1.
Ear Hear ; 23(5): 422-7, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12411775

RESUMO

OBJECTIVE: The objective of this study was to compare the results of two measures of hearing aid satisfaction, an indirect measure (Satisfaction with Amplification in Daily Living, SADL; Cox & Alexander, 1999) and a direct measure (an expanded version of the MarkeTrak-IV survey; Kochkin, 1996), in a group of elderly hearing aid wearers. DESIGN: A total of 43 elderly hearing aid wearers completed both satisfaction measures (order counterbalanced across wearers) after 1 mo of wearing 2-channel wide dynamic range compression (WDRC) in-the-canal (ITC) hearing aids. A correlational research design was employed. RESULTS: The elderly hearing aid wearers in this study yielded results on each measure of hearing aid satisfaction that were generally consistent with those found previously in larger groups of similar samples. The correlation between each measure of satisfaction (r = 0.75) was positive, moderately strong, and significant (p < 0.01) for the global scores of the SADL and MarkeTrak-IV scales. CONCLUSIONS: Although different approaches to the measurement of satisfaction were followed in the development of the SADL (indirect approach) and the MarkeTrak-IV (direct measurement) scales, similar results were obtained with each scale. The 15-item SADL instrument, however, is much shorter than the MarkeTrak-IV instrument and, as a result, is more efficient to administer clinically.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial/terapia , Satisfação Pessoal , Inquéritos e Questionários , Estimulação Acústica/instrumentação , Atividades Cotidianas , Idoso , Desenho de Equipamento , Humanos , Índice de Gravidade de Doença
2.
Ear Hear ; 23(5): 428-38, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12411776

RESUMO

OBJECTIVE: The objective of this study was to measure hearing aid satisfaction and usage for extended periods of time, up to 2 yr after hearing aid delivery, to determine whether longitudinal changes occur in the elderly for these outcome measures. DESIGN: A longitudinal study of hearing aid satisfaction and usage was performed in a group comprised of 134 elderly hearing aid wearers with these outcome measures obtained at 1, 6, and 12 mo postfit. A total of 49 of the original 134 elderly returned 2 yr after hearing aid delivery to complete the satisfaction and usage measures again. Multiple self-report measures of hearing aid satisfaction and hearing aid usage were obtained at each follow-up session. RESULTS: Most between-interval comparisons of the various measures of satisfaction and usage failed to reveal significant changes over time. However, some significant changes were observed in both satisfaction and usage. When such changes occurred, they were always in a direction that suggested a decrease in satisfaction or usage over time. Correlations across various postfit interval pairs were found to be positive, statistically significant, and moderate to strong in strength for all measures of satisfaction and usage. CONCLUSIONS: Although there were slight declines in hearing aid usage and satisfaction over time, measures of hearing aid satisfaction obtained at 1 mo postfit and of hearing aid usage obtained at 6 mo postfit are generally stable for up to 2 yr after hearing aid delivery.


Assuntos
Auxiliares de Audição/estatística & dados numéricos , Perda Auditiva Neurossensorial/terapia , Satisfação Pessoal , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo