Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Res Int ; 2022: 4695193, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35229002

RESUMO

OBJECTIVE: To analyze the width and height ratios of maxillary anterior teeth at different crown levels through photographs, 3D, and plaster dental model techniques in a subset of the Pakistani population. Material and Methods. This clinical study consisted of 230 participants. The maxillary impression, standardized photographs, and models were constructed for crown width and height analysis. The SPSS version 25 was used for statistical analysis. Descriptive statistics were carried out for mean, standard deviation, and percentage calculation of teeth width and height, gender, and age of participants. Paired t-test analysis was carried out to compare the dependent variables (teeth size, width, and height ratios) with independent variables (techniques applied, side disparity). A p value of ≤ 0.05 was considered statistically significant. RESULTS: The mean width and height of maxillary anterior teeth obtained through photographs, 3D, and plater models were statistically different. The 3D dental model analysis showed reliable and accurate results. The mean width and height ratio of teeth were different on both sides of the arch. There was a significant difference (p = 0.001) in crown width-height ratios at different crown levels. CONCLUSION: The width and height ratios in the studied population were different at various crown levels. The dimensions of teeth varied from the incisal to the cervical part of the crown. Hence, rather than relying on a single, fixed ratio of 78% to 80% suggested by researchers for anterior teeth, the clinician should adopt different crown width-height ratios to restore teeth with the optimum esthetic outcome.


Assuntos
Dente Canino/anatomia & histologia , Estética Dentária , Face/anatomia & histologia , Incisivo/anatomia & histologia , Coroa do Dente/anatomia & histologia , Adulto , Estatura , Estética , Feminino , Humanos , Masculino , Odontometria , Fotografia Dentária , Fatores Sexuais
2.
J Prosthet Dent ; 127(6): 845.e1-845.e9, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34340826

RESUMO

STATEMENT OF PROBLEM: The color and form of teeth are 2 of the 3 main determinants of success in an esthetic restoration; the third is dental proportion. A recent systematic review of the literature devoted to the evaluation of dental proportion is lacking. PURPOSE: The purpose of this systematic review was to investigate the quality and outcome of studies into maxillary anterior tooth proportion and to determine whether dental proportion ratios based on different geographic regions are appropriate. MATERIAL AND METHODS: An electronic search was conducted using PubMed, MEDLINE, Google Scholar, Embase, Scopus, Cochrane Library, Web of Science, and Science Direct databases. English-language articles reporting with the specific combination of medical subject heading (MeSH) key words were analyzed by 2 investigators. The titles, full text, and abstracts were scanned by investigators independently to identify articles that fulfilled the inclusion criteria. The general characteristics, outcomes, and quality of each study were reviewed and analyzed systematically. RESULTS: The search plan resulted in a total of 73 articles until September 2020; of which, 16 articles fulfilling the inclusion criteria were selected. The geographic distribution of the selected article revealed 12 articles from Asia, 2 from Continental Europe, and 2 from the United Kingdom. Golden percentage values of 25%, 15%, and 10% for central, lateral incisor, and canine teeth were not found. The mean predicted dental percentage was either larger or smaller than the successive widths of maxillary natural anterior teeth. CONCLUSIONS: The golden percentage could not be used to formulate a smile design. Rather, the dental ratios should be set on a racial and ethnic basis for a population.


Assuntos
Estética Dentária , Maxila , Dente Canino , Incisivo , Odontometria/métodos
3.
Biomed Res Int ; 2021: 6674400, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33969123

RESUMO

The objective of this paper was to evaluate the existence of golden percentage in natural maxillary anterior teeth with the aid of 3D digital dental models and 2D photographs. And to propose regional values of golden percentage for restoration of maxillary anterior teeth. For this purpose, one hundred and ninety dentate subjects with sound maxillary anterior teeth were selected. Standardized frontal images were captured with DSLR, and the apparent width of maxillary anterior teeth was measured utilizing a software on a personal laptop computer. Once the dimensions were recorded, the calculations were made according to the golden percentage theory (GPT). The data were analyzed by independent and paired T-test. The level of significance was set at p < 0.05. The golden percentage values were not found in this study. The values obtained were 16%, 15%, 20%, 20%, 15%, and 16% moving from the right canine to the left canine teeth. There was no significant gender difference in the golden percentage values. Thus, golden percentage should not be used solely for the correction of anterior teeth or for determining dental attractiveness. Emphasis should be given to a range of dental proportion on regional basis.


Assuntos
Imageamento Tridimensional , Maxila/diagnóstico por imagem , Modelos Dentários , Fotografação , Dente/diagnóstico por imagem , Feminino , Humanos , Masculino , Adulto Jovem
5.
Dent Res J (Isfahan) ; 15(3): 215-219, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29922341

RESUMO

BACKGROUND: Composite resin (CR) currently is one of the most commonly used material in restoring noncarious cervical lesions (NCCL) due to its strength and esthetics color but has microleakage problem. The aim of this study is to compare in vitro the microleakage depth between CR and porcelain in restoring NCCL. MATERIALS AND METHODS: This an in vitro study was done by preparing cavities on the buccocervical surface of 62 extracted premolar teeth which randomly assigned to two groups (n = 31) where Group 1 was restored with nanocomposite and Group 2 was cemented with porcelain cervical inlays. They were then subjected to thermocycling before immersion in 2% methylene blue dye for 24 h. Dye penetration depths were measured using Leica imaging system For statistical analysis, independent t-test was used to analyze the results (P < 0.05). RESULTS: Porcelain cervical inlay restorations demonstrated statistically lesser microleakage depth for the cervical margins (P = 0.018) when compared to CR. Deeper microleakage depth at the cervical compared to coronal margins of CR (P = 0.006) but no significant difference of both margins for porcelain cervical inlays (P = 0.600). CONCLUSION: Porcelain cervical inlays show lesser microleakage than CR which could be alternative treatment option in restoring NCCL with better marginal seal and esthetics.

6.
J Conserv Dent ; 17(6): 531-5, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25506139

RESUMO

OBJECTIVES: To investigate the effect of acidic solution on surface roughness and microleakage of tooth-colored restorative materials. MATERIALS AND METHODS: A 160 box-shaped cavities were prepared on the buccal surfaces of 160 human molars, and assigned to four groups: Group A restored with Ketac™ Molar Easymix, Group B with Fuji II™ LC, Group C with Ketac™ N100, and Group D with Filtek™ Z250, and subdivided into study and control groups (n = 20). Study groups were immersed in lemon juice (pH = 2.79) for 24 h, whilst controlgroups in deionized distilled water. All samples were immersed in 2% methylene blue dye, sectioned into two equal halves for surface roughness, and microleakage tests. Data were analyzed using Mann-Whitney and Kruskal-Wallis tests at P < 0.05. RESULTS: There was a significant difference in surface roughness of Ketac™ Molar, Fuji II™ LC, and Ketac™ N100. No significant difference was found in microleakage of Ketac™ Molar and Fuji II™ LC; however, there were significant differences in the gingival margin of Ketac™ N100, and the occlusal margin of Filtek™ Z250. CONCLUSIONS: All glass ionomer cements were eroded after exposure to the acidic drink. Filtek™ Z250 and Ketac™ Molar Easymix showed more microleakage. All materials showed more microleakage at the gingival margins.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...