Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Radiat Prot Dosimetry ; 191(1): 1-8, 2020 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-32984906

RESUMO

The aim of this work was to estimate patient's organ absorbed doses from pediatric helical head computed tomography (CT) examinations using the Size-Specific Dose Estimate (SSDE) methodology and to determine organ dose to SSDE conversion coefficients for clinical routine. Patient-specific organ and tissue absorbed doses from 139 Head CT scans performed in pediatric patients from 0 to 15 years old in a Public Hospital in Tunja, Colombia were estimated. The calculations were made through Monte Carlo simulations, based on patient-specific information, dosimetric CT quantities (CTDIvol, DLP) and age-specific computational human phantoms matched to patients on the basis of gender and size. SSDE showed to be a good quantity for estimate patient-specific organ doses from pediatric head CT examinations when appropriate phantom's attenuation-based size metrics are chosen to match for any patient size. Strong correlations between absorbed dose and SSDE were found for skin (R2 = 0.99), brain (R2 = 0.98) and eyes (R2 = 0.97), respectively. Besides, a good correlation between SSDE and absorbed dose to the red bone marrow (tissue extended outside the scan coverage) was observed (R2 = 0.94). SSDE-to-organ-dose conversion coefficients obtained in this study provide a practical way to estimate patient-specific organ head CT doses.


Assuntos
Cabeça , Radiometria , Adolescente , Criança , Pré-Escolar , Cabeça/diagnóstico por imagem , Humanos , Lactente , Recém-Nascido , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X
2.
Radiat Prot Dosimetry ; 187(1): 1-7, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31034554

RESUMO

Prostatic artery embolisation (PAE) is used to treat patients with benign prostatic hyperplasia and with lower urinary obstructive tract symptoms. It is an interventional procedure which uses fluoroscopy equipment and can result in exposure to high doses of radiation in patients and staff. We aimed to demonstrate the reduction of radiation doses received by staff during PAE by implementing an optimised protocol called Radiation Exposure Curtailment for Embolisation (RECiFE). This protocol was implemented in cooperation with the medical team and technical team using Siemens Combined Applications to Reduce Exposure (CARE) protocol. The results showed approximately 83% reduction in the radiation doses received by the main physician during PAE. Thus, by adjusting the acquisition parameters of the angiographic equipment and implementing the RECiFE protocol, it is possible to optimise the PAE procedure and reduce the staff radiation dose.


Assuntos
Embolização Terapêutica/efeitos adversos , Exposição Ocupacional/efeitos adversos , Imagens de Fantasmas , Hiperplasia Prostática/terapia , Exposição à Radiação/efeitos adversos , Proteção Radiológica/métodos , Radiografia Intervencionista/efeitos adversos , Brasil , Humanos , Masculino
3.
Radiat Prot Dosimetry ; 185(2): 196-200, 2019 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-30668847

RESUMO

The objective of this study was to assess the radiation doses received by anaesthetists from prostatic artery embolization (PAE) procedures. Ten PAE procedures conducted in a reference hospital in the city of Recife, Brazil were investigated. Occupational dosimetry was performed using thermoluminescent dosemeters which were located next to the eyes, close to the thyroid (over the shielding), on the thorax (under the apron), on the wrist and on the feet of the physician's body. The results showed that the anaesthetist's feet received the highest doses followed by the eyes and the hands. In some complex PAE procedures the doses received by anaesthetists on the lens of the eyes and the effective dose were higher than those received by the main operator due to the anaesthetist's close position to the patient's table and the use of oblique projections. The personal dose equivalent Hp(3) per procedure for the anaesthetist's right eyebrow ranged from 20.2 µSv to 568.3 µSv. This result shows that anaesthetists assisting PAE procedures can exceeds the annual eye lens dose limit of 20 mSv recommended by the ICRP with only one procedure per week if radiation protection measures are not implemented during procedures.


Assuntos
Anestesistas/estatística & dados numéricos , Exposição Ocupacional/efeitos adversos , Traumatismos Ocupacionais/prevenção & controle , Hiperplasia Prostática/radioterapia , Exposição à Radiação/efeitos adversos , Proteção Radiológica/normas , Brasil/epidemiologia , Embolização Terapêutica/métodos , Extremidades/efeitos da radiação , Humanos , Incidência , Cristalino/efeitos da radiação , Masculino , Traumatismos Ocupacionais/epidemiologia , Traumatismos Ocupacionais/etiologia , Roupa de Proteção/normas , Equipamentos de Proteção/normas , Doses de Radiação , Radiologia Intervencionista/métodos
4.
Radiat Prot Dosimetry ; 183(4): 521-527, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30272212

RESUMO

The aim of this article was to verify the performance of the Mirion InstadoseTM dosemeter under clinical conditions and to compare its response in typical X-ray fields used during interventional and cardiology procedures with the TLD-100, usually used for radiation dosimetry. It was also objective of this study to verify the feasibility of using the InstadoseTM dosemeter response at the chest level for estimation of occupational eye lens dose in cardiology and interventional radiology. Initially the response of the dosemeter was tested using continuous X-ray beams and the results showed that the Instadose dosemeter present a satisfactory behavior of the most important dosimetric properties based on the tests as described in the IEC 62387 standard. The measurements performed in clinical conditions showed that the InstadoseTM dosemeter response was comparable to that of TL dosemeters used in interventional radiology and cardiology procedures and there is a correlation between the eye lens doses and the chest doses measured with the InstadoseTM. Based on the results obtained, we recommend the use of the InstadoseTM dosemeter for purposes of occupational whole-body monitoring of medical staff in interventional radiology and cardiology procedures.


Assuntos
Cardiologia , Cristalino/efeitos da radiação , Exposição Ocupacional/análise , Dosímetros de Radiação/estatística & dados numéricos , Exposição à Radiação/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/métodos , Radiologia Intervencionista , Humanos , Cristalino/lesões , Corpo Clínico , Roupa de Proteção , Equipamentos de Proteção , Doses de Radiação , Exposição à Radiação/prevenção & controle , Proteção Radiológica/instrumentação
5.
J Radiol Prot ; 36(2): 246-54, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27025551

RESUMO

The aim of this study was to evaluate the radiation doses to patients and staff received from the first cases of prostatic artery embolization (PAE) conducted in a public hospital in Recife, Brazil. Five PAE procedures for 5 men diagnosed with benign prostatic hyperplasia were investigated. In order to characterize patient exposure, dosimetric quantities, such as the air kerma-area product (P KA), the cumulative air kerma at the interventional reference point (Ka,r), the number of images, etc, were registered. To evaluate the possibility for deterministic effects, the peak skin dose (PSD) was measured using radiochromic films. For evaluation of personal dose equivalent and effective dose to the medical staff, thermoluminescent dosemeters (TLD-100) were used. The effective dose was estimated using the double dosimetry alghoritm of von Boetticher. The results showed that the mean patient's PSD per procedure was 2674.2 mGy. With regard to the medical staff, the mean, minimum and maximum effective doses estimated per procedure were: 18 µSv, 12 µSv and 21 µSv respectively. High personal equivalent doses were found for the feet, hands and lens of the eye, due to the use of multiple left anterior oblique projections and the improper use of the suspended lead screen and the lead curtain during procedures.


Assuntos
Embolização Terapêutica , Próstata/irrigação sanguínea , Hiperplasia Prostática/terapia , Exposição à Radiação , Radiografia Intervencionista , Brasil , Humanos , Masculino , Exposição Ocupacional , Doses de Radiação , Proteção Radiológica , Radiometria , Pele/efeitos da radiação , Dosimetria Termoluminescente
6.
Radiat Prot Dosimetry ; 168(3): 401-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26084305

RESUMO

The use of endoscopic retrograde cholangiopancreatography (ERCP) in pregnant patients is not rare. Most studies on the safety and efficacy of these procedures report short- and long-term pregnancy outcomes and but not foetal absorbed doses. This investigation reports on an ERCP procedure for a 40-y-old woman who was 32-34 weeks pregnant. Thermoluminescent dosemeters (TLD 100) were used to measure doses received by the patient and the staff. Additionally, Monte Carlo calculations were performed using a 3D computational phantom representing a 9-month pregnant patient to estimate the foetal absorbed dose. The results show that the spleen of the mother received the largest absorbed dose of 12.18 mGy since it was closer to the source than other internal organs. For the foetus and uterus, the lowest absorbed dose was found to be 0.01 mGy to the foetal brain, while the largest absorbed dose was estimated to be 0.13 mGy to the placenta.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Feto/efeitos da radiação , Corpo Clínico Hospitalar , Exposição Ocupacional/análise , Imagens de Fantasmas , Esfinterotomia Endoscópica/métodos , Adulto , Feminino , Humanos , Método de Monte Carlo , Mães , Gravidez , Doses de Radiação , Proteção Radiológica
7.
J Radiol Prot ; 35(3): 629-47, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26270613

RESUMO

The aim of this study is to evaluate organ and tissue absorbed doses to patients undergoing hepatic chemoembolization procedures performed in two hospitals in the city of Recife, Brazil. Forty eight patients undergoing fifty hepatic chemoembolization procedures were investigated. For the 20 cases with PA projection only, organs and tissues dose to KAP conversion coefficients were calculated using the mesh-based anthropometric phantom series FASH and MASH coupled to the EGSnrc Monte Carlo code. Clinical, dosimetric and irradiations parameters were registered for all patients. The maximum organ absorbed doses found were 2.4 Gy, 0.85 Gy, 0.76 Gy and 0.44 Gy for skin, kidneys, adrenals and liver, respectively.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica , Neoplasias Hepáticas/terapia , Doses de Radiação , Radiografia Intervencionista , Glândulas Suprarrenais/efeitos da radiação , Adulto , Brasil , Feminino , Humanos , Rim/efeitos da radiação , Fígado/efeitos da radiação , Masculino , Método de Monte Carlo , Imagens de Fantasmas , Pele/efeitos da radiação
8.
Radiat Prot Dosimetry ; 165(1-4): 263-7, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25870436

RESUMO

The purpose of this study was to evaluate patient and medical staff absorbed doses received from transarterial chemoembolisation of hepatocellular carcinoma, which is the most common primary liver tumour worldwide. The study was performed in three hospitals in Recife, capital of the state of Pernambuco, located in the Brazilian Northeastern region. Two are public hospitals (A and B), and one is private (C). For each procedure, the number of images, irradiation parameters (kV, mA and fluoroscopy time), the air kerma-area product (PKA) and the cumulative air kerma (Ka,r) at the reference point were registered. The maximum skin dose (MSD) of the patient was estimated using radiochromic film. For the medical staff dosimetry, thermoluminescence dosemeters (TLD-100) were attached next to the eyes, close to the thyroid (above the shielding), on the thorax under the apron, on the wrist and on the feet. The effective dose to the staff was estimated using the algorithm of von Boetticher. The results showed that the mean value of the total PKA was 267.49, 403.83 and 479.74 Gy cm(2) for Hospitals A, B and C, respectively. With regard to the physicians, the average effective dose per procedure was 17 µSv, and the minimum and maximum values recorded were 1 and 41 µSy, respectively. The results showed that the feet received the highest doses followed by the hands and lens of the eye, since the physicians did not use leaded glasses and the equipment had no lead curtain.


Assuntos
Carcinoma Hepatocelular/radioterapia , Quimioembolização Terapêutica/métodos , Neoplasias Hepáticas/radioterapia , Exposição Ocupacional/prevenção & controle , Radiologia Intervencionista/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Ar , Algoritmos , Brasil , Calibragem , Dosimetria Fotográfica/métodos , Fluoroscopia/métodos , Humanos , Pessoa de Meia-Idade , Roupa de Proteção , Doses de Radiação , Exposição à Radiação , Radiometria , Pele/efeitos da radiação , Dosimetria Termoluminescente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...