Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Child Orthop ; 17(3): 276-283, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37288041

RESUMO

Background: Percutaneous femoral derotational osteotomies are performed in both adult and pediatric patients. There is little published on the outcomes after femoral derotational osteotomy in pediatric patients. Methods: A retrospective cohort study of pediatric patients treated with percutaneous femoral derotational osteotomy by one of two surgeons between 2016 and 2022 was performed. Data collected included patient demographics; surgical indications; femoral version; tibial torsion; magnitude of rotational correction; complications; time to hardware removal; pre-operative and post-operative patient-reported outcome scores, including Limb Deformity-Scoliosis Research Society and Patient-Reported Outcomes Measurement Information System; and time to consolidation. Descriptive statistics were used to summarize the data and t tests used to compare means. Results: Thirty-one femoral derotational osteotomies in 19 patients were included with an average age of 14.7 (9-17) years. The average rotational correction was 21.5° ± 6.4° (10°-40°). The average length of follow-up was 17.9 ± 6.7 months. There were no instances of nonunion, joint stiffness, or nerve injury. No patients returned to the operating room for additional surgeries other than routine hardware removal. There were no cases of avascular necrosis of the femoral head. Of the 19 patients, 8 completed both a pre-operative and post-operative survey set. There were significant improvements in the Limb Deformity-Scoliosis Research Society Self-Image/Appearance sub-category and the Patient-Reported Outcomes Measurement Information System Physical Function sub-category. Conclusion: Femoral derotational osteotomy using a percutaneous drill hole technique with antegrade trochanteric entry femoral nail is safe in the pediatric population and improves self-image in patients with symptomatic femoral version abnormalities.

2.
Artigo em Inglês | MEDLINE | ID: mdl-37205724

RESUMO

BACKGROUND: Fixator-assisted nailing techniques that incorporate magnetic internal lengthening nails (MILNs) permit acute deformity correction and then gradual limb lengthening without needing postoperative external fixators. PURPOSES: We sought to investigate the safety and accuracy of a fixator-assisted, blocking screw technique using retrograde MILNs for the correction of LLD and limb malalignment. METHODS: Forty-one patients (13 patients with genu varum and 28 patients with genu valgum) with LLD treated with fixator-assisted, blocking screw retrograde MILN reconstruction were included. Preoperative LLD, mechanical axis deviation, and joint orientation angles were compared with values at the end of treatment, and bone healing indices were calculated. Perioperative complications were tracked. RESULTS: Preoperatively, the mean mechanical lateral distal femoral angle of the varus cohort was 98 ± 12°, whereas the mean lateral distal femoral angle of the valgus cohort was 82±4°. Both cohorts had an average 3-cm LLD. 99% of the planned limb lengthening was achieved. Final LDFAs were 91 ± 6° and 89 ± 4° in the varus and valgus cohorts, respectively, and the limb mechanical axis angles were normalized. 10 patients underwent a total of 21 returns to the operating room. Most commonly, this involved percutaneous injection of bone marrow aspirate concentrate to bone regenerate exhibiting delayed union (6 patients). CONCLUSIONS: The use of a retrograde MILN with a fixator-assisted, blocking screw technique is an effective means of acute deformity correction and gradual limb lengthening through minimal incisions. The accuracy of deformity correction relies on intraoperative execution of the appropriate nail start site, osteotomy location, and placement of blocking screws.


Assuntos
Fêmur , Extremidade Inferior , Humanos , Resultado do Tratamento , Fêmur/cirurgia , Parafusos Ósseos , Fenômenos Magnéticos
3.
J Orthop Trauma ; 37(11): e459-e465, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36750433

RESUMO

SUMMARY: Critical-sized bone defects in the tibia can arise as sequelae of trauma, infection, tumor, or the treatment of congenital limb deficiencies. Treatment of these defects often requires bone transport, which has traditionally been accomplished using circular external fixators. The development of a bone transport nail facilitated tibia reconstruction through distraction osteogenesis using an all-internal device, thus avoiding the complications associated with chronic external fixation. Given the rarity of these cases, few studies have been published on the reconstruction outcomes using this implant. We sought to investigate the bone healing indices (including regenerate consolidation and time to docking site union) associated with the use of a magnetically controlled all-internal bone transport nail for the reconstruction of 4 patients treated for posttraumatic tibial bone loss. Perioperative and device-related complications are also reported.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...