Med Phys ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38889361

RESUMO

BACKGROUND: The distance traveled by the positron before annihilation with an electron, the so-called positron range, negatively effects the positron emission tomography (PET) image quality for radionuclides emitting high-energy positrons such as Gallium-68 (68Ga). PURPOSE: In this study, the effect of a tissue-independent positron range correction for Gallium-68 (68Ga-PRC) was investigated based on phantom measurements. The effect of the 68Ga-PRC was also explored in four patients. METHODS: The positron range distribution profile of 68Ga in water was generated via Monte Carlo simulation. That profile was mapped to a spatially invariant 3D convolution kernel which was incorporated in the OSEM and Q.Clear reconstruction algorithms to perform the 68Ga-PRC. In addition, each reconstruction method included point spread function (PSF) modeling and time-of-flight information. For both Fluorine-18 (18F) and 68Ga, the NEMA IQ phantom was filled with a sphere-to-background ratio of 10:1 and scanned with the GE Discovery MI 5R PET/CT system. Standard non-positron range correction (PRC) reconstructions were performed for both radionuclides, while also PRC reconstructions were performed for 68Ga. Reconstructions parameters (OSEM: number of updates, Q.Clear: beta value) were adapted to achieve similar noise levels between the corresponding reconstructions. The effect of 68Ga-PRC was assessed for both OSEM and Q.Clear reconstructions and compared to non-PRC reconstructions for 68Ga and 18F in terms of image contrast, noise, recovery coefficient (RC), and spatial resolution. For the clinical validation, 68Ga-labeled prostate-specific membrane antigen (68Ga-PSMA) and 68Ga-DOTATOC PET scans were included of two patients each. For each PET scan, patients were injected with 1.5 MBq/kg of 68Ga-PSMA or 68Ga-DOTATOC and the contrast-to-noise ratio (CNR) was calculated and compared to the non-PRC reconstructions. RESULTS: For OSEM reconstructions, including the 68Ga-PRC improved the RC by 9.4% (3.7%-19.3%) and spatial resolution by 21.7% (4.6 mm vs. 3.6 mm) for similar noise levels. For Q.Clear reconstructions, 68Ga-PRC modeling improved the RC by 6.7% (2.8%-10.5%) and spatial resolution by 15.3% (5.9 mm vs. 5.0 mm) while obtaining similar noise levels. In the patient data, the use of 68Ga-PRC enhanced the CNR by 13.2%. CONCLUSIONS: Including 68Ga-PRC in the PET reconstruction enhanced the image quality of 68Ga PET data compared to the standard non-PRC reconstructions for similar noise levels. Limited patient results also supported this improvement.

2.
Diagnostics (Basel) ; 12(10)2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36292023

RESUMO

Gallium-68 (68Ga) is characterized by relatively high positron energy compared to Fluorine-18 (18F), causing substantial image quality degradation. Furthermore, the presence of statistical noise can further degrade image quality. The aim of this literature review is to identify the recently developed positron range correction techniques for 68Ga, as well as noise reduction methods to enhance the image quality of low count 68Ga PET imaging. The search engines PubMed and Scopus were employed, and we limited our research to published results from January 2010 until 1 August 2022. Positron range correction was achieved by using either deblurring or deep learning approaches. The proposed techniques improved the image quality and, in some cases, achieved an image quality comparable to 18F PET. However, none of these techniques was validated in clinical studies. PET denoising for 68Ga-labeled radiotracers was reported using either reconstruction-based techniques or deep learning approaches. It was demonstrated that both approaches can substantially enhance the image quality by reducing the noise levels of low count 68Ga PET imaging. The combination of 68Ga-specific positron range correction techniques and image denoising approaches may enable the application of low-count, high-quality 68Ga PET imaging in a clinical setting.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...