Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 95(6): 3406-3413, 2023 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-36735826

RESUMO

Infrared ion spectroscopy (IRIS) can be used to identify molecular structures detected in mass spectrometry (MS) experiments and has potential applications in a wide range of analytical fields. However, MS-based approaches are often combined with orthogonal separation techniques, in many cases liquid chromatography (LC). The direct coupling of LC and IRIS is challenging due to the mismatching timescales of the two technologies: an IRIS experiment typically takes several minutes, whereas an LC fraction typically elutes in several seconds. To resolve this discrepancy, we present a heartcutting LC-IRIS approach using a setup consisting of two switching valves and two sample loops as an alternative to direct online LC-IRIS coupling. We show that this automated setup enables us to record multiple IR spectra for two LC-features from a single injection without degrading the LC-separation performance. We demonstrate the setup for application in drug metabolism research by recording six m/z-selective IR spectra for two drug metabolites from a single 2 µL sample of cell incubation extract. Additionally, we measure the IR spectra of two closely eluting diastereomeric biomarkers for the inborn error of metabolism pyridoxine-dependent epilepsy (PDE-ALDH7A1), which shows that the heartcutting LC-IRIS setup has good sensitivity (requiring ∼µL injections of ∼µM samples) and that the separation between closely eluting isomers is maintained. We envision applications in a range of research fields, where the identification of molecular structures detected by LC-MS is required.


Assuntos
Cromatografia Líquida , Espectrometria de Massas , Espectrofotometria Infravermelho
2.
Analyst ; 147(2): 333-340, 2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-34932048

RESUMO

Highlighter inks were analyzed by means of soft Desorption/Ionization induced by Neutral SO2 clusters (DINeC) in combination with mass spectrometry (MS). The dye molecules of the different inks were directly desorbed from dots of ink drawn on arbitrary substrates. Fragmentation free spectra were observed and the dyes used in the dye mixtures of the different highlighter inks were unambiguously identified. The soft nature of cluster-induced desorption was used to investigate the decomposition of the dye molecules induced by either heat or UV-light. The two processes lead to different decomposition products which are clearly distinguished in the DINeC spectra. The two different degradation processes can thus be discriminated using DINeC-MS.

3.
J Vis Exp ; (157)2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32176198

RESUMO

Desorption/Ionization Induced by Neutral SO2 Clusters (DINeC) is employed as a very soft and efficient desorption/ionization technique for mass spectrometry (MS) of complex molecules and their reactions on surfaces. DINeC is based on a beam of SO2 clusters impacting on the sample surface at low cluster energy. During cluster-surface impact, some of the surface molecules are desorbed and ionized via dissolvation in the impacting cluster; as a result of this dissolvation-mediated desorption mechanism, low cluster energy is sufficient and the desorption process is extremely soft. Both surface adsorbates and molecules of which the surface is composed of can be analyzed. Clear and fragmentation-free spectra from complex molecules such as peptides and proteins are obtained. DINeC does not require any special sample preparation, in particular no matrix has to be applied. The method yields quantitative information on the composition of the samples; molecules at a surface coverage as low as 0.1 % of a monolayer can be detected. Surface reactions such as H/D exchange or thermal decomposition can be observed in real-time and the kinetics of the reactions can be deduced. Using a pulsed nozzle for cluster beam generation, DINeC can be efficiently combined with ion trap mass spectrometry. The matrix-free and soft nature of the DINeC process in combination with the MSn capabilities of the ion trap allows for very detailed and unambiguous analysis of the chemical composition of complex organic samples and organic adsorbates on surfaces.


Assuntos
Angiotensina II/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Medição da Troca de Deutério , Cinética , Simulação de Dinâmica Molecular , Proteólise , Propriedades de Superfície , Temperatura , Vácuo
4.
Biointerphases ; 15(2): 021001, 2020 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-32164418

RESUMO

Desorption/ionization induced by neutral clusters (DINeC) is used as an ultrasoft desorption/ionization method for the analysis of fragile biomolecules by means of mass spectrometry (MS). As a test molecule, the glycopeptide vancomycin was measured with DINeC-MS, and resulting mass spectra were compared to the results obtained with electrospray ionization (ESI), matrix assisted laser desorption ionization, and time-of-flight secondary ion MS. Of the desorption-based techniques, DINeC spectra show the lowest abundance of fragments comparable to ESI spectra. The soft desorption nature of DINeC was further demonstrated when applied to MS analysis of teicoplanin.


Assuntos
Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Peptídeos/química , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massa de Íon Secundário , Vancomicina/farmacologia
5.
ACS Omega ; 4(27): 22426-22430, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31909324

RESUMO

Desorption/ionization induced by neutral clusters (DINeC) was employed for mass spectrometry (MS) of oligopeptides and lipids after separation by means of thin-layer chromatography (TLC). Clear and fragmentation-free spectra were obtained from the TLC plates without any further sample treatment. Mass-resolved chromatograms were deduced when scanning the TLC plates with the cluster beam along the direction of solvent movement. Using vancomycin and noncovalently bound complexes, the soft nature of DINeC was demonstrated also when used in combination with TLC. As a test application, TLC and DINeC-MS were employed to separate and detect different phospholipids obtained from egg yolk.

6.
J Phys Chem B ; 121(49): 11031-11036, 2017 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-29160071

RESUMO

The kinetics of the H/D exchange reaction in angiotensin II, hexaglycine (Gly6), Co(II)tetra(3-carboxyphenyl)porphyrin, and tetra(4-carboxyphenyl)porphyrin were followed in real time by mass spectrometry employing desorption/ionization induced by neutral SO2 clusters. The change of the isotope patterns with increasing degree of deuteration was recorded as a function of D2O exposure and the underlying H/D exchange kinetics, i.e., the dependence of the different degrees of deuteration on time, were deduced. The results were modeled by means of Monte Carlo simulations taking into account different reaction constants for the H/D exchange reaction at different functional groups. In the case of the investigated porphyrins, the rate constants were directly assigned to the functional groups involved; in the case of the peptides, reaction at the explicit functional groups and the backbone chain of the molecules could be discriminated.


Assuntos
Medição da Troca de Deutério , Oligopeptídeos/química , Porfirinas/química , Cinética , Simulação de Dinâmica Molecular , Estrutura Molecular , Método de Monte Carlo , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Fatores de Tempo
7.
Rev Sci Instrum ; 87(10): 103108, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27802712

RESUMO

We report on modifications made to a Paul-type quadrupole ion trap mass spectrometer and discuss its application in infrared ion spectroscopy experiments. Main modifications involve optical access to the trapped ions and hardware and software coupling to a variety of infrared laser sources at the FELIX infrared free electron laser laboratory. In comparison to previously described infrared ion spectroscopy experiments at the FELIX laboratory, we find significant improvements in efficiency and sensitivity. Effects of the trapping conditions of the ions on the IR multiple photon dissociation spectra are explored. Enhanced photo-dissociation is found at lower pressures in the ion trap. Spectra obtained under reduced pressure conditions are found to more closely mimic those obtained in the high-vacuum conditions of an Fourier transform ion cyclotron resonance mass spectrometer. A gas-mixing system is described enabling the controlled addition of a secondary gas into helium buffer gas flowing into the trap and allows for ion/molecule reactions in the trap. The electron transfer dissociation (ETD) option of the mass spectrometer allows for IR structure characterization of ETD-generated peptide dissociation products.

8.
Biointerphases ; 11(2): 02A316, 2016 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-26825286

RESUMO

Oligopeptides in the presence of large amounts of salt were desorbed and ionized using desorption/ionization induced by neutral clusters (DINeC) for further analysis by means of mass spectrometry (MS). Using oligopeptides in alkali halide solutions as a model system, DINeC was shown to yield clear and fragmentation free mass spectra of the biomolecules even from environments with a large excess of salt. The results were traced back to a phase separation between salt and biomolecules during sample preparation. The ratio between alkali metal complexes [M+A](+) and bare biomolecules [M+H](+) was controlled using different preparation schemes. DINeC was applied to the products of a tryptic digest of bovine serum albumin in the presence of sodium chloride; the results of a mass fingerprint analysis did not show a major difference for the spectra with and without salt in the original solution. The metal-ion/peptide interaction was further investigated by means of tandem-MS.


Assuntos
Espectrometria de Massas/métodos , Oligopeptídeos/análise , Soroalbumina Bovina/metabolismo , Cloreto de Sódio , Tripsina/metabolismo
9.
Rapid Commun Mass Spectrom ; 28(3): 290-6, 2014 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-24375880

RESUMO

RATIONALE: Desorption and ionization induced by neutral clusters (DINeC) using SO2 as cluster constituents was previously shown to produce clear and fragmentation-free spectra with low background from samples prepared with standard oligopeptides. Here we demonstrate a more general applicability of this method based on examples from different classes of (bio-)molecules. In order to make better use of the ions generated during the millisecond cluster-pulse, the DINeC source was combined with an ion trap mass spectrometer. METHODS: Desorption and ionization was induced by neutral SO2 clusters with a mean size of 10(3) to 10(4) molecules seeded in a pulsed He beam. The desorbed ions were accumulated in an ion trap over the whole pulse duration prior to mass spectrometric analysis. Samples were prepared by simply drop casting the respective aqueous solution of biomolecules on Si/SiO2 substrates. RESULTS: Clear and fragmentation-free spectra of oligopeptides were detected in single pulse operation mode. The very soft nature of the desorption process was demonstrated for phosphopeptides. DINeC spectra from bovine serum albumin samples after tryptic digest led to a clear identification of the original sequence using mass fingerprinting analysis. MS(n) capability was illustrated with two types of rhodamine dyes. CONCLUSIONS: Desorption and ionization induced by neutral clusters can efficiently be combined with ion trap mass spectrometry since the pulse width and repetition rate of a typical pulsed cluster beam correspond well to the discontinuous accumulation time as well as the spectral rate of the ion trap. Clear mass spectra were obtained with such a setup for a variety of biosamples demonstrating the wider applicability of the DINeC process.


Assuntos
Espectrometria de Massas/métodos , Fragmentos de Peptídeos/análise , Animais , Bovinos , Fragmentos de Peptídeos/química , Mapeamento de Peptídeos , Soroalbumina Bovina/análise , Soroalbumina Bovina/química , Dióxido de Silício/química , Tripsina
10.
Angew Chem Int Ed Engl ; 48(23): 4162-5, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19283812

RESUMO

All in a ball: Neutral molecular clusters consisting of a few thousand molecules can be seen as tiny snow balls; if they are thrown fast enough onto a surface, they are able to pick up biomolecules such as insulin from that surface. Since they break down and evaporate during and after the collision, bare biomolecular ions are available for mass spectrometry after such an energetic throw.


Assuntos
Aminoácidos/química , Proteínas/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Dióxido de Enxofre/química , Íons/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...