Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Case Rep Otolaryngol ; 2022: 4918785, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35223118

RESUMO

OBJECTIVE: The vestibular schwannoma incidence rate is approximately 4.2 per 100,000/year. Thus far, about 700,000 cochlear implantations have been performed worldwide; therefore, the occurrence of vestibular schwannoma postcochlear implantations can be assumed to be infrequent. Recent developments allow safe observation and surveillance of the implanted-side internal auditory canal (IAC) and cochlea by magnetic resonance imaging (MRI), even after cochlear implantation. Patients. A 71-year-old woman with sudden hearing loss and a contralateral vestibular schwannoma without clinical and genetic signs of neurofibromatosis type II. Intervention(s). Ipsilateral cochlear implantation and contralateral vestibular schwannoma extirpation with regular tumor follow-up. Main Outcome Measure(s). Comparison of ipsilateral pre and postcochlear implantation 3T MRI T1 GAD. RESULTS: We observed a tumor growing at the fundus of the internal auditory canal 1 year after cochlear implantation on the ipsilateral side. Although first detected after cochlear implantation beside a known vestibular schwannoma on the contralateral side, a scan slice thickness of 2 mm cannot fully exclude the preoperative persistence of a small tumor. Based on the clinical findings and after genetic exclusion of NFII, the patient was classified as a NFII mosaic type. CONCLUSION: Even after cochlear implantation, tumors in the IAC causing vertigo, facial palsy, and affecting the audiologic outcome can be detected by MRI. The MRI slice thickness used before cochlear implantation should be under 2 mm.

2.
Sci Rep ; 11(1): 21298, 2021 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-34716377

RESUMO

The estimation of scalar electrode position is a central point of quality control during the cochlear implant procedure. Ionic radiation is a disadvantage of commonly used radiologic estimation of electrode position. Recent developments in the field of cochlear implant magnets, implant receiver magnet position, and MRI sequence usage allow the postoperative evaluation of inner ear changes after cochlear implantation. The aim of the present study was to evaluate the position of lateral wall and modiolar cochlear implant electrodes using 3 T MRI scanning. In a prospective study, we evaluated 20 patients (10× Med-El Flex 28; 5× HFMS AB and 5× SlimJ AB) with a 3 T MRI and a T2 2D Drive MS sequence (voxel size: 0.3 × 0.3 × 0.9 mm) for the estimation of the intracochlear position of the cochlear implant electrode. In all cases, MRI allowed a determination of the electrode position in relation to the basilar membrane. This observation made the estimation of 19 scala tympani electrode positions and a single case of electrode translocation possible. 3 T MRI scanning allows the estimation of lateral wall and modiolar electrode intracochlear scalar positions.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Eletrodos Implantados , Humanos , Imageamento por Ressonância Magnética , Imãs , Estudos Prospectivos
3.
Eur Arch Otorhinolaryngol ; 278(8): 2763-2767, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32909061

RESUMO

PURPOSE: A new generation of cochlear implant (CI) magnets and specific surgical techniques (e.g., implant positioning) has changed the relationship between a CI and magnet resonance imaging (MRI). MRI allows a pain free in vivo evaluation of the inner ear fluid state and internal auditory canal after the insertion of an electrode. The aim of this study is to evaluate how the patient's head position in the MRI scanner influences the CI magnet-related artefact. METHODS: We performed in vivo measurement of MRI artefacts at 3 T with a CI system containing a bipolar diametrical magnet. The implant magnet was positioned with a head bandage at different positions from the nasion and external auditory canal in three volunteers. We used a turbo spin echo (TSE) T2w sequence on the axial and coronal planes and observed three positions: (1) regular position, (2) chin to chest (anteflexion), and (3) hyperextension (retroflexion). RESULTS: By comparing the positions, anteflexion of the cervical spine in a chin-to-chest position allowed us to place the artefact in a more apical position from the IAC in the coronal plane. The hyperextension of the cervical spine position shifts the artefact father towards the cochlea's direction. CONCLUSION: The head's position can influence the location of MRI artefacts. In cases where the artefact diminished the IAC or cochlea, anteflexion of the cervical spine in the chin-to-chest position of the head in the MRI scanner should be attempted to allow a visualization of the IAC.


Assuntos
Implantes Cocleares , Orelha Interna , Artefatos , Orelha Interna/diagnóstico por imagem , Orelha Interna/cirurgia , Humanos , Imageamento por Ressonância Magnética , Imãs
4.
Biomed Res Int ; 2020: 5086291, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32420348

RESUMO

INTRODUCTION: Recent developments regarding cochlear implant magnets (e.g., a bipolar diametral magnet) and refined surgical techniques (e.g., implant positioning) have had a significant impact on the relation between cochlear implants and MRIs, making the reproducible visibility of cochlea and IAC possible. MRI scanning has changed from a contraindication to a diagnostic tool. Magnet artifact size plays a central role in the visual assessment of the cochlea and IAC. OBJECTIVE: The aim of this study is to compare the CI magnet-related maximum artifact sizes of various cochlea implant systems. MATERIALS AND METHODS: We performed an in vivo measurement of MRI artifacts at 1.5 and 3 Tesla with three cochlear implant magnet systems (AB 3D, Medel Synchrony, and Oticon ZTI). The implant, including the magnet, was positioned with a head bandage 7.0 cm and 120° from the nasion, external auditory canal. We used a TSE T2w MRI sequence on the axial and coronal plains and compared the artifacts in two volunteers for each tesla strength. RESULTS: Intraindividual artifact size differences between the three magnets are smaller than interindividual maximum artifact size differences. 3 T MRI scans, in comparison to 1.5 T MRI scans, show a difference between soft artifact areas. CONCLUSION: We observed no major difference between maximum implant magnet artifact sizes of the three implant magnet types.


Assuntos
Implantes Cocleares , Orelha Interna/diagnóstico por imagem , Imageamento por Ressonância Magnética/normas , Imãs , Artefatos , Humanos
5.
HNO ; 68(1): 55-58, 2020 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-31531685

RESUMO

Adenomas are very rare tumors of the middle ear. They are benign neoplasms originating from the glandular components of the mucous membrane of the middle ear. The middle ear adenoma was first described by Hyams and Michaels in 1976, which was named an adenomatous tumor. This article reports the case of a 50-year-old female patient, who presented with recurrent right-sided dull otalgia and pulse synchronous tinnitis, which began 1 year prior to presentation, with the suspected diagnosis of a glomus tympanicum tumor. Following the otorhinolaryngological examination and imaging an unclear mesotympanal space-occupying lesion was detected. A transmeatal endoscopic complete removal of the tumor was carried out. The histopathological investigations enabled the diagnosis of an adenoma of the middle ear. Adenomas are a rare differential diagnosis of tumors of the middle ear. In cases with a suitable localization an adequate exposure and removal of this rare tumor can be achieved by a transmeatal endoscopic access.


Assuntos
Adenoma , Neoplasias da Orelha , Adenoma/diagnóstico , Adenoma/patologia , Adenoma/terapia , Neoplasias da Orelha/diagnóstico , Neoplasias da Orelha/patologia , Neoplasias da Orelha/terapia , Orelha Média , Endoscopia , Feminino , Humanos , Pessoa de Meia-Idade , Osso Temporal
7.
Eur J Cancer Care (Engl) ; 22(5): 648-52, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23701280

RESUMO

Poorly differentiated head and neck neuroendocrine neoplasms are very rare. Surgical resection alone is insufficient to control the disease because of the high incidence of metastases. However, due to the lack of randomised clinical trials, treatment recommendations for this cancer vary considerably and are based on a limited number of small retrospective studies. We performed a retrospective analysis of all patients treated at our institution between 2003 and 2011. We assessed the stage of disease, type of therapy, toxicity, treatment response, time to progression and overall survival for all cases. Ten patients received combined modality treatment with chemotherapy in addition to surgery or radiation or both. According to Response Evaluation Criteria In Solid Tumours (RECIST) criteria, six of nine evaluable patients achieved complete remission and three patients had a partial remission. The mean duration of response was 358 days, with a range from 141 to 1080 days. The overall 1-year survival rate was 88%; however, only approximately 50% of patients were alive after 2 years. Multimodality treatment concepts induce high initial remission rates in poorly differentiated neuroendocrine head and neck carcinomas. However, the time to relapse is usually short, and therefore long-term prognosis of this rare head and neck tumour remains poor.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carcinoma Neuroendócrino/tratamento farmacológico , Carcinoma de Células Pequenas/tratamento farmacológico , Carcinoma de Células Escamosas/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Adulto , Idoso , Carboplatina/administração & dosagem , Carcinoma Neuroendócrino/radioterapia , Carcinoma Neuroendócrino/cirurgia , Carcinoma de Células Pequenas/radioterapia , Carcinoma de Células Pequenas/cirurgia , Carcinoma de Células Escamosas/radioterapia , Carcinoma de Células Escamosas/cirurgia , Cisplatino/administração & dosagem , Terapia Combinada/métodos , Etoposídeo/administração & dosagem , Feminino , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Carcinoma de Células Escamosas de Cabeça e Pescoço , Resultado do Tratamento
8.
Handchir Mikrochir Plast Chir ; 43(2): 81-7, 2011 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-20821365

RESUMO

Muscle sparing TRAM flaps and DIEA perforator flaps are standard procedures for breast reconstruction. Recently CT-angiography has been established to evaluate perforator vessels pre-operatively. CT-angiography was introduced to our department in July 2009. In a retrospective analysis data of the last 20 patients (altogether 22 flaps) before CT-angiography introduction and the following 20 (also 22 flaps) patients after introduction of CT-angiography were analysed with regard to the ratio of TRAM to DIEP flaps, and the time required to raise the flaps. The same surgeon raised all flaps. As different surgeons performed dissection of the recipient site, anastomoses, and insertion of flaps, and patients received primary (with sentinel or complete lymphadenctomy) or secondary reconstructions, only the time required harvesting the flap was compared. Thus other influences on raising the flap were eliminated. DIEP flaps were harvested with one single perforator. If perfusion or was considered not to be safe via one single perforator a muscle sparing TRAM flap (ms2) was raised. Angiography was performed using a 64-slice multi-detector CT scanner. CT-angiography did not lead to an increased rate of DIEP flaps in relation to ms2-TRAM flaps. Harvesting time of all flap types with CT-angiography on average was 121 min, without CT-angiography 135 min. This was not significantly different. However, separate analysis of DIEP flaps and ms2-TRAM flaps revealed a significant advantage of CT-angiography based harvesting of DIEP flaps of 26 min: with CT-angiography 101 min vs. 127 min without CT-angiography (p<0.028). There were no significant differences for ms2-TRAM flaps. All scans showed course and branching, diameter and size of the inferior epigastric artery. If evident the superficial inferior epigastric artery (SIEA) was marked. Dosage was 292 mGy-606 mGy×cm dependent on body weight. CTDI was 6.8-14.7 mGy. CT-angiography is a reproducible and observer independent procedure that reliably demonstrates the inferior epigastric artery and its perforating branches. Sensitivity is considered to be 99,6%. Additionally the superficial inferior epigastric artery can be evaluated. In our patients the ratio of ms2-TRAM flaps to DIEP flaps was not affected by introducing CT-angiography. However, DIEP flap harvesting was significantly accelerated. Harvesting of ms2-TRAM flaps was not affected. It remains to be seen whether the observed time advantage is really essential for this operation. Preoperative imaging of the perforators allows establishing a detailed, observable and comprehensible operation strategy, which particularly facilitates surgical training and learning of perforator dissection.


Assuntos
Angiografia , Mamoplastia/métodos , Microcirurgia/métodos , Retalhos Cirúrgicos/irrigação sanguínea , Coleta de Tecidos e Órgãos/métodos , Tomografia Computadorizada por Raios X , Artérias Epigástricas/diagnóstico por imagem , Artérias Epigástricas/cirurgia , Feminino , Humanos , Microvasos/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade
9.
Forensic Sci Int ; 146(2-3): 111-20, 2004 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-15542271

RESUMO

OBJECTIVES: Reconstruction of brain injuries is a basic task of forensic neuropathology. For better understanding of the wound ballistics of gunshot injuries to the brain caused by low-velocity firearms (E(o) < 550 J), we reviewed the respective contributions of: (1) biomechanical reconstruction by postmortem imaging techniques, (2) biometry of the extent of very early microscopic tissue destruction, and (3) microscopic studies on the type and extent of early microscopic reactions around the permanent missile track. MATERIAL AND METHODS: A selected case material of 47 victims of lethal gunshot wounding to the brain was studied. (1) Computed tomography (CT) and magnetic resonance imaging (MRI) techniques were compared with macroscopic findings in 17 cases. (2) Morphometric evaluation of the zones of cellular and axonal destruction around the permanent track was performed in 20 cases (survival time: <90 min). (3) Microscopic studies of the emigration of leukocytes and macrophages plus axonal expression of beta-amyloid precursor protein (beta-APP) were conducted in 10 cases (survival time: >90 min). RESULTS AND CONCLUSIONS: (1) Imaging procedures provided valuable information on entrance and exit wounds, the missile track and secondary changes. (2) Biometry revealed a destruction zone of ca. 3.6 cm around the permanent track corresponding to the "temporary cavity". (3) Microscopic studies of reactive changes demonstrated axonal injury at sites remote from the permanent cavity that could explain the very early respiratory arrest following low-velocity gunshot injury.


Assuntos
Lesões Encefálicas/patologia , Encéfalo/patologia , Patologia Legal , Traumatismos Cranianos Penetrantes/patologia , Ferimentos por Arma de Fogo/patologia , Precursor de Proteína beta-Amiloide/metabolismo , Axônios/metabolismo , Movimento Celular , Balística Forense , Humanos , Leucócitos/patologia , Macrófagos/patologia , Imageamento por Ressonância Magnética , Necrose , Tomografia Computadorizada por Raios X
10.
Chirurg ; 75(9): 850-60, 2004 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-15258747

RESUMO

Clinical symptoms in descending perineum syndrome show considerable variations, ranging from obstructed defecation to combined fecal and urinary incontinence and including different types of prolapse. Differential diagnosis has to compete with this complexity. Common pelvic floor disorders associated with descending perineum are rectocele, rectal prolapse, enterocele, and sigmoidocele. Standardized diagnostic tools include detailed history and clinical examination with proctorectoscopy as well as anorectal manometry, endoanal ultrasound, defecography, and dynamic MR of the pelvic floor. The diagnosis and proposed therapy have to be developed within an interdisciplinary concept.


Assuntos
Constipação Intestinal/diagnóstico , Defecografia , Incontinência Fecal/diagnóstico , Diafragma da Pelve , Períneo , Prolapso Retal/diagnóstico , Retocele/diagnóstico , Doença Crônica , Diagnóstico Diferencial , Endossonografia , Incontinência Fecal/diagnóstico por imagem , Feminino , Hérnia/diagnóstico , Humanos , Imageamento por Ressonância Magnética , Masculino , Manometria , Períneo/fisiopatologia , Proctoscopia , Sensibilidade e Especificidade , Síndrome
11.
Eur Radiol ; 14(8): 1421-6, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15022012

RESUMO

The purpose of this study was to demonstrate the macroscopic and MRI anatomy of the fasciculus obliquus, otherwise known as the ligamentum glenohumerale spirale or spiral GHL of the anterior shoulder joint capsule. Conventional and MR arthrography (1.5-T device Somatom Symphony, Siemens with shoulder coil) images in standard planes were compared with gross anatomic dissection findings in six fresh shoulder specimens from three cadavers. The MR imaging protocol included T1, PD and DESS 3D WI sequences. The macroscopically recognisable band-the spiral GHL-was identified by anatomic dissection and MRI in all the specimens. It was best visualised by MR arthrography on axial and oblique sagittal planes (T1; PD WI) and appeared as a low signal intensity stripe within the superficial layer of the anterior joint capsule. The absence of the variable middle glenohumeral ligament did not influence the anatomic properties and the MR imaging of the spiral GHL. Diagnostic visualisation of the normal anatomic structures is a prerequisite to distinguish between normal and pathologic conditions. Anatomy of the spiral GHL can be used by radiologists for more detailed interpretation of the anterior shoulder joint capsule ligaments on MR images.


Assuntos
Imageamento por Ressonância Magnética/métodos , Articulação do Ombro/anatomia & histologia , Idoso , Idoso de 80 Anos ou mais , Artrografia , Cadáver , Meios de Contraste/administração & dosagem , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Ligamentos Articulares/anatomia & histologia , Ligamentos Articulares/diagnóstico por imagem , Masculino , Ilustração Médica , Articulação do Ombro/diagnóstico por imagem
12.
Clin Nephrol ; 62(6): 423-31, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15630901

RESUMO

AIMS: We evaluated different techniques of contrast-enhanced phase-inversion ultrasound to visualize renal perfusion in native kidneys and kidney transplants. MATERIALS AND METHODS: Contrast-enhanced phase inversion ultrasound with different levels of mechanical index and frame rate was performed in 20 kidneys of 13 healthy volunteers. In addition, five dysfunctioning kidneys of patients with chronic renal failure, five functionally intact kidney transplants, three kidney transplants with compensated renal failure, and two kidney transplants with acute rejection were studied. Analysis using a software algorithm for time-resolved perfusion imaging was compared to single-image analysis performed by three independent radiologists. RESULTS: Optimal depiction of renal perfusion was achieved only by using a mechanical index, which was high enough to destroy the microbubbles of the contrast agent (burst imaging) combined with a low frame rate (0.5 images/second). Renal cortex and medulla showed a homogeneous enhancement in kidneys of healthy volunteers and functionally intact renal transplants. Dysfunctioning kidneys of patients with chronic renal failure as well as kidney transplants with compensated renal failure or acute rejection showed a significantly reduced level of enhancement. Computer-assisted time-resolved perfusion analysis was not superior to single-image analysis. CONCLUSION: Renal perfusion patterns of normal and abnormal tissue can be visualized using contrast-enhanced phase-inversion ultrasound imaging.


Assuntos
Rim/diagnóstico por imagem , Circulação Renal/fisiologia , Adulto , Meios de Contraste , Feminino , Rejeição de Enxerto/diagnóstico por imagem , Humanos , Córtex Renal/diagnóstico por imagem , Falência Renal Crônica/diagnóstico por imagem , Medula Renal/diagnóstico por imagem , Transplante de Rim , Masculino , Ultrassonografia/métodos
13.
Vasa ; 32(4): 205-8, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14694769

RESUMO

BACKGROUND: In chronic venous insufficiency (CVI) III typical changes of skin, subcutaneous tissue, fascia and muscle can be found. It was believed, that the thickening of the fascia is irreversible and it has been postulated that the degeneration of muscles is causative for the persistence of recalcitrant leg ulcers. PATIENTS AND METHODS: By computed tomography (CT) and magnetic resonance imaging (MRI) 8 patients with therapy resistant venous ulcers were examined. Changes of fascia and muscles were determined preoperatively and 12 months after successful shave therapy. RESULTS: By CT a thinning of the preoperatively thickened fascia could be demonstrated in all patients one year after surgery. Before shave therapy MRI showed that the fascia was not only thickened and blurred, but also had fluid accumulations perifascial. 12 months after therapy the fascia was thinner and sharply demarcated. The fluid was either absent or distinctively reduced. Referring to the thickness of fascia an average decrease of 0.084 cm (0.03-0.17 cm) was observed. Before surgery the muscles showed a fatty degeneration as a sign of atrophy; with CT and MRI no changes could be demonstrated after one year in all patients. CONCLUSION: The results after one year demonstrate for the first time, that the changes of the fascia in CVI III are reversible and that there is no direct correlation between the degeneration of muscles and the persistence of venous leg ulcers.


Assuntos
Desbridamento , Fáscia/patologia , Lipomatose/cirurgia , Músculo Esquelético/patologia , Complicações Pós-Operatórias/patologia , Esclerodermia Localizada/cirurgia , Úlcera Varicosa/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Lipomatose/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Recidiva , Esclerodermia Localizada/patologia , Transplante de Pele , Tomografia Computadorizada por Raios X , Cicatrização/fisiologia
15.
Acta Neuropathol ; 105(6): 570-80, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12664319

RESUMO

To determine the value of imaging procedures such as computer tomography (CT) and magnetic resonance imaging (MRI) of the head in providing additional information of forensic relevance, we examined 17 cadavers of human victims of gunshot wounds to the head. Three of the victims briefly survived the gunshot wound. The weapons involved were all guns with low muzzle energy (<550 J), i.e., handguns and low-velocity rifles. In the majority of cases ( n=15) a penetrating wound to the head was found, only two cases showed the bullet lodged in the brain. In some cases, imaging of the skull and brain was performed prior to autopsy; in others imaging took place after autopsy on the isolated, formalin-fixed brain. The imaging findings were correlated with the criminological data and the results of macroscopic and microscopic examination of the brain. The findings on the bony structures of the head provided imaging criteria for differentiation between entrance and exit of the gunshot wounds, which corresponded to the forensic pathological findings at autopsy. CT scans and MRI of the cerebral parenchyma revealed lanes of opaque bone and missile fragments along the course of the missile, which allowed recognition of the missile track in 3D reconstruction. Biometric reconstruction allowed easy determination of the angle of the missile track in all three planes. Examination of the parenchymal structures and imaging of the isolated, formalin-fixed brain enabled tracking of the missile path directly along the zone of destruction as well as demonstration of secondary changes such as air bubbles along the bullet course, hemorrhage and edema. The significance of a translucent zone surrounding the missile track in several cases remains unclear; it probably represents tissue destruction secondary to temporary cavitation. The imaging procedures described here allowed excellent documentation of in situ conditions, while the storing of data enabled biometric reconstruction for determination of the angle of trajectory, of entrance and exit wounds, and the extent of tissue damage along the missile track and, possibly, in the zone of temporary cavitation.


Assuntos
Documentação , Medicina Legal , Cabeça , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Ferimentos por Arma de Fogo/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Autopsia/métodos , Biometria/métodos , Lesões Encefálicas/patologia , Feminino , Armas de Fogo/estatística & dados numéricos , Traumatismos Cranianos Penetrantes/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Mudanças Depois da Morte , Fraturas Cranianas/patologia
16.
Stud Health Technol Inform ; 81: 584-6, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11317814

RESUMO

In complex surgery, medical modeling has become an accepted tool for diagnosis, simulation and the planning of surgical interventions [1]. However, the question concerning the accuracy of the model, i.e. the equivalence between the model itself on the one hand and the original anatomical situation on the other hand, remains unanswererd in the current literature.


Assuntos
Imageamento Tridimensional , Ilustração Médica , Modelos Anatômicos , Tomografia Computadorizada por Raios X , Interface Usuário-Computador , Cefalometria , Humanos , Reprodutibilidade dos Testes
17.
Invest Radiol ; 36(5): 266-75, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11323514

RESUMO

RATIONALE AND OBJECTIVES: To determine the clinical dose of gadoteridol (ProHance, Bracco-Byk Gulden) to use for the assessment of blood-brain barrier breakdown on low-field magnetic resonance (MR) scanners that corresponds to a standard dose of gadoteridol on high-field MR scanners. METHODS: This prospective study was carried out at four centers. A total of 138 patients with suspected or known brain diseases underwent a routine head scan comprising precontrast T2-weighted turbo spin-echo and T1-weighted spin-echo sequences on a 1.5-T MR scanner. After administration of a standard dose of 0.1 mmol/kg gadoteridol, the T1-weighted scan was repeated after a delay of 15 to 20 minutes. For continuing the examination on a 0.2-T MR scanner (Magnetom OPEN, Siemens), a standard-dose T1 spin-echo sequence was started within 30 to 50 minutes of the first injection. Then two additional T1-weighted low-field sequences were each started 5 minutes after two additional doses of 0.1 mmol/kg gadoteridol. Eighty patients with enhancing lesions underwent an intraindividual comparison. Evaluation of the overall numbers of lesions detected and of lesion size and character was performed on-site as well as off-site by two independent readers. RESULTS: The single-dose, low-field sequence detected significantly fewer enhancing lesions (80/95 lesions; P < 0.05), particularly metastases and infarctions, than did the standard-dose, high-field sequence. No statistically relevant differences (reader 1: P = 1; reader 2: P = 0.8) were found between the double- and triple-dose, low-field sequences and the standard-dose, high-field sequence. Primary brain tumors were detected by all postcontrast sequences irrespective of the dose. CONCLUSIONS: At low field, the clinically equivalent dose to 0.1 mmol/kg gadoteridol at high field is 0.2 mmol/kg. A dose of 0.1 mmol/kg gadoteridol is less effective and cannot be recommended for use on extremely low-field scanners.


Assuntos
Encefalopatias/patologia , Meios de Contraste/administração & dosagem , Compostos Heterocíclicos/administração & dosagem , Imageamento por Ressonância Magnética , Compostos Organometálicos/administração & dosagem , Adulto , Idoso , Feminino , Gadolínio , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
18.
Eur Radiol ; 11(2): 187-92, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11218012

RESUMO

The aim of this study was to determine the efficacy of Gd-BOPTA-enhanced MRI in liver lesion detection in comparison with unenhanced MRI and dynamic CT. The image sets of 148 of 151 patients enrolled in a multicenter German phase-III trial were evaluated by two independent radiologists unaffiliated with the investigating centers. Patients underwent a routine MRI protocol comprising T2- and T1-weighted spin-echo and T1-weighted gradient-echo (GE) sequences pre and 1 h post 0.1 mmol/kg Gd-BOPTA (Bracco-Byk Gulden, Konstanz, Germany). Additionally, a serial T1-weighted GE scan was performed after administration of the first half of the dose. All patients underwent dynamic contrast-enhanced CT. The evaluation was performed with regard to the number and size of lesions detected per patient by each modality or sequence. Furthermore, all pre CM and pre + post CM image sets were analyzed for number of lesions per patient. Both readers detected significantly more lesions in the contrast-enhanced image set compared with the unenhanced image set (32 and 39 %, respectively; p < 0.0001). While contrast-enhanced CT detected a similar number of lesions to unenhanced MRI, it was clearly inferior to contrast-enhanced MRI (reader 1: p = 0.0117; reader 2: p = 0.0225). Of the T1-weighted scans performed, the dynamic and late T1-weighted GE exams contributed most to the increased lesion detection rate (reader 1: p = 0.0007; reader 2: p = 0.0037). The size of the smallest lesion detected by means of MRI was significantly larger in the pre-CM image sets than in the pre + post CM image sets (reader 1: p = 0.001; reader 2: p < 0.0001). Gd-BOPTA-enhanced MRI detected significantly smaller lesions than contrast-enhanced CT (reader 1: p = 0.0117; reader 2: p = 0.0925). Gd-BOPTA-enhanced MR imaging improves liver lesion detection significantly over unenhanced MRI and dynamic CT.


Assuntos
Meios de Contraste/administração & dosagem , Imagem Ecoplanar/métodos , Gadolínio , Neoplasias Hepáticas/diagnóstico , Meglumina/administração & dosagem , Compostos Organometálicos/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Gadolínio/administração & dosagem , Humanos , Injeções Intravenosas , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
19.
Eur J Radiol ; 30(1): 43-53, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10389012

RESUMO

OBJECTIVE: To evaluate the diagnostic quality of an open whole-body low-field MRI scanner compared to high-field scanners. MATERIALS AND METHODS: Over a period of 3 months, 401 patients with diseases of the kidney (n = 78), the shoulder (n = 122), the spine (n = 105) and the cerebrum (n = 96) were prospectively evaluated in four participating centers. They all underwent clinical evaluation, low-field and high-field MRI examination and surgical or follow-up confirmation of diagnosis. Clinical, histopathologic, high-field and low-field MRI diagnoses were recorded in standardized questionnaires that were centrally evaluated. Statistical evaluation comprised two parts: ROC analysis assessed accuracy of MRI and clinical diagnoses; furthermore rates of concordance of high- and low-field MRI diagnosis were calculated. RESULTS: We found no statistically relevant difference in high-field MRI diagnosis compared to low-field MRI diagnostic accuracy measured by clinical or surgical gold standard in three of the four regions examined; in cerebral examinations there was a small yet significant advantage for the high-field systems (P = 0.01). CONCLUSION: We conclude that the open low-field scanner we evaluated using clinical and surgical gold standard as reference is able to achieve comparable diagnostic accuracy compared to high-field scanners at lower costs and greater patient comfort. Limitations due to field strength (signal-to-noise ratio, resolution, scan time) seem to be relevant only in a very small number of cases that warrant high-field examination.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Encefalopatias/diagnóstico , Estudos de Avaliação como Assunto , Feminino , Humanos , Artropatias/diagnóstico , Neoplasias Renais/diagnóstico , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Ombro , Doenças da Coluna Vertebral/diagnóstico
20.
Acta Radiol ; 40(4): 429-35, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10394873

RESUMO

PURPOSE: To evaluate the safety and diagnostic efficacy of two different doses of ferric ammonium citrate as a paramagnetic oral contrast agent for MR imaging of the upper abdomen. MATERIAL AND METHODS: Ninety-nine adult patients referred for MR imaging for a known or suspected upper abdominal pathology were included in this randomized multicenter double-blind clinical trial. Imaging was performed with spin-echo (T1- and T2-weighted) and gradient-echo (T1-weighted) techniques before and after administration of either 1200 mg or 2400 mg of ferric ammonium citrate dissolved in 600 ml of water. Safety analysis included monitoring of vital signs, assessment of adverse events, and laboratory testing. Efficacy with regard to organ distension, contrast distribution, bowel enhancement and delineation of adjacent structures was graded qualitatively. RESULTS: No serious adverse events were reported for either of the two concentrations. A total of 31 minor side effects were noted, of which significantly more occurred in the higher dose group (p<0.01). The diagnostic confidence in defining or excluding disease was graded as better after contrast administration for 48% of all images. Marked or moderate enhancement of the upper gastrointestinal tract was achieved at both doses in 69.5% of cases with no evident difference between the two doses. The higher dose tended to show better results in terms of the contrast assessment parameters. CONCLUSION: Ferric ammonium citrate is a safe and effective oral contrast agent for MR imaging of the upper abdomen at two different dose levels. The higher dose showed a tendency toward better imaging results while the lower dose caused significantly fewer side effects. Therefore the 1200 mg dose can be recommended in view of the risk-to-benefit ratio.


Assuntos
Meios de Contraste , Sistema Digestório/patologia , Compostos Férricos , Gastroenteropatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Compostos de Amônio Quaternário , Abdome , Administração Oral , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Método Duplo-Cego , Feminino , Compostos Férricos/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Compostos de Amônio Quaternário/administração & dosagem , Reprodutibilidade dos Testes , Segurança
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...