1.
Sci Rep ; 11(1): 7780, 2021 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-33833288

RESUMO

Quantitative Doppler ultrasound of the carotid artery has been proposed as an instantaneous surrogate for monitoring rapid changes in left ventricular output. Tracking immediate changes in the arterial Doppler spectrogram has value in acute care settings such as the emergency department, operating room and critical care units. We report a novel, hands-free, continuous-wave Doppler ultrasound patch that adheres to the neck and tracks Doppler blood flow metrics in the common carotid artery using an automated algorithm. String and blood-mimicking test objects demonstrated that changes in velocity were accurately measured using both manually and automatically traced Doppler velocity waveforms. In a small usability study with 22 volunteer users (17 clinical, 5 lay), all users were able to locate the carotid Doppler signal on a volunteer subject, and, in a subsequent survey, agreed that the device was easy to use. To illustrate potential clinical applications of the device, the Doppler ultrasound patch was used on a healthy volunteer undergoing a passive leg raise (PLR) as well as on a congestive heart failure patient at resting baseline. The wearable carotid Doppler patch holds promise because of its ease-of-use, velocity measurement accuracy, and ability to continuously record Doppler spectrograms over many cardiac and respiratory cycles.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Unidades de Terapia Intensiva , Testes Imediatos , Ultrassonografia Doppler/instrumentação , Adulto , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudo de Prova de Conceito
2.
Front Neurosci ; 11: 659, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29230164

RESUMO

Wireless neural stimulators are being developed to address problems associated with traditional lead-based implants. However, designing wireless stimulators on the sub-millimeter scale (<1 mm3) is challenging. As device size shrinks, it becomes difficult to deliver sufficient wireless power to operate the device. Here, we present a sub-millimeter, inductively powered neural stimulator consisting only of a coil to receive power, a capacitor to tune the resonant frequency of the receiver, and a diode to rectify the radio-frequency signal to produce neural excitation. By replacing any complex receiver circuitry with a simple rectifier, we have reduced the required voltage levels that are needed to operate the device from 0.5 to 1 V (e.g., for CMOS) to ~0.25-0.5 V. This reduced voltage allows the use of smaller receive antennas for power, resulting in a device volume of 0.3-0.5 mm3. The device was encapsulated in epoxy, and successfully passed accelerated lifetime tests in 80°C saline for 2 weeks. We demonstrate a basic proof-of-concept using stimulation with tens of microamps of current delivered to the sciatic nerve in rat to produce a motor response.

3.
IEEE Trans Biomed Eng ; 62(1): 323-30, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25181288

RESUMO

Electrocardiogram (ECG) monitoring is a critical tool in patient care, but its utility is often balanced with frustration from clinicians who are constantly distracted by false alarms. This has motivated the need to readdress the major factors that contribute to ECG noise with the goal of reducing false alarms. In this study, we describe a previously unreported phenomenon in which ECG noise can result from an unintended interaction between two systems: 1) the dc lead-off circuitry that is used to detect whether electrodes fall off the patient; and 2) the right-leg drive (RLD) system that is responsible for reducing ac common-mode noise that couples into the body. Using a circuit model to study this interaction, we found that in the presence of a dc lead-off system, even moderate increases in the right-leg skin-electrode resistance can cause the RLD amplifier to saturate. Such saturation can produce ECG noise because the RLD amplifier will no longer be capable of attenuating ac common-mode noise on the body. RLD saturation is particularly a problem for modern ECG monitors that use low-voltage supply levels. For example, for a 12-lead ECG and a 2 V power supply, saturation will occur when the right-leg electrode resistance reaches only 2 MΩ. We discuss several design solutions that can be used in low-voltage monitors to avoid RLD saturation.


Assuntos
Artefatos , Alarmes Clínicos , Eletrocardiografia/instrumentação , Eletrodos , Fenômenos Fisiológicos da Pele , Interface Usuário-Computador , Animais , Simulação por Computador , Desenho Assistido por Computador , Apresentação de Dados , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Modelos Biológicos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído