Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomech Eng ; 142(12)2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32601705

RESUMO

Cementless straight stems show very good survival rates. However, the more distal force application of straight stems may lead to release-related proximal stress-shielding. Nevertheless, this technical brief had the objective of conducting a biomechanical in vitro analysis comparing short stems with established straight stems with respect to their primary torsional stability. Two cementless short hip stems and three cementless straight hip stems were implanted in n = 5 synthetic femora each. Torsional torques were applied into the hip stems at a continuous interval of ±7 Nm. Micromotions were measured by six inductive extensometers on four different measurement levels. At the proximal measuring point, significantly smaller relative micromotions of the CLS® prosthesis could be detected compared to all other stem models (p < 0.05). In all stem models, smallest relative micromotions were found at the metaphyseal/diaphyseal measuring point. Only at the measuring point of the distal tips of the straight stems, statistically significantly lower relative micromotion of the CLS® stem compared to the Trendhip® stem could be found (p < 0.01). All the investigated stems generally display a rather comparable anchoring pattern and an almost physiological force application. Since the comparatively long straight stems present an anchoring pattern nearly identical to that of the examined short stems, a shortening of the established straight stems could be taken into consideration. This would offer the advantage of minimally invasive surgery and bone-saving resection as well as preservation of cancellous bone in case a revision would become necessary.


Assuntos
Prótese de Quadril , Artroplastia de Quadril , Fenômenos Biomecânicos , Fêmur , Desenho de Prótese , Estresse Mecânico
2.
J Med Case Rep ; 6: 248, 2012 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-22905749

RESUMO

INTRODUCTION: Synthol is a site enhancement oil used by bodybuilders to boost the cosmetic appearance of muscles. Here, we describe the case of a patient with severe side effects following repeated intramuscular injections of synthol in his right biceps muscle. CASE PRESENTATION: A 29-year-old Middle Eastern male bodybuilder, following intramuscular injections of synthol five years ago, presented with painful pressure in his right upper arm. On presentation to our clinic, his muscle appeared disfigured. Magnetic resonance imaging revealed scattered cystic fatty lesions in the muscle. The affected part was surgically removed and histopathology showed inflammatory changes with fibrosis and a so-called Swiss cheese pattern. CONCLUSION: Synthol injections that are used for the short-term enhancement of muscle appearance by bodybuilders bear the danger of long-term painful muscle fibrosis and disfigurement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...