Objective: We sought to determine whether an electronic hand hygiene (HH) system could monitor HH compliance at similar rates to direct human observation. Methods: This 4-year proof-of-concept study was conducted in an intensive care unit (ICU) of a private tertiary-care hospital in São Paulo, Brazil, where electronic HH systems were installed in 2 rooms. HH compliance was reported respectively using direct observation and electronic counter devices with an infrared system for detecting HH opportunities. Results: In phase 1, HH compliance by human observers was 56.3% (564 of 1,001 opportunities), while HH compliance detected by the electronic observer was 51.0% (515 of 1,010 opportunities). In phase 2, human observers registered 484 HH opportunities with a HH compliance rate of 64.7% (313 of 484) versus 70.6% (346 of 490) simultaneously detected by the electronic system. In addition, an enhanced HH electronic system monitored activity 24 hours per day and HH compliance without the presence of a human observer was 40.3% (10,642 of 26,421 opportunities), providing evidence for the Hawthorne effect. Conclusions: The electronic HH monitoring system had good correlation with human HH observation, but compliance was remarkably lower when human observers were not present due to the Hawthorne effect (25%-30% absolute difference). Electronic monitoring systems can replace direct observation and can markedly reduce the Hawthorne effect.

2.
Artigo em Inglês | MEDLINE | ID: mdl-36483415

RESUMO

Background: Most hand hygiene (HH) intervention studies use a quasi-experimental design, are primarily uncontrolled before-and-after studies, or are controlled before-and-after studies with a nonequivalent control group. Well-funded studies with improved designs and HH interventions are needed. Objectives: To evaluate healthcare worker (HCW) HH compliance with alcohol-based hand rub (ABHR) through direct observation (human observer), 2 electronic technologies, a radio frequency identification (RFID) badge system, and an invasive device sensor. Methods: In our controlled experimental study, 2,269 observations were made over a 6-month period from July 1 to December 30, 2020, in a 4-bed intensive care unit. We compared HH compliance between a basic feedback loop system with RFID badges and an enhanced feedback loop system that utilized sensors on invasive devices. Results: Real-time feedback by wireless technology connected to a patient's invasive device (enhanced feedback loop) resulted in a significant increase in HH compliance (69.5% in the enhanced group vs 59.1% in the basic group; P = .0001). Conclusion: An enhanced feedback loop system connected to invasive devices, providing real-time alerts to HCWs, is effective in improving HH compliance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA