Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Clin Chem Lab Med ; 62(7): 1433-1437, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38176023

RESUMO

OBJECTIVES: The current study was designed to evaluate the analytical performance of the new Mindray highly sensitive cardiac troponin I (hs-cTnI) chemiluminescent immunoassay on Mindray CL-1200i, as a thorough validation of novel hs-cTnI methods is required before introduction into clinical practice. METHODS: The evaluation of the analytical performance of this hs-cTnI immunoassay encompassed the calculation of the limit of blank (LOB), limit of detection (LOD), functional sensitivity, imprecision, linearity, 99th percentile upper reference limit (URL) and concordance with another previously validated hs-cTnI chemiluminescent immunoassay. RESULTS: The LOB and LOD were 0.32 and 0.35 ng/L, whilst the functional sensitivity (expressed as cTnI value with <10 % imprecision), was 0.35 ng/L. The linearity was excellent throughout a wide range of clinically measurable values (r=1.00 between 0.8 and 9,726.9 ng/mL). The intra-assay, inter-assay and total imprecision were 1.1-1.3 %, 5.5-8.1 % and 5.6-8.2 %, respectively. The 99th percentile URL calculated using residual plasma from 246 ostensibly healthy blood donors was 9.2 ng/L (4.3 ng/L in women vs. 12.3 ng/L in men). The Spearman's correlation between Mindray hs-cTnI and Access hs-TnI was 0.97, with mean bias of 7.2 % (95 % CI, 2.6-11.9 %). CONCLUSIONS: Although we failed to confirm the very optimistic analytical characteristics previously reported for this method, our evaluation of the novel Mindray hs-cTnI immunoassay on CL-1200i demonstrated that the overall performance is comparable to that of other commercially available hs-cTnI techniques, making it a viable alternative to other methods.


Assuntos
Limite de Detecção , Troponina I , Humanos , Troponina I/sangue , Troponina I/análise , Imunoensaio/métodos , Imunoensaio/normas , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Medições Luminescentes/métodos , Medições Luminescentes/normas , Idoso , Reprodutibilidade dos Testes , Valores de Referência
2.
Semin Thromb Hemost ; 50(2): 275-283, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37327884

RESUMO

Platelets are central elements of hemostasis and also play a pivotal role in the pathogenesis of thrombosis in coronavirus disease 2019. This study was planned to investigate the effects of different severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) recombinant spike protein variants on platelet morphology and activation. Citrated whole blood collected from ostensibly healthy subjects was challenged with saline (control sample) and with 2 and 20 ng/mL final concentration of SARS-CoV-2 recombinant spike protein of Ancestral, Alpha, Delta, and Omicron variants. Platelet count was found to be decreased with all SARS-CoV-2 recombinant spike protein variants and concentrations tested, achieving the lowest values with 20 ng/mL Delta recombinant spike protein. The mean platelet volume increased in all samples irrespective of SARS-CoV-2 recombinant spike protein variants and concentrations tested, but especially using Delta and Alpha recombinant spike proteins. The values of both platelet function analyzer-200 collagen-adenosine diphosphate and collagen-epinephrine increased in all samples irrespective of SARS-CoV-2 recombinant spike protein variants and concentrations tested, and thus reflecting platelet exhaustion, and displaying again higher increases with Delta and Alpha recombinant spike proteins. Most samples where SARS-CoV-2 recombinant spike proteins were added were flagged as containing platelet clumps. Morphological analysis revealed the presence of a considerable number of activated platelets, platelet clumps, platelet-monocyte, and platelet-neutrophils aggregates, especially in samples spiked with Alpha and Delta recombinant spike proteins at 20 ng/mL. These results provide support to the evidence that SARS-CoV-2 is capable of activating platelets through its spike protein, though such effect varies depending on different spike protein variants.


Assuntos
COVID-19 , Glicoproteína da Espícula de Coronavírus , Humanos , SARS-CoV-2 , Colágeno
3.
Int J Mol Sci ; 24(16)2023 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-37628976

RESUMO

Studies investigating the potential role of circulating bile acids (BAs) as diagnostic biomarkers for cholangiocarcinoma (CCA) are sparse and existing data do not adjust for confounding variables. Furthermore, the mechanism by which BAs affect the expression of the oncogenic mucin 5AC (MUC5AC) has never been investigated. We performed a case-control study to characterise the profile of circulating BAs in patients with CCA (n = 68) and benign biliary disease (BBD, n = 48) with a validated liquid chromatography-tandem mass spectrometry technique. Odd ratios (OR) for CCA associations were calculated with multivariable logistic regression models based on a directed acyclic graph structure learning algorithm. The most promising BAs were then tested in an in vitro study to investigate their interplay in modulating MUC5AC expression. The total concentration of BAs was markedly higher in patients with CCA compared with BBD controls and accompanied by a shift in BAs profile toward a higher proportion of primary conjugated BAs (OR = 1.50, CI: 1.14 to 1.96, p = 0.003), especially taurochenodeoxycholic acid (TCDCA, OR = 42.29, CI: 3.54 to 504.63, p = 0.003) after multiple adjustments. Western blot analysis of secreted MUC5AC in human primary cholangiocytes treated with primary conjugated BAs or with TCDCA alone allowed us to identify a novel 230 kDa isoform, possibly representing a post-translationally modified MUC5AC specie.


Assuntos
Neoplasias dos Ductos Biliares , Colangiocarcinoma , Humanos , Ácidos e Sais Biliares , Mucina-5AC , Estudos de Casos e Controles , Ductos Biliares Intra-Hepáticos
4.
Int J Mol Sci ; 24(11)2023 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-37298324

RESUMO

This study investigated the biological effects on circulating monocytes after challenge with SARS-CoV-2 recombinant spike protein. Whole blood collected from seven ostensibly healthy healthcare workers was incubated for 15 min with 2 and 20 ng/mL final concentration of recombinant spike protein of Ancestral, Alpha, Delta, and Omicron variants. Samples were analyzed with Sysmex XN and DI-60 analyzers. Cellular complexity (i.e., the presence of granules, vacuoles and other cytoplasmic inclusions) increased in all samples challenged with the recombinant spike protein of the Ancestral, Alpha, and Delta variants, but not in those containing Omicron. The cellular content of nucleic acids was constantly decreased in most samples, achieving statistical significance in those containing 20 ng/mL of Alpha and Delta recombinant spike proteins. The heterogeneity of monocyte volumes significantly increased in all samples, achieving statistical significance in those containing 20 ng/mL of recombinant spike protein of the Ancestral, Alpha and Delta variants. The monocyte morphological abnormalities after spike protein challenge included dysmorphia, granulation, intense vacuolization, platelet phagocytosis, development of aberrant nuclei, and cytoplasmic extrusions. The SARS-CoV-2 spike protein triggers important monocyte morphological abnormalities, more evident in cells challenged with recombinant spike protein of the more clinically severe Alpha and Delta variants.


Assuntos
COVID-19 , Monócitos , Humanos , Glicoproteína da Espícula de Coronavírus/genética , SARS-CoV-2
5.
Biomedicines ; 11(1)2023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-36672627

RESUMO

Type 2 diabetes (T2D) is a multisystem disease that is the subject of many studies, but the earliest cause of the disease has yet to be elucidated. Mitochondrial impairment has been associated with diabetes in several tissues. To extend the association between T2D and mitochondrial impairment to blood cells, we investigated T2D-related changes in peripheral mononucleated blood cells' (PBMCs) mitochondrial function in two groups of women (CTRL vs. T2D; mean age: 54.1 ± 3.8 vs. 60.9 ± 4.8; mean BMI 25.6 ± 5.2 vs. 30.0 ± 5), together with a panel of blood biomarkers, anthropometric measurements and physiological parameters (VO2max and strength tests). Dual-energy X-ray absorptiometry (DXA) scan analysis, cardio-pulmonary exercise test and blood biomarkers confirmed hallmarks of diabetes in the T2D group. Mitochondrial function assays performed with high resolution respirometry highlighted a significant reduction of mitochondrial respiration in the ADP-stimulated state (OXPHOS; −30%, p = 0.006) and maximal non-coupled respiration (ET; −30%, p = 0.004) in PBMCs samples from the T2D group. The total glutathione antioxidant pool (GSHt) was significantly reduced (−38%: p = 0.04) in plasma samples from the T2D group. The fraction of glycated hemoglobin (Hb1Ac) was positively associated with markers of inflammation (C-reactive protein-CRP r = 0.618; p = 0.006) and of dyslipidemia (triglycerides-TG r = 0.815; p < 0.0001). The same marker (Hb1Ac) was negatively associated with mitochondrial activity levels (OXPHOS r = −0.502; p = 0.034; ET r = −0.529; p = 0.024). The results obtained in overweight postmenopausal women from analysis of PBMCs mitochondrial respiration and their association with anthropometric and physiological parameters indicate that PBMC could represent a reliable model for studying T2D-related metabolic impairment and could be useful for testing the effectiveness of interventions targeting mitochondria.

6.
J Gerontol A Biol Sci Med Sci ; 77(3): 588-596, 2022 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-34036337

RESUMO

BACKGROUND: Vascular dysfunction and associated disorders are major side effects of chronic bed rest, yet passive mobilization as a potential treatment has only been theorized so far. This study investigated the effects of passive mobilization treatment on vascular function in older, chronically bedridden people. METHOD: The study sample was 45 chronically bedridden people of advanced age (mean age: 87 years; 56% female; mean bed rest: 4 years) randomly assigned to a treatment (n = 23) or a control group (CTRL, n = 22). The treatment group received passive mobilization twice daily (30 minutes, 5 times/wk) for 4 weeks. A kinesiologist performed passive mobilization by passive knee flexion/extension at 1 Hz in one leg (treated leg [T-leg] vs control leg [Ctrl-leg]). The CTRL group received routine treatment. The primary outcome was changes in peak blood flow (∆peak) as measured with the single passive leg movement test at the common femoral artery. RESULTS: ∆Peak was increased in both legs in the Treatment group (+90.9 mL/min, p < .001, in T-leg and +25.7 mL/min, p = .039 in Ctrl-leg). No difference in peak blood flow after routine treatment was found in the CTRL group. CONCLUSION: Improvement in vascular function after 4 weeks of passive mobilization was recorded in the treatment group. Passive mobilization may be advantageously included in standard clinical practice as an effective strategy to treat vascular dysfunction in persons with severely limited mobility.


Assuntos
Perna (Membro) , Movimento , Idoso , Idoso de 80 Anos ou mais , Feminino , Artéria Femoral/fisiologia , Hemodinâmica/fisiologia , Humanos , Perna (Membro)/fisiologia , Masculino , Movimento/fisiologia , Amplitude de Movimento Articular
7.
J Med Biochem ; 40(4): 335-340, 2021 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-34616223

RESUMO

BACKGROUND: Since universal vaccinations represents the most effective strategy to mitigate coronavirus disease 2019 (COVID-19), baseline assessment and post-vaccine monitoring of anti-SARS-CoV-2 neutralizing antibodies are essential to vaccination programs. Therefore, this study aimed to compare data of five commercial anti-SARS-CoV2 immunoassays after administration of an mRNA vaccine. METHODS: Venous blood was collected from three healthcare workers, receiving a double (30 g) dose of BNT162b2 mRNA Covid-19 vaccine (Comirnaty, Pfizer), on the day of the first vaccine dose and then at fixed intervals for the following 2 months. Anti-SARS-CoV-2 neutralizing antibody response was assayed with Roche Total Ig anti-RBD (receptor binding domain), DiaSorin TrimericS IgG (spike trimer), Beckman Coulter IgG anti-RBD, SNIBE IgG anti-RBD and Technogenetics IgG anti-N/S1. RESULTS: A total number of 45 samples were drawn at the end of the 2-month study period. The Spearman's correlations of absolute anti-SARS-CoV-2 antibodies were always excellent (all p<0.001), comprised between 0.967-0.994. Satisfactory results were also observed when absolute antiSARS-CoV-2 antibodies values of the five methods were compared with the mean consensus value, with correlations always higher than 0.979 (all p<0.001). The agreement of anti-SARS-CoV-2 antibodies positivity versus the consensus median positivity ranged between 0.764 and 1.000 (always p<0.001), but become always >0.900 after readjustment of one assay cutoff. CONCLUSIONS: All the immunoassays evaluated in this study appear suitable for monitoring anti-SARS-CoV-2 neutralizing antibodies response in subjects undergoing mRNA COVID-19 vaccination.

9.
Semin Thromb Hemost ; 47(1): 53-62, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33368118

RESUMO

Epigenetics, a term conventionally used to explain the intricate interplay between genes and the environment, is now regarded as the fundament of developmental biology. Several lines of evidence garnered over the past decades suggest that epigenetic alterations, mostly encompassing DNA methylation, histone tail modifications, and generation of microRNAs, play an important, though still incompletely explored, role in both primary and secondary hemostasis. Epigenetic variations may interplay with platelet functions and their responsiveness to antiplatelet drugs, and they may also exert a substantial contribution in modulating the production and release into the bloodstream of proteins involved in blood coagulation and fibrinolysis. This emerging evidence may have substantial biological and clinical implications. An enhanced understanding of posttranscriptional mechanisms would help to clarify some remaining enigmatic issues in primary and secondary hemostasis, which cannot be thoughtfully explained by genetics or biochemistry alone. Increased understanding would also pave the way to developing innovative tests for better assessment of individual risk of bleeding or thrombosis. The accurate recognition of key epigenetic mechanisms in hemostasis would then contribute to identify new putative therapeutic targets, and develop innovative agents that could be helpful for preventing or managing a vast array of hemostasis disturbances.


Assuntos
Metilação de DNA/genética , Epigênese Genética/genética , Epigenômica/métodos , Hemostasia/genética , Humanos
10.
Diagnostics (Basel) ; 10(8)2020 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-32748848

RESUMO

Bile acids (BAs) assessments are garnering increasing interest for their potential involvement in development and progression of cholangiocarcinoma (CCA). Since machine learning (ML) algorithms are increasingly used for exploring metabolomic profiles, we evaluated performance of some ML models for dissecting patients with CCA or benign biliary diseases according to their plasma BAs profiles. We used ultra-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) for assessing plasma BAs profile in 112 patients (70 CCA, 42 benign biliary diseases). Twelve normalisation procedures were applied, and performance of six ML algorithms were evaluated (logistic regression, k-nearest neighbors, naïve bayes, RBF SVM, random forest, extreme gradient boosting). Naïve bayes, using direct bilirubin concentration for normalisation of BAs, was the ML model displaying better performance in the holdout set, with an Area Under Curve (AUC) of 0.95, 0.79 sensitivity, 1.00 specificity. This model, also characterised by 1.00 positive predictive value and 0.73 negative predictive value, displayed a globally excellent accuracy (86.4%). The accuracy of the other five models was lower, and AUCs ranged 0.75-0.95. Preliminary results of this study show that application of ML to BAs profile analysis can provide a valuable contribution for characterising bile duct diseases and identifying patients with higher likelihood of having malignant pathologies.

11.
J Med Biochem ; 39(1): 19-24, 2020 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-32549773

RESUMO

BACKGROUND: This study aimed to verify whether blood drawn into six different commercial coagulation tubes generated comparable results of thrombin generation. METHODS: Blood was sequentially collected from 20 healthy subjects into different brand and draw volume 3.2% sodium citrate tubes (4.3 mL Sarstedt, 3.0 mL Greiner, 2.7 mL Becton Dickinson, 2.0 mL Kima, 1.8 mL Sarstedt and 1.0 mL Greiner). Thrombin generation was measured in plasma with the fully-automated ST Genesia analyzer using the weakest trigger (STG-BleedScreen). RESULTS: Different values of lag time (LT), time to reach thrombin peak (TP), thrombin peak height (PH) and endogenous thrombin potential (ETP) were commonly found in different tubes. Thrombin generation was the lowest in 4.3 mL Sarstedt tubes and the highest in 1.0 mL Greiner tubes. Other tubes displayed intermediate values. In multiple comparisons, LT was significantly different in 6/15 cases (40%), whilst PH, TP and ETP were significantly different in 14/15 (93%), 13/15 (87%) and 13/15 (87%) cases. The mean percent bias of LT, PH, TP and ETP ranged between -6% and +1%, -27% and +116%, -22% and +8%, and between -18% and +65%. The intra-assay imprecision of LT, PH, TP and ETP was exceeded in 0/15 (0%), 13/15 (87%), 6/15 (40%) and 13/15 (87%) comparisons. The correlation of LT, PH, TP and ETP values in different tubes ranged between 0.718-0.971, 0.570-0.966, 0.725-0.977 and 0.101-0.904. CONCLUSIONS: Blood collection for thrombin generation assays requires local standardization using identical tubes for brand and draw volume, and reference ranges calculated according to type of tubes.

12.
J Clin Med ; 9(4)2020 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-32230833

RESUMO

The interplay between chronic constraint and advanced aging on blood flow, shear-rate, vascular function, nitric oxide (NO)-bioavailability, microcirculation, and vascular inflammation factors is still a matter of debate. Ninety-eight individuals (Young, n=28, 23±3yrs; Old, n=36, 85±7yrs; Bedridden, n=34, 88±6yrs) were included in the study. The bedridden group included old individuals chronically confined to bed (3.8±2.3yrs). A blood sample was collected and analyzed for plasma nitrate, and vascular inflammatory markers. Hyperemic response (∆peak) during the single passive leg movement (sPLM) test was used to measure vascular function. Skeletal muscle total hemoglobin was measured at the vastus lateralis during the sPLM test, by means of near infrared spectroscopy (NIRS). Bedridden subjects revealed a depletion of plasma nitrates compared with Old (-23.8%) and Young (-31.1%). Blood flow was lower in the Bedridden in comparison to Old (-20.1%) and Young (-31.7%). Bedridden presented lower sPLM ∆peak compared Old (-72.5%) and the Young (-83.3%). ∆peak of NIRS total hemoglobin was lower in the Bedridden compared to that in the Young (-133%). All vascular inflammatory markers except IL-6 were significantly worse in the Bedridden compared to Old and Young. No differences were found between the Old and Young in inflammatory markers. Results of this study confirm that chronic physical constraint induces an exacerbation of vascular disfunction and differential regulation of vascular-related inflammatory markers. The mechanisms involved in these negative adaptations seems to be associated with endothelial dysfunction and consequent diminished NO-bioavailability likely caused by the reduced shear-rate consequential to long-term reduction of physical activity.

13.
Clin Chem Lab Med ; 58(10): 1707-1712, 2020 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-32286239

RESUMO

Background Calcitonin gene-related peptide (CGRP) is a powerful neuropeptide that is strongly involved in headache pain pathogenesis by triggering vasodilation, mast cell degranulation and neurogenic inflammation. This evidence has prompted us to investigate the acute influence of endurance exercise on CGRP concentration in blood. Methods The study population consisted of 48 male amateur runners, who ran a half-marathon distance at 75%-85% of maximal oxygen uptake. Blood was drawn before the run (pre-run) and immediately after each runner ended his trial (post-run). The serum concentration of CGRP was measured with a commercial enzyme-linked immunosorbent assay (ELISA) technique. Results Overall, 22/48 subjects (45.8%) reported suffering from headache, three of whom (6.2%) had an exertional headache, whilst 26/48 (54.2%) subjects did not report at least one headache episode during the previous 6 months (i.e. headache-free). All 48 athletes successfully covered the 21.1 km distance. Serum concentration of CGRP significantly increased by 1.5-fold in the entire group, as well as in the headache-positive and headache-free cohorts. Univariate Spearman's correlation revealed that post-run variation of serum CGRP was significantly and inversely associated with running time (r = -0.30; p = 0.036). Conclusions The serum concentration of CGRP is significantly enhanced by medium-distance endurance exercise and the post-exercise increase is dependent on running intensity. Accordingly, high-exercise intensity might be directly related to triggering both exertional headache and/or migraine episodes.


Assuntos
Peptídeo Relacionado com Gene de Calcitonina/sangue , Exercício Físico , Cefaleia/sangue , Resistência Física , Adulto , Humanos , Masculino , Pessoa de Meia-Idade
14.
Diagnostics (Basel) ; 10(3)2020 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-32111028

RESUMO

This study was designed to evaluate the analytical performance of the recently commercialized Beckman Coulter Access procalcitonin (PCT) chemiluminescent test on the Access immunoassay system. The analytical assessment encompassed the estimation of limit of blank (LoB), limit of detection (LoD), functional sensitivity (i.e., PCT value with ≤10% imprecision), linearity, imprecision and comparability of values with BRAHMS PCT-sensitive Kryptor. LoB, LoD and functional sensitivity were 0.002 µg/L, 0.003 µg/L and 0.003 µg/L, respectively. Intra-assay, inter-assay and total imprecision for plasma pools with low, medium and high PCT values were 1.8%-2.1%, 2.4%-3.7% and 3.1%-4.3%, respectively. The assay exhibited excellent linearity between 0.02 and 84.0 µg/L. Excellent correlation (r = 0.999; p < 0.001) and negligible bias (3.2%) were found by comparing values obtained in paired plasma samples with BRAHMS PCT-sensitive Kryptor. Diagnostic agreement at 0.5, 2.0 and 10 µg/L PCT values ranged between 98%-100%. The results of this study confirm that Access PCT displays excellent analytical performance and high comparability with BRAHMS PCT-sensitive Kryptor.

15.
Clin Chem Lab Med ; 58(1): 77-84, 2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-31539351

RESUMO

Background This two-center study was designed to verify comparability of procalcitonin (PCT) values among 10 different commercial immunoassays. Methods A total number of 176 routine lithium-heparin plasma samples were divided in identical aliquots and simultaneously analyzed with 10 different PCT immunoassays, including Kryptor BRAHMS PCT sensitive, Abbott Architect BRAHMS PCT, Beckman Coulter Access PCT (on Access and DXI), BioMérieux Vidas BRAHMS PCT, Diasorin Liaison BRAHMS PCT, Fujirebio Lumipulse G BRAHMS PCT, Roche BRAHMS PCT (on Cobas E801), Diazyme PCT (on Roche Cobas C702) and SNIBE Maglumi PCT. Results Highly significant correlation was always found across multiple comparisons, with correlation coefficients comprised between 0.918 and 0.997 (all p < 0.001). Bland and Altman plots analysis revealed highly variable bias among immunoassays, ranging between ±0.2% and ±38.6%. Diazyme PCT on Roche Cobas C702 and SNIBE Maglumi PCT displayed the larger overestimation, whilst PCT values were underestimated by Cobas BRAHAMS PCT. The agreement was always >80% (all p < 0.001), but varied largely across multiple comparisons, ranging between 90%-99% at 0.1 µg/L, 81%-99% at 0.25 µg/L, 83%-100% at 0.5 µg/L, 94%-100% at 2.0 µg/L and 90%-99% at 10 µg/L, respectively. The larger disagreement was observed comparing Diazyme PCT and Maglumi PCT with the other methods. Conclusions Although we found acceptable correlation among 10 commercial PCT immunoassays, the limited agreement at clinical decision thresholds remains a major issue, especially at lower end of PCT concentration, thus potentially contributing to jeopardize the clinical value of this biomarker.


Assuntos
Imunoensaio/métodos , Pró-Calcitonina/análise , Automação , Humanos , Pró-Calcitonina/sangue , Pró-Calcitonina/imunologia
16.
Scand J Clin Lab Invest ; 79(4): 276-279, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31035815

RESUMO

Current recommendations advocate that blood tubes for coagulation testing should be filled not less than 90% of their nominal filling volume, since under- or over-filling >10% may generate unreliable results of some hemostasis assays. This study was hence aimed to explore filling accuracy and precision of commercial blood tubes. Between-lot variations of 3 different lots (20 tubes per lot) of 3.2% citrate blood tubes manufactured by Becton Dickinson, Greiner and Kima were studied. One additional lot from each manufacturer was assessed in triplicate (three series of 20 tubes), to assess within-lot variation. All tubes were first weighed empty and then filled with distilled water by a syringe, under ideal filling conditions. Filled tubes were weighed again, in duplicate. For each 20 tubes series, mean bias (deviation from the ideal tube filling volume) and imprecision (coefficient of variation; CV%) were calculated. All biases were within ±10%. Within-lot and between-lot variation in filling volume was acceptable, and comprised between 0.4 and 2.4%. Greiner tubes were the most accurate (bias, -1.0 to 2.4%), followed by Kima (bias, -7.8 to -5.9%) and Becton Dickinson (bias, -9.6 to 3.3%) tubes. The highest between-lot difference was noted for Becton Dickinson tubes (up to 12.9%), followed by Greiner and Kima tubes (up to 3.4 and 1.8%, respectively). Although coagulation tubes filling accuracy was within ±10% for all three tested manufacturers, the overall bias was found to be variable among manufacturers and lots. Major effort shall be made by blood tube manufacturers for improving standardization of their products.


Assuntos
Testes de Coagulação Sanguínea/economia , Testes de Coagulação Sanguínea/instrumentação , Coagulação Sanguínea/efeitos dos fármacos , Citrato de Sódio/farmacologia , Humanos
17.
Clin Chem Lab Med ; 57(11): 1784-1789, 2019 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-30939111

RESUMO

Background Although accumulating evidence suggests that the hemostatic balance is impaired in patients with hypertriglyceridemia, hyperbilirubinemia or hemolytic anemias, little is known on the underlying biological mechanisms. This experimental study was aimed at exploring whether increasing values of triglycerides, bilirubin or cell-free hemoglobin promote thrombin generation in plasma. Methods Three different pools were prepared from three different sets of 20 normal routine plasma citrate samples. The native pools were spiked with increasing amounts of exogenous triglycerides (up to 8.8 mmol/L), bilirubin (up to 350 µmol/L) or autologous hemolyzed blood (up to 3.5 g/L cell-free hemoglobin). Using the fully-automated thrombin generation analyzer ST Genesia, we measured the following parameters: lag time (LT), time to peak (TP), peak height (PH) and endogenous thrombin potential (ETP). Results A sustained increase of PH and ETP was found in parallel with increasing triglyceride concentrations, peaking in the aliquot with 8.8 mmol/L. Conversely, LT and TP displayed an opposite trend, reaching a maximum decrease in the 8.8 mmol/L aliquot. Increasing bilirubin concentrations promoted remarkable increases of PH and ETP and decreases of TP and LT, up to 211 µmol/L. After this threshold, all parameters tended to return towards baseline values. A constant increase of PH and ETP was also noted in hemolyzed samples, peaking in the 3.5 g/L cell-free hemoglobin aliquot, whereas the TP and LT remained unchanged in all hemolyzed aliquots. Conclusions Our findings suggest that hypertriglyceridemia, hyperbilirubinemia and hemolysis may promote a hypercoagulable state in human plasma.


Assuntos
Hemólise/fisiologia , Hiperbilirrubinemia/sangue , Plasma/metabolismo , Trombina/efeitos adversos , Testes de Coagulação Sanguínea/métodos , Feminino , Humanos , Hiperbilirrubinemia/etiologia , Hipertrigliceridemia/sangue , Hipertrigliceridemia/etiologia , Masculino
18.
Semin Thromb Hemost ; 45(3): 308-314, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30699441

RESUMO

This study aimed to provide a preliminary evaluation of the analytical performance of the new Roche COBAS T 711: fully automated coagulation analyzer, which uses both liquid and lyophilized reagent cassettes. The analytical assessment included analysis of imprecision and linearity of prothrombin time (PT), activated partial thromboplastin time (APTT), and fibrinogen on COBAS T 711: analyzer. Test results of 120 routine plasma samples were also compared with those obtained using two other coagulation analyzers (Instrumentation Laboratory ACL TOP 700 and Stago STA-R MAX). The accuracy, imprecision, and comparability of manual and automatic lyophilized material resuspension were also evaluated using 200 routine plasma samples. Overall, automatic resuspension was found to be more precise than, and equally accurate as, manual reconstitution, with coefficient of variations (CV%) three- to sixfold lower compared with manual reconstitution. The analytical imprecision was found to be excellent, as attested by total CV% of 0.7% for PT, 1.7 to 1.8% for APTT, and 1.9 to 3.2% for fibrinogen. Linearity was excellent over a clinically significant range of PT, APTT, and fibrinogen values, displaying correlation coefficients comprised between 0.994 and 0.999. Methods comparison studies revealed that results of PT, APTT, and fibrinogen on COBAS T 711: are globally aligned with those obtained using identical plasma samples on IL ACL TOP 700 and Stago STA-R MAX, displaying correlation coefficients of 0.97 for PT, 0.81 and 0.88 for APTT, 0.90 and 0.94 for fibrinogen, respectively. In conclusion, the results of this preliminary evaluation demonstrate that PT, APTT, and fibrinogen on COBAS T 711: coagulation analyzer displays excellent performance for routine use in clinical laboratories.


Assuntos
Testes de Coagulação Sanguínea/métodos , Coagulação Sanguínea/imunologia , Hemostasia/imunologia , Humanos , Laboratórios
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...