1.
Light Sci Appl ; 11(1): 14, 2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35013092

RESUMO

Recording electric field evolution in single-shot with THz bandwidth is needed in science including spectroscopy, plasmas, biology, chemistry, Free-Electron Lasers, accelerators, and material inspection. However, the potential application range depends on the possibility to achieve sub-picosecond resolution over a long time window, which is a largely open problem for single-shot techniques. To solve this problem, we present a new conceptual approach for the so-called spectral decoding technique, where a chirped laser pulse interacts with a THz signal in a Pockels crystal, and is analyzed using a grating optical spectrum analyzer. By borrowing mathematical concepts from photonic time stretch theory and radio-frequency communication, we deduce a novel dual-output electro-optic sampling system, for which the input THz signal can be numerically retrieved-with unprecedented resolution-using the so-called phase diversity technique. We show numerically and experimentally that this approach enables the recording of THz waveforms in single-shot over much longer durations and/or higher bandwidth than previous spectral decoding techniques. We present and test the proposed DEOS (Diversity Electro-Optic Sampling) design for recording 1.5 THz bandwidth THz pulses, over 20 ps duration, in single-shot. Then we demonstrate the potential of DEOS in accelerator physics by recording, in two successive shots, the shape of 200 fs RMS relativistic electron bunches at European X-FEL, over 10 ps recording windows. The designs presented here can be used directly for accelerator diagnostics, characterization of THz sources, and single-shot Time-Domain Spectroscopy.

2.
J Synchrotron Radiat ; 26(Pt 5): 1514-1522, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31490139

RESUMO

Free-electron lasers (FELs) based on superconducting accelerator technology and storage ring facilities operate with bunch repetition rates in the MHz range, and the need arises for bunch-by-bunch electron and photon diagnostics. For photon-pulse-resolved measurements of spectral distributions, fast one-dimensional profile monitors are required. The linear array detector KALYPSO (KArlsruhe Linear arraY detector for MHz-rePetition rate SpectrOscopy) has been developed for electron bunch or photon pulse synchronous read-out with frame rates of up to 2.7 MHz. At the FLASH facility at DESY, a current version of KALYPSO with 256 pixels has been installed at a grating spectrometer as online diagnostics to monitor the pulse-resolved spectra of the high-repetition-rate FEL pulses. Application-specific front-end electronics based on MicroTCA standard have been developed for data acquisition and processing. Continuous data read-out with low latency in the microsecond range enables the integration into fast feedback applications. In this paper, pulse-resolved FEL spectra recorded at 1.0 MHz repetition rate for various operation conditions at FLASH are presented, and the first application of an adaptive feedback for accelerator control based on photon beam diagnostics is demonstrated.


Assuntos
Refratometria/instrumentação , Elétrons , Desenho de Equipamento , Lasers , Fótons , Espalhamento de Radiação , Síncrotrons
3.
Appl Opt ; 41(34): 7167-72, 2002 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-12477104

RESUMO

In the framework of current development in 157-nm lithography we have investigated the performance of photodetectors with emphasis to their stability and linearity. The measurements were performed in the radiometry laboratories of the Physikalisch-Technische Bundesanstalt at the Berlin electron-storage rings BESSY I and BESSY II with spectrally dispersed synchrotron radiation as well as with highly pulsed F2 laser radiation at 157 nm in combination with a cryogenic radiometer as the primary detector standard. Relative standard uncertainties of as little as 1% were achieved for the calibration of photodetectors in the spectral range of ultraviolet and vacuum-ultraviolet radiation.