Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Stud Health Technol Inform ; 302: 819-820, 2023 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-37203504

RESUMO

To classify sentences in cardiovascular German doctor's letters into eleven section categories, we used pattern-exploiting training, a prompt-based method for text classification in few-shot learning scenarios (20, 50 and 100 instances per class) using language models with various pre-training approaches evaluated on CARDIO:DE, a freely available German clinical routine corpus. Prompting improves results by 5-28% accuracy compared to traditional methods, reducing manual annotation efforts and computational costs in a clinical setting.


Assuntos
Idioma , Aprendizado de Máquina , Processamento de Linguagem Natural , Aprendizagem
2.
Sci Data ; 10(1): 207, 2023 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-37059736

RESUMO

We present CARDIO:DE, the first freely available and distributable large German clinical corpus from the cardiovascular domain. CARDIO:DE encompasses 500 clinical routine German doctor's letters from Heidelberg University Hospital, which were manually annotated. Our prospective study design complies well with current data protection regulations and allows us to keep the original structure of clinical documents consistent. In order to ease access to our corpus, we manually de-identified all letters. To enable various information extraction tasks the temporal information in the documents was preserved. We added two high-quality manual annotation layers to CARDIO:DE, (1) medication information and (2) CDA-compliant section classes. To the best of our knowledge, CARDIO:DE is the first freely available and distributable German clinical corpus in the cardiovascular domain. In summary, our corpus offers unique opportunities for collaborative and reproducible research on natural language processing models for German clinical texts.

3.
ESC Heart Fail ; 10(2): 1003-1012, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36514259

RESUMO

AIMS: Wildtype transthyretin amyloid cardiomyopathy is an under-recognized cause of heart failure in elderly patients. Transcatheter tricuspid valve repair is a newly emerging therapeutic option for severe tricuspid regurgitation (TR). We present first insights into safety and possible benefits of this procedure in patients with cardiac amyloidosis. METHODS AND RESULTS: Eight patients with cardiac non-hereditary (wildtype) transthyretin (ATTRwt) amyloidosis and severe to torrential TR, undergoing successful transcatheter tricuspid valve repair, were included in the analysis and compared to a control group of 21 patients without cardiac amyloidosis. All patients presented with an advanced stage of amyloid cardiomyopathy. Primary endpoint was reduction in TR at 3 months follow-up. Secondary endpoints were feasibility, safety, hospitalization or death, clinical improvement, cardiac biomarkers, and structural and functional right heart parameter obtained by echocardiography. Transcatheter tricuspid valve repair resulted in a significant reduction of TR (IV to II, P = 0.008) in all eight patients with cardiac amyloidosis (100%). Device success (amyloidosis 75% vs. control group 86%, P = 0.597) and overall probability of hospitalization or death (amyloidosis 13% vs. control group 25%, P = 0.646) were similar compared with those in the control group at 3 months follow-up. Transcatheter tricuspid valve repair led to an improvement of New York Heart Association functional class (P = 0.031) and 6 min walking distance (from 313 ± 118 to 337 ± 106, P = 0.012). TR reduction in amyloidosis patients was less extensive compared with that in control group (TR-reduction 1.6 ± 0.3, P = 0.008 vs. control group 2.3 ± 0.3, P < 0.0001). Furthermore, these patients showed no significant improvement of structural right heart parameters. CONCLUSIONS: Transcatheter tricuspid valve repair is a safe and feasible new treatment option in patients with amyloid cardiomyopathy and has the potential to improve TR-grade and clinical status. However, the benefit appears to be less pronounced compared with patients without cardiac amyloidosis.


Assuntos
Amiloidose , Cateterismo Cardíaco , Insuficiência da Valva Tricúspide , Valva Tricúspide , Idoso , Humanos , Amiloidose/complicações , Amiloidose/diagnóstico , Amiloidose/cirurgia , Cateterismo Cardíaco/métodos , Pré-Albumina , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia
4.
J Cardiovasc Dev Dis ; 9(9)2022 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-36135430

RESUMO

Objective: Little is known about the fate of bypass grafts to the right coronary system. To investigate the long-term patency of venous bypass grafts directed to the right coronary artery (RCA) based on postoperative angiograms and to identify predictors of graft occlusion. Methods: In this single-center study, all patients who underwent coronary angiography from 2005 to 2021 after previously undergoing isolated coronary artery bypass grafting (CABG) were included. The primary endpoint was graft occlusion over a median follow-up of 9.1 years. Results: Among a total of 1106 patients (17.0% women, 64 (57−71) years median age), 289 (26.1%) received a sequential vein graft and 798 (72.2%) a single graft. Multivariate regression revealed age (HR 1.019, CI 95% 1.007−1.032), the urgency of CABG (HR 1.355, CI 95% 1.108−1.656), and severely impaired left ventricular function (HR 1.883, CI 95% 1.290−2.748), but not gender and chronic total occlusion (CTO) as predictive factors for graft occlusion. Single conduits were found to be a predictor of graft patency (HR 0.575 CI 95% 0.449−0.737). The angiographic outcome showed an overall 10-year freedom from graft occlusion of 73.4% ± 1.6%. The 5-year (10-year) freedom from graft occlusion was 76.9% ± 2.8% (57.8% ± 4.0%) for sequential grafts and 90.4% ± 1.1% (77.8% ± 1.7%) for single grafts (log-rank p < 0.001). Conclusions: In symptomatic patients with renewed angiography, venous bypass grafting of the RCA showed acceptable long-term patency rates. Single bypass grafting of the RCA was superior to sequential grafting, which needs to be further investigated.

5.
Life (Basel) ; 12(3)2022 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-35330095

RESUMO

Transcatheter edge-to-edge repair (TEER) using the MitraClip™ device has been established as a suitable alternative to mitral valve surgery in patients with severe mitral regurgitation (MR) and high or prohibitive surgical risk. Only limited information regarding the impact of TEER on ventricular arrhythmias (VA) has been reported. The aim of the present study was to assess the impact of TEER using the MitraClipTM device on the burden of VA and ICD (Implantable Cardioverter Defibrillator) therapies. Among 600 MitraClipTM implantations performed in our clinic between September 2009 and October 2018, we identified 86 patients with successful TEER and an active implantable cardiac device (pacemaker, ICD, CRT-P/D (Cardiac Resynchronization Therapy-Pacemaker/Defibrillator)) eligible for retrospective VA analyses. These patients presented with mainly functional MR (81.4%) and severely reduced left ventricular ejection fraction (mean LVEF 22.1% ± 10.3%). The observation period comprised 456 ± 313 days before and 424 ± 287 days after TEER. The burden of ventricular arrhythmias (sustained ventricular tachycardia (sVT) and ventricular fibrillation (VF)) was significantly reduced after TEER (0.85 ± 3.47 vs. 0.43 ± 2.03 events per patient per month, p = 0.01). Furthermore, the rate of ICD therapies (anti-tachycardia pacing (ATP) and ICD shock) decreased significantly after MitraClipTM implantation (1.0 ± 3.87 vs. 0.32 ± 1.41, p = 0.014). However, reduction of VA burden did not result in improved two-year survival in this patient cohort with severely reduced LVEF. Mitral valve TEER using the MitraClip™ device was associated with a significant reduction of ventricular arrhythmias and ICD therapies.

6.
ESC Heart Fail ; 9(2): 853-865, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35170230

RESUMO

AIMS: Mitral valve transcatheter edge-to-edge repair (TEER) has been established as a suitable alternative to mitral valve surgery in patients with severe mitral regurgitation (MR) and high surgical risk. The PASCAL system represents a novel device, potentially augmenting the toolkit for TEER. The aim of this study was to assess and compare short and 1 year safety and efficacy of the PASCAL and MitraClip systems for TEER. METHODS AND RESULTS: Procedural, short, and 1 year outcomes of a 1:2 propensity-matched cohort including 41 PASCAL and 82 MitraClip cases were investigated. Matching was based on clinical, laboratory, echocardiographic, and functional characteristics. The primary endpoints assessed were procedural success [as defined by the Mitral Valve Academy Research Consortium (MVARC)], residual MR, functional class, and a composite endpoint comprising death, heart failure hospitalization, and mitral valve re-intervention. We found for the PASCAL and the matched MitraClip cohort no significant differences in MVARC defined technical (90.2% vs. 95.1%, P = 0.44), device (90.2% vs. 89.0%, P = 1.0), or procedural (87.8% vs. 80.5%, P = 0.45) success rates. Accordingly, the overall MR reduction and improvement in New York Heart Association (NYHA) class were comparable (1 year follow-up: MR ≤ 2 95% vs. 93.6%, P = 1.0; NYHA ≤ 2 57.1% vs. 66.7%, P = 0.59). The composite outcome revealed no statistically significant difference between both devices (1 year follow-up: 31.7% vs. 37.8%, P = 0.55). Interestingly, we found at both short and 1 year follow-up a significantly higher rate of patients with none or trace MR in the PASCAL-treated cohort (short follow-up: 17.9% vs. 0%, P = 0.0081; 1 year follow-up: 25% vs. 0%, P = 0.0016). Conversely, the rate of aborted device implantations due to an elevated transmitral gradient was higher in PASCAL interventions (9.8% vs. 1.2%, P = 0.04). CONCLUSIONS: Transcatheter edge-to-edge repair using the PASCAL or MitraClip device results in favourable and comparable outcomes regarding safety, efficacy, and clinical improvement after 1 year.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
7.
Digit Health ; 7: 20552076211057662, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34868618

RESUMO

OBJECTIVE: A vast amount of medical data is still stored in unstructured text documents. We present an automated method of information extraction from German unstructured clinical routine data from the cardiology domain enabling their usage in state-of-the-art data-driven deep learning projects. METHODS: We evaluated pre-trained language models to extract a set of 12 cardiovascular concepts in German discharge letters. We compared three bidirectional encoder representations from transformers pre-trained on different corpora and fine-tuned them on the task of cardiovascular concept extraction using 204 discharge letters manually annotated by cardiologists at the University Hospital Heidelberg. We compared our results with traditional machine learning methods based on a long short-term memory network and a conditional random field. RESULTS: Our best performing model, based on publicly available German pre-trained bidirectional encoder representations from the transformer model, achieved a token-wise micro-average F1-score of 86% and outperformed the baseline by at least 6%. Moreover, this approach achieved the best trade-off between precision (positive predictive value) and recall (sensitivity). CONCLUSION: Our results show the applicability of state-of-the-art deep learning methods using pre-trained language models for the task of cardiovascular concept extraction using limited training data. This minimizes annotation efforts, which are currently the bottleneck of any application of data-driven deep learning projects in the clinical domain for German and many other European languages.

8.
ESC Heart Fail ; 8(6): 4617-4625, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34498422

RESUMO

AIM: Percutaneous mitral valve repair (PMVR) via MitraClip implantation is a therapeutic option for severe mitral regurgitation (MR) in advanced stages of heart failure (HF). However, progressive left ventricular dilation in these patients may lead to recurrent MR after PMVR and consequent re-do MitraClip implantation. Here, we describe the characteristics and outcomes of this clinical scenario. METHODS AND RESULTS: Patients with systolic HF and functional MR undergoing a re-do MitraClip procedure were retrospectively analysed. Inclusion criteria were age ≥18 years, technical, device and procedural success at first MitraClip procedure, functional MR and systolic HF with an ejection fraction (EF) of <45%. Seventeen out of 684 patients undergoing PMVR with the MitraClip device at our institution between September 2009 and July 2019 were included. All patients displayed advanced HF with an EF of 20% (±9.9) and highly elevated N-terminal pro-brain natriuretic peptide. Technical success of the re-do MitraClip procedure was 100%, whereas procedural and device success were only achieved in 11 patients (65%). Unsuccessful re-do procedures were related to lower EF and implantation of more than one clip at initial procedure. However, despite reduction in MR grade and no occurrence of significant mitral stenosis after the procedure, the mortality during 12 months follow-up remained high (8 of 17; 47%). CONCLUSIONS: In a cohort of patients with advanced HF undergoing PMVR, re-do MitraClip procedure was feasible, but procedural success was unsatisfactory and morbidity and mortality remained high, possibly reflecting the advanced stage of HF in these patients.


Assuntos
Insuficiência Cardíaca Sistólica , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Adolescente , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
10.
ESC Heart Fail ; 8(5): 3530-3538, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34448541

RESUMO

AIMS: We investigated short and mid-term safety and efficacy of the PASCAL system for percutaneous mitral valve repair (PMVr) in severe mitral regurgitation (MR) in an all-comer population. METHODS AND RESULTS: In the first consecutive 41 patients undergoing PMVr using the PASCAL system in our centre, procedural success and safety were assessed. Efficacy in improving MR and functional class were evaluated. Median patient age was 74 years, 58.5% were male patients, and median European System for Cardiac Operative Risk Evaluation Score II was 5.1%. All patients suffered from severe MR with 59% functional MR, 29% degenerative MR, and 12% of mixed aetiology MR. The technical success rate was 90%, limited by four cases where PASCAL implantation was aborted due to a prohibitive mitral gradient. On average, 1.16 PASCAL devices per patient were implanted. All patients successfully implanted with a PASCAL device were discharged with MR grade ≤ 2 and 79% with MR grade ≤ 1. Mean follow-up was 8.7 ± 4.9 months. Ninety-seven per cent of patients remained at MR ≤ 2 at follow-up, which translated into a significantly improved New York Heart Association functional class as well as a significant reduction of systolic pulmonary artery pressure and brain natriuretic peptide levels. The procedure-related rate for major adverse events was 3%. Neither early nor late single-leaflet detachment was found. In one patient, air embolism occurred, resulting in modification of the PASCAL instructions for use. CONCLUSIONS: Percutaneous mitral valve repair using PASCAL in a real-world, all-comer population was feasible and safe, resulting in a significant mid-term reduction of MR with persistent clinical improvement.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
11.
Eur J Clin Invest ; 51(6): e13473, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33326601

RESUMO

BACKGROUND: Percutaneous mitral valve repair (PMVR) is a therapeutic option for severe mitral regurgitation (MR) in patients with heart failure due to differential aetiologies. However, only little is known about the safety and efficacy of this procedure in patients with amyloid cardiomyopathy. METHODS: Five patients with cardiac amyloidosis and moderate to severe or severe MR undergoing PMVR were analysed retrospectively and compared to seven patients with cardiac amyloidosis and severe MR without intervention. Clinical and functional data, renal function and cardiac biomarkers as well as established risk scores for cardiac amyloidosis were assessed. Primary endpoint was the reduction in MR one year after PMVR. Secondary endpoints were safety, overall mortality after 12 months compared with the control group, as well as changes in clinical and functional parameters. RESULTS: Amyloidosis risk assessment documented amyloid cardiomyopathy at an advanced stage in all patients. Procedural, technical and device success of PMVR were all 100% and residual MR remained mild to moderate at 12 months follow-up (P = .038 vs before PMVR). Differences in survival compared with the control (no PMVR) group pointed to a possible survival benefit in the PMVR group (P = .02). CONCLUSION: PMVR is a feasible and safe procedure in patients with cardiac amyloidosis and might carry a possible survival benefit in this patient group.


Assuntos
Amiloidose/fisiopatologia , Cateterismo Cardíaco/métodos , Cardiomiopatias/fisiopatologia , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Amiloidose/complicações , Cardiomiopatias/complicações , Feminino , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento
12.
ESC Heart Fail ; 7(6): 3891-3900, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33107214

RESUMO

AIMS: Mitral valve regurgitation (MR) is common in patients with advanced heart failure (HF). Percutaneous mitral valve repair (PMVR) via MitraClip (MC) has emerged as a feasible treatment strategy for these high-risk patients. However, as HF often further progresses, there is a frequent need for left ventricular assist device (LVAD) implantation in these patients. We aimed to investigate whether prior MC implantation affects the subsequent LVAD implantation and outcome. METHODS AND RESULTS: Thirty-seven patients with advanced HF and significant MR who underwent LVAD implantation were retrospectively analysed. Follow-up data were collected at 1 year after LVAD implantation. Primary endpoint was all-cause mortality. Secondary endpoint included peri-operative parameters and clinical development depicted as New York Heart Association (NYHA) class and Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) level. Seventeen patients initially received a MC device (MC group), resulting in a significant reduction in MR grade. After MC, NYHA class and INTERMACS level further worsened, leading to subsequent LVAD implantation after a median time of 475 days in the MC group. At LVAD implantation, overall characteristics were comparable with those of the patients undergoing LVAD implantation without prior MC placement (no-MC group). Procedural data revealed a higher incidence of right ventricular (RV) failure needing mechanical RV assistance and a longer need for nitric oxide ventilation in the MC group after LVAD implantation. One-year survival was slightly better in the no-MC group compared with the MC group [41% (n = 7/17) vs. 65% (n = 13/20); P = 0.15], albeit event-free survival was comparable between both groups, MC and no-MC. CONCLUSIONS: LVAD implantation after MC is feasible and safe. However, in patients with advanced HF and severe MR, PMVR may only delay a needed LVAD implantation and thereby lead to poorer peri-operative RV function and impaired outcome. Arguably, these patients might benefit from the timely management of advanced HF by the means of early LVAD implantation or heart transplantation.

13.
Clin Res Cardiol ; 108(4): 375-387, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30191296

RESUMO

BACKGROUND: Percutaneous mitral valve repair (PMVR) via MitraClip implantation is a therapeutic option for high-risk or non-surgical candidates with severe mitral regurgitation (MR) and advanced stages of heart failure (HF). However, these patients have a high mortality despite PMVR, and predictors for outcomes are not well established. Here, we evaluated invasive hemodynamics, echocardiography parameters, and biomarkers to predict outcomes after PMVR in severe HF patients. METHODS: Patients with reduced ejection fraction (EF) and severe and moderate-to-severe MR undergoing PMVR at our centre between September 2009 and January 2016 were analysed retrospectively. Inclusion criteria were: left ventricular EF < 45%, preoperative right heart catheterization, successful MitraClip deployment ("technical success"), and follow-up for at least 1 year after the procedure. Data from preoperative right heart catheterization, echocardiography, and biomarkers were assessed. Primary endpoint was all-cause mortality at 1 year after PMVR. We performed univariate and multivariate Cox regression analyses and generated a risk score to predict outcomes. RESULTS: Of 174 patients with PMVR and severe HF, 79.9% had functional MR. Mean EF was 25% (17.2; 30.7) and advanced New York Heart Association functional class was prevalent (class II: 13%; class III: 70%; and class IV: 17%). The cumulative incidences of all-cause death were 6.9% and 17.8% at 30 days and 1 year, respectively. In the Cox multivariate model, high-sensitive troponin T [hsTnT; hazard ratio (HR) 1.01; confidence interval (CI) 1.01-1.02; p < 0.0001] and mixed venous O2-saturation (HR 0.92; CI 0.89-0.96; p < 0.0001) were found to significantly and independently predict outcomes. A simple risk score including these two parameters was sufficient to discriminate between low- and high-risk patients (HR 7.22; CI 3.4-15.5; p < 0.001). CONCLUSION: In a cohort of patients with severe HF undergoing PMVR, patients with elevated hsTnT and reduced mixed venous O2-saturation carried the worst prognosis. A simple risk score including these two parameters may improve patient selection and outcomes after PMVR.


Assuntos
Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/fisiopatologia , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica/fisiologia , Insuficiência da Valva Mitral/cirurgia , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Troponina T/sangue , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença
14.
J Interv Cardiol ; 31(6): 885-890, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30397939

RESUMO

BACKGROUND: To date, there are no guidelines recommending a specific prophylactic antibiotic treatment in transcatheter aortic valve replacement (TAVR). The aim of this study is to evaluate clinical data after TAVR with different periprocedural antibiotic regimens. METHODS: In May 2015 the institutional rules for periprocedural antibiotic prophylaxis were changed from 3 days to 1 day. Thus, a total of 450 consecutive TAVR patients between February 2014 and June 2016 were classified into two intention-to-treat groups: patients receiving a 1-day Cefuroxime prophylaxis (N = 225); patients receiving a 3-day Cefuroxime prophylaxis (N = 225). RESULTS: One-day Cefuroxime regimen was not associated with shorter hospitalization (3-day Cefuroxime 9 ± 4.7 vs 1-day Cefuroxime 8.9 ± 4.0; P = 0.87). Incidence of diarrhea (26.2% vs 18.2%; P = 0.04) and Clostridium difficile infections (4% vs 0.4%; P = 0.01) were significantly higher in the 3-day group. No endocarditis was registered after 1 year follow-up. There was no difference in 30-day overall mortality rate, major vascular complications, bleeding complications, pacemaker-implantation rate, paravalvular regurgitation, or acute kidney injury between patients groups. CONCLUSION: Three-day Cefuroxime prophylaxis does not seem to be advantageous compared to a shorter 1-day regimen, but even shows a significantly higher incidence of diarrhea and Clostridium difficile infection.


Assuntos
Antibacterianos/administração & dosagem , Antibioticoprofilaxia/métodos , Cefuroxima/administração & dosagem , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/efeitos adversos , Antibioticoprofilaxia/efeitos adversos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Cefuroxima/efeitos adversos , Feminino , Mortalidade Hospitalar , Humanos , Análise de Intenção de Tratamento , Tempo de Internação/estatística & dados numéricos , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
15.
ESC Heart Fail ; 5(5): 892-901, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30058757

RESUMO

AIMS: Functional mitral regurgitation is complicating end-stage heart failure and potential heart transplantation by increasing pulmonary artery pressures. The aim of the present study was to investigate feasibility and haemodynamic effects of percutaneous mitral valve edge-to-edge repair using the MitraClip™ device in patients with end-stage heart failure awaiting heart transplantation. METHODS AND RESULTS: In this retrospective study, we identified nine patients suffering from end-stage heart failure listed for heart transplantation in whom moderate-severe or severe functional mitral regurgitation was recognized and treated with percutaneous mitral valve edge-to-edge repair. Twenty-two patients listed for heart transplantation and presenting with moderate-severe or severe functional mitral regurgitation treated in the pre-MitraClip™ era served as controls. Patients were analysed at two separate time points: MitraClip™ group: pre-procedure and post-procedure (follow-up: 215 ± 53 days) and control group: study entry with recognition of moderate-severe or severe functional mitral regurgitation (follow-up: 197 ± 47 days). Percutaneous mitral valve edge-to-edge repair with the MitraClip™ was feasible and safe in our high-risk end-stage heart failure population. The intervention resulted in significant reduction of mitral regurgitation (grade 3.0 [0.5] to 1.5 [0.5]; P = 0.009), left atrial diameter (51 mm [16] to 49 mm [4]; follow-up MitraClip™ vs. control group P = 0.0497), pulmonary artery pressures (sPA 50 mmHg [15] to 45 mmHg [10]; P = 0.02; mPA 34 mmHg [8] to 30 mmHg [10]; P = 0.02), and New York Heart Association class (3.5 [1.0] to 3.0 [0.5]; P = 0.01) and improved mixed-venous oxygen saturation (57% [11] to 55% [7]; follow-up MitraClip™ vs. control group P = 0.02). No changes in the control group were observed. CONCLUSIONS: MitraClip™ implantation as 'bridge-to-transplant' strategy in patients with end-stage heart failure and severe functional mitral regurgitation awaiting heart transplantation is feasible and appears to result in favourable haemodynamic effects.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Hemodinâmica/fisiologia , Valva Mitral/cirurgia , Listas de Espera , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Desenho de Prótese , Implantação de Prótese/métodos , Estudos Retrospectivos , Resultado do Tratamento
16.
Clin Res Cardiol ; 107(9): 799-806, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29644411

RESUMO

AIMS: Antithrombotic therapy after transcatheter aortic valve implantation (TAVI) is highly controversial and guideline recommendations are not evidence based. We assessed efficacy and safety of non-vitamin K antagonist oral anticoagulant (NOAC) monotherapy in patients with concomitant indications for OAC undergoing TAVI. METHODS: Among more than 1300 TAVI patients since 2008, 154 patients were identified who received postinterventional NOAC monotherapy. Outcomes were compared to 172 patients treated with vitamin K antagonist (VKA) monotherapy. Thromboembolic as well as bleeding complications were analysed for 6 months after TAVI. RESULTS: Despite high CHA2DS2-Vasc (4.6 ± 1.2), HEMORR2HAGES (4.7 ± 1.9) and HASBLED (2.7 ± 0.8) scores only three major/life-threatening bleedings and four thromboembolic events occurred after NOAC therapy had been initiated post-TAVI. 12 patients (7.8%) died within 6 months after the procedure. Compared to patients being treated with VKA monotherapy, analysis of a combined end-point of post-procedural death, stroke, embolism and severe bleeding revealed no significant differences (17/154 vs. 14/172; p = 0.45). CONCLUSIONS: The results of this study suggest that NOAC therapy without additional antiplatelet treatment is effective and safe in patients with concomitant indications for OAC undergoing TAVI.


Assuntos
Anticoagulantes/administração & dosagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cuidados Pré-Operatórios/métodos , Tromboembolia/prevenção & controle , Terapia Trombolítica/métodos , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Estudos Retrospectivos , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Vitamina K/antagonistas & inibidores
17.
Eur J Heart Fail ; 20(3): 598-608, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28834079

RESUMO

AIMS: The aim of the present study was to assess the safety and efficacy of percutaneous mitral valve repair using the MitraClip™ device in patients with severely reduced systolic left ventricular (LV) function. METHODS AND RESULTS: Among 777 MitraClip™ implantations included in the German mitral valve registry, we identified 256 patients suffering from severely reduced LV function [ejection fraction (EF) <30%] in whom successful percutaneous mitral valve repair was performed. Procedural safety, efficacy, and 1-year outcome was compared with 241 patients with preserved LV function (EF >50%) and 280 patients presenting with an EF 30-50% prior to MitraClip™ therapy. High procedural success rates, low periprocedural complication rates, and low residual mitral regurgitation grades at discharge were achieved throughout all groups. In-hospital mortality was low and comparable in all groups. After 1 year, mortality rates were 24.2% (EF <30%), 17.3% (EF 30-50%), and 18.9% (EF >50%). Major adverse cardiac or cardiovascular event rates were 29.7% (EF <30%), 24.4% (EF 30-50%), and 23.5% (EF >50%). Procedural failure was the main predictor for mortality in EF <30% patients (hazard ratio 10.38; 95% CI 3.71-29.02). Improved clinical symptoms were observed in the majority of patients in all groups. Thus, 69.5% of EF <30% patients improved by one or more New York Heart Association functional class. Compared with patients with preserved LV function, this is a significantly larger proportion (EF >50%: 56.8%; P < 0.05). Moreover, quality of life, being very poor at baseline, improved distinctively in severe heart failure patients. CONCLUSION: In patients with severely reduced systolic LV function undergoing MitraClip™ therapy, procedural safety, efficacy, and clinical improvement after 1 year are comparable to patients with preserved LV function.


Assuntos
Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/complicações , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Sistema de Registros , Volume Sistólico/fisiologia , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Seguimentos , Alemanha/epidemiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Mortalidade Hospitalar , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/fisiopatologia , Qualidade de Vida , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
18.
EuroIntervention ; 12(17): 2058-2066, 2017 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-28433958

RESUMO

AIMS: We aimed to assess the efficacy and safety of vitamin K antagonist (VKA) monotherapy in atrial fibrillation (AF) patients undergoing transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: In 735 TAVIs since 2008 we identified 167 patients suffering from concomitant AF who received either VKA monotherapy (n=77), VKA plus single antiplatelet therapy (SAPT, n=41) or a triple anticoagulation regimen (n=49). Thromboembolic as well as bleeding complications were analysed for six months after TAVI. Only one minor bleeding and no thromboembolic events occurred after VKA therapy had been initiated post TAVI. Compared to patients being treated with additional either single or dual antiplatelet therapy, the incidence of major/life-threatening bleeding complications was significantly lower in the VKA mono group (0/77 [VKA mono] vs. 3/41 [VKA+SAPT; p=0.04] vs. 4/49 [triple anticoagulation; p=0.02]). Analysis of a combined endpoint of post-procedural death, stroke, embolism and major bleeding revealed a significant superiority of VKA monotherapy compared to VKA plus SAPT or DAPT, respectively (5/77 vs. 9/41 [p=0.02] vs. 14/49 [p=0.002]). CONCLUSIONS: VKA therapy without additional antiplatelet treatment is effective and safe in AF patients undergoing TAVI.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Femprocumona/uso terapêutico , Complicações Pós-Operatórias/prevenção & controle , Tromboembolia/prevenção & controle , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Alemanha/epidemiologia , Hemorragia/induzido quimicamente , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade
19.
J Interv Cardiol ; 30(1): 72-78, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27882613

RESUMO

OBJECTIVES: In this study, we compare procedural results of our first Evolut R (Medtronic, Minneapolis, MN, USA) implantations with the last CoreValve implantations. Main endpoints include paravalvular regurgitation, major vascular complications, stroke, and pacemaker implantation. BACKGROUND: The evolution of transcatheter aortic valve replacement (TAVR) was possible due to various technical improvements, leading to better periprocedural and long-term outcome. The newly designed Evolut R valve has the potential to further improve TAVR's performance. METHODS: We retrospectively analyzed our first 100 consecutive patients who received the Evolut R valve with the last 100 consecutive patients who received the CoreValve prosthesis between July 2013 and February 2016. Only patients treated with a 26 mm or 29 mm bioprosthesis were included. RESULTS: No significant differences in patient characteristics were noticed. Both angiography and echocardiography after TAVR showed significantly higher rates of "none or trace" regurgitation in the Evolut R group (angiography: 67% Evolut R vs. 29.3% CoreValve; P < 0.001; echocardiography: 68% Evolut R vs. 46.5% CoreValve; P < 0.05). No significant differences were seen in 30-day mortality (7% CoreValve vs. 1% Evolut R), stroke rates (3% CoreValve vs. 2% Evolut R), pacemaker implantation rates (24% CoreValve vs. 23% Evolut R), and major vascular complications (6% CoreValve vs. 1% Evolut R). Implantations were significantly higher with the Evolut R prosthesis. CONCLUSIONS: TAVR with the new Evolut R resulted in significantly lower paravalvular regurgitation. This may be due to redesigned cell geometry and higher precision during implantations, as well as the ability to resheath a malpositioned valve.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
20.
J Interv Cardiol ; 28(2): 190-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25728716

RESUMO

OBJECTIVES: We assessed efficacy and safety of the Gore(®) Septal Occluder (GSO) for patent foramen ovale (PFO) closure focusing on patients with challenging septal anatomies. BACKGROUND: In times of controversial discussion whether percutaneous PFO closure is superior to medical therapy for the prevention of recurrent embolic events after cryptogenic stroke, patient selection should mainly focus on individuals with an increased likelihood that the ischaemic event is related to the PFO. In this context, specific septal anatomies-such as the presence of an atrial septal aneurysm as well as long PFO tunnel anatomy-have been associated with a higher rate of cerebrovascular accidents. METHODS: The GSO was used for PFO closure in 41 patients presenting with either atrial septal aneurysm (ASA; 27/41; 65.9%) or long PFO tunnel (> 10 mm; 32/41; 78%). Seven of these patients even presented with a tunnel length ≥ 20 mm (7/41; 17.1%). Eighteen patients had both, long-tunnel anatomy and ASA (18/41; 43.9%). RESULTS: The GSO was successfully implanted in all cases. No procedural complications occurred and all patients were discharged the day after the procedure. Short-term follow-up, including TEE examination, in all patients was performed 37.6 ± 9.0 days after the procedure. Mid-term follow-up was performed after 192.7 ± 45.3 days. Later complications occurred in 7.3% (2 new onset atrial fibrillation, 1 device thrombus). Only 3 patients (7.3%) had more than trace residual shunts at 6-weeks follow-up. At 6-months follow-up, the complete closure rate was 95.1% (39/41). CONCLUSIONS: The Gore(®) Septal Occluder is an efficient device for patent foramen ovale closure in challenging anatomies, including long-tunnel PFOs and atrial septal aneurysms.


Assuntos
Cateterismo Cardíaco/instrumentação , Forame Oval Patente/cirurgia , Dispositivo para Oclusão Septal , Adulto , Desenho de Equipamento , Feminino , Seguimentos , Forame Oval Patente/complicações , Forame Oval Patente/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...