature, EI and TI were calculated under pulse voltages of 600, 800, and 1000 V. A mouse subcutaneous tumor model was established to evaluate the performance of the EPDD through histopathology and survival analyses. RESULTS: The electrical field strength increased from 151 (600 V) to 252 V/cm (1000 V) in the skin and from 1302 (600 V) to 2171 V/cm (1000 V) in the tumor. The volume of EI grew and reached a plateau at the 165th pulse, whereas the maximum volume of EI increased with higher voltage. The growth tendency of TI differed between groups, and it was higher in the high-voltage group (HVG) than in the low-voltage group. Histopathological analysis showed that the depth and range of the ablation area could be controlled by adjusting pulse voltage. Survival analysis showed that the survival of the HVG was better than that of the low-voltage and the control group (p < 0.01). CONCLUSIONS: The results demonstrate that the EPDD is feasible, safe, and effective for skin EBT. The volume of EP tissue injury can be controlled by adjusting the pulse voltage, pulse number, and other parameters. The proposed noninvasive handheld EPDD can be a potential therapeutic tool for EBT of superficial skin lesions in the future.


Assuntos
Eletroporação , Pele , Animais , Modelos Animais de Doenças , Eletroporação/métodos , Camundongos
3.
J Affect Disord ; 301: 300-306, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35051441

RESUMO

BACKGROUND: Elderly individuals who experience falls suffer from higher levels of anxiety because of physical or mental injury. This study examined the association between falls and anxiety among elderly Chinese individuals. It also explored the mediating roles of functional ability and social participation in the link between falls and anxiety. METHODS: The analytical sample included 8233 elderly people aged 60 and above, and prospective data were obtained from the Chinese Longitudinal Healthy Longevity Survey (CLHLS). Anxiety was evaluated by a 7-item Generalized Anxiety Disorder (GAD-7) scale, and falls were determined by self-report. The association between falls and anxiety was assessed by linear regression. Mediation analysis was used to explore the potential mediating roles of functional ability and social participation on the association between falls and anxiety. RESULTS: Suffering falls predicted higher anxiety levels among elderly individuals (B = 0.608, 95% CI: 0.471, 0.746). Functional ability and social participation play partial mediating roles in the association between falls and anxiety, and the mediating effects were 0.036 (95% CI: 0.020, 0.058) and 0.005 (95% CI: 0.003, 0.014), respectively. The serial mediating effect of functional ability and social participation on the association between falls and anxiety was 0.003 (95% CI: 0.002, 0.005). LIMITATIONS: This study is based upon cross-sectional data, which limit inferring causality. CONCLUSIONS: This study suggests that policy-makers should explore how to encourage elderly individuals who experience falls to restore functional ability and participate in appropriate social activities to alleviate anxiety.


Assuntos
Acidentes por Quedas , Participação Social , Idoso , Ansiedade/epidemiologia , Transtornos de Ansiedade/epidemiologia , China/epidemiologia , Estudos Transversais , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
4.
Surg Endosc ; 35(10): 5665-5674, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33420599

RESUMO

BACKGROUND: The aim of this study was to evaluate the feasibility, safety, and efficacy of magnetic anchoring and guidance-assisted endoscopic irreversible electroporation (MAG-IRE) for gastric mucosal ablation. METHODS: A catheter-based, donut-like, and MAG-assisted electrode was developed. MAG-IRE for gastric mucosal ablation was performed in eight beagle canines. The parameters of one set of IRE was 500 V voltage, 100 µs pulse duration, and 99 pulses. The MAG time, operation time, success rate, and adverse events were measured. Endoscopic examination was performed from 30 min to 28 days post-IRE. Full-thickness gastric tissue was harvested by wedge biopsy for histopathological analysis. RESULTS: 30 (93.75%) of the 32 lesions were successfully ablated by MAG-IRE. The median MAG time was 300 s (IQR 120-422.5 s), and the median operation time was 491.5 s (IQR 358.3-632.5 s). No adverse events occurred. Ulceration was observed, starting from 3 days post-IRE. The mucosa healed 14 to 28 days post-IRE. Hematoxylin-Eosin (H&E) staining showed inflammatory infiltration, edema, and congestion in the ablated mucosa. Masson's Trichrome staining showed that the gastric wall and blood vessels in the ablation area were intact. TUNEL assay showed diffuse positive cells in ablated mucosa as early as 30 min post-IRE. CONCLUSIONS: MAG-IRE for gastric mucosal ablation is feasible, safe, and effective. It can be a potential therapeutic option for minimally invasive treatment of gastric neoplasm.


Assuntos
Técnicas de Ablação , Eletroporação , Animais , Cães , Endoscopia , Mucosa Gástrica/cirurgia , Fenômenos Magnéticos
5.
Int J Hyperthermia ; 36(1): 854-867, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31452435

RESUMO

Introduction: Irreversible electroporation (IRE) combined with a catheter-based electrode during endoscopy is a potential alternative treatment method for digestive tract tumors. The aim of this study was to investigate the electrical injury (EI) and thermal injury (TI) to the digestive tract via numerical analyses and to evaluate the role and impact of electrode configurations and pulse settings on the efficacy and outcomes of IRE. Materials and methods: A finite element method was used to solve the numerical model. A digestive tract model having 4-mm-thick walls and two catheter-based electrode configuration models were constructed. The distributions of electric fields, temperature, electrical conductivity, tissue injury and limitation on the pulse number required for IRE were calculated and compared. Results: Electrode length is an important geometric parameter for electrodes in the monopolar model (MPM), while electrode spacing affects the outcomes in the bipolar model (BPM). Increasing the pulse voltage reduces the pulse number required for tissue ablation, while increasing the risk of TI. In total, there were 6 NT-IRE protocols, 12 thermal-IRE protocols and 30 TI protocols. All of the NT-IRE protocols were set in BPMs with a voltage of 0.50 kV. With increasing electrode spacing, the minimum pulse number decreased. However, thermal effects were inevitable in the MPM. Conclusions: The electrode configuration and pulse settings are adjusted to achieve NT-IRE synergistically. The BPM is more reliable for achieving NT-IRE in 4-mm-thick digestive wall. Future in vitro and in vivo studies are needed to support and validate this conclusion.


Assuntos
Técnicas de Ablação , Eletroporação , Trato Gastrointestinal/lesões , Modelos Biológicos , Catéteres , Condutividade Elétrica , Eletrodos , Neoplasias Gastrointestinais/terapia , Temperatura Alta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...