Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Chimia (Aarau) ; 76(1-2): 52-59, 2022 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38069749

RESUMO

Sensitive gas analyses, in particular in industrial processes, are nowadays performed either via spectroscopy or using quadrupole mass spectrometers; the first method provides a fast but indirect measurement, whereas the second provides in situ measurements of only one species at a time. In this article, we present a novel time-of-flight residual gas analyzer (TOF-RGA) built by the Swiss company Spacetek Technology AG, and show the results of measurements such as the characterization of the FC5311 calibration compound, the detection of naturally abundant noble gases in air, the measurement of a noble gas mixture in the ultra-high vacuum facilities of CERN, and measurements acquired in a X-ray Photoelectron Spectroscopy facility in Germany, to demonstrate the capability of this new TOF-RGA to compete with already existing techniques for the monitoring of the composition of gases in real time (10 times per second), at high resolution (m/?m = 1 200 measured at m/z 132), and with a high sensitivity at ppb level.

2.
J Phys Chem A ; 123(27): 5805-5814, 2019 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-31257892

RESUMO

Recent high-resolution in situ mass spectrometry at comet 67P/Churyumov-Gerasimenko visited by European Space Agency's Rosetta spacecraft raised the question, if sublimating ammonium salts can unequivocally be detected in the cometary coma. In laboratory experiments with the twin model of the space instrument, two prototypic ammonium salts NH4B, namely, ammonium chloride (B = Cl-) and ammonium formate (B = HCOO-) (as well as methodologically relevant isotopologues), were allowed to sublimate in vacuum while mass spectra were collected. High-resolution electron-impact ionization mass spectrometry provides an outstanding experimental tool to investigate the complex physicochemical processes occurring during the sublimation of ammonium salts. Sublimation of ammonium chloride led to the observation of the ammonium cation NH4+ and the chloramide molecule NH2Cl in the neutral gas mode of the instrument. These observations could be jointly interpreted as indirect evidence for the existence of a neutral gaseous parent species (either as the molecular complex NH3···HB or the double-ionic species NH4+···B-). However, the qualitative fragmentation pattern we present for 13C15N-ammonium formate suggests an alternative route of NH4+ production within the ionization region of the instrument, namely, by protonation/hydrogenation. Besides NH4+, other species were observed that were formed in protonation/hydrogenation reactions. Moreover, together with the two major species from the decomposition of the salt, ammonia and formic acid, three minor species also contributed to the fragmentation pattern: HCN/HNC, HOCN/HNCO, and CH3NO. Like chloramide, formamide (CH3NO) also is a secondary species probably formed in a pseudo-intramolecular chemical reaction while ammonia and the respective acid are in a state of association. HCN/HNC and HOCN/HNCO are ternary products coming out of formamide decomposition reactions. We discuss our experimental findings, summarized in a tentative chemical reaction network, in light of the available theoretical literature and highlight their relevance for the interpretation of in situ measurements in space research.

3.
Sci Adv ; 4(7): eaar6297, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29978041

RESUMO

The Rosetta Orbiter Spectrometer for Ion and Neutral Analysis mass spectrometer Double Focusing Mass Spectrometer on board the European Space Agency's Rosetta spacecraft detected the major isotopes of the noble gases argon, krypton, and xenon in the coma of comet 67P/Churyumov-Gerasimenko. Earlier, it was found that xenon exhibits an isotopic composition distinct from anywhere else in the solar system. However, argon isotopes, within error, were shown to be consistent with solar isotope abundances. This discrepancy suggested an additional exotic component of xenon in comet 67P/Churyumov-Gerasimenko. We show that krypton also exhibits an isotopic composition close to solar. Furthermore, we found the argon to krypton and the krypton to xenon ratios in the comet to be lower than solar, which is a necessity to postulate an addition of exotic xenon in the comet.

4.
Sci Adv ; 2(5): e1600285, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27386550

RESUMO

The importance of comets for the origin of life on Earth has been advocated for many decades. Amino acids are key ingredients in chemistry, leading to life as we know it. Many primitive meteorites contain amino acids, and it is generally believed that these are formed by aqueous alterations. In the collector aerogel and foil samples of the Stardust mission after the flyby at comet Wild 2, the simplest form of amino acids, glycine, has been found together with precursor molecules methylamine and ethylamine. Because of contamination issues of the samples, a cometary origin was deduced from the (13)C isotopic signature. We report the presence of volatile glycine accompanied by methylamine and ethylamine in the coma of 67P/Churyumov-Gerasimenko measured by the ROSINA (Rosetta Orbiter Spectrometer for Ion and Neutral Analysis) mass spectrometer, confirming the Stardust results. Together with the detection of phosphorus and a multitude of organic molecules, this result demonstrates that comets could have played a crucial role in the emergence of life on Earth.


Assuntos
Aminoácidos/química , Meteoroides , Fósforo/química , Prebióticos/análise , Espectrometria de Massas/métodos
5.
Sci Adv ; 1(8): e1500377, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26601264

RESUMO

Comets have been considered to be representative of icy planetesimals that may have contributed a significant fraction of the volatile inventory of the terrestrial planets. For example, comets must have brought some water to Earth. However, the magnitude of their contribution is still debated. We report the detection of argon and its relation to the water abundance in the Jupiter family comet 67P/Churyumov-Gerasimenko by in situ measurement of the Rosetta Orbiter Spectrometer for Ion and Neutral Analysis (ROSINA) mass spectrometer aboard the Rosetta spacecraft. Despite the very low intensity of the signal, argon is clearly identified by the exact determination of the mass of the isotope (36)Ar and by the (36)Ar/(38)Ar ratio. Because of time variability and spatial heterogeneity of the coma, only a range of the relative abundance of argon to water can be given. Nevertheless, this range confirms that comets of the type 67P/Churyumov-Gerasimenko cannot be the major source of Earth's major volatiles.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...