1.
Vasc Specialist Int ; 38: 10, 2022 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-35383133

RESUMO

Iatrogenic trauma of the axillary artery by non-vascular surgeons can occur during various general surgical procedures such as resection of soft tissue tumors or axillary lymph node clearance. Prompt recognition, appropriate initial management, and rapid transfer to a tertiary vascular surgery service, if needed, are key steps to ensuring patient safety. Here we present a case of iatrogenic axillary artery injury during the resection of a recurrent soft tissue tumor in a local hospital. The desperate application of a Kocher clamp on the bleeding axillary artery by the operating general surgeons controlled the bleeding but led to further arterial damage. The patient was transferred to our tertiary hospital, where the arterial injury was repaired using a vein interposition graft. Apart from the encountered intraoperative technical challenges, this case highlights the need for broader training of nonvascular specialist surgeons on the core principles of basic vascular surgical techniques and oncovascular surgery.

2.
Ann Vasc Surg ; 72: 663.e1-663.e4, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33227476

RESUMO

We present an unreported complication that occurred during an accidental loss of the ipsilateral limb's wire during EVAR. During an endovascular repair of an abdominal aortic aneurysm (EVAR), unintentional loss of the ipsilateral limb's wire during deployment and withdrawal of the endogaft's main body occurred. The snare's loops were entrapped while attempting to catch the wire through the limb. Multiple maneuvers were performed to detach the snare, but all were unsuccessful. We then performed a conversion to open repair. In conclusion, commercially available endografts should include standard radiopaque markers in the ipsilateral limb to facilitate retrograde cannulation. Retrieval via the snare should not be performed proximal to the gate of the limb.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Conversão para Cirurgia Aberta , Remoção de Dispositivo , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Desenho de Prótese , Resultado do Tratamento
3.
J Vasc Surg ; 49(3): 782-9, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19028054

RESUMO

BACKGROUND: Aortoenteric fistula (AEF) is a critical clinical condition, which may present with gastrointestinal hemorrhage, with or without signs of sepsis. Conventional open surgical repair is associated with high morbidity and mortality. Endovascular stent graft repair has been attempted, but recurrent infection remains of major concern. We conducted a systematic review to assess potential factors associated with poor outcome after endovascular treatment. METHODS: The English literature was searched using the MEDLINE electronic database up to April 2008. All studies reporting on the primary management of primary or secondary AEF with endovascular stent graft repair were considered. RESULTS: Data were extracted from 33 reports that included 41 patients and were entered in the final analysis. Persistent/recurrent/new infection or recurrent hemorrhage developed in 44% of the patients, after a mean follow-up period of 13 months (range, 0.13-36). Secondary, as compared to primary, AEF had an almost threefold increased risk of persistent/recurrent infection. Evidence of sepsis preoperatively was found to be a factor indicating unfavorable outcome (P < .05). Persistent/recurrent/new infection after treatment was associated with worse 30-day and overall survival compared with those who did not develop sepsis (P < .05). CONCLUSION: Endovascular stent graft repair of AEF was associated with a high incidence of infection or recurrent bleeding postoperatively. Evidence of sepsis preoperatively was indicating poor outcome.


Assuntos
Doenças da Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Fístula do Sistema Digestório/cirurgia , Stents , Fístula Vascular/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças da Aorta/mortalidade , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Fístula do Sistema Digestório/mortalidade , Feminino , Hemorragia Gastrointestinal/etiologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/etiologia , Recidiva , Medição de Risco , Fatores de Risco , Sepse/complicações , Stents/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Fístula Vascular/mortalidade