Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Asian J Surg ; 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38811329
2.
Arq. bras. oftalmol ; 83(2): 92-97, Mar.-Apr. 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1088968

RESUMO

ABSTRACT Purpose: To analyze subclinical keratoconus topography indexes using Pentacam and Orbscan-II measurements to identify evidences for seeking sensitive indexes to screen and diagnose subclinical keratoconus. Methods: Fifty healthy participants (50 eyes) and 40 patients with subclinical keratoconus (40 eyes) were included. Seven common parameters including corneal thickness at the thinnest point; minimum curvature of the front surface (minimum simulated keratometry value, SimK's Min); maximum curvature of the front surface (maximum simulated keratometry value, SimK's Max); the frontal corneal surface best-fit spherical radius of the curvature; the back corneal surface best-fit spherical radius of curvature; the anterior corneal surface height (anterior Diff value); and the posterior corneal surface height (posterior Diff value) measured by Pentacam and Orbscan-II between normal and subclinical keratoconus eyes were compared. Results: Statistical differences between the healthy and subclinical keratoconus groups (p<0.01) were found in all corneal parameters measured using both devices. Differences in the minimum curvature of the front surface (SimK's Min), thinnest point, anterior Diff value, and posterior Diff value were significant between Pentacam and Orbscan-II in the subclinical keratoconus group (p<0.05). Conclusion: The findings of this study identify the differences between normal and subclinical keratoconus eyes at the minimum curvature of the front surface, maximum curvature of the front surface, frontal corneal surface best-fit spherical radius of curvature, back corneal surface best-fit spherical radius of curvature, Anterior Diff value, and Posterior Diff value measures using Orbscan II and Pentacam that can help eye care practitioners clinically diagnose subclinical keratoconus.


RESUMO Objetivo: Analisar os índices subclínicos de to pografia de ceratocone utilizando as medidas feitas com Pentacam e com Orbscan-II para identificar evidências para a busca de índices sensíveis para triagem e diagnóstico de ceratocone subclínico. Métodos: Cinquenta participantes saudáveis (50 olhos) e 40 pacientes com ceratocone subclínico (40 olhos) foram incluídos. Sete parâmetros comuns, incluindo a espessura da córnea no ponto mais fino; a curvatura mínima da superfície frontal (valor mínimo da ceratometria simulada, Min de SimK); a curvatura máxima da superfície frontal (valor máximo da ceratometria simulada, Max de SimK); a superfície frontal e a superfície posterior da córnea de melhor ajuste ao raio da curvatura, a altura da superfície anterior da córnea (valor Diff anterior) e a altura da superfície corneana posterior (valor Diff posterior) medidos pelo Pentacam e pelo Orbscan-II entre os olhos normais e com ceratocone subclínico foram comparados. Resultados: As diferenças estatísticas entre os grupos saudável e com ceratocone subclínico (p<0,01) foram encontradas em todos os parâmetros corneanos medidos usando ambos os dispositivos. Diferenças na curvatura mínima da superfície frontal (Min de SimK) no ponto mais fino, no valor Diff anterior e no valor Diff posterior foram significativas entre Pentacam e Orbscan-II no grupo com ceratocone subclínico (p<0,05). Conclusão: Os achados deste estudo identificam as diferenças entre olhos normais e com ceratocone subclínico para a curvatura mínima da superfície frontal, a curvatura máxima da superfície frontal, a superfície corneana frontal e a superfície corneana posterior de melhor ajuste ao raio esférico da curvatura e as medidas de Diff anterior e posterior usando Orbscan II e o Pentacam que podem auxiliar os profissionais de oftalmologia a diagnosticar clinicamente o ceratocone subclínico.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Adulto Jovem , Córnea/patologia , Córnea/diagnóstico por imagem , Topografia da Córnea/instrumentação , Ceratocone/patologia , Ceratocone/diagnóstico por imagem , Valores de Referência , Estudos de Casos e Controles , Estudos Prospectivos , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Topografia da Córnea/métodos
3.
Arq Bras Oftalmol ; 83(2): 92-97, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31778445

RESUMO

PURPOSE: To analyze subclinical keratoconus topography indexes using Pentacam and Orbscan-II measurements to identify evidences for seeking sensitive indexes to screen and diagnose subclinical keratoconus. METHODS: Fifty healthy participants (50 eyes) and 40 patients with subclinical keratoconus (40 eyes) were included. Seven common parameters including corneal thickness at the thinnest point; minimum curvature of the front surface (minimum simulated keratometry value, SimK's Min); maximum curvature of the front surface (maximum simulated keratometry value, SimK's Max); the frontal corneal surface best-fit spherical radius of the curvature; the back corneal surface best-fit spherical radius of curvature; the anterior corneal surface height (anterior Diff value); and the posterior corneal surface height (posterior Diff value) measured by Pentacam and Orbscan-II between normal and subclinical keratoconus eyes were compared. RESULTS: Statistical differences between the healthy and subclinical keratoconus groups (p<0.01) were found in all corneal parameters measured using both devices. Differences in the minimum curvature of the front surface (SimK's Min), thinnest point, anterior Diff value, and posterior Diff value were significant between Pentacam and Orbscan-II in the subclinical keratoconus group (p<0.05). CONCLUSION: The findings of this study identify the differences between normal and subclinical keratoconus eyes at the minimum curvature of the front surface, maximum curvature of the front surface, frontal corneal surface best-fit spherical radius of curvature, back corneal surface best-fit spherical radius of curvature, Anterior Diff value, and Posterior Diff value measures using Orbscan II and Pentacam that can help eye care practitioners clinically diagnose subclinical keratoconus.


Assuntos
Córnea/diagnóstico por imagem , Córnea/patologia , Topografia da Córnea/instrumentação , Ceratocone/diagnóstico por imagem , Ceratocone/patologia , Adolescente , Adulto , Estudos de Casos e Controles , Topografia da Córnea/métodos , Feminino , Humanos , Masculino , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Adulto Jovem
4.
Nan Fang Yi Ke Da Xue Xue Bao ; 38(11): 1389-1394, 2018 Nov 30.
Artigo em Chinês | MEDLINE | ID: mdl-30514691

RESUMO

OBJECTIVE: To study the anti- scarring effect of rapamycin in rabbits receiving glaucoma filtering surgery. METHODS: Ninety-six Chinchilla rabbits were randomized equally into 3 rapamycin treatment groups and one control group. All the rabbits underwent trabeculectomy, after which the rabbits in the 3 rapamycin groups were treated with eye drops containing 1%, 3%, or 5% rapamycin in the operated eyes, and those in the control groups were given castor oil 4 times a day. The intraocular pressure (IOP) and inflammatory reaction in the treated eyes were observed, and the PCNA-positive cells in the filtering bleb were detected using immunohistochemistry. RTFs isolated from the Tenon's capsule of the rabbits were cultured in vitro, and the expressions of caspase-3, caspase-8, and caspase-9 in the fibroblasts were detected after treatment with different concentrations of rapamycin. RESULTS: The IOP was significantly lower in rapamycin-treated group than in the control group after the surgery (P < 0.05). The counts of the PCNA-positive cells were significantly lower in rapamycin-treated rabbits than in the control group (P < 0.05). Rapamycin treatment dose-dependently increased the expressions of caspase-3 and caspase- 9 at both the mRNA (P < 0.001) and protein (P < 0.001) levels without causing significant changes in the expressions of caspase-8. CONCLUSIONS: Rapamycin can inhibit excessive proliferation of the fibroblasts in the filtering bleb to reduce scar formation after glaucoma filtration surgery in rabbits. Rapamycin also increases the expressions of caspase-3 and caspase-9 to induce apoptosis of the RTFs.


Assuntos
Cicatriz/prevenção & controle , Cirurgia Filtrante/efeitos adversos , Glaucoma/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Sirolimo/uso terapêutico , Animais , Caspase 3/metabolismo , Caspase 9/metabolismo , Proliferação de Células/efeitos dos fármacos , Pressão Intraocular , Complicações Pós-Operatórias/enzimologia , Antígeno Nuclear de Célula em Proliferação/análise , Coelhos , Distribuição Aleatória , Trabeculectomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...