Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Front Cardiovasc Med ; 9: 887664, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35935621

RESUMO

Background: Aortic valve replacement is the gold standard treatment for severe symptomatic aortic stenosis, but thrombosis of bioprosthetic valves (PVT) remains a concern. Objective: To analyze the factors involved in the contact pathway during aortic valve replacement and to assess their impact on the development of thromboembolic complications. Methods: The study was conducted in 232 consecutive patients who underwent: transcatheter aortic valve replacement (TAVR, N = 155), and surgical valve replacement (SAVR, N = 77) (MUVITAVI project). Demographic and clinical data, outcomes including a combined end point (CEP) of thrombotic events, and imaging controls were recruited. Samples were collected 24 h before and 48 h after valve replacement. FXII, FXI and (pre)kallikrein were evaluated by Western Blot and specific ELISA with nanobodies. Results: The CEP of thrombotic events was reached by 19 patients: 13 patients presented systemic embolic events and 6 patients subclinical PVT. Valve replacement did not cause FXII activation or generation of kallikrein. There was a significant reduction of FXI levels associated with the procedure, which was statistically more pronounced in SAVR than in TAVR. Cases with reductions of FXI below 80% of basal values had a lower incidence of embolic events during the procedure than patients in whom FXI increased above 150%: 2.7 vs. 16.7%; p: 0.04. Conclusion: TAVR or SAVR did not significantly activate the contact pathway. A significant reduction of FXI, was observed, particularly in SAVR, associated with lower incidence of thrombotic events. These results encourage evaluating the usefulness and safety of FXI-directed antithrombotic treatments in these patients.

2.
Eur J Appl Physiol ; 122(4): 945-954, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35059801

RESUMO

PURPOSE: The aim of the present investigation is to study the relationship of ventricular global longitudinal strain (GLS) and ultrasound lung comets (ULC) formation to establish a link between extravascular pulmonary water formation and cardiac contractile dysfunction. METHODS: This is a prospective observational study including 14 active military divers. The subjects performed two sea dives of 120 min each with a semi-closed SCUBA circuit at 10 m depth. Divers were examined at baseline, 15 min (D1) and 60 min (D2) after diving. The evaluation included pulmonary and cardiac echography (including speckle tracking techniques). Blood samples were drawn at baseline and after diving, assessing hs-TnT and Endothelin-1. RESULTS: ULC were detected in 9 (64.2%) and 8 (57.1%) of the subjects after D1 and D2 respectively. No differences were found in right and left ventricular GLS after both immersions (RV: Baseline: - 17.9 4.9 vs. D1: - 17.2 6.5 and D2: - 16.7 5.8 s-1; p = 0.757 and p = 0.529; LV: Baseline: - 17.0 2.3 vs. D1: - 17.4 2.1 and D2: - 16.9 2.2 s-1; p = 0.546 and p = 0.783). However, a decrease in atrial longitudinal strain parameters have been detected after diving (RA: Baseline: 35.5 9.2 vs. D1: 30.3 12.8 and D2: 30.7 13.0 s-1; p = 0.088 and p = 0.063; LA: Baseline: 39.0 10.0 vs. D1: 31.6 6.1 and D2: 32.4 10.6 s-1; p = 0.019 and p = 0.054). CONCLUSION: In the present study, no ventricular contractile dysfunction was observed. However, increase pulmonary vasoconstriction markers were present after diving.


Assuntos
Mergulho , Água Extravascular Pulmonar , Ecocardiografia , Água Extravascular Pulmonar/diagnóstico por imagem , Humanos , Contração Miocárdica , Ultrassonografia
5.
J Am Soc Echocardiogr ; 30(1): 28-35, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27887818

RESUMO

BACKGROUND: Left ventricular outflow tract (LVOT) measurement is a critical step in the quantification of aortic valve area. The assumption of a circular morphology of the LVOT may induce some errors. The aim of this study was to assess the three-dimensional (3D) morphology of the LVOT and its impact on grading aortic stenosis severity. METHODS: Fifty-eight patients with aortic stenosis were studied retrospectively. LVOT dimensions were measured using 3D transesophageal echocardiography at three levels: at the hinge points (HP) of the aortic valve and at 4 and 8 mm proximal to the annular plane. Results were compared with standard two-dimensional echocardiographic measurements. RESULTS: Three-dimensional transesophageal echocardiography showed a funnel shape that was more circular at the HP and more elliptical at 4 and 8 mm proximal to the annular plane (circularity index = 0.92 vs 0.83 vs 0.76, P < .001). Cross-sectional area was smaller at the HP and larger at 4 and 8 mm from the annular plane (3.6 vs 3.9 vs 4.1 cm2, P = .001). The best correlation between two-dimensional and 3D transesophageal echocardiographic dimensions was at the HP (intraclass correlation coefficient = 0.75; 95% CI, 0.59-0.86). When the HP approach was selected, there was a reduction in the percentage of patients with low flow (from 41% to 29%). CONCLUSIONS: A large portion of patients with aortic stenosis have funnel-shaped and elliptical LVOTs, a morphology that is more pronounced in the region farther from the annular plane. Two-dimensional LVOT measurement closer to the annular plane has the best correlation with 3D measurements. Measurement of the LVOT closer to the annular plane should be encouraged to reduce measurement errors.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Ecocardiografia Tridimensional/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Interpretação de Imagem Assistida por Computador/métodos , Idoso , Estenose da Valva Aórtica/classificação , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
6.
Echocardiography ; 32(3): 508-15, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25041359

RESUMO

AIMS: To assess the feasibility and reliability of aortic valve area (AVA) planimetry by means of three-dimensional transesophageal echocardiography (3DTEE) as compared with the transthoracic echocardiogram (TTE) calculation of AVA, to determine the systematic deviations between measurements, and to describe the distribution of mean systolic in relation with 3DTEE anatomical AVA. METHODS AND RESULTS: Three hundred seven patients with aortic valve stenosis (AVS) underwent both TTE and 3DTEE for AVA measurement by means of the continuity equation and direct anatomical planimetry, respectively. AVA planimetry was achieved in 282 (91.9%) of patients. Severity of the aortic valve calcification was independently associated with a poorer performance of planimetry. Intraclass correlation coefficient yielded a 0.848 (95% CI: 0.807-0.879) value. 3DTEE rendered a mild constant underestimation of AVA in comparison with TTE. Severe aortic stenosis according to the area criterion (<1 cm(2) ) despite mean systolic gradient below 40 mm Hg was detected in 37.6% of the study population, and in 33.7% of the subset of patients with preserved left ventricular ejection fraction. CONCLUSIONS: Reliability of AVA planimetry by 3DTEE in comparison with the calculation by TTE is good, but 3DTEE underestimates slightly the measurement. Feasibility of the technique is good but independently affected by valvular calcification. Inconsistent classification of AVS severity as graded by AVA or mean systolic gradient is observed in the overall population and in patients with preserved systolic function.


Assuntos
Algoritmos , Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Interpretação de Imagem Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Eur J Clin Invest ; 45(1): 18-26, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25402558

RESUMO

BACKGROUND: Paravalvular aortic regurgitation after transcatheter aortic valve implantation is associated with a hemodynamic deterioration and a poor outcome. We aim to determine the early hemodynamic effect of paravalvular aortic regurgitation in relation with the change in the left ventricle filling pattern and to assess their clinical outcome. MATERIAL AND METHODS: Eighty-two consecutive patients referred for transcatheter aortic valve implantation were included. Patients were classified according to the change in the left ventricular filling pattern, and significant paravalvular aortic regurgitation (grade ≥ 2) was reported. Follow-up and incidence of death and hospitalization for heart failure were reported. RESULTS: Sixteen patients (19·5%) presented a worsening of left ventricular filling pattern. The incidence of significant paravalvular aortic regurgitation was higher in the group with a worsening of left ventricular filling pattern (56·3% vs. 19·7%; P = 0·009). In the multivariate analysis, the only variable significantly associated with the worsening of left ventricular filling pattern was the significant paravalvular aortic regurgitation (OR 4·84; 95% CI 1·23 - 19·1; P = 0·024). During the follow-up (642·5 days), there was a higher incidence of the endpoint of death or hospitalization for heart failure in the group with a worsening of left ventricular filling pattern (62·5% vs. 31·8%; P = 0·042) and a lower event-free survival rate (long rank test = 0·013). CONCLUSIONS: The presence of a significant paravalvular aortic regurgitation is associated with a worsening in parameters of diastolic function. This finding should alert the cardiologist as patients with a worsening of left ventricular filling pattern present a higher incidence of paravalvular aortic regurgitation and a less favourable outcome.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Disfunção Ventricular Esquerda/etiologia , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/fisiopatologia , Progressão da Doença , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
8.
Rev. esp. cardiol. (Ed. impr.) ; 66(4): 255-260, abr. 2013.
Artigo em Espanhol | IBECS | ID: ibc-111097

RESUMO

Introducción y objetivos. La estenosis aórtica grave con gradientes bajos y fracción de eyección normal es una entidad discutida. Las discrepancias sobre su pronóstico indican que podría tratarse de una incorrecta clasificación de su gravedad. La planimetría del área aórtica mediante ecografía transesofágica tridimensional podría esclarecer estas dudas. Los objetivos de este trabajo son valorar la concordancia de la medida del área valvular aórtica obtenida mediante ecuación de continuidad en ecocardiografía transtorácica y la obtenida por planimetría mediante ecocardiografía transesofágica tridimensional en pacientes con estenosis aórtica grave y bajo gradiente paradójico. Métodos. Estudio transversal descriptivo de pacientes consecutivos remitidos por estenosis aórtica grave, a los que se practicó ecocardiografía transtorácica y transesofágica tridimensional. Se consideró estenosis aórtica con bajo gradiente paradójico la presencia de un área efectiva < 1 cm2, gradiente ventricular medio < 40 mmHg y fracción de eyección >= 50%. Se estudió la concordancia entre las dos técnicas. Resultados. Estudiamos a 212 pacientes consecutivos con estenosis aórtica grave. De ellos, 63 casos (29,7%) satisfacían los criterios de bajo gradiente paradójico y en 61 se obtuvieron imágenes adecuadas para la comparación de los métodos. La planimetría tridimensional confirmó un área valvular < 1 cm2 en 52 pacientes (85,2%). El coeficiente de correlación intraclase entre las técnicas fue 0,505 (intervalo de confianza del 95%, 0,290-0,671; p < 0,001). Conclusiones. La estenosis aórtica grave con bajo gradiente paradójico es una entidad real que se confirma en el 85% de los pacientes evaluados mediante ecocardiografía transesofágica tridimensional (AU)


Introduction and objectives. Low-gradient severe aortic stenosis with preserved ejection fraction is a controversial entity. Misclassification of valvulopathy severity could explain the inconsistencies reported in the prognosis of these patients. Planimetry of the aortic area using three-dimensional transesophageal echocardiography could clear up these doubts. The objectives were to assess the agreement between measurements of the valvular aortic area by continuity equation in transthoracic echocardiography and that obtained through planimetry with three-dimensional transesophageal echocardiography in low-gradient severe aortic stenosis patients. Methods. Cross-sectional descriptive study of consecutive patients referred due to severe aortic stenosis. Patients underwent transthoracic echocardiography and three-dimensional transesophageal echocardiography. Paradoxical low-gradient severe aortic stenosis was defined by the presence in the transthoracic echocardiography of aortic valve area<1 cm2, mean ventricular gradient<40mmHg, and ejection fraction >=50%. Concordance between the two techniques was evaluated. Results. Of 212 consecutive severe aortic stenosis patients evaluated, 63 cases (29.7%) fulfilled the paradoxical low-gradient inclusion criteria. We obtained three-dimensional aortic valve planimetry in 61 (96.8%) of those patients. In 52 patients (85.2%), aortic valve area by transesophageal echocardiography was <1 cm2. The intraclass correlation coefficient between the two methods was 0.505 (95% confidence interval, 0.290-0.671; P<.001). Conclusions. Paradoxical low-gradient severe aortic stenosis is an actual entity, confirmed in 85% of cases evaluated by three-dimensional transesophageal echocardiography (AU)


Assuntos
Humanos , Masculino , Feminino , Estenose da Valva Aórtica/classificação , Estenose da Valva Aórtica/complicações , Ecocardiografia/métodos , Ecocardiografia , Prognóstico , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica , Consentimento Livre e Esclarecido/normas , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas
9.
Rev. esp. cardiol. (Ed. impr.) ; 66(2): 98-103, feb. 2013. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-109029

RESUMO

Introducción y objetivos. En pacientes con miocardiopatía hipertrófica, los datos ecocardiográficos en reposo han mostrado una pobre correlación con la capacidad de ejercicio. Investigamos si la ecografía Doppler de esfuerzo podría explicar mejor la limitación funcional. Métodos. Estudiamos a 87 pacientes consecutivos, remitidos para test cardiopulmonar y ecografía de esfuerzo. Se realizó estudio basal y en el pico de ejercicio para evaluar el gradiente máximo, la regurgitación mitral y las velocidades diastólicas mitral y del Doppler tisular del anillo. Resultados. Desarrollaron obstrucción con el ejercicio 43 pacientes. Estos alcanzaron un menor consumo de oxígeno (21,3 ± 5,7 frente a 24,6 ± 6,1ml/kg/min; p = 0,012), presentaban mayor volumen auricular izquierdo (42,1 ± 14,5 frente a 31,1 ± 11,6ml/m2; p < 0,001) y desarrollaron más regurgitación mitral y mayor relación E/E’ con el ejercicio. Los datos de ejercicio mejoraron el poder predictivo de la capacidad funcional (R2 ajustada = 0,49 frente a R2 ajustada = 0,38 en reposo). La edad, el volumen auricular izquierdo, la relación E/E’ con el ejercicio y la obstrucción fueron los factores independientes asociados con la capacidad funcional. En los pacientes sin obstrucción, los volúmenes de las cavidades izquierdas fueron los factores determinantes. Conclusiones. En pacientes con miocardiopatía hipertrófica, la obstrucción con el esfuerzo y el volumen auricular izquierdo son los principales determinantes de la limitación funcional. Los parámetros diastólicos de esfuerzo mejoran la predicción de la capacidad funcional, aunque su poder predictivo no supera el 50%. En pacientes sin obstrucción, los volúmenes de las cavidades izquierdas son los factores determinantes (AU)


Introduction and objectives. At-rest echocardiography is a poor predictor of exercise capacity in patients with hypertrophic cardiomyopathy. We aimed to test the performance of treadmill exercise Doppler echocardiography in the prediction of functional limitations in these patients. Methods. Eighty-seven consecutive patients with hypertrophic cardiomyopathy underwent treadmill exercise echocardiography with direct measurement of oxygen consumption. Both at rest and at peak exercise, the mitral inflow, mitral regurgitation, left ventricular outflow tract obstruction and mitral annulus velocities were assessed. Results. Forty-three patients developed left ventricular outflow tract obstruction during exercise, which significantly decreased oxygen consumption (21.3 [5.7] mL/kg/min vs 24.6 [6.1] mL/kg/min; P=.012), and had greater left atrial volume (42.1 [14.5] mL/m2 vs 31.1 [11.6] mL/m2; P<.001) and a higher degree of mitral regurgitation and E/E’ ratio during exercise. Exercise variables improved the predictive value of functional capacity (adjusted R2 rose from 0.38 to 0.49). Independent predictors of oxygen consumption were age, left atrial volume, E/E’ ratio and the presence of left ventricular outflow tract obstruction. In a subset of patients without left ventricular outflow obstruction, only left ventricular and atrial volume indexes were independent predictors of exercise capacity. Conclusions. In patients with hypertrophic cardiomyopathy, left ventricular outflow tract obstruction and left atrial volume are the main predictors of exercise capacity. Exercise echocardiography is a better predictor of functional performance than at-rest echocardiography, although its predictive power is under 50%. In nonobstructed patients, left atrial and ventricular volumes were the independent factors (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Exercício Físico/fisiologia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Ecocardiografia sob Estresse/instrumentação , Ecocardiografia sob Estresse , Consumo de Oxigênio/fisiologia , Ecocardiografia Doppler , Cardiomiopatia Hipertrófica/fisiopatologia , Cardiomiopatia Hipertrófica , Ecocardiografia sob Estresse/tendências , Efeito Doppler , 28599
10.
Rev Esp Cardiol (Engl Ed) ; 66(2): 98-103, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24775382

RESUMO

INTRODUCTION AND OBJECTIVES: At-rest echocardiography is a poor predictor of exercise capacity in patients with hypertrophic cardiomyopathy. We aimed to test the performance of treadmill exercise Doppler echocardiography in the prediction of functional limitations in these patients. METHODS: Eighty-seven consecutive patients with hypertrophic cardiomyopathy underwent treadmill exercise echocardiography with direct measurement of oxygen consumption. Both at rest and at peak exercise, the mitral inflow, mitral regurgitation, left ventricular outflow tract obstruction and mitral annulus velocities were assessed. RESULTS: Forty-three patients developed left ventricular outflow tract obstruction during exercise, which significantly decreased oxygen consumption (21.3 [5.7] mL/kg/min vs 24.6 [6.1] mL/kg/min; P=.012), and had greater left atrial volume (42.1 [14.5] mL/m(2) vs 31.1 [11.6] mL/m(2); P<.001) and a higher degree of mitral regurgitation and E/E' ratio during exercise. Exercise variables improved the predictive value of functional capacity (adjusted R(2) rose from 0.38 to 0.49). Independent predictors of oxygen consumption were age, left atrial volume, E/E' ratio and the presence of left ventricular outflow tract obstruction. In a subset of patients without left ventricular outflow obstruction, only left ventricular and atrial volume indexes were independent predictors of exercise capacity. CONCLUSIONS: In patients with hypertrophic cardiomyopathy, left ventricular outflow tract obstruction and left atrial volume are the main predictors of exercise capacity. Exercise echocardiography is a better predictor of functional performance than at-rest echocardiography, although its predictive power is under 50%. In nonobstructed patients, left atrial and ventricular volumes were the independent factors.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/fisiopatologia , Ecocardiografia Doppler , Teste de Esforço , Tolerância ao Exercício , Cardiomiopatia Hipertrófica/complicações , Teste de Esforço/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Obstrução do Fluxo Ventricular Externo/complicações , Obstrução do Fluxo Ventricular Externo/fisiopatologia
11.
Rev Esp Cardiol (Engl Ed) ; 66(4): 255-60, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24775614

RESUMO

INTRODUCTION AND OBJECTIVES: Low-gradient severe aortic stenosis with preserved ejection fraction is a controversial entity. Misclassification of valvulopathy severity could explain the inconsistencies reported in the prognosis of these patients. Planimetry of the aortic area using three-dimensional transesophageal echocardiography could clear up these doubts. The objectives were to assess the agreement between measurements of the valvular aortic area by continuity equation in transthoracic echocardiography and that obtained through planimetry with three-dimensional transesophageal echocardiography in low-gradient severe aortic stenosis patients. METHODS: Cross-sectional descriptive study of consecutive patients referred due to severe aortic stenosis. Patients underwent transthoracic echocardiography and three-dimensional transesophageal echocardiography. Paradoxical low-gradient severe aortic stenosis was defined by the presence in the transthoracic echocardiography of aortic valve area<1 cm(2), mean ventricular gradient<40 mmHg, and ejection fraction ≥ 50%. Concordance between the two techniques was evaluated. RESULTS: Of 212 consecutive severe aortic stenosis patients evaluated, 63 cases (29.7%) fulfilled the paradoxical low-gradient inclusion criteria. We obtained three-dimensional aortic valve planimetry in 61 (96.8%) of those patients. In 52 patients (85.2%), aortic valve area by transesophageal echocardiography was <1 cm(2). The intraclass correlation coefficient between the two methods was 0.505 (95% confidence interval, 0.290-0.671; P<.001). CONCLUSIONS: Paradoxical low-gradient severe aortic stenosis is an actual entity, confirmed in 85% of cases evaluated by three-dimensional transesophageal echocardiography.


Assuntos
Estenose da Valva Aórtica/classificação , Estenose da Valva Aórtica/fisiopatologia , Volume Sistólico , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Estudos Transversais , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
Arch. cardiol. Méx ; 82(3): 248-251, jul.-sept. 2012. tab
Artigo em Espanhol | LILACS | ID: lil-685340

RESUMO

La práctica común consiste en añadir tratamiento antiagregante a la terapia anticoagulante, en los pacientes con fibrilación auricular (FA) y patología vascular establecida. Sin embargo, la necesidad de combinar ambas estrategias es un tema controvertido actualmente.


Current recommendation is to add antiplatelet drug to oral anticoagulation in patients with atrial fibrillation (AF) and vascular disease. However, it is debatable to join both antithrombotic drugs in stable vascular disease.


Assuntos
Humanos , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Inibidores da Agregação Plaquetária/uso terapêutico , Doenças Vasculares/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...