Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Surg Endosc ; 22(2): 333-42, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18071818

RESUMO

BACKGROUND: A new endoluminal fundoplication (ELF) technique performed transorally using the EsophyXtrade mark device was evaluated for the treatment of gastroesophageal reflux disease (GERD) in a prospective, feasibility clinical trial. METHODS: Nineteen patients were enrolled into the study. Inclusion criteria were chronic and symptomatic GERD, proton pump inhibitor (PPI) dependence, and the absence of esophageal motility disorder. Two patients were excluded due to esophageal stricture and a 6 cm hiatal hernia. The median duration of GERD symptoms and PPI use in the remaining 17 patients was 10 and 6 years, respectively. The ELF procedure was designed to partially reconstruct the antireflux barrier through the creation of a valve at the gastroesophageal junction. RESULTS: The ELF-created valves had a median length of 4 cm (range 3-5 cm) and circumference of 210 degrees (180-270 degrees ). Adherence of the valves to the endoscope was tight (n = 14) or moderate (n = 3). Hiatal hernias present in 13 patients (76%) were all reduced. Adverse events were limited to mild or moderate pharyngeal irritation and epigastric pain, which resolved spontaneously. After 12 months, the ELF valves (n = 16) had a median length of 3 cm (1-4 cm) and a circumference of 200 degrees (150-210 degrees ). Eighty-one percent of valves retained their tightness. The hiatal hernias present at the baseline remained reduced in 62% of patients. The median GERD-HRQL scores improved by 67% (17-6), and nine patients (53%) improved their scores by >or=50%. Eighty-two percent of patients were satisfied with the outcome of the procedure, 82% remained completely off PPIs, and 63% had normal pH. CONCLUSION: The study demonstrated technical feasibility and safety of the ELF procedure using the EsophyX device. The study also demonstrated maintenance of the anatomical integrity of the ELF valves for 12 months and provided preliminary data on ELF efficacy in reducing the symptoms and medication use associated with GERD.


Assuntos
Esofagoscopia , Fundoplicatura/instrumentação , Fundoplicatura/métodos , Refluxo Gastroesofágico/cirurgia , Adulto , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
2.
Surg Endosc ; 21(12): 2322-5, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17721806

RESUMO

Esophago-gastric necrosis is a surgical emergency associated with high morbidity and mortality. We report a laparoscopic transhiatal esophago-gastrectomy performed on a 43-year-old male, presenting two hours after hydrochloric acid ingestion. A gastroscopy showed several oral mucosal ulcers, a significant edema of the pharynx and larynx, a necrosis of the middle and lower esophagus and of the gastric fundus and antrum. A conservative strategy with intensive care observation was initially followed. After a change of clinical signs, chest-abdominal computed tomography was realized and a pneumoperitoneum with free fluid in the left subphrenic space and bilateral pleural effusions was in evidence. A laparoscopic exploration was proposed to the patient, and confirmed the presence of free peritoneal fluid and necrosis with perforation of the upper part of the stomach. A laparoscopic total gastrectomy with subtotal esophagectomy was performed; the procedure finished with an esophagostomy on the left side of the neck and a laparoscopic feeding jejunostomy (video). Total operative time was 235 minutes. After six months a digestive reconstruction with esophagocoloplasty by laparotomy and cervicotomy was easily realized thanks to the advantages (few adhesions, bloodless, and simple colic mobilization) of the previous minimally invasive surgery.


Assuntos
Queimaduras Químicas/cirurgia , Esofagectomia/métodos , Esôfago/lesões , Gastrectomia/métodos , Ácido Clorídrico/toxicidade , Laparoscopia , Estômago/lesões , Adulto , Cáusticos/toxicidade , Tratamento de Emergência , Humanos , Masculino , Tentativa de Suicídio
3.
Hernia ; 11(2): 179-83, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17131071

RESUMO

Diaphragmatic hernias can present as retrocostoxiphoid hernias (RCXH) or diaphragmatic dome hernias. The RCXH include the Larrey hernia (LH), the Morgagni hernia (MH), and the Larrey-Morgagni hernia (LMH). These congenital hernias are usually asymptomatic, and the diagnosis is simplified by two exams: chest X-ray, and thoraco-abdominal computed tomography (CT) scan. The potential risk in this condition is small-bowel incarceration in the hernia defect and subsequent obstruction. We report two cases of LH and one case of LMH treated by laparoscopy between February 2004 and October 2005, with a review of the surgical techniques. Two different laparoscopic techniques were used: the tension-free technique, and resection of the hernia sac with closure of the defect and reinforcement by prosthesis. One patient presented a postoperative cardiac tamponade due to a clip-induced bleeding of an epicardial artery at the inferior surface of the heart. Treatment by laparoscopy is feasible, but a consensus regarding the best laparoscopic repair is needed.


Assuntos
Hérnia Diafragmática/cirurgia , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Adolescente , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
Artigo em Inglês | MEDLINE | ID: mdl-17190659

RESUMO

A novel endoluminal fundoplication (ELF) technique using a trans-oral and fastener-deploying device (EsophyX, EndoGastric Solutions) was developed and evaluated for feasibility, safety and the treatment of gastroesophageal reflux disease (GERD) in a series of bench, animal, human (phase 1, phase 2, commercial registry) studies. The studies verified biological compatibility, durability and non-toxicity of the polypropylene fasteners as well as the feasibility of the ELF technique. The results of the preclinical testing indicated that the EsophyX device was shown to be safe, and capable of deploying fasteners directly into tissue and forming an interrupted suture line at the base of the gastro-esophageal valve (GEV). Moreover, the studies demonstrated that the ELF technique performed using the EsophyX device resulted in the creation of new GEVs of 3-5 cm in length and a circumference of 200 degrees -310 degrees , which maintained their anatomical aspects at six months. The ELF-created GEVs appeared similar to those created by laparoscopic anti-reflux surgery (LARS). The ELF procedure also resulted in reduction of all small hiatal hernias (2 cm in size) and restoration of the angle of His. The ELF procedure provides an anatomical approach similar to that of LARS for the treatment of GERD.


Assuntos
Endoscopia do Sistema Digestório/instrumentação , Fundoplicatura/instrumentação , Refluxo Gastroesofágico/cirurgia , Adulto , Idoso , Animais , Cães , Endoscopia do Sistema Digestório/métodos , Estudos de Viabilidade , Feminino , Fundoplicatura/métodos , Hérnia Hiatal/cirurgia , Humanos , Pessoa de Meia-Idade , Segurança , Instrumentos Cirúrgicos
5.
Surg Endosc ; 15(9): 918-23, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11605106

RESUMO

BACKGROUND: The laparoscopic surgical approach has proven its benefit for the patient. There are however several shortcomings, which have triggered considerable research for improvement. One improvement may be the introduction of telesurgery by the interposition of a computer interface between surgeon and patient. MATERIAL AND METHODS: A prospective randomized study was conducted in an advanced laparoscopic procedure, Nissen fundoplication. The control group underwent the conventional laparoscopic approach, while the investigational group underwent the telesurgical approach. RESULTS: Feasibility was 100%. The procedure was more time consuming in the Telesurgical group, at all stages of the operation. Mortality was nil and morbidity was comparable in both groups. CONCLUSION: The telesurgical approach is feasible in advanced laparoscopic procedures like Nissen fundoplication. At the present time there is however no obvious added benefit from this new technique.


Assuntos
Fundoplicatura/métodos , Refluxo Gastroesofágico/cirurgia , Laparoscopia/métodos , Robótica/métodos , Telemedicina/métodos , Adolescente , Adulto , Estudos de Viabilidade , Feminino , Fundoplicatura/instrumentação , Fundoplicatura/normas , Humanos , Laparoscopia/normas , Masculino , Pessoa de Meia-Idade , Consulta Remota/métodos , Consulta Remota/normas , Robótica/normas , Telemedicina/instrumentação , Telemedicina/normas , Fatores de Tempo , Resultado do Tratamento
6.
World J Surg ; 25(11): 1467-77, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11760751

RESUMO

Theoretically, in laparoscopic surgery, a computer interface in command of a mechanical system (robot) allows the surgeon: (1) to recover a number a number of lost degrees of freedom, thanks to intraabdominal articulations; (2) to obtain better visual control of instrument manipulation, thanks to three-dimensional vision; (3) to modulate the amplitude of surgical motions by downscaling and stabilization; (4) to work at a distance from the patient. These advances improve the quality of surgical tasks in a perfect ergonomic position. The purpose of this paper is to evaluate the feasibility of utilizing a robot in laparoscopic surgery. The first robot-assisted procedure in humans was performed in March 1997 by our team. One hundred forty-six patients underwent robot-assisted laparoscopic surgery. Between March 1997 and February 2001 a nonconsecutive series was performed of 39 antireflux procedures, 48 cholecystectomies, 28 tubal reanastomoses, 10 gastroplasties for obesity, 3 inguinal hernias, 3 intrarectal procedures, 2 hysterectomies, 2 cardiac procedures, 2 prostactectomies, 2 arteriovenous fistulas, 1 lumbar sympathectomy, 1 appendectomy, 1 laryngeal exploration, 1 varicocele ligation, 1 endometriosis cure, 1 neosalpingostomy, 1 deferent canal. The robot (Da Vinci system, Intuitive Surgical, Mountain View, CA), consists of a console and a cart with three articulated robot arms. The surgeon sits in front of the console, manipulating joysticklike handles while observing the operative field through binoculars that provide a three-dimensional picture. This computer is capable of modulating these data by eliminating physiologic tremor and by downscaling the amplitude of motions by a factor 5 or 3 to one. This study has demonstrated the feasibility of several laparoscopic robotic procedures. There is no morbidity related to the system. Operating time and the hospital stay were within acceptable limits. The system seems most beneficial in intra-abdominal microsurgery or for manipulations in a very small space. Optimized ergonomics and increased mobility of the instrument tips are beneficial in many steps of abdominal surgical procedures.


Assuntos
Laparoscopia/métodos , Robótica , Cirurgia Assistida por Computador , Estudos de Viabilidade , Feminino , Humanos , Masculino , Resultado do Tratamento
7.
Semin Laparosc Surg ; 7(1): 55-65, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10735916

RESUMO

Until now, for treatment of morbid obesity in the long term, surgery remained as the final option. For 40 years, surgeons looked at the best procedure. Among the restrictive procedures (gastroplasty), the laparoscopic adjustable silicone banding is the least invasive surgical treatment of morbid obesity. Between October 1992 and January 1998, we performed this procedure on 652 patients. Median body mass index was 45 (range, 35-65). Median hospital stay was 3 days (range, 2-10 days). The mean operative time was 80 minutes (range, 40-240 minutes). Four patients (0.6%) presented early complications: bleeding (1 patient), gastric perforation (2 patients), and pneumonia (1 patient). Forty-seven (7.2%) patients presented late complications and needed to be reoperated. There is one case of mortality. Loss of mass body weight was 62% in 2 years. According to these results, laparoscopic adjustable silicone gastric banding seems to be a safe and efficient technique.


Assuntos
Gastroplastia/métodos , Laparoscopia/métodos , Adolescente , Adulto , Idoso , Índice de Massa Corporal , Feminino , Gastroplastia/efeitos adversos , Humanos , Laparoscopia/efeitos adversos , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/cirurgia , Silicones , Redução de Peso
8.
Chirurgie ; 123(6): 580-7, 1998 Dec.
Artigo em Francês | MEDLINE | ID: mdl-9922598

RESUMO

The anatomy of the GE junction is represented by computer synthetised pictures. This method allows to represent different organs from different angles, emphasis being put on the laparoscopic angle of vision. This should improve anatomical comprehension. The synthetic pictures have been constructed in a figurative representation. Fatty tissues have been omitted whereas the peritoneal layers covering organs and defining spaces are enhanced.


Assuntos
Junção Esofagogástrica/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Laparoscopia , Interface Usuário-Computador , Anatomia/educação , Cirurgia Geral/educação , Humanos , Peritônio/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...