Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Comput Assist Tomogr ; 38(1): 96-104, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24424559

RESUMO

OBJECTIVE: To qualitatively and quantitatively assess the presentation of hepatic focal nodular hyperplasia (FNH) at diffusion-weighted magnetic resonance imaging (DWMRI) using multiple high b values. MATERIALS AND METHODS: Twenty-five patients with 27 FNHs had liver DWMRI at 1.5 T using free-breathing acquisition and 3 b values (0, 600, 1000 s/mm). Focal nodular hyperplasias were evaluated qualitatively using visual analysis of diffusion-weighted magnetic resonance (DWMR) images and quantitatively using conventional apparent diffusion coefficient (ADC) and normalized ADC measurements. RESULTS: All FNHs (100%) were visible on b0 DWMR images; 26 of the 27 FNHs (96%), on b600 DWMR images; and 21 of the 27 FNHs (78%), on b1000 DWMR images. A total of 18 of the 27 FNHs (67%) exhibited a hyperintense central scar on the b0 DWMR images that remained visible on the b600 and b1000 DWMR images in 6 of the 27 FNHs (22%). Conventional ADC value of FNHs (1.318 × 10 mm/±0.208) was significantly lower than that of adjacent hepatic parenchyma (1.414 × 10 mm/s ± 1.95) (P = 0.0003), although a substantial overlap was found. The use of normalized ADC using the liver as reference organ resulted in a more restricted distribution of ADC values (variation coefficient, 5.3%). CONCLUSIONS: Focal nodular hyperplasias show a wide range of morphological features at DWMRI using high b values. Further studies are needed to fully investigate as to what extent normalized ADC may result in better lesion characterization.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Hiperplasia Nodular Focal do Fígado/diagnóstico , Adulto , Idoso , Algoritmos , Meios de Contraste , Feminino , Hiperplasia Nodular Focal do Fígado/patologia , Humanos , Masculino , Meglumina , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Retrospectivos , Tomografia Computadorizada Espiral , Ultrassonografia Doppler
2.
Eur J Radiol ; 82(11): e655-61, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23957939

RESUMO

OBJECTIVE: To qualitatively and quantitatively compare T2-weighted MR imaging of the liver using volumetric spin-echo with sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE) with conventional turbo spin-echo (TSE) sequence for fat-suppressed T2-weighted MR imaging of the liver. MATERIALS AND METHODS: Thirty-three patients with suspected focal liver lesions had SPACE MR imaging and conventional fat-suppressed TSE MR imaging. Images were analyzed quantitatively by measuring the lesion-to-liver contrast-to-noise ratio (CNR), and the signal-to-noise ratio (SNR) of main focal hepatic lesions, hepatic and splenic parenchyma and qualitatively by evaluating the presence of vascular, respiratory motion and cardiac artifacts. Wilcoxon signed rank test was used to search for differences between the two sequences. RESULTS: SPACE MR imaging showed significantly greater CNR for focal liver lesions (median=22.82) than TSE MR imaging (median=14.15) (P<.001). No differences were found for SNR of hepatic parenchyma (P=.097), main focal hepatic lesions (P=.35), and splenic parenchyma (P=.25). SPACE sequence showed less artifacts than TSE sequence (vascular, P<.001; respiratory motion, P<.001; cardiac, P<.001) but needed a longer acquisition time (228.4 vs. 162.1s; P<.001). CONCLUSION: SPACE MR imaging provides a significantly increased CNR for focal liver lesions and less artifacts by comparison with the conventional TSE sequence. These results should stimulate further clinical studies with a surgical standard of reference to compare the two techniques in terms of sensitivity for malignant lesions.


Assuntos
Algoritmos , Artefatos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/patologia , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...