Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Eur Radiol ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769164

RESUMO

OBJECTIVES: Somatostatin receptor positron emission tomography/computed tomography (SSTR-PET/CT) using [68Ga]-labeled tracers is a widely used imaging modality for neuroendocrine tumors (NET). Recently, [18F]SiTATE, a SiFAlin tagged [Tyr3]-octreotate (TATE) PET tracer, has shown great potential due to favorable clinical characteristics. We aimed to evaluate the reproducibility of Somatostatin Receptor-Reporting and Data System 1.0 (SSTR-RADS 1.0) for structured interpretation and treatment planning of NET using [18F]SiTATE. METHODS: Four readers assessed [18F]SiTATE-PET/CT of 95 patients according to the SSTR-RADS 1.0 criteria at two different time points. Each reader evaluated up to five target lesions per scan. The overall scan score and the decision on peptide receptor radionuclide therapy (PRRT) were considered. Inter- and intra-reader agreement was determined using the intraclass correlation coefficient (ICC). RESULTS: The ICC analysis on the inter-reader agreement using SSTR-RADS 1.0 for identical target lesions (ICC ≥ 85%), overall scan score (ICC ≥ 90%), and the decision to recommend PRRT (ICC ≥ 85%) showed excellent agreement. However, significant differences were observed in recommending PRRT among experienced readers (ER) (p = 0.020) and inexperienced readers (IR) (p = 0.004). Compartment-based analysis demonstrated good to excellent inter-reader agreement for most organs (ICC ≥ 74%), except for lymph nodes (ICC ≥ 53%). CONCLUSION: SSTR-RADS 1.0 represents a highly reproducible and consistent framework system for stratifying SSTR-targeted PET/CT scans, even using the novel SSTR-ligand [18F]SiTATE. Some inter-reader variability was observed regarding the evaluation of uptake intensity prior to PRRT as well as compartment scoring of lymph nodes, indicating that those categories require special attention during further clinical validation and might be refined in a future SSTR-RADS version 1.1. CLINICAL RELEVANCE STATEMENT: SSTR-RADS 1.0 is a consistent framework for categorizing somatostatin receptor-targeted PET/CT scans when using [18F]SiTATE. The framework serves as a valuable tool for facilitating and improving the management of patients with NET. KEY POINTS: SSTR-RADS 1.0 is a valuable tool for managing patients with NET. SSTR-RADS 1.0 categorizes patients with showing strong agreement across diverse reader expertise. As an alternative to [68Ga]-labeled PET/CT in neuroendocrine tumor imaging, SSTR-RADS 1.0 reliably classifies [18F]SiTATE-PET/CT.

2.
Eur J Radiol ; 134: 109424, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33259990

RESUMO

OBJECTIVE: Follow-up of aortic aneurysms by computed tomography (CT) is crucial to balance the risks of treatment and rupture. Artificial intelligence (AI)-assisted radiology reporting promises time savings and reduced inter-reader variabilities. METHODS: The influence of AI assistance on the efficiency and accuracy of aortic aneurysm reporting according to the AHA / ESC guidelines was quantified based on 324 AI measurements and 1944 radiological measurements: 18 aortic aneurysm patients, each with two CT scans (arterial contrast phase, electrocardiogram-gated) with an interval of at least six months have been included. One board-certified radiologist and two residents (8/4/2 years of experience in vascular imaging) independently assessed aortic diameters at nine landmark positions. Aneurysm extensions were compared with original CT reports. After three weeks washout period, CTs were re-assessed, based on graphically illustrated AI measurements. RESULTS: Time-consuming guideline-compliant aortic measurements revealed additional affections of the root / arch for 80 % of aneurysms that had initially been reported to be limited to the ascending aorta. AI assistance reduced mean reporting time by 63 % from 13:01 to 04:46 min including manual corrections of AI measurements (performed for 33.6 % of all measurements with predominance at the sinuses of Vasalva). AI assistance reduced total diameter inter-reader variability by 42.5 % (0.42 / 1.16 mm with / without AI assistance, mean of all patients and landmark positions, significant reduction for 6 out of 9 measuring positions). Conventional and AI-assisted quantification aneurysm progress varied to small extent (mean of 0.75 mm over all patients / landmark positions) not significantly exceeding radiologist's inter-reader variabilities. CONCLUSIONS: Guideline-compliant aorta measurement is crucial to report detailed aneurysm extension which might affect the strategy of interventional repair. AI assistance promises improved reporting efficiency and has high potential to reduce radiologist's inter-reader variabilities that can hamper diagnostic follow-up accuracy. KEY POINT: The time-consuming guideline-compliant aorta aneurysm assessment is crucial to report aneurysm extension in detail; AI-assisted measurement reduces reporting time, improves extension evaluation and reduces inter-reader variability.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma Aórtico , Aorta Torácica , Aneurisma da Aorta Torácica/diagnóstico por imagem , Inteligência Artificial , Seguimentos , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
3.
Clin Hemorheol Microcirc ; 76(4): 453-458, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33216017

RESUMO

BACKGROUND: HCC as the 6th most common tumor entity with the fourth highest mortality and an increasing prevalence especially due to today's lifestyle acquires a high attention in the clinical setting. Beside CECT and CEMRI, CEUS depicts a dynamic, low-risk and radiation free imaging method that finds its use mainly in screening and active surveillance programs. PURPOSE: The aim of the retrospective study was to evaluate the diagnostic value of CEUS in correlation to pathologic findings. MATERIALS AND METHODS: Between 2004 and 2018 a total number of 119 patients were included in this retrospective single-center study. Every patient underwent CEUS in addition to a native B-mode and Color-Doppler scan. After given informed consent SonoVue® (Bracco, Milan, Italy), a second-generation blood-pool agent, was used as contrast medium. Every examination was performed and interpreted by a single experienced radiologist (EFSUMB level 3). A low mechanical index (MI) of <0,2 was chosen to obtain a good imaging quality. RESULTS: All 119 included patients received CEUS followed by a liver biopsy for inter-modality comparison. In correlation to the pathology results, CEUS showed a diagnostic sensitivity of 96,6%, a specificity of 63,9%, a PPV of 86,7% and a NPV of 88,5% by detecting liver lesions suspicious for HCC. According to the Cohen's Kappa coefficient (k = 0,659) CEUS shows a strong inter-modality agreement in comparison to the histopathological finding. CONCLUSION: With a high sensitivity and a strong cross-modality comparability to histopathology, the CEUS is highly effective in the detection of suspicious HCC lesions.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste/uso terapêutico , Neoplasias Hepáticas/diagnóstico por imagem , Ultrassonografia/métodos , Carcinoma Hepatocelular/patologia , Feminino , Humanos , Neoplasias Hepáticas/patologia , Masculino , Estudos Retrospectivos
4.
BMC Anesthesiol ; 19(1): 24, 2019 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-30777015

RESUMO

BACKGROUND: Adult cardiac surgery is often complicated by elevated blood losses that account for elevated transfusion requirements. Perioperative bleeding and transfusion of blood products are major risk factors for morbidity and mortality. Timely diagnostic and goal-directed therapies aim at the reduction of bleeding and need for allogeneic transfusions. METHODS: Single-centre, prospective, randomized trial assessing blood loss and transfusion requirements of 26 adult patients undergoing elective cardiac surgery at high risk for perioperative bleeding. Primary endpoint was blood loss at 24 h postoperatively. Random assignment to intra- and postoperative haemostatic management following either an algorithm based on conventional coagulation assays (conventional group: platelet count, aPTT, PT, fibrinogen) or based on point-of-care (PoC-group) monitoring, i.e. activated rotational thromboelastometry (ROTEM®) combined with multiple aggregometry (Multiplate®). Differences between groups were analysed using nonparametric tests for independent samples. RESULTS: The study was terminated after interim analysis (n = 26). Chest tube drainage volume was 360 ml (IQR 229-599 ml) in the conventional group, and 380 ml (IQR 310-590 ml) in the PoC-group (p = 0.767) after 24 h. Basic patient characteristics, results of PoC coagulation assays, and transfusion requirements of red blood cells and fresh frozen plasma did not differ between groups. Coagulation results were comparable. Platelets were transfused in the PoC group only. CONCLUSION: Blood loss via chest tube drainage and transfusion amounts were not different comparing PoC- and central lab-driven transfusion algorithms in subjects that underwent high-risk cardiac surgery. Routine PoC coagulation diagnostics do not seem to be beneficial when actual blood loss is low. High risk procedures might not suffice as a sole risk factor for increased blood loss. TRIAL REGISTRATION: NCT01402739 , Date of registration July 26, 2011.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Procedimentos Cirúrgicos Cardíacos/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Idoso , Algoritmos , Transfusão de Sangue/métodos , Feminino , Humanos , Masculino , Projetos Piloto , Estudos Prospectivos , Tromboelastografia/métodos , Fatores de Tempo
5.
Handchir Mikrochir Plast Chir ; 48(5): 281-9, 2016 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-27580441

RESUMO

BACKGROUND: Wrist fusion is still a common treatment for patients with advanced stage arthritis. Since patients are often intimidated by the functional limitations, we intended to evaluate the influence of the lack of wrist motion in different positions on the dynamic grip function and the grip strength of the hand. METHODS: We simulated wrist fusion in 20° extension and 20° flexion and evaluated the following grip types: fist closure, 2 different power grips, pinch grip and precision grip. A TUB sensor glove was used, which allowed us to dynamically record the range of motion (ROM) of the finger joints as well as grip strength. Nineteen healthy subjects participated and all types of grips were performed using a standardised protocol with and without simulated wrist fusion. RESULTS: Lack of wrist motion in 20° extension had no relevant effect on the fingers' ROM, grip speed or strength. Simulated fusion in 20° flexion also had no influence on ROM or grip speed, rejecting our hypothesis that a tenodesis effect of the extensors in flexion would decrease ROM in the finger joints and grip speed. However, we were able to show a significant decrease of grip strength in flexion compared with extension or healthy wrists. The decrease averaged between 23 and 42% of healthy values, depending on the grip type. There was no change in strength distribution among the fingers. CONCLUSION: We didn't find any impact of lack of wrist motion on finger movement during forceful hand grip at normal speed. However, a significant loss of grip strength in flexed position of the wrist joint should be considered in patients with an indication for bilateral wrist fusion.


Assuntos
Força da Mão , Procedimentos Ortopédicos , Articulação do Punho/cirurgia , Articulações dos Dedos , Humanos , Amplitude de Movimento Articular , Punho
6.
Unfallchirurg ; 117(3): 221-6, 2014 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-24622905

RESUMO

Falling on the outstretched hand is a common trauma mechanism. In contrast to fractures of the distal radius, which usually are diagnosed on plain film radiographs, identifying wrist injuries requires further diagnostic methods, e.g., MRI or CT. This article provides a review of the use of MRI in the most common traumatic wrist injuries, including scaphoid fractures, TFCC lesions, and tears of the scapholunate ligament. Early and selective use of MRI as a further diagnostic method in cases of adequate clinical suspicion helps to initiate the correct treatment and, thus, prevents long-term arthrotic injuries and reduces unnecessary absence due to illness. MRI shows a high reliability in the diagnosis of scaphoid fractures and the America College of Radiology recommends MRI as method of choice after X-ray images have been made. In the diagnosis of ligament and discoid lesions, MR arthrography (MRA) using intraarticular contrast agent has considerably higher accuracy than i.v.-enhanced and especially unenhanced MRI.


Assuntos
Fraturas Ósseas/patologia , Aumento da Imagem/métodos , Ligamentos Articulares/lesões , Ligamentos Articulares/patologia , Imageamento por Ressonância Magnética/métodos , Osso Escafoide/lesões , Osso Escafoide/patologia , Lesões dos Tecidos Moles/patologia , Humanos
7.
Unfallchirurg ; 114(10): 901-12, 2011 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-20393836

RESUMO

In a prospective study a total of 49 fractures in 47 patients were treated with open reduction and palmar plate osteosynthesis. The results were evaluated radiologically, clinically and with the disability of arm-shoulder-hand (DASH) score. The emphasis was on early postoperative results. The patients consisted of 11 men and 36 women aged 21­85 years old. Very good or good results were achieved in 79.6% of the patients, a fair result in 16.3% and a poor result in 4.1% according to the Lidström criteria. In 65.9% of cases very good or good functional results were achieved, in 22.7% fair and in 11.4% only poor results. The DASH score showed high patient satisfaction in 70.2%, moderate satisfaction in 25.5% and only little satisfaction in 4.3% of patients. Complications occurred in 14.3% of patients and the average duration of sick leave was 45.8 days. Open reduction of distal radius fractures using palmar plates with multi-axial angular stability shows good radiological and functional results even shortly after the operation.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Complicações Pós-Operatórias/etiologia , Fraturas do Rádio/cirurgia , Traumatismos do Punho/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Avaliação da Deficiência , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Complicações Pós-Operatórias/diagnóstico , Estudos Prospectivos , Fraturas do Rádio/diagnóstico , Amplitude de Movimento Articular/fisiologia , Licença Médica , Inquéritos e Questionários , Traumatismos do Punho/diagnóstico , Adulto Jovem
8.
J Chem Phys ; 120(10): 4573-80, 2004 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-15267316

RESUMO

Starting from the flux of particles in a Brownian dynamics simulation we derive boundary conditions, which allow us (i) to couple a Brownian dynamics calculation to a reservoir of particles of a given density, i.e., setting up constant density boundary conditions, and (ii) to build an interface between Brownian dynamics and a diffusional treatment of adjacent simulation volumes. With these algorithms it is sometimes possible to dramatically reduce the system size--and therefore the necessary resources--of multiparticle Brownian dynamics calculations. In this paper we give one-dimensional examples which illustrate potential applications and savings.

9.
J Chem Phys ; 121(1): 457-64, 2004 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-15260567

RESUMO

Simulations were performed for up to 150 simplified spherical horse heart cytochrome c molecules in the presence of a charged surface, which serves as an approximate model for a lipid membrane. Screened electrostatic and short-ranged attractive as well as repulsive van der Waals forces for interparticle and particle-membrane interactions are utilized in the simulations. At a distance from the membrane, where particle-membrane interactions are negligible, the simulation is coupled to a noninteraction continuum analogous to a heat bath [Geyer et al., J. Chem. Phys. 120, 4573 (2004)]. From the particles' density profiles perpendicular to the planar surface binding isotherms are derived and compared to experimental results [Heimburg et al. (1999)]. Using a negatively charged structureless membrane surface a saturation effect was found for relatively large particle concentrations. Since biological membranes often contain membrane proteins, we also studied the influence of additional charges on our model membrane mimicking bacterial reaction centers. We find that the onset of the saturation occurs for much lower concentrations and is sensitive to the detailed implementation. Therefore we suggest that local distortion of membrane planarity (undulation), or lipid demixing, or the presence of charged integral membrane proteins create preferential binding sites on the membrane. Only then do we observe saturation at physiological concentrations.

10.
Phys Rev Lett ; 89(28 Pt 1): 283204, 2002 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-12513144

RESUMO

We demonstrate that the synchronization effect observed [Pedersen et al., Phys. Rev. Lett. 87, 055001 (2001)]], when a bunch of ions oscillates between two mirrors in an electrostatic ion beam trap, can be explained as a negative mass instability. We derive simple necessary conditions for the existence of a regime in which this dispersionless behavior occurs and demonstrate that in this regime, the ion trap can be used as a high resolution mass spectrometer.

11.
Spine (Phila Pa 1976) ; 26(16): 1814-6, 2001 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-11493857

RESUMO

STUDY DESIGN: A case report of a 76-year-old woman who retched up a screw from a cervical spine locking plate 5 years after anterior cervical spine fusion. The literature relevant to this topic is reviewed. OBJECTIVES: To report the rare but potentially life-threatening complication of oral screw extrusion after anterior cervical spine plating, to review the relevant literature on the topic, and to discuss the clinical management of instrumentation failure in anterior cervical spine plating. SUMMARY OF BACKGROUND DATA: Anterior cervical spine fusion and stabilization is a well-established procedure. Complications include instrumentation failure, which can progress to extrusion through the gastrointestinal tract. Management is dependent on the severity and progression of clinical and radiologic signs and symptoms. Reoperation should be considered in certain cases. METHODS: A rare complication of anterior cervical spine plating in a 76-year-old woman 5 years after the initial operation is reported. The patient was assessed with serial physical examination and radiograph and one further follow-up 3 months after the first presentation. RESULTS: The patient was asymptomatic shortly after she retched up the screw, and at the 3-month follow-up was without evidence of progression of plate dislodgement. CONCLUSION: As reported, oral extrusion of cervical spine grafts or instrumentation is rare but potentially serious. Each case of instrumentation failure should be assessed individually to decide if conservative management is appropriate or if reoperation should be considered.


Assuntos
Parafusos Ósseos/efeitos adversos , Vértebras Cervicais/cirurgia , Perfuração Esofágica/etiologia , Falha de Prótese , Fusão Vertebral/efeitos adversos , Idoso , Vértebras Cervicais/diagnóstico por imagem , Transtornos de Deglutição/diagnóstico , Transtornos de Deglutição/etiologia , Feminino , Humanos , Radiografia , Fusão Vertebral/instrumentação
12.
Acta Physiol Pharmacol Bulg ; 10(3): 16-9, 1984.
Artigo em Inglês | MEDLINE | ID: mdl-6099029

RESUMO

The intensity of the stress-induced secretion of ACTH was investigated in rats after electric lesions of Locus coeruleus and Nucleus subcoeruleus. Plasma ACTH was estimated radioimmunologically. Stress-induced ACTH release in lesioned rats was found to be significantly higher as compared with sham operated and intact animals. Some aspects of the participation of brainstem ascending noradrenergic pathways in neuroendocrine regulation are discussed.


Assuntos
Hormônio Adrenocorticotrópico/metabolismo , Tronco Encefálico/fisiologia , Norepinefrina/fisiologia , Estresse Fisiológico/metabolismo , Animais , Locus Cerúleo/fisiologia , Masculino , Ratos
13.
Appl Opt ; 22(16): 2410-2, 1983 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-18196146

RESUMO

Results achieved in high-precision molding of glass lenses are reported. The work concentrated on a 0.4- N.A. 8-mm diam lens with spherical surfaces. The glass is a specialty glass composition of index (d-line) 1.604 and Abbe number 50. Typical design tolerances which have been achieved in the molded glass lenses include relative surface figure replication of 0.06 Aim, thickness and diameter tolerances of A+/-10 Am, wedge of <10-3 rad, birefringence of less than one one-hundredth wave, and index homogeneity in the sixth decimal place. These results are directly applicable to molding precision glass aspheric lenses of similar tolerances.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...