Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Res ; 182: 108984, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31830695

RESUMO

Glyphosate, the most widely used herbicide worldwide, targets the 5-enolpyruvylshikimate-3-phosphate synthase (EPSPS) enzyme in the shikimate pathway found in plants and some microorganisms. While the potential for glyphosate to induce a broad range of biological effects in exposed organisms has been demonstrated, the global molecular mechanisms of toxicity and potential effects in bacterial symbionts remain unclear, in particular for ecologically important marine species such as bivalve molluscs. Here, the effects of glyphosate (GLY), its degradation product aminomethylphosphonic acid (AMPA), and a mixture of both (MIX) on the mussel M. galloprovincialis were assessed in a controlled experiment. For the first time, next generation sequencing (RNA-seq and 16S rRNA amplicon sequencing) was used to evaluate such effects at the molecular level in both the host and its respective microbiota. The results suggest that the variable capacity of bacterial species to proliferate in the presence of these compounds and the impairment of host physiological homeostasis due to AMPA and GLY toxicity may cause significant perturbations to the digestive gland microbiota, as well as elicit the spread of potential opportunistic pathogens such as Vibrio spp.. The consequent host-immune system activation identified at the molecular and cellular level could be aimed at controlling changes occurring in the composition of symbiotic microbial communities. Overall, our data raise further concerns about the potential adverse effects of glyphosate and AMPA in marine species, suggesting that both the effects of direct toxicity and the ensuing changes occurring in the host-microbial community must be taken into consideration to determine the overall ecotoxicological hazard of these compounds.


Assuntos
Glicina/análogos & derivados , Herbicidas , Isoxazóis , Mytilus , Tetrazóis , Animais , Glicina/toxicidade , Herbicidas/toxicidade , Isoxazóis/toxicidade , Microbiota , RNA Ribossômico 16S , Tetrazóis/toxicidade , Glifosato
2.
J Healthc Qual Res ; 33(2): 75-81, 2018.
Artigo em Espanhol | MEDLINE | ID: mdl-29534933

RESUMO

OBJECTIVE: To analyse the use of complementary tests and their relationship with safety incidents in hospital emergency departments. METHODOLOGY: An analysis was performed on 935 patients seen in the 9 hospital emergency departments. The source of data used for the detection of incidents were: emergency department clinical record and reports, together with face-to-face observation in the department, plus a telephone survey of the patient or family member at one week after the care. Statistical tests used: The Student t test for quantitative variables, Chi squared test for qualitative variables, and the ANOVA test. RESULTS: A peripheral venous catheter was used in 397 patients (42.4% (95% CI; 39.3-45.5%)), with a variability with significant differences between hospitals (P<.01), with a range of use from 37% to 81.8%. It was also observed that in 23.4% (95% CI; 19.2-27.6%) of the cases, the catheter was not used after the first blood draw. Radiological tests were requested for 351 patients, 37.7% (95% CI; 34.6-40.8%), also with significant differences between hospitals (P<.01), ranging from 24.6 to 65, 1%. Incidents were detected in 95 (10.2%) patients (95% CI; 8.3-12.1%) in the all the study centres. A higher proportion of safety incidents have been observed in patients where peripheral venous catheter has been used (12.8%) than in those in whom they had not been used (8.5%) (P=.03), as well as in patients on whom an x-ray was requested (12.8%) compared to those who did not (8.64%) (P=.04). A longer stay was also observed in cases with an incident (mean 248.9minutes) than in those where there were none (mean 164.1minutes) (P<.001). No statistically significant differences were found in the other parameters studied. CONCLUSION: A relationship was observed between the use of a peripheral venous catheter (many of them without use) and radiological tests and the occurrence of safety incidents in the Emergency Departments.


Assuntos
Cateterismo Periférico/efeitos adversos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Erros Médicos/estatística & dados numéricos , Segurança do Paciente/estatística & dados numéricos , Radiografia/efeitos adversos , Adulto , Análise de Variância , Cateterismo Periférico/estatística & dados numéricos , Distribuição de Qui-Quadrado , Intervalos de Confiança , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia/estatística & dados numéricos , Espanha , Triagem/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...