Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Infect Control Hosp Epidemiol ; 40(2): 158-163, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30698135

RESUMO

OBJECTIVE: To evaluate the efficacy of multiple ultraviolet (UV) light decontamination devices in a radiology procedure room. DESIGN: Laboratory evaluation. METHODS: We compared the efficacy of 8 UV decontamination devices with a 4-minute UV exposure time in reducing recovery of methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus (VRE), and Clostridium difficile spores on steel disk carriers placed at 5 sites on a computed tomography patient table. Analysis of variance was used to compare reductions for the different devices. A spectrometer was used to obtain irradiance measurements for the devices. RESULTS: Four standard vertical tower low-pressure mercury devices achieved 2 log10CFU or greater reductions in VRE and MRSA and ~1 log10CFU reductions in C. difficile spores, whereas a pulsed-xenon device resulted in less reduction in the pathogens (P<.001). In comparison to the vertical tower low-pressure mercury devices, equal or greater reductions in the pathogens were achieved by 3 nonstandard low-pressure mercury devices that included either adjustable bulbs that could be oriented directly over the exam table, a robotic base allowing movement along the side of the table during operation, or 3 vertical towers operated simultaneously. The low-pressure mercury devices produced primarily UV-C light, whereas the pulsed-xenon device produced primarily UV-A and UV-B light. The time required to move the devices from the corner of the room and set up for operation varied from 18 to 59 seconds. CONCLUSIONS: Many currently available UV devices could provide an effective and efficient adjunct to manual cleaning and disinfection in radiology procedure rooms.


Assuntos
Desinfecção/métodos , Equipamentos Médicos Duráveis , Fômites/microbiologia , Raios Ultravioleta , Clostridioides difficile/efeitos da radiação , Contagem de Colônia Microbiana , Infecção Hospitalar/prevenção & controle , Descontaminação/métodos , Contaminação de Equipamentos/prevenção & controle , Staphylococcus aureus Resistente à Meticilina/efeitos da radiação , Esporos Bacterianos/efeitos da radiação , Fatores de Tempo , Enterococos Resistentes à Vancomicina/efeitos da radiação , Xenônio
3.
Infect Control Hosp Epidemiol ; 39(12): 1467-1469, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30526714

RESUMO

In 4 hospitals, we demonstrated frequent dispersal of fluorescent tracer and fluoroquinolone-resistant gram-negative bacilli from sink drains to sink bowls and to surfaces outside the bowl. Fluorescent tracer dispersal correlated inversely with the depth of the sink bowl. Modifications in sink design could substantially reduce the risk for pathogen dissemination.


Assuntos
Infecção Hospitalar/transmissão , Contaminação de Equipamentos , Fluoroquinolonas/farmacologia , Bactérias Gram-Negativas/isolamento & purificação , Infecções por Bactérias Gram-Negativas/transmissão , Abastecimento de Água , Infecção Hospitalar/microbiologia , Desinfecção/métodos , Farmacorresistência Bacteriana , Corantes Fluorescentes , Hospitais , Humanos , Modelos Logísticos , Análise Multivariada , Ohio , Águas Residuárias/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...