Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artif Cells Nanomed Biotechnol ; 46(sup1): 219-229, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29265950

RESUMO

In recent decades, tissue engineering strategies have been proposed for the treatment of musculoskeletal diseases and bone fractures to overcome the limitations of the traditional surgical approaches based on allografts and autografts. In this work we report the development of a composite porous poly(dl-lactide-co-glycolide) scaffold suitable for bone regeneration. Scaffolds were produced by thermal sintering of porous microparticles. Next, in order to improve cell adhesion to the scaffold and subsequent proliferation, the scaffolds were coated with the osteoconductive biopolymers chitosan and sodium alginate, in a process that exploited electrostatic interactions between the positively charged biopolymers and the negatively charged PLGA scaffold. The resulting scaffolds were characterized in terms of porosity, degradation rate, mechanical properties, biocompatibility and suitability for bone regeneration. They were found to have an overall porosity of ∼85% and a degradation half time of ∼2 weeks, considered suitable to support de novo bone matrix deposition from mesenchymal stem cells. Histology confirmed the ability of the scaffold to sustain adipose-derived mesenchymal stem cell adhesion, infiltration, proliferation and osteo-differentiation. Histological staining of calcium and microanalysis confirmed the presence of calcium phosphate in the scaffold sections.


Assuntos
Fosfatos de Cálcio/metabolismo , Diferenciação Celular/efeitos dos fármacos , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Poliglactina 910/química , Poliglactina 910/farmacologia , Tecido Adiposo/citologia , Humanos , Fenômenos Mecânicos , Células-Tronco Mesenquimais/metabolismo , Osteogênese/efeitos dos fármacos , Poliglactina 910/metabolismo , Porosidade
2.
J Surg Res ; 201(2): 286-92, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27020809

RESUMO

BACKGROUND: Biomechanical and histological properties of stapled bronchi with and without bovine pericardial matrix plus collagen reinforcement are analyzed. MATERIALS AND METHODS: Pneumonectomy with mechanical bronchial suture was performed in the swine model. Pigs were randomly assigned to three groups: three-row staplers without reinforcement (Traditional), with reinforcement (Buttressed) and control "wild type", non-resected normal bronchus (Normal). Intraoperative test was carried for air leaks at 20/30/40 mm Hg endobronchial pressure. After 60 d, tracheobronchial specimen was harvested, stocked, and analyzed. Tensile test was performed using INSTRON 5965 loading frame machine. Maximal strain resistance value, length of elongation at rupture parameter, and stiffness coefficient (K) were evaluated. Histological analysis was performed. Sample size calculation was assessed (four per group), and the Student t-test was used to statistically evaluate differences in biomechanical variables. RESULTS: No fistula occurred. Biomechanical analysis showed that maximal strain resistance is 41.22 ± 2.11 N (Traditional), 24.53 ± 3.47 N (Buttressed), and 30.91 ± 0.29 N (Normal); elongation at rupture is 16.01 ± 1.82 mm (Traditional), 12.89 ± 0.48 mm (Buttressed), and 9.32 ± 0.11 mm (Normal). Finally, K is 2.59 ± 0.16 N/mm (Traditional), 1.91 ± 0.33 N/mm (Buttressed), and 3.32 ± 0.01 N/mm (Normal). Stumps without reinforcement proved higher resistance and length of elongation than reinforced ones. Normal bronchial tissue shows the highest stiffness coefficient. Statistical analysis produced significant values for each biomechanical feature. Group Buttressed stumps show greater thickness and a substantial inflammatory reaction with granulation tissue along the whole scar and around areas of discontinuity within the scar, not yet healed. CONCLUSIONS: Reinforcing the mechanical suture line of bronchial stump with bovine pericardial matrix plus collagen shows suboptimal biomechanical and histological characteristics compared to using the stapler alone.


Assuntos
Colágeno/efeitos adversos , Pneumonectomia/métodos , Grampeamento Cirúrgico , Cicatrização/efeitos dos fármacos , Animais , Bovinos , Distribuição Aleatória , Suínos
3.
Technol Health Care ; 24(1): 73-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26409527

RESUMO

BACKGROUND: Biomechanical behaviour evaluation of a suture is an important information for the surgeon to choose the best technique to perform. OBJECTIVE: To assess the biomechanical behavior of the native and mechanically sutured bronchi. METHODS: Ten bronchi were harvested from slaughtered pigs and then randomly separated in two groups, a control intact group and a sutured group where specimens were cut in half and sutured, to evaluate mechanical properties during a tensile test using a loading frame machine. In addition optoelectric motion tracking system was used to evaluate suture profile motion during the test. RESULTS: Significant differences (p < 0.05) were found between the two groups for the parameters investigated. The control group showed a higher maximal stress resistance and stiffness than the suture group, while elongation at rupture was increased in the sutured group. All the sutures broke in symmetric manner, as the mean of the side difference of the sutured specimens was 0.93 ± 0.80 mm at rupture. CONCLUSIONS: Biomechanical behaviour of native and sutured bronchi was evaluated, giving highly reproducible parameters regarding mechanical properties that may help clinicians and bioengineers to rationalize the choice for a particular suture material or suture technique, increasing surgical outcomes.


Assuntos
Brônquios/cirurgia , Ruptura/fisiopatologia , Ruptura/cirurgia , Suturas , Resistência à Tração , Animais , Fenômenos Biomecânicos , Humanos , Modelos Animais , Suínos
4.
Clin Oral Investig ; 20(7): 1547-50, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26531192

RESUMO

OBJECTIVE: The aim of this study on human cadavers was to compare the accuracy of two electronic apex locators (EALs) Dentaport ZX (J. Morita Corporation, Tokyo, Japan) and Raypex 6 (VDW, Munich, Germany). MATERIALS AND METHODS: Twenty-two single rooted teeth of four human cadaver heads were scheduled for this study. Before the extraction, an access cavity was opened and the crown was cut to establish a stable reference point for all measurements. The working length determination was performed with Dentaport ZX and Raypex 6 in the presence or not of 5.25 % sodium hypochlorite (SH) using a k-file 10. The teeth were then extracted and the real working length (RWL) was measured under a stereomicroscope at ×30 magnification. The difference between the two working lengths was calculated: positive values indicate measurements exceeding the foramen, while negative values indicated measurements short of the foramen. The data were analyzed with a t test analysis. RESULTS: The mean of distances was 0.33 ± 0.20 mm and 0.32 ± 0.2 mm for Dentaport ZX respectively in the presence or not of SH and 0.38 ± 0.20 mm and 0.39 ± 0.19 mm for Raypex 6. No statistical differences were found between the two devices (p > 0.05). CONCLUSIONS: Both apex locators showed a high accuracy in the presence or not of SH. CLINICAL RELEVANCE: Both electronic apex locators can be recommended for clinical use and their accuracy is not affected by SH.


Assuntos
Odontometria/instrumentação , Tratamento do Canal Radicular/instrumentação , Ápice Dentário/anatomia & histologia , Cadáver , Humanos , Irrigantes do Canal Radicular/química , Hipoclorito de Sódio/química , Propriedades de Superfície
5.
Sports Biomech ; 14(4): 384-93, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26625185

RESUMO

The purpose of the study was to evaluate whether using only the semitendinosus as a tripled short graft would affect the electromechanical delay (EMD) of the knee flexors. EMD was evaluated in volunteers (N = 15) after they had undergone surgery for anterior cruciate ligament (ACL) reconstruction where the semitendinosus tendon alone was used as a graft. The results were compared with the intact leg and healthy controls (N = 15). After warming up, each subject performed four maximally explosive isometric contractions on an isokinetic dynamometer. Torques were measured by the dynamometer, while the electrical activity of the semitendinosus and biceps femoris muscles was detected using surface electromyography. EMD was found to be significantly increased (p = 0.001) in patients who had undergone ACL reconstruction compared to the controls. On the contrary, no significant differences (p = 0.235) were found for the biceps femoris muscle between the two groups. Similar results were found when the study group was compared with the intact leg group (p = 0.027 for semitendinosus and p = 0.859 for biceps femoris). Harvesting the semitendinosus tendon increases the EMD for the semitendinosus muscle but does not influence the EMD outcomes for the biceps femoris muscle.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Ligamento Cruzado Anterior/cirurgia , Contração Isométrica/fisiologia , Articulação do Joelho/fisiopatologia , Músculo Esquelético/fisiopatologia , Tendões/transplante , Adulto , Lesões do Ligamento Cruzado Anterior , Estudos de Casos e Controles , Eletromiografia , Humanos , Articulação do Joelho/cirurgia , Masculino , Adulto Jovem
6.
J Orthop Surg Res ; 7: 28, 2012 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-22704638

RESUMO

BACKGROUND: Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. However, results of later conversion to total knee replacement may be compromised by periprosthetic bone loss. Previous clinical studies have demonstrated a decrease in distal femoral bone mineral density after patellofemoral joint replacement. It is unclear whether this is due to periprosthetic stress shielding. The main objective of the current study was to evaluate the stress shielding effect of prosthetic replacement with 2 different patellofemoral prosthetic designs and with a total knee prosthesis. METHODS: We developed a finite element model of an intact patellofemoral joint, and finite element models of patellofemoral joint replacement with a Journey PFJ prosthesis, a Richards II prosthesis, and a Genesis II total knee prosthesis. For each of these 4 finite element models, the average Von Mises stress in 2 clinically relevant regions of interest were evaluated during a simulated squatting movement until 120 degrees of flexion. RESULTS: During deep knee flexion, in the anterior region of interest, the average Von Mises stress with the Journey PFJ design was comparable to the physiological knee, while reduced by almost 25% for both the Richards II design and the Genesis II total knee joint replacement design. The average Von Mises stress in the supracondylar region of interest was similar for both patellofemoral prosthetic designs and the physiological model, with slightly lower stress for the Genesis II design. CONCLUSIONS: Patellofemoral joint replacement results in periprosthetic stress-shielding, although to a smaller degree than in total knee replacement. Specific patellofemoral prosthetic design properties may result in differences in femoral stress shielding.


Assuntos
Artroplastia do Joelho , Fêmur/fisiologia , Análise de Elementos Finitos , Articulação Patelofemoral/fisiologia , Articulação Patelofemoral/cirurgia , Estresse Mecânico , Artroplastia do Joelho/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...