Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Nat Commun ; 10(1): 4673, 2019 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-31611594

RESUMO

Advances in precision molecular imaging promise to transform our ability to detect, diagnose and treat disease. Here, we describe the engineering and validation of a new cystine knot peptide (knottin) that selectively recognizes human integrin αvß6 with single-digit nanomolar affinity. We solve its 3D structure by NMR and x-ray crystallography and validate leads with 3 different radiolabels in pre-clinical models of cancer. We evaluate the lead tracer's safety, biodistribution and pharmacokinetics in healthy human volunteers, and show its ability to detect multiple cancers (pancreatic, cervical and lung) in patients at two study locations. Additionally, we demonstrate that the knottin PET tracers can also detect fibrotic lung disease in idiopathic pulmonary fibrosis patients. Our results indicate that these cystine knot PET tracers may have potential utility in multiple disease states that are associated with upregulation of integrin αvß6.


Assuntos
Antígenos de Neoplasias/metabolismo , Fibrose Pulmonar Idiopática/diagnóstico , Integrinas/metabolismo , Neoplasias/diagnóstico , Cristalografia por Raios X , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons
2.
Nano Lett ; 17(11): 6644-6652, 2017 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-28990786

RESUMO

Each immunoglobulin isotype has unique immune effector functions. The contribution of these functions in the elimination of pathogens and tumors can be determined by monitoring quantitative temporal changes in isotype levels. Here, we developed a novel technique using magneto-nanosensors based on the effect of giant magnetoresistance (GMR) for longitudinal monitoring of total and antigen-specific isotype levels with high precision, using as little as 1 nL of serum. Combining in vitro serologic measurements with in vivo imaging techniques, we investigated the role of the antibody response in the regression of firefly luciferase (FL)-labeled lymphoma cells in spleen, kidney, and lymph nodes in a syngeneic Burkitt's lymphoma mouse model. Regression status was determined by whole body bioluminescent imaging (BLI). The magneto-nanosensors revealed that anti-FL IgG2a and total IgG2a were elevated and sustained in regression mice compared to non-regression mice (p < 0.05). This platform shows promise for monitoring immunotherapy, vaccination, and autoimmunity.


Assuntos
Formação de Anticorpos , Técnicas Biossensoriais/instrumentação , Linfoma de Burkitt/imunologia , Imunoglobulina G/análise , Magnetismo/instrumentação , Animais , Linfoma de Burkitt/sangue , Linfoma de Burkitt/diagnóstico por imagem , Desenho de Equipamento , Feminino , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Medições Luminescentes/métodos , Camundongos , Camundongos Endogâmicos C57BL , Imagem Óptica/instrumentação , Tamanho da Amostra
3.
Nat Commun ; 7: 12220, 2016 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-27447090

RESUMO

Substantial efforts have been made to understand the interactions between immune checkpoint receptors and their ligands targeted in immunotherapies against cancer. To carefully characterize the complete network of interactions involved and the binding affinities between their extracellular domains, an improved kinetic assay is needed to overcome limitations with surface plasmon resonance (SPR). Here, we present a magneto-nanosensor platform integrated with a microfluidic chip that allows measurement of dissociation constants in the micromolar-range. High-density conjugation of magnetic nanoparticles with prey proteins allows multivalent receptor interactions with sensor-immobilized bait proteins, more closely mimicking natural-receptor clustering on cells. The platform has advantages over traditional SPR in terms of insensitivity of signal responses to pH and salinity, less consumption of proteins and better sensitivities. Using this platform, we characterized the binding affinities of the PD-1-PD-L1/PD-L2 co-inhibitory receptor system, and discovered an unexpected interaction between the two known PD-1 ligands, PD-L1 and PD-L2.


Assuntos
Antígeno B7-H1/metabolismo , Magnetismo/métodos , Nanopartículas/química , Proteína 2 Ligante de Morte Celular Programada 1/metabolismo , Mapeamento de Interação de Proteínas , Sistemas Computacionais , Humanos , Concentração de Íons de Hidrogênio , Cinética , Ligação Proteica , Salinidade
4.
Plast Reconstr Surg ; 137(5): 890e-897e, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27119951

RESUMO

Medical decision-making is increasingly based on quantifiable data. From the moment patients come into contact with the health care system, their entire medical history is recorded electronically. Whether a patient is in the operating room or on the hospital ward, technological advancement has facilitated the expedient and reliable measurement of clinically relevant health metrics, all in an effort to guide care and ensure the best possible clinical outcomes. However, as the volume and complexity of biomedical data grow, it becomes challenging to effectively process "big data" using conventional techniques. Physicians and scientists must be prepared to look beyond classic methods of data processing to extract clinically relevant information. The purpose of this article is to introduce the modern plastic surgeon to machine learning and computational interpretation of large data sets. What is machine learning? Machine learning, a subfield of artificial intelligence, can address clinically relevant problems in several domains of plastic surgery, including burn surgery; microsurgery; and craniofacial, peripheral nerve, and aesthetic surgery. This article provides a brief introduction to current research and suggests future projects that will allow plastic surgeons to explore this new frontier of surgical science.


Assuntos
Tomada de Decisão Clínica , Aprendizado de Máquina , Destreza Motora , Procedimentos de Cirurgia Plástica/métodos , Cirurgia Plástica/métodos , Queimaduras/cirurgia , Competência Clínica/normas , Craniossinostoses/diagnóstico , Craniossinostoses/cirurgia , Conjuntos de Dados como Assunto , Mãos/cirurgia , Humanos , Internato e Residência/normas , Microcirurgia/métodos , Nervos Periféricos/cirurgia , Procedimentos de Cirurgia Plástica/educação , Cirurgia Plástica/educação , Ensino
5.
Lab Chip ; 15(22): 4273-6, 2015 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-26395039

RESUMO

We demonstrate microfluidic partitioning of a giant magnetoresistive sensor array into individually addressable compartments that enhances its effective use. Using different samples and reagents in each compartment enables measuring of cross-reactive species and wide dynamic ranges on a single chip. This compartmentalization technique motivates the employment of high density sensor arrays for highly parallelized measurements in lab-on-a-chip devices.


Assuntos
Campos Magnéticos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Técnicas Biossensoriais/instrumentação , Imunoensaio/instrumentação , Dispositivos Lab-On-A-Chip , Proteínas/análise
6.
BMJ Case Rep ; 20142014 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-25123567

RESUMO

We report a case of a 72-year-old man who presented with a persistent pleural effusion and painful abscess in the right lower chest wall 6 months following a laparoscopic cholecystectomy. The patient subsequently developed a chronic cutaneous chest wall fistula requiring a large resection and complex closure. The complication was likely secondary to intraoperative spillage of gallstones. While previous reports describe gallstone spillage in the abdominal cavity as benign, this case illustrates that stones left in the abdominal cavity can potentially lead to significant morbidity. Therefore, stones should be diligently removed from the abdominal cavity when spillage occurs. In addition, it is important that operative notes reflect the occurrence of stone spillage so stones may be suspected when a patient presents with an abdominal or thoracic infection following a cholecystectomy.


Assuntos
Colecistite/etiologia , Fístula Cutânea/etiologia , Cálculos Biliares/complicações , Parede Torácica , Idoso , Colecistectomia Laparoscópica/métodos , Colecistite/diagnóstico , Colecistite/cirurgia , Doença Crônica , Fístula Cutânea/diagnóstico , Fístula Cutânea/cirurgia , Diagnóstico Diferencial , Fístula/diagnóstico , Fístula/etiologia , Fístula/cirurgia , Cálculos Biliares/diagnóstico , Cálculos Biliares/cirurgia , Humanos , Masculino , Procedimentos de Cirurgia Plástica/métodos , Retalhos Cirúrgicos , Tomografia Computadorizada por Raios X
7.
Lab Chip ; 14(1): 78-88, 2014 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-23969419

RESUMO

Detection and characterization of circulating tumor cells (CTCs) may reveal insights into the diagnosis and treatment of malignant disease. Technologies for isolating CTCs developed thus far suffer from one or more limitations, such as low throughput, inability to release captured cells, and reliance on expensive instrumentation for enrichment or subsequent characterization. We report a continuing development of a magnetic separation device, the magnetic sifter, which is a miniature microfluidic chip with a dense array of magnetic pores. It offers high efficiency capture of tumor cells, labeled with magnetic nanoparticles, from whole blood with high throughput and efficient release of captured cells. For subsequent characterization of CTCs, an assay, using a protein chip with giant magnetoresistive nanosensors, has been implemented for mutational analysis of CTCs enriched with the magnetic sifter. The use of these magnetic technologies, which are separate devices, may lead the way to routine preparation and characterization of "liquid biopsies" from cancer patients.


Assuntos
Separação Celular/métodos , Magnetismo , Técnicas Analíticas Microfluídicas/métodos , Células Neoplásicas Circulantes/metabolismo , Anticorpos Imobilizados/química , Anticorpos Imobilizados/imunologia , Antígenos de Neoplasias/imunologia , Antígenos de Neoplasias/metabolismo , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Carcinoma Pulmonar de Células não Pequenas/patologia , Moléculas de Adesão Celular/imunologia , Moléculas de Adesão Celular/metabolismo , Linhagem Celular Tumoral , Separação Celular/instrumentação , Molécula de Adesão da Célula Epitelial , Receptores ErbB/genética , Receptores ErbB/imunologia , Receptores ErbB/metabolismo , Fluoresceína-5-Isotiocianato/química , Humanos , Queratinas/imunologia , Queratinas/metabolismo , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/patologia , Células MCF-7 , Nanopartículas de Magnetita/química , Técnicas Analíticas Microfluídicas/instrumentação , Mutação
8.
Sci Rep ; 3: 2234, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23868657

RESUMO

Giant magnetoresistive (GMR) nanosensors provide a novel approach for measuring protein concentrations in blood for medical diagnosis. Using an in vivo mouse radiation model, we developed protocols for measuring Flt3 ligand (Flt3lg) and serum amyloid A1 (Saa1) in small amounts of blood collected during the first week after X-ray exposures of sham, 0.1, 1, 2, 3, or 6 Gy. Flt3lg concentrations showed excellent dose discrimination at ≥ 1 Gy in the time window of 1 to 7 days after exposure except 1 Gy at day 7. Saa1 dose response was limited to the first two days after exposure. A multiplex assay with both proteins showed improved dose classification accuracy. Our magneto-nanosensor assay demonstrates the dose and time responses, low-dose sensitivity, small volume requirements, and rapid speed that have important advantages in radiation triage biodosimetry.


Assuntos
Técnicas Biossensoriais , Proteínas Sanguíneas , Nanotecnologia , Radiação Ionizante , Radiometria , Animais , Biomarcadores/sangue , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/normas , Relação Dose-Resposta à Radiação , Feminino , Masculino , Proteínas de Membrana/sangue , Camundongos , Reprodutibilidade dos Testes , Proteína Amiloide A Sérica , Fatores de Tempo
9.
Ann Plast Surg ; 70(4): 442-6, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23486125

RESUMO

Surgical competency requires the development of decision-making and technical skills. Despite lectures, literature, and written and oral examinations, both skill sets are difficult to systematically teach and analyze. With the advent of head-mounted video cameras, we seek to incorporate a surgical video database into our surgical training curriculum. We hope to not only change the way and rate at which surgical trainees develop their surgical skills but to also introduce a novel tool for surgical skill assessment.


Assuntos
Competência Clínica , Internato e Residência , Cirurgia Plástica/educação , Gravação em Vídeo/instrumentação , Desenho de Equipamento , Internato e Residência/métodos , Gravação em Vídeo/economia
10.
Ann Plast Surg ; 70(4): 447-53, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23486129

RESUMO

BACKGROUND: This study seeks to determine human host response to fetal bovine acellular dermal matrix (ADM) in staged implant-based breast reconstruction. METHODS: A prospective study was performed for patients undergoing immediate breast reconstruction with tissue expander placement and SurgiMend acellular fetal bovine dermis. At the time of exchange for permanent implant, we obtained tissue specimens of SurgiMend and native capsule. Histological and immunohistochemical assays were performed to characterize the extent of ADM incorporation/degradation, host cell infiltration, neovascularization, inflammation, and host replacement of acellular fetal bovine collagen. RESULTS: Seventeen capsules from 12 patients were included in our study. The average "implantation" time of SurgiMend was 7.8 months (range, 2-23 months). Histological analysis of the biopsy of tissue revealed rare infiltration of host inflammatory cells, even at 23 months. One patient had an infection requiring removal of the tissue expander at 2 months. Contracture, inflammatory changes, edema, and polymorphonuclear leukocyte infiltration were rare in the ADM. An acellular capsule was seen in many cases, at the interface of SurgiMend with the tissue expander. CONCLUSIONS: SurgiMend demonstrated a very infrequent inflammatory response. An antibody specific to bovine collagen allowed for direct identification of bovine collagen separate from human collagen. Cellular infiltration and neovascularization of SurgiMend correlated with the quality of the mastectomy skin flap rather than the duration of implantation. Future studies are needed to further characterize the molecular mechanisms underlying tissue incorporation of this product.


Assuntos
Derme Acelular , Implante Mamário , Implantes de Mama , Dispositivos para Expansão de Tecidos , Adulto , Animais , Implante Mamário/métodos , Bovinos , Feminino , Feto , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
11.
Expert Rev Proteomics ; 10(1): 65-75, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23414360

RESUMO

Numerous efforts have been made to understand fundamental biology of diseases based on gene expression. However, the relationship between gene expression and onset of disease often remains obscure. The great advances in protein microarrays allow us to investigate this unclear question through protein profiles, which are regarded as more reliable than gene expressions to serve as the harbinger of disease onset or as the biomarker of disease treatment monitoring. The authors review two relatively new platforms of protein arrays, along with an introduction to the common basis of protein array technologies. Immobilization of proteins on the surface of arrays and neutralizing reactive areas after the immobilization are key practical issues in the field of protein array. One of the emerging protein array technologies is the magneto-nanosensor array, where giant magnetoresistive sensors are used to quantitatively measure the analytes of interest, which are labeled with magnetic nanoparticles. Similar to giant magnetoresistive sensors, several different ways of utilizing magnetic properties for biomolecular detection have been developed and are reviewed here. Another emerging protein array technology is nucleic acid programmable protein arrays, which have thousands of protein features directly expressed by nucleic acids on the array surface. The authors anticipate that these two emerging protein array platforms can be combined to produce synergistic benefits and open new applications in proteomics and clinical diagnostics.


Assuntos
Análise Serial de Proteínas/métodos , Proteômica/métodos , Animais , Humanos , Imãs , Nanotecnologia , Análise de Sequência com Séries de Oligonucleotídeos/métodos
12.
IEEE J Solid-State Circuits ; 48(5): 1290-1301, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-24761029

RESUMO

Magnetic nanotechnologies have shown significant potential in several areas of nanomedicine such as imaging, therapeutics, and early disease detection. Giant magnetoresistive spin-valve (GMR SV) sensors coupled with magnetic nanotags (MNTs) possess great promise as ultra-sensitive biosensors for diagnostics. We report an integrated sensor interface for an array of 256 GMR SV biosensors designed in 0.18 µm CMOS. Arranged like an imager, each of the 16 column level readout channels contains an analog front- end and a compact ΣΔ modulator (0.054 mm2) with 84 dB of dynamic range and an input referred noise of 49 nT/√Hz. Performance is demonstrated through detection of an ovarian cancer biomarker, secretory leukocyte peptidase inhibitor (SLPI), spiked at concentrations as low as 10 fM. This system is designed as a replacement for optical protein microarrays while also providing real-time kinetics monitoring.

13.
Microsurgery ; 32(5): 388-92, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22473859

RESUMO

Despite significant advances in reconstructive surgery, the repair of massive lumbosacral defects poses significant challenges. When the extent of soft tissue loss, tumor resection, and/or radiation therapy preclude the use of traditional local options, such as gluteal advancement flaps or pedicled thigh flaps, then distant flaps are required. We report a case of a 64-year-old male who presented with a large sacral Marjolin's ulcer secondary to recurrent pilonidal cysts and ulcerations. The patient underwent wide local composite resection, which resulted in a wound measuring 450 cm(2) with exposed rectum and sacrum. The massive defect was successfully covered with a free transverse rectus abdominis myocutaneous flap, providing a well-vascularized skin paddle and obviating the need for a latissimus flap with skin graft. The free-TRAM flap proved to be a very robust flap in this situation and would be one of our flaps of choice for similar defects.


Assuntos
Carcinoma de Células Escamosas/cirurgia , Retalhos de Tecido Biológico , Seio Pilonidal/complicações , Procedimentos de Cirurgia Plástica/métodos , Reto do Abdome/transplante , Neoplasias Cutâneas/cirurgia , Nádegas/irrigação sanguínea , Carcinoma de Células Escamosas/etiologia , Humanos , Região Lombossacral , Masculino , Pessoa de Meia-Idade , Neoplasias Cutâneas/etiologia
14.
Nat Nanotechnol ; 6(5): 314-20, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21478869

RESUMO

Monitoring the kinetics of protein interactions on a high-density sensor array is vital to drug development and proteomic analysis. Label-free kinetic assays based on surface plasmon resonance are the current gold standard, but they have poor detection limits, suffer from non-specific binding, and are not amenable to high-throughput analyses. Here, we show that magnetically responsive nanosensors that have been scaled to over 100,000 sensors per cm² can be used to measure the binding kinetics of various proteins with high spatial and temporal resolution. We present an analytical model that describes the binding of magnetically labelled antibodies to proteins that are immobilized on the sensor surface. This model is able to quantify the kinetics of antibody-antigen binding at sensitivities as low as 20 zeptomoles of solute.


Assuntos
Técnicas Biossensoriais/instrumentação , Nanopartículas de Magnetita/química , Análise Serial de Proteínas/instrumentação , Reações Antígeno-Anticorpo , Antígenos de Neoplasias/análise , Antígeno Carcinoembrionário/análise , Moléculas de Adesão Celular/análise , Molécula de Adesão da Célula Epitelial , Cinética , Modelos Moleculares , Ligação Proteica , Proteínas/química , Sensibilidade e Especificidade , Ressonância de Plasmônio de Superfície/métodos , Fator A de Crescimento do Endotélio Vascular/análise
15.
Lab Chip ; 11(5): 950-6, 2011 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-21264375

RESUMO

Driven by scientific progress and economic stimulus, medical diagnostics will move to a stage in which straightforward medical diagnoses are independent of physician visits and large centralized laboratories. The future of basic diagnostic medicine will lie in the hands of private individuals. We have taken significant strides towards achieving this goal by developing an autoassembly assay for disease biomarker detection which obviates the need for washing steps and is run on a handheld sensing platform. By coupling magnetic nanotechnology with an array of magnetically responsive nanosensors, we demonstrate a rapid, multiplex immunoassay that eliminates the need for trained technicians to run molecular diagnostic tests. Furthermore, the platform is battery-powered and ultraportable, allowing the assay to be run anywhere in the world by any individual.


Assuntos
Técnicas de Laboratório Clínico/instrumentação , Saúde , Internacionalidade , Nanotecnologia/instrumentação , Técnicas Biossensoriais , Países em Desenvolvimento , Proteína do Núcleo p24 do HIV/análise , Imunoensaio , Magnetismo , Vírus/isolamento & purificação
16.
Nano Lett ; 11(7): 2579-83, 2011 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-20804215

RESUMO

We report an autoassembly protein array capable of rapidly screening for aberrant antibody-antigen binding events. Our technique combines magnetic nanoparticle technology with proximity-based, magnetically responsive nanosensors for rapid (under 15 min) and high-density screening of antibody cross-reactivity at sensitivities down to 50 fM in a homogeneous assay. This method will enable the identification of the precise cause of aberrant or cross-reactive binding events in an easy-to-use, rapid, and high-throughput manner.


Assuntos
Anticorpos/análise , Anticorpos/imunologia , Reações Cruzadas/imunologia , Nanotecnologia , Análise Serial de Proteínas , Reações Antígeno-Anticorpo , Ensaios de Triagem em Larga Escala , Imunoensaio , Magnetismo
17.
Conf Proc (Midwest Symp Circuits Syst) ; : 1779-1782, 2010 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-22495252

RESUMO

This paper presents a hand-held, portable biosensor platform for quantitative biomarker measurement. By combining magnetic nanoparticle (MNP) tags with giant magnetoresistive (GMR) spin-valve sensors, the hand-held platform achieves highly sensitive (picomolar) and specific biomarker detection in less than 20 minutes. The rapid analysis and potential low cost make this technology ideal for point-of-care (POC) diagnostics. Furthermore, this platform is able to detect multiple biomarkers simultaneously in a single assay, creating a promising diagnostic tool for a vast number of applications.

18.
Nat Med ; 15(11): 1327-32, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19820717

RESUMO

Advances in biosensor technologies for in vitro diagnostics have the potential to transform the practice of medicine. Despite considerable work in the biosensor field, there is still no general sensing platform that can be ubiquitously applied to detect the constellation of biomolecules in diverse clinical samples (for example, serum, urine, cell lysates or saliva) with high sensitivity and large linear dynamic range. A major limitation confounding other technologies is signal distortion that occurs in various matrices due to heterogeneity in ionic strength, pH, temperature and autofluorescence. Here we present a magnetic nanosensor technology that is matrix insensitive yet still capable of rapid, multiplex protein detection with resolution down to attomolar concentrations and extensive linear dynamic range. The matrix insensitivity of our platform to various media demonstrates that our magnetic nanosensor technology can be directly applied to a variety of settings such as molecular biology, clinical diagnostics and biodefense.


Assuntos
Bioensaio , Técnicas Biossensoriais/instrumentação , Proteínas/metabolismo , Animais , Técnicas Biossensoriais/métodos , Antígeno Carcinoembrionário/metabolismo , Modelos Animais de Doenças , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Concentração de Íons de Hidrogênio , Espectroscopia de Ressonância Magnética/métodos , Camundongos , Nanotecnologia/instrumentação , Nanotecnologia/métodos , Óptica e Fotônica/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura , Fatores de Tempo , Fator A de Crescimento do Endotélio Vascular/metabolismo , Ensaios Antitumorais Modelo de Xenoenxerto/instrumentação , Ensaios Antitumorais Modelo de Xenoenxerto/métodos
19.
J Magn Magn Mater ; 321(10): 1452-1458, 2009 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-20161001

RESUMO

Optical observations of 100 nm metallic magnetic nanoparticles are used to study their magnetic field induced self assembly. Chains with lengths of tens of microns are observed to form within minutes at nanoparticle concentrations of 10(10) per mL. Chain rotation and magnetophoresis are readily observed, and SEM reveals that long chains are not simple single particle filaments. Similar chains are detected for several 100 nm commercial bio-separation nanoparticles. We demonstrate the staged magnetic condensation of different types of nanoparticles into composite structures and show that magnetic chains bind to immunomagnetically labeled cells, serving as temporary handles which allow novel magnetic cell manipulations.

20.
Proc Natl Acad Sci U S A ; 105(52): 20637-40, 2008 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-19074273

RESUMO

Magnetic nanotags (MNTs) are a promising alternative to fluorescent labels in biomolecular detection assays, because minute quantities of MNTs can be detected with inexpensive giant magnetoresistive (GMR) sensors, such as spin valve (SV) sensors. However, translating this promise into easy to use and multilplexed protein assays, which are highly sought after in molecular diagnostics such as cancer diagnosis and treatment monitoring, has been challenging. Here, we demonstrate multiplex protein detection of potential cancer markers at subpicomolar concentration levels and with a dynamic range of more than four decades. With the addition of nanotag amplification, the analytic sensitivity extends into the low fM concentration range. The multianalyte ability, sensitivity, scalability, and ease of use of the MNT-based protein assay technology make it a strong contender for versatile and portable molecular diagnostics in both research and clinical settings.


Assuntos
Bioensaio/métodos , Biomarcadores Tumorais/análise , Técnicas de Diagnóstico Molecular/métodos , Nanotecnologia/métodos , Bioensaio/instrumentação , Humanos , Magnetismo/instrumentação , Magnetismo/métodos , Técnicas de Diagnóstico Molecular/instrumentação , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Nanotecnologia/instrumentação , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...