Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Sci (Weinh) ; 10(36): e2302550, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37939279

RESUMO

Resonant absorption of a photon by bound electrons in a solid can promote an electron to another orbital state or transfer it to a neighboring atomic site. Such a transition in a magnetically ordered material could affect the magnetic order. While this process is an obvious road map for optical control of magnetization, experimental demonstration of such a process remains challenging. Exciting a significant fraction of magnetic ions requires a very intense incoming light beam, as orbital resonances are often weak compared to above-band-gap excitations. In the latter case, a sizeable reduction of the magnetization occurs as the absorbed energy increases the spin temperature, masking the non-thermal optical effects. Here, using ultrafast X-ray spectroscopy, this work is able to resolve changes in the magnetization state induced by resonant absorption of infrared photons in Co-doped yttrium iron garnet, with negligible thermal effects. This work finds that the optical excitation of the Co ions affects the two distinct magnetic Fe sublattices differently, resulting in a transient non-collinear magnetic state. The present results indicate that the all-optical magnetization switching (AOS) most likely occurs due to the creation of a transient, non-collinear magnetic state followed by coherent spin rotations of the Fe moments.

2.
Struct Dyn ; 10(5): 054501, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37841290

RESUMO

Free-electron lasers provide bright, ultrashort, and monochromatic x-ray pulses, enabling novel spectroscopic measurements not only with femtosecond temporal resolution: The high fluence of their x-ray pulses can also easily enter the regime of the non-linear x-ray-matter interaction. Entering this regime necessitates a rigorous analysis and reliable prediction of the relevant non-linear processes for future experiment designs. Here, we show non-linear changes in the L3-edge absorption of metallic nickel thin films, measured with fluences up to 60 J/cm2. We present a simple but predictive rate model that quantitatively describes spectral changes based on the evolution of electronic populations within the pulse duration. Despite its simplicity, the model reaches good agreement with experimental results over more than three orders of magnitude in fluence, while providing a straightforward understanding of the interplay of physical processes driving the non-linear changes. Our findings provide important insights for the design and evaluation of future high-fluence free-electron laser experiments and contribute to the understanding of non-linear electron dynamics in x-ray absorption processes in solids at the femtosecond timescale.

3.
J Synchrotron Radiat ; 30(Pt 2): 284-300, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36891842

RESUMO

Femtosecond transient soft X-ray absorption spectroscopy (XAS) is a very promising technique that can be employed at X-ray free-electron lasers (FELs) to investigate out-of-equilibrium dynamics for material and energy research. Here, a dedicated setup for soft X-rays available at the Spectroscopy and Coherent Scattering (SCS) instrument at the European X-ray Free-Electron Laser (European XFEL) is presented. It consists of a beam-splitting off-axis zone plate (BOZ) used in transmission to create three copies of the incoming beam, which are used to measure the transmitted intensity through the excited and unexcited sample, as well as to monitor the incoming intensity. Since these three intensity signals are detected shot by shot and simultaneously, this setup allows normalized shot-by-shot analysis of the transmission. For photon detection, an imaging detector capable of recording up to 800 images at 4.5 MHz frame rate during the FEL burst is employed, and allows a photon-shot-noise-limited sensitivity to be approached. The setup and its capabilities are reviewed as well as the online and offline analysis tools provided to users.

4.
Opt Express ; 30(12): 20980-20998, 2022 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-36224830

RESUMO

A real-time and accurate characterization of the X-ray beam size is essential to enable a large variety of different experiments at free-electron laser facilities. Typically, ablative imprints are employed to determine shape and size of µm-focused X-ray beams. The high accuracy of this state-of-the-art method comes at the expense of the time required to perform an ex-situ image analysis. In contrast, diffraction at a curved grating with suitably varying period and orientation forms a magnified image of the X-ray beam, which can be recorded by a 2D pixelated detector providing beam size and pointing jitter in real time. In this manuscript, we compare results obtained with both techniques, address their advantages and limitations, and demonstrate their excellent agreement. We present an extensive characterization of the FEL beam focused to ≈1 µm by two Kirkpatrick-Baez (KB) mirrors, along with optical metrology slope profiles demonstrating their exceptionally high quality. This work provides a systematic and comprehensive study of the accuracy provided by curved gratings in real-time imaging of X-ray beams at a free-electron laser facility. It is applied here to soft X-rays and can be extended to the hard X-ray range. Furthermore, curved gratings, in combination with a suitable detector, can provide spatial properties of µm-focused X-ray beams at MHz repetition rate.

5.
Sci Adv ; 8(13): eabn0523, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35363518

RESUMO

Magnetic nanoparticles such as FePt in the L10 phase are the bedrock of our current data storage technology. As the grains become smaller to keep up with technological demands, the superparamagnetic limit calls for materials with higher magnetocrystalline anisotropy. This, in turn, reduces the magnetic exchange length to just a few nanometers, enabling magnetic structures to be induced within the nanoparticles. Here, we describe the existence of spin-wave solitons, dynamic localized bound states of spin-wave excitations, in FePt nanoparticles. We show with time-resolved x-ray diffraction and micromagnetic modeling that spin-wave solitons of sub-10 nm sizes form out of the demagnetized state following femtosecond laser excitation. The measured soliton spin precession frequency of 0.1 THz positions this system as a platform to develop novel miniature devices.

6.
ChemMedChem ; 17(3): e202100577, 2022 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-34783161

RESUMO

A series of new 5-aryl-2,2'-bipyridines and their (polyfluoro)salicylate complexes of Cu(II), Co(II) and Mn(II) were synthesized. Their antimicrobial activity was evaluated in vitro against six strains of Trichophytons, E. floccosum, M. canis, C. ablicans and Gram-negative bacteria N. gonorrhoeae. Among azo-ligands, Ph-bipy and Tol-bipy showed promising antifungal activity (minimum inhibitory concentration (MIC)<0.8-27 µM). Their antifungal action was found can be realized via binding Fe(III) ions. Tol-bipy suppressed growth of Gram-positive bacteria S. aureus, S. aureus MRSA and their monospecies biofilms (MIC 6-16 µM). Using molecular docking, the anti-staphylococcal action mechanism based on the inhibition of S. aureus DNA gyrase GyrB was proposed for the lead compounds. Among metal complexes, Cu(II) and Mn(II) complexes based on tetrafluorosalicylic acid and Tol-bipy or Ph-bipy had the high antifungal activity (MIC<0.24-32 µM). Mn(SalF4 -2H)2 (Tol-bipy)2 ] suppressed the growth of seven Candida strains at MIC 12-24 µM. [Cu(Sal-2H)(Ph-bipy)] and [Cu(SalF3 -2H)(Ph-bipy)2 ] showed the promising anti-gonorrhoeae activity (MIC 4.2-5.2 µM). (Cu(SalFn -2H)(Tol-bipy)2 ], [Cu(SalF4 -2H)(Ph-bipy)2 ] and [Cu(SalF3 -2H)(Ph-bipy)2 ]) were found active against the bacteria of S. aureus, S. aureus MRSA and their biofilms (MIC 2.4-41.4 µM). The most active compounds were tested for toxicity in vitro against human embryonic kidney (HEK-293) cells and in vivo experiments with CD-1 mice.


Assuntos
Antibacterianos/farmacologia , Antifúngicos/farmacologia , Complexos de Coordenação/farmacologia , Metais Pesados/farmacologia , Simulação de Acoplamento Molecular , Salicilatos/farmacologia , Animais , Antibacterianos/síntese química , Antibacterianos/química , Antifúngicos/síntese química , Antifúngicos/química , Sobrevivência Celular/efeitos dos fármacos , Complexos de Coordenação/síntese química , Complexos de Coordenação/química , Relação Dose-Resposta a Droga , Fungos/efeitos dos fármacos , Células HEK293 , Humanos , Metais Pesados/química , Camundongos , Testes de Sensibilidade Microbiana , Estrutura Molecular , Neisseria gonorrhoeae/efeitos dos fármacos , Salicilatos/química , Relação Estrutura-Atividade
7.
Molecules ; 28(1)2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36615256

RESUMO

4-Arylhydrazinylidene-5-(polyfluoroalkyl)pyrazol-3-ones (4-AHPs) were found to be obtained by the regiospecific cyclization of 2-arylhydrazinylidene-3-(polyfluoroalkyl)-3-oxoesters with hydrazines, by the azo coupling of 4-nonsubstituted pyrazol-5-oles with aryldiazonium chlorides or by the firstly discovered acid-promoted self-condensation of 2-arylhydrazinylidene-3-oxoesters. All the 4-AHPs had an acceptable ADME profile. Varying the substituents in 4-AHPs promoted the switching or combining of their biological activity. The polyfluoroalkyl residue in 4-AHPs led to the appearance of an anticarboxylesterase action in the micromolar range. An NH-fragment and/or methyl group instead of the polyfluoroalkyl one in the 4-AHPs promoted antioxidant properties in the ABTS, FRAP and ORAC tests, as well as anti-cancer activity against HeLa that was at the Doxorubicin level coupled with lower cytotoxicity against normal human fibroblasts. Some Ph-N-substituted 4-AHPs could inhibit the growth of N. gonorrhoeae bacteria at MIC 0.9 µg/mL. The possibility of using 4-AHPs for cell visualization was shown. Most of the 4-AHPs exhibited a pronounced analgesic effect in a hot plate test in vivo at and above the diclofenac and metamizole levels except for the ones with two chlorine atoms in the aryl group. The methylsulfonyl residue was proved to raise the anti-inflammatory effect also. A mechanism of the antinociceptive action of the 4-AHPs through blocking the TRPV1 receptor was proposed and confirmed using in vitro experiment and molecular docking.


Assuntos
Antioxidantes , Diclofenaco , Humanos , Simulação de Acoplamento Molecular , Antioxidantes/química , Preparações Farmacêuticas
8.
Struct Dyn ; 8(4): 044305, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34476285

RESUMO

Second-order intensity interferometry was employed to study the spatial and temporal properties of the European X-ray Free-Electron Laser (EuXFEL). Measurements were performed at the soft x-ray Self-Amplified Spontaneous Emission (SASE3) undulator beamline at a photon energy of 1.2 keV in the Self-Amplified Spontaneous Emission (SASE) mode. Two high-power regimes of the SASE3 undulator settings, i.e., linear and quadratic undulator tapering at saturation, were studied in detail and compared with the linear gain regime. The statistical analysis showed an exceptionally high degree of spatial coherence up to 90% for the linear undulator tapering. Analysis of the measured data in spectral and spatial domains provided an average pulse duration of about 10 fs in our measurements. The obtained results will be valuable for the experiments requiring and exploiting short pulse duration and utilizing high coherence properties of the EuXFEL.

9.
J Synchrotron Radiat ; 28(Pt 1): 3-17, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33399547

RESUMO

The emerging concept of `beam by design' in free-electron laser (FEL) accelerator physics aims for accurate manipulation of the electron beam to tailor spectral and temporal properties of the radiation for specific experimental purposes, such as X-ray pump/X-ray probe and multiple wavelength experiments. `Beam by design' requires fast, efficient, and detailed feedback on the spectral and temporal properties of the generated X-ray radiation. Here a simple and cost-efficient method to extract information on the longitudinal Wigner distribution function of emitted FEL pulses is proposed. The method requires only an ensemble of measured FEL spectra and is rather robust with respect to accelerator fluctuations. The method is applied to both the simulated SASE spectra with known radiation properties as well as to the SASE spectra measured at the European XFEL revealing underlying non-linear chirp of the generated radiation. In the Appendices an intuitive understanding of time-frequency representations of chirped SASE radiation is provided.

10.
Nat Mater ; 20(1): 30-37, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33020615

RESUMO

Topological states of matter exhibit fascinating physics combined with an intrinsic stability. A key challenge is the fast creation of topological phases, which requires massive reorientation of charge or spin degrees of freedom. Here we report the picosecond emergence of an extended topological phase that comprises many magnetic skyrmions. The nucleation of this phase, followed in real time via single-shot soft X-ray scattering after infrared laser excitation, is mediated by a transient topological fluctuation state. This state is enabled by the presence of a time-reversal symmetry-breaking perpendicular magnetic field and exists for less than 300 ps. Atomistic simulations indicate that the fluctuation state largely reduces the topological energy barrier and thereby enables the observed rapid and homogeneous nucleation of the skyrmion phase. These observations provide fundamental insights into the nature of topological phase transitions, and suggest a path towards ultrafast topological switching in a wide variety of materials through intermediate fluctuating states.

11.
Eur J Med Chem ; 208: 112768, 2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-32932211

RESUMO

4-Nitroso-3-trifluoromethyl-5-alkyl[(het)aryl]pyrazoles were synthesized via one-pot nitrosation of 1,3-diketones or their lithium salts followed by treatment of hydrazines. Reduction of nitroso-derivatives made it possible to obtain 4-amino-3-trifluoromethylpyrazoles chlorides. According to computer-aided calculations, all synthesized compounds are expected to have acceptable ADME profile for drug design. Tuberculostatic, antibacterial, antimycotic, antioxidant and cytotoxic activities of the compounds were evaluated in vitro, while their analgesic and anti-inflammatory action was tested in vivo along with acute toxicity studies. N-Unsubstituted 4-nitrosopyrazoles were the most effective tuberculostatics (MIC to 0.36 µg/ml) and antibacterial agents against Streptococcus pyogenes (MIC to 7.8 µg/ml), Staphylococcus aureus,S. aureus MRSA and Neisseria gonorrhoeae (MIC to 15.6 µg/ml). 4-Nitroso-1-methyl-5-phenylpyrazole had the pronounced antimycotic action against a wide range of fungi (Trichophytonrubrum, T. tonsurans, T. violaceum, T. interdigitale, Epidermophytonfloccosum, Microsporumcanis with MIC 0.38-12.5 µg/ml). N-Unsubstituted 4-aminopyrazoles shown high radical-scavenging activity in ABTS test, ORAC/AAPH and oxidative erythrocyte hemolysis assays. 1-Methyl-5-phenyl-3-trifluoromethylpyrazol-4-aminium chloride revealed potential anticancer activity against HeLa cells (SI > 1351). The pronounced analgesic activity was found for 4-nitroso- and 4-aminopyrazoles having phenyl fragment at the position 5 in "hot plate" test. The most of the obtained pyrazoles had a moderate acute toxicity.


Assuntos
Compostos Nitrosos/farmacologia , Pirazóis/farmacologia , Animais , Bactérias/efeitos dos fármacos , Ensaios de Seleção de Medicamentos Antitumorais , Epidermophyton/efeitos dos fármacos , Células HeLa , Humanos , Camundongos , Testes de Sensibilidade Microbiana , Estrutura Molecular , Compostos Nitrosos/síntese química , Compostos Nitrosos/farmacocinética , Compostos Nitrosos/toxicidade , Pirazóis/síntese química , Pirazóis/farmacocinética , Pirazóis/toxicidade , Ratos Sprague-Dawley , Relação Estrutura-Atividade , Trichophyton/efeitos dos fármacos
12.
J Synchrotron Radiat ; 23(1): 123-31, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26698054

RESUMO

The Kirkpatrick-Baez (KB) refocusing mirror system installed at the PG1 branch of the plane-grating monochromator beamline at the soft X-ray/XUV free-electron laser in Hamburg (FLASH) is designed to provide tight aberration-free focusing down to 4 µm × 6 µm full width at half-maximum (FWHM) on the sample. Such a focal spot size is mandatory to achieve ultimate resolution and to guarantee best performance of the vacuum-ultraviolet (VUV) off-axis parabolic double-monochromator Raman spectrometer permanently installed at the PG1 beamline as an experimental end-station. The vertical beam size on the sample of the Raman spectrometer, which operates without entrance slit, defines and limits the energy resolution of the instrument which has an unprecedented design value of 2 meV for photon energies below 70 eV and about 15 meV for higher energies up to 200 eV. In order to reach the designed focal spot size of 4 µm FWHM (vertically) and to hold the highest spectrometer resolution, special fully motorized in-vacuum manipulators for the KB mirror holders have been developed and the optics have been aligned employing wavefront-sensing techniques as well as ablative imprints analysis. Aberrations like astigmatism were minimized. In this article the design and layout of the KB mirror manipulators, the alignment procedure as well as microfocus optimization results are presented.

13.
J Int AIDS Soc ; 17(4 Suppl 3): 19642, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25394146

RESUMO

INTRODUCTION: Depletion of cellular pool and constant activation of plasmacytoid dendritic cells (pDCs) in HIV-infected persons (HIV+) are associated with disease progression and manifestation of opportunistic infections. The influence of highly-active antiretroviral treatment (HAART) and suppressed HCV-co-infection (HIV+/HCV+) on the extent of these changes remains unknown. OBJECTIVE: To study parameters of pDCs in peripheral blood of HIV+ and HIV+/HCV+ patients on HAART. METHODS: Twelve uninfected with HIV or HCV volunteers and 37 patients (12 HIV+, 9 HIV+/HCV+ and 16 HCV+) were enrolled. All HIV+ patients received HAART and had undetermined HIV viral load. All HCV+ patients had finished antiviral therapy (Pegasys/ribavirin) with sustained viral response for six months and more. The pDC population was enumerated by flow cytometry. In vitro IFN production in the whole blood in response to pDC-specific stimulus unmethylated CpG oligonucleotides was determined by enzyme-linked immunosorbent assay (ELISA). RESULTS: The percentage of pDCs of peripheral blood mononuclear cells (PBMC) in HIV+/HCV+ was the lowest (0.08±0.02) but statistically not different from HIV+ (0.15±0.03; p=0.11) and significantly lower than HCV+ (0.17±0.015; p=0.4) and controls (0.27±0.045; p=0.03). Absolute number of pDCs in HIV+ on HAART (6.3±1.3) was not significantly lower than the control (10.25±1.75; p=0.09) but in HIV+/HCV+ (5.1±1.2; p=0.03), the difference was valid. IFN-alpha production by pDCs in patients on HAART in HIV+ (2.4±0.9 pg/µl) and in HIV+/HCV+ (3.7±1 pg/µl) patients were significantly higher than in controls (in controls IFN-alpha production by pDCs in the native plasma was below the level of detection (3 pg/µl), p=0.02 and p=0.0014). CONCLUSIONS: Absolute number of pDC in HIV-positive person on HAART with sustained viral response to treatment of HCV-co-infection was lower than in HIV-mono-infected. IFN-alpha production by pDC in HIV+ and in HIV+/HCV+ patients receiving HAART remains higher than in uninfected persons.

14.
J Synchrotron Radiat ; 19(Pt 4): 596-601, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22713896

RESUMO

The design and the commissioning results of a portable and compact spectrometer for the high harmonics content characterization of the extreme-ultraviolet radiation of FLASH (free-electron laser in DESY, Hamburg, Germany) are presented. The instrument is a grazing-incidence flat-field spectrometer equipped with two variable-line-spaced gratings; it covers the 2-40 nm wavelength region with a spectral resolution in the 0.1-0.2% range. Both spectral and intensity fluctuations of the fundamental emission and the harmonics are monitored.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...