Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Physiol ; 12: 763408, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34777020

RESUMO

Introduction: Divers with a patent Foramen Ovale (PFO) have an increased risk for decompression sickness (DCS) when diving with compressed breathing gas. The relative risk increase, however, is difficult to establish as the PFO status of divers is usually only determined after a DCS occurrence. Methods: This prospective, single-blinded, observational study was designed to collect DCS data from volunteer divers after screening for right-to-left shunt (RLS) using a Carotid Doppler test. Divers were blinded to the result of the test, but all received a standardized briefing on current scientific knowledge of diving physiology and "low-bubble" diving techniques; they were then allowed to dive without restrictions. After a mean interval of 8 years, a questionnaire was sent collecting data on their dives and cases of DCS (if any occurred). Results: Data was collected on 148 divers totaling 66,859 dives. There was no significant difference in diving data between divers with or without RLS. Divers with RLS had a 3.02 times higher incidence of (confirmed) DCS than divers without RLS (p = 0.04). When all cases of (confirmed or possible DCS) were considered, the Relative Risk was 1.42 (p = 0.46). DCS occurred mainly in divers who did not dive according to "low-bubble" diving techniques, in both groups. Conclusion: This prospective study confirms that DCS is more frequent in divers with RLS (such as a PFO), with a Relative Risk of 1.42 (all DCS) to 3.02 (confirmed DCS). It appears this risk is linked to diving behavior, more specifically diving to the limits of the adopted decompression procedures.

2.
Front Physiol ; 12: 635132, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34381372

RESUMO

Introduction: Heart rate variability (HRV) during underwater diving has been infrequently investigated because of environment limitations and technical challenges. This study aims to analyze HRV changes while diving at variable hyperoxia when using open circuit (OC) air diving apparatus or at constant hyperoxia using a closed-circuit rebreather (CCR). We used HRV analysis in time and frequency domain adding nonlinear analysis which is more adapted to short-time analysis and less dependent on respiratory rate (Sinus respiratory arrhythmia). Materials and Methods: 18 males, 12 using OC (30 mfw for 20 min) and 6 using CCR (30 mfw for 40 min.). HRV was recorded using a polar recorder. Four samples of R-R intervals representing the dive were saved for HRV analysis. Standard deviation of normal-to-normal intervals (SDNN), square root of the mean squared differences between successive RR intervals (rMSSD), and average RR intervals (RR) in time-domain; low frequency (LF) and high frequency (HF) in frequency domain were investigated. Nonlinear analysis included fractal dimension (FrD). Results: SDNN and rMSSD were significantly increased during descent and at depth with OC, not with CCR. Mean RR interval was longer at depth with OC, but only during ascent and after the dive with CCR. HF power was higher than baseline during the descent both with OC and CCR and remained elevated at depth for OC. The LF/HF ratio was significantly lower than baseline for descent and at depth with both OC and CCR. After 30 min of recovery, the LF/HF ratio was higher than baseline with both OC and CCR. Nonlinear analysis detected differences at depth for OC and CCR. Discussion: Increased parasympathetic tone was present during diving. RR duration, SDNN; rMSSD, HF spectral power all increased during the dive above pre-dive levels. Conversely, HF power decreased (and the LF/HF increased) 30 min after the dive. Using FrD, a difference was detected between OC and CCR, which may be related to differences in partial pressure of oxygen breathed during the dive.

3.
Diving Hyperb Med ; 50(4): 405-412, 2020 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-33325023

RESUMO

INTRODUCTION: The Azoth Systems O'Dive bubble monitor is marketed at recreational and professional divers as a tool to improve personal diving decompression safety. We report the use of this tool during a 12-day dive trip aboard a liveaboard vessel. METHODS: Six divers were consistently monitored according to the user manual of the O'Dive system. Data were synchronised with the Azoth server whenever possible (depending on cell phone data signal). Information regarding ease of use, diver acceptance and influence on dive behaviour were recorded. RESULTS: In total, 157 dives were completely monitored over 11 diving days. Formal evaluations were only available after six days because of internet connection problems. Sixty-one dives resulted in the detection of bubbles, mostly in one diver, none of which produced any symptoms of decompression illness. CONCLUSIONS: The O'Dive system may contribute to increasing dive safety by making divers immediately aware of the potential consequences of certain types of diving behaviour. It was noted that bubble monitoring either reinforced divers in their safe diving habits or incited them to modify their dive planning. Whether this is a lasting effect is not known.


Assuntos
Doença da Descompressão , Mergulho , Descompressão , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...