Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 391(2): 587-97, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18404261

RESUMO

The European directive 2000/53/EC limits the use of Cr(VI) in vehicle manufacturing. Although a maximum of 2 g of Cr(VI) was authorised per vehicle for corrosion prevention coatings of key components, since July 2007 its use has been prohibited except for some particular applications. Therefore, the objective of this work was to develop direct analytical procedures for Cr(VI) determination in the different steel coatings used for screws. Instead of working directly with screws, the optimisation of the procedures was carried out with metallic plates homogeneously coated to improve the data comparability. Extraction of Cr(VI) from the metallic parts was performed by sonication. Two extraction solutions were tested: a direct water extraction solution used in standard protocols and an ammonium/ammonia buffer solution at pH 8.9. The extracts were further analysed for Cr speciation by high-performance liquid chromatography (HPLC) inductively coupled plasma (ICP) atomic emission spectrometry or HPLC ICP mass spectrometry depending on the concentration level. When possible, the coatings were also directly analysed by solid speciation techniques (X-ray photoelectron spectroscopy, XPS, and X-ray absorption near-edge structure, XANES) for validation of the results. Very good results between the different analytical approaches were obtained for the sample of coating made up of a heated paint containing Zn, Al and Cr when using the extracting buffer solution at pH 8.9. After a repeated four-step extraction procedure on the same portion test, taking into account the depth of the surface layer reached, good agreement with XPS and XANES results was obtained. In contrast, for the coatings composed of an alkaline Zn layer where Cr(VI) and Cr(III) are deposited, only the extraction procedure using water allowed the detection of Cr(VI). To elucidate the Cr(VI) reduction during extraction at pH 8.9, the reactivity of Cr(VI) towards different species of Zn generally present in the coatings (metallic Zn and zinc oxide) was studied. The results showed that metallic Zn rapidly reduces Cr(VI), whereas this reaction is less evident in the presence of zinc oxide. Water was then retained for coatings containing metallic Zn.


Assuntos
Carcinógenos Ambientais/análise , Cromo/análise , Pintura/análise , Cromatografia Líquida de Alta Pressão/métodos , Corrosão , Concentração de Íons de Hidrogênio , Indústrias , Soluções/análise , Sonicação , Espectrofotometria Atômica/métodos , Aço , Água/análise , Raios X , Zinco/análise , Óxido de Zinco/análise
2.
Anal Chim Acta ; 587(2): 170-9, 2007 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-17386770

RESUMO

Among the transuranic elements present in the environment, plutonium isotopes are mainly attached to particles, and therefore they present a great interest for the study and modelling of particle transport in the marine environment. Except in the close vicinity of industrial sources, plutonium concentration in marine sediments is very low (from 10(-4) ng kg(-1) for (241)Pu to 10 ng kg(-1) for (239)Pu), and therefore the measurement of (238)Pu, (239)Pu, (240)Pu, (241)Pu and (242)Pu in sediments at such concentration level requires the use of very sensitive techniques. Moreover, sediment matrix contains huge amounts of mineral species, uranium and organic substances that must be removed before the determination of plutonium isotopes. Hence, an efficient sample preparation step is necessary prior to analysis. Within this work, a chemical procedure for the extraction, purification and pre-concentration of plutonium from marine sediments prior to sector-field inductively coupled plasma mass spectrometry (SF-ICP-MS) analysis has been optimized. The analytical method developed yields a pre-concentrated solution of plutonium from which (238)U and (241)Am have been removed, and which is suitable for the direct and simultaneous measurement of (239)Pu, (240)Pu, (241)Pu and (242)Pu by SF-ICP-MS.


Assuntos
Sedimentos Geológicos/química , Espectrometria de Massas/métodos , Plutônio/análise , Plutônio/química , Cinza Radioativa/análise , Radioisótopos/química , Química/métodos , Cromatografia por Troca Iônica , Monitoramento Ambiental , Radioisótopos/análise
3.
Anal Bioanal Chem ; 377(4): 685-94, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12904954

RESUMO

A European directive was recently adopted limiting the use of hazardous substances such as Pb, Hg, Cd, and Cr(VI) in vehicle manufacturing. From July 2003 a maximum of 2 g Cr(VI) will be authorised per vehicle in corrosion-preventing coatings of key components. As no standardised procedures are available to check if produced vehicles are in agreement with this directive, the objective of this work was to develop analytical procedures for total chromium and Cr(VI) determination in these materials. The first step of this study was to optimise digestion procedures for total chromium determination in plastic and metallic materials by inductively coupled plasma mass spectrometry (ICP-MS). High resolution (HR) ICP-MS was used to examine the influence of polyatomic interferences on the detection of the (52)Cr(+) and (53)Cr(+) isotopes. If there was strong interference with m/ z 52 for plastic materials, it was possible to use quadrupole ICP-MS for m/ z 53 if digestions were performed with HNO(3)+H(2)O(2). This mixture was also necessary for digestion of chromium from metallic materials. Extraction procedures in alkaline medium (NH(4)(+)/NH(3) buffer solution at pH 8.9) assisted by sonication were developed for determining Cr(VI) in four different corrosion-preventing coatings by HPLC-ICP-MS. After optimisation and validation with the only solid reference material certified for its Cr(VI) content (BCR 545; welding dusts), the efficiency of this extraction procedure for screw coatings was compared with that described in the EN ISO 3613 standard generally used in routine laboratories. For coatings comprising zinc and aluminium passivated in depth with chromium oxides the extraction procedure developed herein enabled determination of higher Cr(VI) concentrations. This was also observed for the screw covered with a chromium passivant layer on zinc-nickel. For coating comprising a chromium passivant layer on alkaline zinc the standardized extraction procedure was more efficient. In the case of painted metallic plate, because of a reactive matrix towards Cr(VI), its extraction without degradation was difficult to perform.

4.
J Automat Chem ; 20(4): 99-108, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-18924826

RESUMO

This paper describes rapid, simple microwave-assisted leaching/ digestion procedures for total and mercury species determination in sediment samples and biomaterials. An open focused microwave system allowed the sample preparation time to be dramatically reduced to only 24 min when a power of 40-80 W was applied. Quantitative leaching of methylmercury from sediments by HNO(3) solution and complete dissolution of biomaterials by an alkaline solution, such as 25% TMAH solution, were obtained. Methylmercury compounds were kept intact without decomposition or losses by evaporation. Quantitative recoveries of total mercury were achieved with a two-step microwave attack using a combination of HNO(3) and H(2)0(2) solutions as extractant. The whole pretreatment procedure only takes 15 min, which can be further shortened by an automated robust operation with an open focused system. These analytical procedures were validated by the analysis of environmental certified reference materials. The results confirm that the open focused microwave technique is a promising tool for solid sample preparation in analytical and environmental chemistry.

5.
Environ Pollut ; 97(1-2): 161-8, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-15093390

RESUMO

The aim of this study was to assess thallium (Tl) uptake into the aerial parts of selected crop species grown on French soils with high Tl content of pedogeochemical origin (0.3-40 mg Tl kg(-1) on a dry wt (DW) basis). Husked wheat and maize grains contained less than 4 microg Tl kg(-1) DW, but rape shoots accumulated Tl with a shoot-soil partition coefficient (PC) > 1, and rape seeds had PC > 3. Tl content of rape seed reached 33 mg Tl kg(-1) DW and higher concentrations in soil corresponded to increased concentrations in rape seeds. It is argued that parent material of the soil and pedogenesis have a considerable effect on Tl accumulation in rape seeds. These results show enhanced phytoavailability of Tl of pedogeochemical origin and prompt questions on the potential for food chain contamination by Tl in rape cattle cakes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA