Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Anaesthesist ; 56(8): 790-2, 2007 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-17541522

RESUMO

Following cardiac arrest a 41-year-old patient was resuscitated for 40 min and required mechanical ventilation for 27.5 h. Acute shortness of breath and inspiratory stridor developed 7 days after successful extubation. Bronchoscopy revealed a subtotal tracheal stenosis caused by extensive fibrinous membranes. Local ischaemia caused by cuff pressure seems to be a likely explanation with an additional component of general hypoperfusion and haemodynamic instability which led to gastric bleeding (classification according to Forrest IIc) from ischaemic ulcers.


Assuntos
Reanimação Cardiopulmonar , Respiração Artificial/efeitos adversos , Estenose Traqueal/etiologia , Doença Aguda , Adulto , Pressão Sanguínea/fisiologia , Broncoscopia , Eletrocardiografia , Fibrose/patologia , Hemorragia Gastrointestinal/etiologia , Glote/patologia , Humanos , Masculino , Sons Respiratórios/etiologia , Estenose Traqueal/complicações , Estenose Traqueal/patologia
3.
Diabetes Care ; 10(3): 348-51, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-3297580

RESUMO

In search of possible interactions between plastic tubings used for insulin-pump treatment and commercial regular insulin preparations, various catheter sets made from polyvinyl chloride (PVC), polyethylene (PE), and nylon plastics were perfused at 30 degrees C in a laboratory setting for up to 72 h. The perfused insulin solutions were analyzed by high-performance liquid chromatography and atomic absorption spectroscopy. Although no plasticizer, e.g., dioctyl phthalate, or nickel or chromium ions were found in the perfusates, substantial interactions between the plastics and the insulin solutions were detected, extraction of bacteriostatic additives from the insulin solutions in particular. The PVC retained up to 88% of the bacteriostatics from the insulin preparations, whereas PE tubings retained only 10-15%. Whether the loss of preservatives during perfusion through PVC catheters predisposes to cutaneous infections during insulin-pump therapy remains to be shown.


Assuntos
Cateterismo/instrumentação , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Contaminação de Medicamentos , Incompatibilidade de Medicamentos , Estabilidade de Medicamentos , Insulina/análise , Nylons , Plastificantes , Polietilenos , Cloreto de Polivinila , Conservantes Farmacêuticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...