Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Ophthalmol ; 2016: 5603763, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27688908

RESUMO

Purpose. To evaluate the difference in biomechanical properties between contact lens induced corneal warpage and normal and keratoconic eyes. Method. Prospective observational case control study, where 94 eyes of 47 warpage suspicious and 46 eyes of 23 keratoconic patients were included. Warpage suspected cases were followed until a definite diagnosis was made (warpage, normal, or keratoconus). Results. 44 eyes of 22 patients had contact lens related corneal warpage. 46 eyes of 23 people were diagnosed as nonwarpage normal eyes. 46 eyes of 23 known keratoconus patients were included for comparison. The mean age of the participants was 23.8 ± 3.8 years, and 66.2% of the subjects were female. The demographic and refractive data were not different between warpage and normal groups but were different in the keratoconus group. The biomechanical properties (corneal hysteresis or CH and corneal resistance factor or CRF) were different with the highest value in the warpage group followed by normal and keratoconus groups. CRF was 10.08 ± 1.75, 9.23 ± 1.22, and 7.38 ± 2.14 and CH was 10.21 ± 1.57, 9.59 ± 1.21, and 8.69 ± 2.34 in the warpage, normal, and keratoconus groups, respectively. Conclusion. Corneal biomechanics may be different in people who develop contact lens induced warpage.

2.
Middle East Afr J Ophthalmol ; 20(3): 234-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24014988

RESUMO

AIM: To evaluate the effect of implantation depth of Intacs microthin prescription inserts (Addition Technology Inc, Fremont, California) on visual and topographic outcomes in patients with post- laser-assisted in situ keratomileusis (LASIK) ectasias. SETTINGS AND DESIGN: Retrospective, observational case series. MATERIALS AND METHODS: In this case series, 16 eyes of 12 patients were evaluated. All cases were post-LASIK ectasia that had undergone intrastromal corneal ring segment (ICRS) implantation. The planned insertion depth was 70% of stromal thickness using a manual dissector. At least 12 months postoperatively, all eyes underwent Visante (Carl Zeiss Meditec) AS-OCT to determine insertion depth. Cases were categorized into 3 groups based on the measured implantation depth: 40-59% thickness; 60-79% thickness; and ≥80% thickness. Visual, refractive and topographic outcomes were evaluated relative to implantation depth. RESULTS: The lowest improvement in the study parameters ocurred when the implantation depth was ≥80%. In this group, uncorrected visual acuity (UCVA) and best spectacle corrected VA (BSCVA) improved less than 0.5 lines. Manifest refractive spherical equivalent (MRSE) and mean keratometry (Km) change was less than 0.5 diopters (D). The greatest improvements were observed with implantation depth of 60-79% where UCVA and BSCVA increased by 4.5 and 2.5 lines respectively, and MRSE and Km changed by approximately 2.00 D. Less improvement was found when ICRS were implanted between 40-59% of stromal thickness. CONCLUSION: Implantation of ICRS greater than 80% of stromal thickness may have no effect on visual and topographic status.


Assuntos
Doenças da Córnea/cirurgia , Substância Própria/cirurgia , Próteses e Implantes , Implantação de Prótese , Adulto , Doenças da Córnea/diagnóstico , Doenças da Córnea/etiologia , Substância Própria/patologia , Topografia da Córnea , Dilatação Patológica/diagnóstico , Dilatação Patológica/etiologia , Dilatação Patológica/cirurgia , Feminino , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Refração Ocular/fisiologia , Estudos Retrospectivos , Tomografia de Coerência Óptica , Resultado do Tratamento , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...